Structure Name: Homestead Creek Bridge Route & MP: 216-7.922

CONDITION CODES AND REMARKS

CONDITION RATING REMARKS

WEARING SURFACE 3 Timber, section loss, decay, deterioration.

58. DECK: 6

*1. DECK SLAB/PANELS/JOISTS F Surface decay ¼”-1/2”, light end checking

C1. DECK JOINTS NA

C2. CURBS C Section loss, broken, heavy decay and rot.

C3. SIDEWALKS N/A

C4. BRIDGE RAILINGS NA

C5. DRAINS AND DRAINAGE P Broken curb D/S blocks drainage off bridge C6. RIDEABILITY F Broken, decayed wear surface on deck C7. CLEANLINESS P Broken wear surface and fines on deck

C8. UTILITIES NA

59. SUPERSTRUCTURE: 6

*1. GIRDERS 12 EA. G Minor horizontal checking, weathered.

A. DIAPHRAGMS NA

B. BRACING NA

*2. FLOOR BEAMS NA

*3. STRINGERS NA

*4. TRUSSES NA

A. CHORDS NA

B. PORTALS NA

C. VERTICALS/DIAGONAL NA

D. BRACING NA

C1. BEARING DEVICES NA

C2. PAINT NA

C3. DEFLECTION UNDER LOAD NOB

C4. VIBRATION UNDERLOAD NOB

60. SUBSTRUCTURE: 2

A *1. ALIGNMENT (TIPPING, TILTING,...) F Bulging abutments and wing walls.

B *2. EROSION OR SCOUR P Abut. # 1, sill is visable, D/S WW undermined, abut. # 1 (notes) U *3. SETTLEMENT F Abut # 1, cap is crushing, U/S section 4’, D/S section for 8’

T TIMBER ABUTMENTS (INCL. WW)

M *4. CAPS P Abut. # 1 cap moderate cap rotation /rot, crushing D/S for 11’

E *5. POSTS/PILES N/A

N *6. BACKING PLANKS F Top planks crushing with visable decay.

T *7. CRIB WALLS P Decay & rot visable, Abut. # 1, bottom beams off sill, (notes) S *8. WING WALLS P All wing wall bulging with Abut. #1, U/S sliding off sill, (notes)

OTHER ABUTMENTS

*9. CAPS N/A

*10. FOOTINGS N/A

*11. WALLS N/A

*12. PILES N/A

*13. WINGWALLS N/A

P *14. ALIGNMENT (TIPING, TILTING,…) N/A

I *15. EROSION OR SCOUR N/A

E *16. SETTLEMENT N/A

R *17. CAPS N/A

S *18. COLUMNS OR WALLS N/A

*19. FOOTINGS N/A

*20. PILES N/A

*21. BRACING N/A

* Only these items are used in the determination of the overall condition rating for that category ie. Deck, superstructure, substructure.

Other items should be rated and remarked on but NOT included in determining the overall category rating. Items enumerated using a C (ex C1) should be commented on but not rated. See the FHWA Coding Guide for further information as to what is included in condition rating.

CONDITION CODES AND REMARKS (Continued)

CONDITION RATING REMARKS

61. CHANNEL AND CHANNEL PROTECTION 7

*1. CHANNEL SCOUR/EROSION F Bedrock directs flow to abut. # 1.

*2. CHANNEL PROTECTION F Channel on bedrock.

*3. VEGETATION G Well vegetated.

*4. WATERWAY OBSTR./DRAFT G No problems noted *5. ADEQUACY OF OPENINGS F Adequacy of opening limited.

C1. CLEAR HEIGHT G 8’-3” no problems noted.

APPROACH CONDITION: P

*1. SURFACING P Rocky material at both abutments.

*2. SHOULDER EMBANKMENT F Steep, heavy vegetation *3. ROADWAY EMBANKMENT G No problems noted.

*4. APPROACH SETTLEMENT P 2-3” lip up at approaches

APPRAISAL CODES and REMARKS

36. TRAFFIC SAFETY FEATURES: 1NNN

*A. BRIDGE RAILING C Section loss, broken, heavy decay.

*B. RAIL TRANSITIONS N/A

*C. APPROACH GUARDRAILS N/A

*D. APPROACH RAIL ENDS N/A

1. SIGNING N/A

2. OBJECT MARKERS C (3) down, (1) missing, not reflective,

72. APPROACH ROADWAY ALIGNMENT: 3

1. HORIZONTAL F Curve at abut. # 1 approach.

2. VERTICAL F Grades at both approaches Bridge Appraisal Rating items may change as a result of this inspection. Use FHWA Coding Guide and Regional Office direction for appraisal rating code determination.

67. STRUCTURAL EVALUATION: 2 68. DECK GEOMETRY: 6

71. WATERWAY ADEQUACY: 9 113. SCOUR CRITICAL BRIDGES: 2

STRUCTURE LIFE REMAINING 1 SCOUR VULNERABILITY: H

CONDITION RATING OF EACH MEMBER OR ELEMENT

NA -NOT APPLICABLE

NOB -APPLICABLE, BUT NO OBSERVED. (Give reason unless obvious)

G = GOOD -ELEMENT IN NEW OR GOOD CONDITION WITH NO REPAIRS NECESSARY.

F = FAIR -ELEMENT IS STILL PERFORMING THE FUNCTION FOR WHICH IT WAS

INTENDED BUT MAY NEED MAINTENANCE.

P = POOR -ELEMENT STILL PERFORMING THE FUNCTION FOR WHICH IT WAS INTENDED

BUT IS IN NEED OF REPAIRS.

C = CRITICAL -ELEMENT IS NOT PERFORMING THE FUNCTION FOR WHICH IT WAS INTENDED

ITEM

REFERENCE

ADDITIONAL REMARKS

60.2 Undermined ‘ deep, 7” in width and 10’ in length from U/S wing wall.

60.7 Numerous members show visable rot.

60.8 Abut. # 1 D/S WW undermined 8”, full length of length of wall.

BRIDGE PHOTOS

1. APPROACH LOOKING AHEAD

2. PROFILE LOOKING DOWNSTREAM

3. STRINGER AND CRUSHING WALL # 1

4. ROTTEN,DECAYED WEAR SURFACE

CRUSHED WALL # 1 D/S

UNDERMINED WALL WITH ROT

Scour Critical Coding, Item 113 Field Evaluation Guide

Vertical Wall Abutments Not on Piles or Bedrock Parameters Codings

Scour Scenarios Is Footing Exposed?

Is Channel Constriction greater than

10%?

Is Stream Laterally or Vertically Unstable?

Is Flow Attacking?

Bank Erosion

Other factors

Scour Vulnerability

Scour Critical Code

Ideal field conditions. No active scour or stream stability issues no no no no none none Low 5

Footing Exposed Only yes no no no none none Moderate 4

Footing Undermined (evaluate severity, substrate) yes (undermined no no no none Fill in High 2

Footing Exposed Plus Constriction, Unstable or Attacking (evaluate severity, substrate) yes Fill in Moderate or High 4 or 2

Bridge Constricts Channel > 10% no yes no no none none Moderate 4

Bridge Constricts Channel > 10% plus Unstable or Attacking (evaluate severity, substrate) no yes Fill In Moderate or High 4 or 2

Bridge on Unstable Channel with riprap in good condition, size and quantity. no no yes no no none Moderate/Low 5

Bridge on Unstable Channel with bank erosion and/or damaged riprap protection no no yes no yes Fill in Moderate or High 4 or 2

Designed countermeasures installed, stable and performing well. no Fill in no Fill in Low or Moderate 7

Severe scour, abutment failing yes

(undermined) Fill in High 1 or 0

None of the above, Needs further review Fill In Not Determined 6