MATERIAL ORDERING DATA
MIL-E-23765
IDN: N4523A 1144-1207
ICN: 38RTC56203 KO: A01 KOI: 001
MIL-E-23765B Paragraph 6.2 Ordering Data (general specification)
a. Title, number, and date of this specification: MIL-E-23765B, Electrodes and Rods - Welding, Bare, Solid and Alloy Cored; General Specification for, dated 22 August 1985, Including Amendment 1, Dated 15 September 1989
b. Title, number and date of the applicable detail specification: MIL-E-23765/1E, Electrodes and
Rods - Welding, Bare, Solid and Alloyed Cored, Ordinary Strength and Low Alloy Steel, dated 23 August 1985, Including Amendment 1, Dated 15 September 1989
c. Type: 70S-3 Form: Other (see Additional Requirements block) Size: .045 inch
d. Whether First Article Test is required: Not Required
e. Whether alloy identity testing of each electrode or rod after final marking is required:Not
Required
f. Length of rods required: N/A
g. Level of packaging and packing required: Level C
h. Special marking required: Special Marking is not Required Additional Requirements: N/A
MIL-E-23765/1E Paragraph 6.2 Ordering Data (detail specification)
a. Whether the copper and phosphorus content should be restricted: Not Required.
b. If mechanical properties of weld metal as-deposited are other than as specified: As Specified.
c. If neutral granular flux is to be used other than as specified: N/A.
d. For electrode types MIL-70S-7, -8, and -9, whether the holding time at temperature for the stress relief treatment should be in accordance with 3.4.1.2(a): N/A
e. For electrode types MIL-70S-1, -2, -3, -4, -5, and -6, whether the tests shall be conducted in the stress-relieved condition in accordance with 3.4.1 and 3.4.1.2: Not Required.
And If so whether the holding time at temperature should be in accordance with 3.4.1.2(a) or 3.4.1.2(b): As Welded Condition Required.
f. Whether SAW in combination with any neutral granular flux or GMA welding process should be used with item (e) above: N/A.
g. Whether only the argon plus 2 percent oxygen weld test or only the carbon dioxide weld test is required for 70s-2, 70s-3, 70s-4, and 70s-6.
h. Other base metal steel for use in tests, if required: Not Required.
MATERIAL ORDERING DATA
MIL-E-23765
i. Level of packing required: N/A
j. For level A packing, if bags or drums are required: N/A
k. If required, whether bags or drums should be palletized for: N/A
l. If use of polystyrene (loose-fill) material is required shipment: N/A.
Additional Requirements: MIL-E-23765B section "C": form is electrode on 11 pound medium spool (8" flange). MIL-E-23765/E section "G": Both the argon plus 2 percent oxygen weld test and the carbon dioxide weld test are required.