11559806-24365-1155-9806 MIL-E-23765-1 weld electrode rods.pdf

Military Specification PDF 84 KB Posted

Attached to
ELECTROD
Solicitation number
SPMYM2-21-Q-1827
Issued by

View the file

Other versions and copies of MIL-E-23765-1

File Revision Posted Attached to
11441207-31851-1144-1207- MIL-E-23765-1 weld electrode rods.pdf Revision not stated ELECTROD

Who attaches MIL-E-23765-1

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MATERIAL ORDERING DATA

MIL-E-23765

IDN: N4523A 1155-9806

ICN: 38RTC99231 KO: S02 KOI: 052

MIL-E-23765B Paragraph 6.2 Ordering Data (general specification)

a. Title, number, and date of this specification: MIL-E-23765B, Electrodes and Rods - Welding, Bare, Solid and Alloy Cored; General Specification for, dated 22 August 1985, Including Amendment 1, Dated 15 September 1989

b. Title, number and date of the applicable detail specification: MIL-E-23765/1E, Electrodes and

Rods - Welding, Bare, Solid and Alloyed Cored, Ordinary Strength and Low Alloy Steel, dated 23 August 1985, Including Amendment 1, Dated 15 September 1989

c. Type: 70S-3 Form: Form 3b - Electrode on large spool (12-in flange) Size: .045 inch

d. Whether First Article Test is required: No

e. Whether alloy identity testing of each electrode or rod after final marking is required:No

f. Length of rods required: N/A

g. Level of packaging and packing required: C

h. Special marking required: Yes Additional Requirements: N/A

MIL-E-23765/1E Paragraph 6.2 Ordering Data (detail specification)

a. Whether the copper and phosphorus content should be restricted: No.

b. If mechanical properties of weld metal as-deposited are other than as specified: No.

c. If neutral granular flux is to be used other than as specified: No.

d. For electrode types MIL-70S-7, -8, and -9, whether the holding time at temperature for the stress relief treatment should be in accordance with 3.4.1.2(a): N/A

e. For electrode types MIL-70S-1, -2, -3, -4, -5, and -6, whether the tests shall be conducted in the stress-relieved condition in accordance with 3.4.1 and 3.4.1.2: N/A And If so whether the holding time at temperature should be in accordance with 3.4.1.2(a) or 3.4.1.2(b): N/A

f. Whether SAW in combination with any neutral granular flux or GMA welding process should be used with item (e) above: N/A.

g. Whether only the argon plus 2 percent oxygen weld test or only the carbon dioxide weld test is required for 70s-2, 70s-3, 70s-4, and 70s-6.

h. Other base metal steel for use in tests, if required: N/A.

MATERIAL ORDERING DATA

MIL-E-23765

i. Level of packing required: C

j. For level A packing, if bags or drums are required: N/A

k. If required, whether bags or drums should be palletized for: N/A

l. If use of polystyrene (loose-fill) material is required shipment: No.

Additional Requirements: Section G, both the argon plus 2 pecent oxygen weld test and the carbon dioxide weld test are required.

Prepared By: F. Gray Code: 250.1