12035520Q0001_Amend 0001.pdf

PDF 103 KB Posted

Attached to
Riley Pass Range Pipeline Extension and Fence Realignment Federal contract opportunity
Solicitation number
12035520Q0001
Issued by
Department of Agriculture Forest Service R1-Northern Region

View the file

Other files for this federal contract opportunity

Other files attached to Riley Pass Range Pipeline Extension and Fence Realignment, newest first.
File Type Posted
Solicitation 12035520Q0001.pdf PDF
J-1 General Wage Decision SD20200001_01.03.2020.pdf PDF
J-2 Contract Specifications.docx DOCX document
J-4 Experience Questionnaire.docx DOCX document
J-3 Drawings and Figures.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(x)

12035520Q0001 x x copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE

RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR

OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

x

BILLINGS MT 59101

5001 SOUTHGATE DR STE 2

BILLINGS OFFICE

USDA FOREST SERVICE

06/18/20200001

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

FACILITY CODE CODE

10B. DATED (SEE ITEM 13)

10A. MODIFICATION OF CONTRACT/ORDER NO.

9B. DATED (SEE ITEM 11)

9A. AMENDMENT OF SOLICITATION NO.

CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)

7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY

PAGE OF PAGES

4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)

1. CONTRACT ID CODE

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

06/18/2020

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.

ORDER NO. IN ITEM 10A.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

FY20 Riley Pass Range Pipeline Extension and Fence Realignment

Custer Gallatin National Forest

Sioux Ranger District

SEE CONTINUATION PAGE

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED

(Signature of person authorized to sign) (Signature of Contracting Officer)

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

Previous edition unusable

Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .

Solicitation 12035520Q0001, Amendment 0001 Continuation Page

1. What does Item #20301 Refer to?

Answer: 20301 Removal and Disposal is for existing old materials at fence tie in and at waterline tie in. Includes approximately 200’ of existing fence and posts.

2. Are there specifications for setting the tank?

Answer: SECTION 307 – FIBERGLASS STOCK WATER TANK INSTALLATION and manufacturer’s instructions for tank installation.

3. How many posts are required? Where are posts supposed to go?

Answer: Section 307 Part 3.2 C. All stock tanks shall have a livestock barrier and rodent escape board. Livestock barrier diagram shall be submitted to the CO for approval prior to construction. (Typical is 4 posts but other barrier configurations may be approved.)

4. On the pipeline, do you want to use male insert couplings or fused transitions?

Answer: Section 302 Part 3.4 All ends of the HDPE pipe shall be fused by a trained and experienced individual.

5. On the Tee, do you want a ball valve or stop and drain?

Answer: Section 302 Part 3.3 Stop and waste valves shall be placed at low spots, as shown on the plans, along the pipeline for winterization of the line. One Vacuum Air Release valve will be placed as shown on the plans. Valves shall be securely staked and wired in place to the valve box