12_64_13_-_Booths_20251020.pdf
PDF 170 KB Posted
- Attached to
- FPCM-CMC-Booths-KR-A
- Solicitation number
- 0000037100
- Issued by
- San Luis Obispo County, San Francisco City, California
About this file
This document is a technical specification section (Section 12 64 13) for prefabricated interior free-standing single-occupant booths for the California Department of Corrections and Rehabilitation (CDCR). The specification provides detailed requirements for booth design, construction, and installation, including specific requirements for manufacturers like PoPS, Cubicall, and SpaceWorx. The booths are intended to be single-occupant, interior spaces with specific technical parameters including steel wall and ceiling panels, accessibility standards, lighting, telecommunications capabilities, and a videoconference device mounting system.
The specification outlines comprehensive technical requirements for the booths, including detailed standards for materials, construction, and performance. Key components include a minimum 10-year manufacturer's warranty, specific acoustic and fire-rating requirements, stainless steel hardware, LED lighting, network switch enclosure, Ethernet connectivity, and a mounting system for a Cisco DX80 videoconference device. The document specifies precise dimensional requirements, material gauges, finish types, and installation procedures, with an emphasis on durability, security, and accessibility in a correctional environment. Manufacturers must comply with multiple industry standards including ASTM, ANSI, and ADA requirements, and provide detailed shop drawings and product data for review.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 12_-_FPCM-CMC-Booths-KR-A_RFQ.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOOTHS
CDCR- SDD 20251020 12 64 13 – 1
SECTION 12 64 13
BOOTHS
PART 1 GENERAL
1.1 SUMMARY
A. Section Includes:
1. Prefabricated interior free-standing single-occupant booth.
1.2 REFERENCES
A. ASTM E84 – Test Method for Surface Burning Characteristics of Building Materials.
B. ASTM E90 – Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.
C. ASTM D3935 – Standard Specification for Polycarbonate (PC) Unfilled and Reinforced Material.
D. ASTM C1349 – Standard Specification for Architectural Flat Glass Clad Polycarbonate.
1.3 SUBMITTALS
A. Submit in accordance with Section 01 33 00 – Submittal Procedures and Section 01 33 23 – Shop Drawings, Product Data, and Samples.
B. Product Data:
1. Product data for products and materials indicated. Product data to include any available brochures and a technical product information sheet listing key features such as model number, base features, and optional accessories.
2. Manufacturer’s technical bulletins and installation/application instructions.
C. Shop Drawings: Include isometric and 3D images, plans, elevations, sections, details, accessories, electrical service connection, and fastening and anchorage details.
1. Seismic Anchor Plans: Submit seismic anchor plans and templates. Include location, diameter, and projection of anchor connections required to attach booths to substrate.
2. Lighting: Drawings, Diagrams, and Supporting Documents for Luminaires:
a. Include plans, elevations, sections, and mounting and attachment details.
b. Include details of luminaire assemblies. Indicate dimensions, weights, loads, required clearances, method of field assembly, components, and location and size of each field connection.
c. Include diagrams for lighting, power, signal, and control wiring.
3. Communications: Drawings, Diagrams, and Supporting Documents for Communications:
a. Include plans, elevations, sections, and mounting and attachment details.
b. Include points of connection to web-based audio/visual communication equipment and devices.
CDCR- SDD 20251020 12 64 13 – 2
4. Isometric Drawings: To aid the Owner in visualizing the proposed completed booth, provide isometric and/or computer-generated 3D image(s) of proposed product.
D. Samples:
1. Submit samples of prefinished metal and panel finishes in each selected color/finish.
1.4 COORDINATION
A. Coordinate Preinstallation Coordination Meeting with CDCR Representative.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Deliver, store, and handle packaged materials in the manufacturer’s original, sealed containers, each clearly identified with the manufacturer’s name, and name and type of product.
B. Store materials subject to damage by dirt and moisture in a clean, dry location, off the ground, and suitably protected.
1.6 WARRANTY
A. Minimum 10-year manufacturer’s warranty.
PART 2 PRODUCTS
2.1 BASIS OF DESIGN PRODUCT
A. Acceptable Manufacturers/Products – Basis of Design and subject to compliance with requirements as indicated in this specification as follows:
PoPS – Pillar of Public Safety 333 N. Green, 8th floor Chicago, Il 60607 Sales@popsbooth.com
Cubicall 580 W. Cheyenne, Suite 100 North Las Vegas, NV 89030 anthony@cubicallbooth.com
SpaceWorx 14250 Cherry Lane Ct.
Laurel, MD 20707 info@spaceworx.us
1. For manufacturers not listed, comply with substitution requirements in Section 01 25 00
– Substitution Procedures.
2.2 ACCESSIBILTY STANDARDS
A. Where called for, provide and install booth that complies with criteria specified herein and modified as required to comply with current ADA Standards for Accessible Design and current California Building Code access requirements. Accessible booths must include the following:
mailto:Sales@popsbooth.com mailto:anthony@cubicallbooth.com mailto:info@spaceworx.us
CDCR- SDD 20251020 12 64 13 – 3
1. Accessible door landing on exterior side of booth flush with interior floor level.
2. Accessible ramp leading to/from accessible ramp.
3. Sidelight(s) which allow viewing to all parts of the booth interior.
4. Stool is not required in accessible booths.
2.3 FASTENERS, SCREWS, AND BOLTS
1. All Exposed Fasteners: Stainless steel, tamperproof in accordance with Section 05 05 53
– Security Metal Fastenings.
2.4 CASTERS, LEVELING FEET, AND SEISMIC RESTRAINT
A. Provide casters, leveling feet, and seismic restraint conforming to the following:
1. Leveling casters: 800 pounds minimum load capacity; Atlas Casters Model 1000 Series #LC1030CS-SB-PHN or approved equal.
2. Leveling feet: 1,000 pounds minimum load capacity; stainless steel foot; Atlas Casters #LV6311-SS-SS or approved equal.
3. Seismic restraint: Stainless steel compatible with leveling feet; Atlas Casters #XA- LVRT63 or approved equal.
4. Securely attach booth to floor to resist overturning by seismic activity and vandalism using fasteners recommended by booth manufacturer and as specified herein.
2.5 WALLS
A. General: Prefabricated steel wall panels comprised of non-ferrous, cold-rolled steel, minimum 14-gauge interior skin, minimum 18-gauge exterior skin, with minimum 5/8-inch plywood between interior and exterior skins and acoustic lining.
1. Interior Wall Finish: Perforated metal with perforated hole spacing of 3/16-inch diameter holes at 9/32 inch on center. Omit gaps (anti-ligature) or anywhere contraband can be slipped into/hidden.
a. Color: Prefinished; white or off-white as selected by the CDCR Representative from the manufacturer’s standard range.
2. Exterior Wall Finish: Smooth metal. Omit gaps (anti-ligature) or anywhere contraband can be slipped into/hidden.
a. Color: Prefinished [Match CDCR Representative’s sample.][Selected by the CDCR
Representative from the manufacturer’s standard range.]
3. Flame spread rating of materials must not exceed 25, smoke density must not exceed 450 per ASTM E84.
4. Acoustic Performance: Wall assembly must achieve minimum STC rating of 35dB per ASTM E90, not including any applied acoustic treatment.
2.6 CEILING/ROOF
A. General: Prefabricated steel ceiling/roof panel comprised of non-ferrous, cold-rolled steel, minimum 14-gauge interior skin, minimum 18-gauge exterior skin, with minimum 5/8-inch plywood between interior and exterior skins.
CDCR- SDD 20251020 12 64 13 – 4
1. Color: Prefinished; match walls.
2. Flame spread rating of materials must not exceed 25, smoke density must not exceed 450 per ASTM E84.
3. Acoustic Performance: Ceiling assembly must achieve minimum STC rating of 35dB per ASTM E90, not including any applied acoustic treatment.
2.7 ACOUSTIC INTERIOR WALL/CEILING PANELS
A. General: Removable, tackable, washable, semi-rigid acoustical impact-resistant wall covering.
B. Acceptable Manufacturers/Products – Basis of Design:
1. FabricMate; ReCore Acousti .60.
a. Thickness: One-inch.
b. Density: Minimum 3 PCF.
c. Flame spread rating of materials must not exceed 25, smoke density must not exceed
450 per ASTM E84.
d. Formaldehyde-Free, low VOC’s.
e. Cover all unglazed wall surfaces to no greater than 2 inches from door, wall corners, ceiling, and floor, excluding below desk.
f. Maintain 3 inches clearance of insulation around recessed light fixtures not rated for or protected from contact with insulation.
2. For manufacturers/products not listed, comply with substitution requirements in Section 01 25 00 – Substitution Procedures.
2.8 FLOORS
A. General: Design to support minimum 40 pounds per square foot live load.
B. Finish: Rubber tile or sheet fully adhered to substrate.
2.9 STEEL DOORS AND SIDELITES
A. References:
1. American National Standards Institute (ANSI) / Steel Door Institute (D-SDI):
a. ANSI/SDI A250.8 – Specifications for Standard Steel Doors &Frames (SDI-100)
b. ANSI/SDI 250.10 – Test Procedure and Acceptance Criteria for Prime Painted Steel
Surfaces for Steel Doors and Frames.
2. ASTM International (formerly American Society for Testing and Materials) (ASTM):
a. ASTM A653 – Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or
Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
3. American Welding Society (AWS):
a. AWS D1.1 – Standard Welding Code – Steel.
b. AWS D1.3 – Standard Welding Code – Sheet Steel
4. Certification Listings; Intertek Testing Services NA, Inc.
5. Hollow Metal Manufacturers Association (HMMA).
6. Steel Door Institute (SDI):
a. ANSI/SDI-A250.8 – Specifications for Standard Steel Doors and Frames (SDI-100).
CDCR- SDD 20251020 12 64 13 – 5
7. The Society for Protective Coatings (SSPC) (also known as The Association for Materials Protection
B. Manufactured Units:
1. Comply with ANSI/SDI A250.8.
2. Provide glazing stops and gaskets at glazed openings.
a. Typical: Unless noted or detailed otherwise, provide integral stop at interior face;
loose (removable) stops at exterior face, for shop assembly with countersunk tamperproof fasteners.
b. Removable Stops: 3/4-inch deep typical unless noted otherwise. Finish to match steel frames.
3. Provide reinforcing for all surface-applied hardware.
C. Steel Doors:
1. Dimensions: 1-3/4 inches thick x 3 feet wide x 7 feet high.
2. Door Type: Stile and rail construction.
3. Doors: ANSI/SDI A250.8 Level 3, Physical Performance Level A, Model 3 stile and rail, extra heavy-duty, face sheet minimum 16-gauge cold-rolled steel.
4. Finish: Factory finished powder coated.
5. Outward-swinging with full-height glazing and 12-inch-high bottom rail.
D. Steel Frames:
1. Integral panel welded type with mitered corners.
2. Door Frames: ANSI/SDI A250.8 Level 3, minimum 16-gauge cold-rolled steel, full profile weld.
3. Finish: To match door.
4. Material: Minimum 16-gauge sheet steel, cold-rolled, free from scale, pitting and surface defects.
5. Hardware Reinforcement:
a. Provide concealed reinforcement of sheet or bar steel to receive hardware. Drill and tap to template requirements for field installation.
b. Hinge Plates: 7-gauge, 1-1/4 inches x 10 inches minimum size.
c. Reinforcement for Surface Applied Hardware: Minimum 10-gauge.
d. Other Items: Conform to HMMA Standards.
E. Orientation: Optional lefthand/righthand door swing, monitor location, and sidelight for ADA models orientation/layout must be available for selection by CDCR Representative, based on specific location(s) of installation.
2.10 SIDELIGHTS
A. Where provided, full-height glazed sidelights shall have 3-inch stiles, 6-inch bottom rail, and 3-inch top rail.
CDCR- SDD 20251020 12 64 13 – 6
2.11 GLAZING
A. Minimum 15/32-inch monolithic abrasion-resistant clear non-reflective polycarbonate sheet glazing glass per ASTM C1349.
1. Grade 4 per ASTM F1915.
2. UV resistant.
3. Flame spread rating of insulation materials must not exceed 25, smoke density must not exceed 450 per ASTM E84.
2.12 HARDWARE
A. Pull handle on exterior side of door: Minimum 3/4-inch-diamter, US32D stainless steel, 8-inch center-to-center.
B. Recessed 14-gauge 304 stainless steel pull handle on interior side of door.
C. Hinges: Full mortise, minimum 14-gauge 304 stainless steel, continuous full-height.
D. Passage roller latch: Full mortise heavy-duty stainless steel body and roller.
E. Continuous acoustical door seal.
2.13 STOOL
A. General:
1. 12-inch-diameter seat material to be minimum 14-gauge stainless steel, #4 finish. 17-inches to 19-inches seat height. Post and base may be stainless steel or powder coated paint.
2. Secure stool to floor with minimum (4) stainless steel machine bolts with acorn nuts set with threadlocker.
3. Stool must not include a restraint ring.
B. Acceptable Manufacturers/Products, as listed below and meeting the criteria and requirements specified herein:
1. Acorn; Model ASF2429.
2. Britex; Model US-STLF.
3. Britex; Model US-STLR.
4. G2 Kryptomax; Model KM-FMS.
5. G2 Kryptomax; Model KM-FMS-EC.
6. Norix; Model S561-120.
7. For manufacturers/products not listed, comply with substitution requirements in Section 01 25 00 – Substitution Procedures.
CDCR- SDD 20251020 12 64 13 – 7
2.14 DESK
A. On same wall as videoconference device outlet, booth to be provided with 1/4-inch-thick x 10-inch-high x width of booth steel backing plate installed centerline at 25 inches above finish floor for optional future OFOI desk. Backing plate to be welded to steel framing members.
2.15 EXHAUST
A. Provide exhaust fan capable of minimum 55 CFM and minimum 14-gauge supply air transfer grille. Fan to discharge to adjacent space.
2.16 LIGHTING
A. Recessed LED lighting:
1. Lens: Security type with clear tempered glass.
2. Mounting: Recessed.
3. Finish: Polyester powder coat.
4. LED Module: Serviceable LED array. Minimum 80 CRI standard.
5. Controls: Toggle switch on exterior of booth.
2.17 TELECOMMUNICATIONS
A. Network Switch Enclosure:
1. Provide network switch in outdoor enclosure. Enclosure shall be equipped with fan system.
2. Network switch shall be equipped with two gigabit SFP fiber incoming ports, and eight giga ethernet output ports. Coordinate with CDCR for network switch model and type.
B. Ethernet:
1. Provide two data outlets with RJ-45 ports inside the shelter/booth.
2. Provide four CAT 6 copper cables from each RJ-45 port to the network switch. Terminate in network switch.
3. All CAT 6 wiring shall be routed in metallic conduit. Wiring installed outside conduit is prohibited.
2.18 SWITCHES
A. Provide toggle type manual switches to control the branch circuits for lighting and exhaust system.
B. Manual switches shall be installed outside of the booth on the same end as the computer or data components. Do not locate on the front of the booth.
C. Automatic controls for lighting systems are prohibited.
CDCR- SDD 20251020 12 64 13 – 8
2.19 VIDEOCONFERENCE DEVICE
A. Booth to be provided with Cisco DX80 VESA mount adapter and wall bracket securely attached to wall panel stud or backing of adequate strength to prevent vandalism.
B. CDCR will provide and install a Cisco Desk videoconference device to the booth manufacturer installed bracket.
PART 3 EXECUTION
3.1 EXAMINATION
A. The installer must verify that project conditions are suitable before beginning installation of booth.
3.2 INSTALLATION
A. Booths shall be installed level, located individually together in accordance with approved drawings or the CDCR Representative.
3.3 ADJUSTMENT
A. Adjust doors for smooth and balanced movement through full swing (170 degrees).
B. Adjust doors for proper interior operation, free from binding, sticking, sagging, or other defects.
Doors must operate freely with no binding or displacement of frame or hardware.
3.4 TOUCH-UP AND CLEANING
A. Clean and restore soiled surfaces. Remove scraps and debris, and leave site in a clean condition.
B. Primed or painted surfaces which have been scratched or otherwise marred during installation, cleaning, including marks caused by spreader removal, must promptly be finished smooth, cleaned, treated for maximum paint adhesion, and touched up with specified primer and finish paint to match.
END OF SECTION
SECTION 12 64 13