About this file

This is a specification document for foodservice equipment procurement by Orange County Public Schools for a Career and Technical Education (CTE) facility renovation project (Project No. 25194-00) at Orange County High School. The specifications detail the requirements for purchasing and installing a comprehensive suite of foodservice equipment including storage units, refrigeration systems, cooking equipment, preparation tables, dishwashing equipment, and related items. The document is Revision 19 of Section 114000 and establishes detailed quality standards, manufacturer qualifications, installation procedures, and product specifications across 63 itemized equipment line items. Prospective bidders must submit written questions regarding any perceived omissions or discrepancies no later than ten days prior to the bid date, and all submittals must be presented as single electronic PDF packages including product data, shop drawings, floor plans, rough-in drawings, and operation and maintenance manuals.

The specifications require that all manufacturers be regularly engaged in producing the designated equipment types with at least ten years of satisfactory service history, and that contractors hold a Class A Virginia Contractor's License. All foodservice equipment must comply with NSF Standards, UL Labels where available, ANSI standards, NFPA codes, ASME Boiler Code requirements, and local health department regulations. Refrigeration compressors carry a five-year warranty from the date of substantial completion covering defective materials and workmanship, with replacement limited to component replacement only. The document emphasizes compliance with high-performance building requirements under Virginia Code 15.2-1804.1 (HB2001) and specifies detailed materials standards including stainless steel fabrications, electrical requirements, and sustainability design requirements. Field installation, testing, start-up procedures, and final closeout procedures including operator training are the responsibility of the foodservice equipment contractor in coordination with other trade divisions.

View the file

Other files

File Type Posted
Culinary Equipment RFP.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ORANGE COUNTY HIGH SCHOOL CTE FACILITY

ORANGE COUNTY PUBLIC SCHOOLS RRMM PROJECT NO.: 25194-00

FOODSERVICE EQUIPMENT (REVISION 19) 114000-1

PART 1 – GENERAL (REVISION 19)

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.

B. Refer to Section 018113 “Sustainable Design Requirements” for sustainable design requirements.

C. Any perceived omission, discrepancy, or ambiguity in Section 11 40 00 Bid Documents shall be questioned by prospective bidders in writing directly to the foodservice consultant no later than ten

(10) days prior to the bid date. An addendum shall be issued to clarify any such issue. Failure to seek such clarification indicates the prospective bidder understands fully the intent of the Bid

Documents.

1.2 DESCRIPTION OF WORK

A. Extent of foodservice equipment work is indicated on drawings and by provisions of this section, including schedules and equipment lists associated with either drawings or this section. The

Foodservice Equipment Contractor shall be responsible for coordinating his work with other trades. The Foodservice Equipment Contractor shall be responsible for all required permits including but not limited to setting equipment and erection of and connection of walk-in refrigeration.

B. Refer to Division 8 sections for “Overhead Coiling Doors/Shutters” for overhead doors or shutters at kitchen.

C. Refer to Division 22 sections for required traps, vents, valves, pipes and pipe fittings, ductwork, and other materials necessary to complete mechanical hookup of foodservice equipment; not work of this section.

D. Refer to Division 26 sections for wiring, disconnects, and other materials necessary to complete electrical hookup of foodservice equipment; not work of this section.

1.3 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Firms regularly engaged in manufacture of foodservice equipment of types, capacities, and sizes required, whose products have been in satisfactory use in similar service for not less than 10 years.

B. Section 11 40 00 Contractor Qualifications: Firms shall hold a Class “A” Virginia Contractor’s

License and be regularly engaged in the distribution of foodservice equipment and brands hereinafter specified.

C. Fabricator’s Qualifications: Where indicated units require custom fabrication, provide units fabricated by a shop which is skilled and has a minimum of 5 years of experience in similar work.

Fabricate all custom equipment items in same shop. Where units cannot be fully shop-fabricated, complete fabrication work at project site. Custom fabrication shall carry both NSF and UL

Custom Certification.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-2

D. Codes and Standards

1. NSF Standards: Comply with applicable National Sanitation Foundation standards and recommended criteria. Provide each principal item of foodservice equipment with a NSF

“Seal of Approval”.

2. UL Labels: Where available, provide UL labels on the completed principal item of foodservice equipment. In addition provide UL “recognized marking” on other items with electrical components, signifying listing by UL, where available.

3. ANSI Standards: Comply with applicable ANSI standards for electric powered appliances and for plumbing fittings including vacuum breakers and air gaps to prevent siphonage in water piping.

4. NFPA Codes: Install foodservice equipment in accordance with the following National Fire

Protection Codes:

a. NFPA 70 – National Electric Code

b. NFPA 96 – “Removal of Smoke & Grease-Laden Vapors from Commercial Cooking

Equipment”

5. ASME Boiler Code: Construct steam generating and closed steam heated equipment to comply with American Society of Mechanical Engineers (ASME) Boiler & Pressure Vessel

Code; Section IV for units not exceeding 15 psig or 250°F, or Section I for higher pressure/temperature units.

6. Health Code: Install foodservice equipment in accordance with local health department applicable requirements.

7. Commonwealth of Virginia Code §15.2-1804.1 “HB2001”: High Performance Building

Requirement for local buildings.

1.4 SUBMITTALS

A. Product Data, Standard Manufactured Models: Submit the latest manufacturer’s specification sheet with a separate cover sheet indicating the item number, specific model number, quantity, accessories and utility information.

B. Shop Drawings, Custom Foodservice Equipment: Provide manufacturer prepared detailed shop drawings drawn at a minimum of 1/2”=1’-0” scale consisting of plan views, elevation, sections and enlarged details as required to illustrate compliance with the drawings and specifications of

Section 11 40 00. Plot manufacturer’s shop drawings at the scale indicated on the shop drawing.

Do not modify scale. Do not include any shop drawings in Equipment Brochure.

C. Required Additional Drawings: Provide separate 1/4”=1’-0 scale floor plan with schedule, 1/4”=1’-0” scale, dimensioned plumbing rough-in drawing with schedule, 1/4”=1’-0” scale, dimensioned electrical rough-in drawing with schedule and 1/4”=1’-0” scale, dimensioned special conditions drawing indicating any floor depressions, floor block outs for floor troughs, wall blocking, wall opening locations and heights, vent collars and any other special condition requiring coordination with other Divisions. Coordinate with the Contractor to determine which building features will be present and are most appropriate for dimensioning reference on rough-ins.

Dimensioned rough-ins shall employ “Baseline” dimensioning style with “Continuing” style used only for minor dimensions such as faucet spacing. Consult equipment specification sheets and shop drawings for leg locations. Avoid leg locations when placing rough-in, particularly floor drains and floor sinks. Verify locations and coordinate correction of all rough-ins prior to floor pouring.

Indicate rough-in for all existing equipment after field verification of required service.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-3

Indicate rough-in for all Owner and Vendor furnished equipment using the Contract

Documents to provide the necessary particulars for those items.

D. All of the above mentioned submittals shall be presented as a single electronic PDF file submittal package. Partial and non-complying submittals shall not be accepted. They shall be returned to the Contractor for correction and resubmittal.

E. Samples for Initial Selection: Submit manufacturer’s color charts showing the full range of colors available for exposed products with color finishes.

F. Maintenance Data: Submit the operation, maintenance, and parts data manuals, in quantities as prescribed by Division 1. O & M Manuals shall be arranged as follows:

1. Manuals shall be presented in a locking 3-ring binder of suitable size to securely hold the information. A cover and spine insert shall indicate the name and address of the facility, the type of Equipment, e.g., Kitchen, Servery, Dishroom, the foodservice equipment contractors full name address, phone number and principal contact person.

2. The first page(s), in a clear plastic protective sleeve(s), shall provide an index of equipment arranged alphabetically by manufacturer’s name. The index shall include the manufacturer’s name, an item description, e.g., “Dishwasher” and the project Item Number. Include the service agents name for each manufacturer and that agent’s 24/7 service phone number.

3. Separate each manufacturer’s manuals from the next with an appropriately labeled index tab.

4. In lieu of paper submission, the above mentioned O&M Manuals may be presented as a single electronic PDF. File shall include a copy of the plan, the equipment schedule, a cover sheet, and complete index. The index shall include the manufacturer’s name, an item description, e.g., “Dishwasher” and the project Item Number. Include the service agents’ name for each manufacturer and that agent’s 24/7 service phone number. The PDF shall be electronically ‘bookmarked’ at each item that has a unique project Item Number. Electronic

O&M Manual shall be page numbered, and page numbers shall correspond to the index. The approved O&M PDF shall be written to a ‘thumb drive’ or similar physical digital file exchange device and shall be delivered to the Owner at the equipment demonstration as described in section 3.05 of these specifications.

5. Partial and non-complying O&M Manuals shall not be accepted.

G. Sustainable Design Submittals:

1. Comply with Section 018113 "Sustainable Design Requirements".

1.5 DELIVERY, STORAGE, AND HANDLING

A. Deliver foodservice equipment in factory-fabricated containers designed to protect equipment and finish until final installation. Make arrangements to receive equipment at project site, or to hold in warehouse until delivery can be made to job site.

B. Foodservice equipment shall be stored in original containers, and in a location that provides adequate protection to equipment while not interfering with other construction operations.

C. Handle foodservice equipment carefully to avoid damage to components, enclosures, and finish.

Do not install damaged foodservice equipment; replace and return damaged components to equipment manufacturer.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-4

1.6 PROJECT CONDITIONS

A. Take field measurements to assure accurate fit of fabricated and buyout equipment.

B. Check utility characteristics; provide pressure regulating valves where required for proper operation of equipment.

1.7 SPECIAL REFRIGERATION WARRANTY

A. Warranty on Refrigeration Compressors: Provide written warranty, signed by manufacturer, agreeing to replace/repair, within warranty period, compressors with inadequate and defective materials and workmanship, including leakage, breakage, improper assembly, or failure to perform as required; provided manufacturer's instructions for handling, installing, protecting, and maintaining units have been adhered to during warranty period. Replacement is limited to component replacement only, and does not include labor for removal and reinstallation.

1. Warranty Period: 5 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 GENERAL REQUIREMENTS

A. It is the intent of these specifications to designate an all-inclusive job, complete and ready for use, except all plumbing, ventilating, and electrical connections made under Division 22, 23 and 26. All equipment shall be set in place completely assembled, jointed together in a workmanlike manner and left ready for the required connections.

B. All equipment shall be permanently and legibly marked, or have a permanent nameplate, with the manufacturer's name. The manufacturer's type, or model number, and the serial number shall also be permanently marked on the machine.

C. All equipment covered by these specifications shall utilize the best and most modern practices of the Foodservice and Cooking Equipment Industry.

D. All specially built equipment shall be made by one manufacturer and shall be uniform throughout as to method and type of construction used.

E. No machinery or equipment covered by these specifications shall be acceptable from any manufacturers who shall not have had equipment of approximately the same type and design as that specified operating successfully for at least one year. Machines installed for test purposes shall not come within the category of successful commercial operation.

F. Appliances shall be new, of manufacturer's current production and furnished complete with motors, driving mechanism, starters and controllers including master switches, timers, cutouts, reversing mechanism, and other electrical equipment, if and as applicable with wiring on the appliance installed in rigid metal conduit (except that flexible conduit may be used as necessary to permit adjustment of motors with drive belts or chain) and permanently connected. Wiring and connection diagrams shall be furnished with electrically operated machines.

G. Appliances shall be of rigid construction, free from objectionable vibration, and quiet in operation.

H. Substitutions may be considered, subject to Owner's approval, only in accordance with the requirements of Division 1 of these specifications, for equipment items included in the Equipment

Schedule. The brands and models indicated in the written specifications are deemed to be the

FOODSERVICE EQUIPMENT (REVISION 19) 114000-5

design standard. Coordination and any corresponding costs incurred by other Divisions due to any substitutions is the responsibility of the Section 11 40 00 contractor.

2.2 ELECTRICAL REQUIREMENTS

A. Supply motors and heating elements for operation and electrical characteristics indicated on contract drawings or as stipulated under Foodservice Equipment Schedule.

B. A cord of suitable length and size shall be provided for all portable items and those usually so connected. Verify characteristics of receptacles being provided under other Sections of these specifications and provide matching plug all completely wired for plug-in operation. Receptacles provided as a part of integral unit of items shall be congruent or match those above.

C. Motors shall be of the drip-proof, splash-proof, or totally enclosed type, having a 2-hour duty cycle and ball bearings (except small timing motors which may have sleeve bearings). All motors shall have windings impregnated to resist moisture. Motors located where subject to deposits of dust, lint, or other similar matter from the machine on which installed shall be of the totally enclosed type. Motors shall have ample power to operate the machines for which designated under full load operating conditions without exceeding their nameplate ratings. Horsepower requirements on driven equipment shall be determined by the manufacturer based on normal operation at maximum capacities. The nominal rated motor horsepower shall be not less than the horsepower required for normal operation of the equipment at maximum capacity.

2.3 MATERIALS

A. General: Unless otherwise indicated on drawings, the following requirements shall apply.

B. Stainless Steel: AISI Type 304. Provide non-magnetic sheets, free of buckles, waves, and surface imperfections. Provide No. 4 polished finish for any surfaces which will be exposed.

C. Galvanized Steel Sheet: ASTM A 526, except ASTM A 527 for extensive forming; ASTM A 525, G90 zinc coating, chemical treatment.

D. Stainless Steel Tube: ASTM A 554, Type 304 with No. 4 polished finish.

E. White Metal: Corrosion-resistant metal containing not less than 21% nickel. Make casting free from pit marks, runs, checks, burrs, and other imperfections; rough grind, polish and buff to bright luster. In lieu of white metal castings, 18-8 stainless steel die-cast or stamped may be used.

F. Plastic Materials and Components: Except for plastic laminate, provide plastic materials and components which comply with NSF 51.

G. Sound Deadening: Heavy-bodied resinous coating, filled with granulated cork or other resilient material, compounded for permanent, non-flaking adhesion to metal in 1/8" thick coating. Apply coating of sound deadening material to underside of tops, drainboards, dishtables, and sinks.

H. Sealants: Provide low VOC sealant that when fully cured and washed meets requirements of Food and Drug Administration Regulation 21 CFR 177.2600 for use in areas where it comes in contact with food. Provide closed cell polyethylene backer rod as required.

1. Adhesives and Sealants applied within the building waterproofing envelope: Comply with low-emitting requirements in Division01 Section “Indoor Air Quality Requirements”.

I. Gaskets: Solid or hollow (not cellular) neoprene or PVC; light gray, minimum 40 Shore A hardness, self-adhesive or prepared for either adhesive application or mechanical anchorage.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-6

J. Fasteners: Shall be stainless steel of a style appropriate for the task. Fasteners shall be Phillips truss head machine screws, Phillips truss head sheet metal screws or Phillips flathead machine screws. Shields and toggles shall be used where necessary to fasten to CMU and concrete. Drive pins are not acceptable foodservice attachment devices.

2.4 STAINLESS STEEL FABRICATIONS

A. General: Unless otherwise indicated on drawings, the following requirements shall apply.

B. Tops: Fabricate of 14-gauge stainless steel, with exposed edges rolled on 1-1/2" diameter radius front and back edges. Ends shall be turned down 90 degrees. Unless otherwise indicated in the

Itemized Specifications where tops are adjacent to walls or adjoining equipment, turn up 6" and back 2" on 45° angle. Cove horizontal and vertical corners with not less than 3/4” radius.

C. Dishtables and Drainboards: Fabricate of 14-gauge stainless steel with exposed edges formed into

1-1/2" x 180° rolled rim approximately 3" high. Provide built-in pitch of 1/8" per foot minimum.

Provide 10" high backsplashes with 2" return on 45° angle or 1-1/2" diameter rolled rim, as indicated. Construct front rim and backsplash on drainboards with continuous level plane with sink it adjoins. Support drainboards up to 36" in length by 1" diameter stainless steel tube welded to underside of drainboard and leg gusset. Support drainboards 36" and longer with legs. Cove horizontal and vertical corners with not less than 3/4" radius.

D. Prewash Sinks in Soiled Dishtables: Fabricate of 14-gauge stainless steel measuring 20” square and 6” deep unless otherwise indicated in Itemized Specifications. Sinks shall have radius cove corners, a perforated lift-out scrapping basket constructed of 16-gauge stainless steel with 1” 16-gauge stainless steel tubing rack slides/handles and 1” stainless steel legs to facilitate draining. If a disposer is specified a disposer collar weldment, control panel bracket and vacuum breaker hole punch shall be substituted for the scrap basket. The rack slides shall be welded to removable stainless steel angle brackets at each end.

E. Framing: Mount tops on 4" wide x 3/4” high 14-gauge stainless steel “U” channels. Mount dishtables and drainboards on 4" wide x 14-gauge stainless steel “U” channels.

1. Run framework the entire length of unit at the centerline and cross brace at each leg assemble and no more than 48" on center between legs. For dishtables and drainboards, run framing from front to back at each leg location, and run additional channel lengthwise, located at center of table width and secured with a double row of 10-24 stainless steel blind weld studs 12" centers. Provide each stud with suitable stainless steel locking acorn nut.

Tables wider than 30: shall have two rows of “U” channel running the entire length of the table. Weld cross channels to main channels and tack weld all ends to the top.

F. Legs and Cross Rails: Construct legs of 1-5/8" O.D. x 16-gauge stainless steel tubing, with fully enclosed stainless steel bullet shaped adjustable foot with minimum adjustment of 1" up or down without any threads showing. Fasten legs to 4" high stainless steel conical gusset with top completely sealed by means of stainless steel plate. Weld gusset continuously to bottom of unit framing.

G. Inserts: Where cold pans and other inserts are installed in cabinet bases, provide apron full depth of insert and of same material as bodies with reinforced openings as required. Form in openings on all sides.

H. Drawers: Unless otherwise indicated in Itemized Specifications drawers shall be Component

Hardware model S90-0020-N or equal.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-7

I. Shelves: Construct of 14-gauge stainless steel.

1. Bottom Shelves: Extend forward and turn down at front so as to be flush with front facing of cabinet.

2. Fixed Intermediate Shelves: Weld to front stiles and to 14-gauge stainless steel brackets so that shelf is 1" away from back and ends of cabinet.

3. Adjustable Shelves: Channel on all 4 sides, weld corners, and mount on removable stainless steel standards.

J. Open Base Shelving: Construct of 16-gauge stainless steel with edges rolled down on open sides, and 2" turn up with 3/4" radius on rear and ends where adjacent to walls and other equipment.

Neatly notch corners and weld to legs. Reinforce shelving longitudinally with14-gauge stainless steel “U” channel welded to underside. Construct removable shelves as above, but fit over cross rails. Do not exceed shelving sections of 30" long; where one section abuts another, turn down edges 1".

K. Wall Shelves: Construct of 14-gauge stainless steel with 1-1/2” roll on front and exposed ends, and with 2” turn up on back and ends where adjacent to walls or other fixtures. Weld all corners.

Construct wall brackets of 14-gauge stainless steel with 1-1/2” flange at wall and completely welded to underside of shelf. Fasten each bracket to wall with minimum of two fasteners. Fasten shelf to wall bracket by means of studs welded to shelf and suitable stainless steel locking acorn nut. Unless otherwise specified in the Itemized Specification wall shelves shall be mounted 64”

AFF to the work surface.

L. Overshelves: Set shelves mounted over equipment not adjacent to walls on 1" x 14-gauge stainless steel tubular standards fitted with stainless steel base flanges. Completely weld top of tubular standard to 14-gauge stainless support channels, run channels full width of overshelf. Run 1/2" steel tension rods through counter tops and reinforcing angle framing, secure with nuts and lockwashers to assure stable sway-free structure. Unless otherwise specified in the Itemized

Specifications overshelves shall be mounted 64” AFF to the work surface

1. Where shelves are mounted over drainboards or dishtables, mount on upturned rolled edges omitting flanges, and scribe lower end of tube to match contour of roll.

M. Wall Mounted Pot Racks: Construct of 3/16” x 2” stainless steel bar stock with double-bar construction. Supply 16-gauge stainless steel end/wall brackets. Provide stainless steel double-pronged pot hooks – one every 12”.

N. Table Mounted Pot Racks: Construct of 3/16” x 2” stainless steel bar stock with triple-bar construction. 1-5/8” tubular stainless steel supports. Provide stainless steel double-pronged pot hooks – one every 12”. Mount 90” AFF to top of rack.

O. Sinks: Fabricate from 14-gauge stainless steel with interior corners rounded to 3/4" radius, both horizontally and vertically, forming cove in bottom. Construct with butt edge joints, welded and ground smooth so no evidence of welding shall appear. Divide multiple compartment sinks with double wall 14-gauge stainless steel partitions rounded to 1/2" radius on top and having corners rounded same as other corners in sinks, continuously welded in place with welds ground smooth and polished. Provide back, bottom, and front of one continuous piece with no overlapping joints or open spaces between compartments. Pitch bottom of each compartment, and crease to die-stamped recess to receive lever type drain, without use of solder, rivets, or welding.

1. Finish front and exposed ends of sink with 1-1/2", 180° rolled edge. Finish back and ends adjacent to walls or other fixtures with backsplash. Punch back backsplash to receive wall-mounted faucets.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-8

2. For sinks in worktops, construct as above but omit roll edges and backsplash. Fabricate bowls to be flush with work surface.

2.5 MILLWORK/STAINLESS STEEL FABRICATION

A. General: Unless otherwise indicated on drawings, the following requirements shall apply.

B. Tops: Shall be fabricated from 30cm thick quartz material of the highest grade or as specified in the itemized specifications. Installation shall be performed by manufacturer trained and certified installers using the manufacturer’s specific guidelines for the particular installation. Top shall be reinforced with a stainless steel or galvanized sub top or framing as recommended by the top material manufacturer with extra bracing at locations of cutouts for drop-in equipment and where large countertop equipment shall be placed.

C. Customer side horizontal surfaces (for example a plate shelf beneath top): Shall be constructed of the same material as the top unless described differently in the itemized specifications.

D. Cabinet bodies: shall be constructed of fully welded 18-gauge stainless steel reinforced with stainless steel 14-gauge hat channel on the underside of all tops and shelves.

E. Legs and casters: Shall be as indicated in the itemized specifications. Stainless steel legs shall be a minimum of 6” high with a stainless steel adjustable foot. Casters shall be 5” diameter heavy duty plate casters with brakes attached to the hat channel underbracing of the cabinet body.

F. Toe plate: Shall be securely attached with stainless steel machine screws to stainless steel brackets attached to the underbody of the cabinet. Material and finish of the toe plates shall be specified in the itemized specifications.

G. Millwork façade: Shall be constructed of cabinet grade ¾” plywood of species wood with wood trim and finish as indicated on the itemized specifications or laminated with high pressure laminate

(HPL) as indicated in the itemized specifications. The rear of laminated panels shall be laminated in a cleanable material matching the expansion and contraction specifications of the exposed HPL.

Panels shall be attached in a secure concealed manner while remaining removable for replacement in the future. Plywood and all laminating glues shall be free of added urea-formaldehyde.

H. Doors: Shall be as described in the itemized specifications constructed of cabinet grade ¾” plywood fitted with Blum Concealed hinges and Component Hardware pulls. Where necessary provide doors with louver cuts to properly ventilate refrigeration condensing units. Plywood and all laminating glues shall be free of added urea-formaldehyde.

I. Cutouts and special features: Shall be coordinated with and accommodate the associated equipment regardless of the source of the equipment.

2.6 REMOTE REFRIGERATION EQUIPMENT

A. General: Provide refrigeration condensing units of size and capacities as indicated, consisting of compressors, condensers, receivers, motors, mounting bases, vibration isolators, refrigeration components, safety devices, electrical controls, refrigerant and protective controls; all factory assembled and tested.

B. Refrigeration Specialties: Provide refrigerant dryer, liquid line solenoid valve, suction line filter, expansion valve, and water regulating valve (for water cooled condensers only). Provide pump down control circuits consisting of thermostat and solenoid valve. Maintain box temperature from thermostat and liquid line solenoid valve, control compressor from suction pressure.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-9

C. Leak Testing: After all lines are connected, the entire system shall be leak tested. The complete system shall be pressurized to 150 psig with refrigerant and dry nitrogen (or dry CO2). An electronic type leak detector shall be used to identify leaks. Pressure shall be held for a minimum of 12 hours and then rechecked. Coordinate test observation with the owner’s representative on site.

D. Evacuation: A good, deep vacuum pump shall be connected to both the low and high side evacuation valves with copper tube or high vacuum hoses (1/4” ID minimum). If the compressor has service valves, they shall remain closed. A deep vacuum gauge capable of registering pressure in microns shall be attached to the system for pressure readings. A shut off valve between the gauge connection and vacuum pump shall be provided to allow the system pressure to be checked after evacuation. Do not turn off vacuum pump when connected to an evacuated system before closing shut off valve. The vacuum pump shall be operated until pressure of 1,500 microns absolute pressure is reached – at which time the vacuum shall be broken with the refrigerant to be used in the system through a drier until the system pressure rises above 0 psig. Repeat this operation a second time. Open the compressor service valves and evacuate the entire system to 500 microns absolute pressure. Raise the pressure to 2 psig with the refrigerant and remove the vacuum pump.

E. Refrigeration Line Insulation: Refrigeration lines shall be insulated with Aeroflex USA Aerocel

White/Gray 25/50 pipe insulation. Thickness of insulation shall be in accordance with insulation manufacturer’s recommendation. Butt joints and seams shall be sealed with contact adhesive.

PART 3 - EXECUTION

3.1 INSPECTION

A. Rough-In Work: Examine roughed-in plumbing, mechanical and electrical services, and installation of floors, walls, columns and ceilings, and other conditions under which foodservice work is installed; verify dimensions of services and substrates before fabricating work. Notify

Contractor of unsatisfactory locations and dimensions of other work, and of unsatisfactory conditions for proper installation of foodservice equipment. Do not proceed with fabrication and installation until unsatisfactory dimensions and conditions have been corrected.

3.2 INSTALLATION

A. General: Set each item of non-mobile and non-portable equipment securely in place, level and adjust to correct height. Anchor to supporting substrate where indicated and where required for sustained operation and use without shifting or dislocation. Conceal anchorages where possible.

Adjust counter tops and other work surfaces to level tolerance of 1/16" maximum offset, and maximum variation from level or indicated slope of 1/16" per ft. Height of tops and work surfaces shall not exceed 2’-10” AFF.

B. Field Joints: Complete field-assembly joints in work (joints which cannot be completed in shop) by welding, bolting-and-gasketing, or similar methods. Grind welds smooth and restore finish. Set or trim gaskets flush, except for “T” gaskets as indicated.

C. Closure Plates and Strips: Install, with joints coordinated with units of equipment.

D. Cut-Outs: Provide cut-outs in foodservice equipment to run plumbing, electric, or steam lines through equipment items for final connections.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-10

E. Sealants and Gaskets: Install all around each unit to make joints air-tight, watertight, vermin-proof, and sanitary for cleaning purposes. In general, make sealed joints not less than 1/8" wide, and stuff backer rod to shape sealant bead properly, at 1/4" depth. Shape exposed surfaces of sealant slightly concave, with edges flush with faces of materials at joint. At internal-corner joints, apply sealant or gaskets to form a sanitary cove, of not less than 3/8" radius. Provide sealant-filled or gasketed joints up to 1/4" joint width; stainless steel closure strips for wider joints, with sealant application each side of strips. Anchor gaskets mechanically or with adhesives to prevent displacement.

F. Piping: Install necessary piping from relief valves on kettles and steamers to exhaust in manner to avoid steam coming in contact with operating personnel, and in accordance with applicable codes.

Install required piping from indirect drain connections to floor drains.

G. Custom Sink Faucets: For single compartment sinks mount faucet over center line; for double compartment sinks center faucet over partition; for triple compartment sinks mount two faucets, one over each partition.

3.3 FIELD QUALITY CONTROLS

A. Testing: Do not start-up foodservice equipment until service lines have been tested, balanced, and adjusted for pressure, voltage, and similar considerations; and until water and steam lines have been cleaned and treated for sanitation. Before testing, lubricate each equipment item in accordance with manufacturer's recommendations.

B. Test each item of operational equipment to demonstrate that it is operating properly, and that controls and safety devices are functioning. Repair or replace equipment which is found to be defective in its operation, including units which are below capacity or operating with excessive noise or vibration.

3.4 CLEANING

A. After completion of installation, and completion of other major work in foodservice areas, remove protective coverings, if any, and clean foodservice equipment, internally and externally. Restore exposed and semi-exposed finishes to remove abrasions and other damages; polish exposed-metal surfaces and touch-up painted surfaces. Replace work which cannot be successfully restored.

B. Final Cleaning: After testing and start-up, and before time of Substantial Completion, thoroughly clean foodservice equipment, and leave in condition ready for sanitizing by foodservice personnel.

C. Any cleaning agents that are acid based, contain bleach, or other caustic agents or chemicals not specifically approved for use on stainless steel SHALL BE STRICTLY FORBIDDEN IN ALL

FOODSERVICE SPACES. Failure to observe this will result in permanent damage to stainless steel equipment and stainless steel components and will VOID manufacturers’ warranties. Section

114000 shall inform the General Contractor of its responsibility to enforce this requirement.

3.5 CLOSEOUT PROCEDURES

A. Provide services of Installer’s technical representative, and manufacturer's technical representative, to instruct Owner's personnel in operation and maintenance of foodservice equipment.

B. Schedule training with Owner, provide 7-day notice to Contractor and Architect of training date.

FOODSERVICE EQUIPMENT (REVISION 19) 114000-11

PART 4 - ITEMIZED EQUIPMENT SPECIFICATIONS

ITEM NO. 1 – AIR SCREEN INSECT FAN

Air Screen Insect Fan shall be Berner Model No. CHD10-1042A-L003 Provide the following options:

Manufacturer’s Standard Features and Automatic plunger door switch Coordinate mounting of door switch with Division 26 on STRIKE side of door where indicated on Drawing QF103

ITEM NO. 2 – DRY STORAGE SHELVING UNIT

Dry Storage Shelving Unit shall be Metro Model No. Super Erecta Metroseal-3-L003, sized and arranged as indicated on Drawing QF101 Provide the following options:

Manufacturer’s Standard Features and Fourteen (14) post clamps Each section shall consist of five (5) shelves and four (4) 74” posts. Install bottom shelf at 8” AFF and subsequent shelves 16” above the one beneath to surface. Install post clamps above the top shelf to adjacent front posts where possible and rear posts where not possible on front posts.

ITEM NO. 3A – DUNNAGE RACK

Dunnage Rack shall be Metro Model No. HP2248PD-L003 Provide the following options:

Manufacturer’s Standard Features

ITEM NO. 3B – DUNNAGE RACK

Dunnage Rack shall be Metro Model No. HP2236PD-L003 Provide the following options:

Manufacturer’s Standard Features

ITEM NO. 4 – STORAGE CABINET

Storage Cabinet shall be IMC Teddy Model No. SC-1830HS-L003 Provide the following options:

Manufacturer’s Standard Features and One (1) #DRL-2P door lock One (1) #EXSH shelf

ITEM NO. 5 – STORAGE CABINET

Storage Cabinet shall be IMC Teddy Model No. SC-1860HS-L003 Provide the following options:

Manufacturer’s Standard Features and One (1) #DRL-2P door lock One (1) #EXSH shelf

ITEM NO. 6 – SHELVING UNIT

Shelving Unit shall be Metro Model No. Super Erecta Metroseal-3-L003, sized and arranged as indicated on Drawing QF101 Provide the following options:

Manufacturer’s Standard Features and One (1) post clamps

FOODSERVICE EQUIPMENT (REVISION 19) 114000-12

Each section shall consist of five (5) shelves and four (4) 74” posts. Install bottom shelf at 8” AFF and subsequent shelves 16” above the one beneath to surface. Install post clamps above the top shelf

ITEM NO. 7 – WALK-IN SHELVING UNIT

Walk-in Shelving Unit shall be Metro Model No. Super Erecta Metroseal-3-L003, sized and arranged as indicated on Drawing QF101 Provide the following options:

Manufacturer’s Standard Features and Four (4) post clamps Each section shall consist of four (4) shelves and four (4) 74” posts. Install bottom shelf at 8” AFF and subsequent shelves 19” above the one beneath to surface. Install post clamps above the top shelf

ITEM NO. 8 – STORAGE CABINET WITH SLIDING DOORS

Storage Cabinet with Sliding Doors shall be Eagle Model No. PCS1872SE-CS-L-L003 Provide the following options:

One (1) Door lock per section

ITEM NO. 9 – PORTABLE UTILITY CART

Portable Utility Cart shall be Lakeside Model No. 544-L003 Provide the following options:

Manufacturer’s Standard Features

ITEM NO. 10 – PORTABLE PAN STORAGE RACK

Portable Pan Storage Rack shall be Metro Model No. Super Erecta, Metroseal 3-L003, sized and arranged as indicated on QF101 Provide the following options:

Manufacturer’s Standard Features and Each unit shall consist of one (1) D55JN truck dolly, four (4) wire shelves, four (4) 63” posts. Install bottom shelf in lowest position and subsequent shelves spaced evenly to top of posts.

ITEM NO. 11 – NESTING SHEET PAN RACK

Nesting Sheet Pan Rack shall be Channel Model No. 402SN-L003 Provide the following options:

Manufacturer’s Standard Features

ITEM NO. 12 – PEDESTAL HAND SINK WITH FOOT VALVES

Pedestal Hand Sink with Foot Valves shall be Eagle Model No. HSA-10-FA-P-L003 Provide the following options:

One (1) T&S Brass #B-0502 double pedal floor mounted valve in lieu of standard

ITEM NO. 13 – ADA HAND SINK

ADA Hand Sink shall be Eagle Model No. HSAP-14-ADA-FW-L003 Provide the following options:

Mount at 34” AFF to top of sink

ITEM NO. 14 – PREP TABLE WITH SINKS

FOODSERVICE EQUIPMENT (REVISION 19) 114000-13

Prep Table with Sinks shall be Eagle Model No. T3084SEM-BS-L003, sized and arranged as indicated of Drawing QF101 Provide the following options:

Manufacturer’s Standard Features and 10” high backsplash Marine edge top Omit undershelf where indicated on Drawing QF101 One (1) #502946 NSF listed fully-enclosed stainless steel drawer assembly Two (2) 20” x 20” x 14” deep stainless steel sink bowl One (1) T&S #B-0133-V-B prerinse faucet with wall bracket and vacuum breaker One (1) T&S #B-0156 add-on faucet Two (2) T&S #B-3952-01 twist waste valve with overflow assembly Two (2) welded stainless steel twist waste rod support tab Fully welded legs, crossrails, and undershelf

ITEM NO. 15 – MANUAL CAN OPENER

Manual Can Opener shall be Edlund Model No. S-11-L003 Provide the following options:

Manufacturer’s Standard Features

ITEM NO. 16 – MICROWAVE OVEN

Microwave Oven shall be Panasonic Model No. NE-1025F-L003 Provide the following options:

Manufacturer’s Standard Features

ITEM NO. 17 – MICROWAVE SHELF

Microwave Shelf shall be Eagle Model No. MWS1824-L003 Provide the following options:

Mount at 60” AFF to top of shelf

ITEM NO. 18 – 20-QUART MIXER

20-Quart Mixer shall be Globe Model No. SP20-L003 Provide the following options:

Manufacturer’s Standard Features

ITEM NO. 19 – PORTABLE EQUIPMENT STAND

Portable Equipment Stand shall be Lakeside Model No. 518-L003 Provide the following options:

Manufacturer’s Standard Features

ITEM NO. 20 – 5-QUART MIXER

5-Quart Mixer shall be Globe Provide the following options:

One (1) #MC-SP5 mixer cover

ITEM NO. 21A – COFFEE/TEA BREWER

Coffee/Tea Brewer shall be Bunn Model No. 52300.0100-L003 Provide the following options:

FOODSERVICE EQUIPMENT (REVISION 19) 114000-14

One (1) #53463.0038 coffee funnel assembly, black One (1) #53463.0039 tea funnel assembly, natural Two (2) #42750.0200 brew thru thermal server Two (2) #39600.0001 beverage dispenser

ITEM NO. 21B – COFFEE/TEA BREWER WATER FILTER

Coffee/Tea Brewer Water Filter shall be Everpure Model No. QC7I SINGLE 4FC5-S-L003 Provide the following options:

Manufacturer’s Standard Features and One (1) #EV969331 water filter cartridge Mount at 60” AFF to top of filter

ITEM NO. 22 – WALL MOUNT KNIFE HOLDER

Wall Mount Knife Holder shall be Edlund Model No. KLC994-L003 Provide the following options:

Mount at 54” AFF to bottom of holder

ITEM NO. 23 – WORKTABLE

Worktable shall be Eagle Model No. T3072SE-BS-L003, sized and arranged as indicated on Drawing

QF101

Provide the following options:

Manufacturer’s Standard Features and One (1) #502946 NSF listed fully-enclosed stainless steel drawer assembly

ITEM NO. 24 – BEVERAGE COUNTER

Beverage Counter shall be Eagle Model No. T3072SE-BS-L003, sized and arranged as indicated on Drawing QF101 Provide the following options:

Manufacturer’s Standard Features and Omit undershelf where indicated on Drawing QF101 One (1) #502946 NSF listed fully-enclosed stainless steel drawer assembly One (1) 14” x 16” x 9-1/2” deep stainless steel sink bowl One (1) #313304 deck mount faucet

ITEM NO. 25 – PORTABLE WORKTABLE

Portable Worktable shall be Eagle Model No. T3060SE-L003, sized and arranged as indicated on Drawing QF101 Provide the following options:

Manufacturer’s Standard Features and One (1) #E15 tray divider located at end of undershelf typical One (1) #CAHW4-SB set of (4) casters Fully welded legs and undershelf

ITEM NO. 26 – PORTABLE ADA WORKTABLE

Portable ADA Worktable shall be Eagle Model No. T3060STE-L003, sized and arranged as indicated on Drawing QF101

FOODSERVICE EQUIPMENT (REVISION 19) 114000-15

One (1) #E17 special height legs One (1) #CAHW4-SB set of (4) casters Fully welded legs and crossrails Modify finish height to 34” AFF to comply with ADA

ITEM NO. 27 – DEMONSTRATION TABLE WITH MIRROR – OWNER FURNISHED, OWNER

INSTALLED

ITEM NO. 28 – WORKTABLE

Worktable shall be Eagle Model No. T2436SE-L003 Provide the following options:

Fully welded legs and undershelf

ITEM NO. 29 – PORTABLE HEATED CABINET

Portable Heated Cabinet shall be Winston Model No. HOV5-14UV-L003, hinged as indicated on QF101 Provide the following options:

Full-perimeter bumpers with casters, 2 locking

ITEM NO. 30 – 1-SECTION REACH-IN FREEZER

1-Section Reach-In Freezer shall be Continental Model No.1FNSS-L003, hinged as indicated on Drawing

QF101

Provide the following options:

Manufacturer’s Standard Features and Stainless steel back Two (2) additional epoxy coated shelves One (1) hasp lock

ITEM NO. 31 – 2-SECTION REACH-IN FREEZER

2-Section Reach-In Freezer shall be Continental Model No. 2FNSS-L003, hinged as indicated on Drawing QF101 Provide the following options:

Manufacturer’s Standard Features and Stainless steel back Four (4) additional epoxy coated shelves One (1) hasp lock

ITEM NO. 32A, B, & C – WALK-IN COOLER

Walk-in Cooler shall be Bally Model No. CUSTOM, shaped as indicated on Drawing QF101, 10’–7- 1/2” wide x 7’–3-1/4” deep front-to-back x 8’–6” high overall.

Provide reinforced floor with diamond tread aluminum overlay. Provide internal ramp with diamond tread aluminum floor.

Cooler shall be finished in .040 stucco embossed aluminum in/out where exposed with white stucco embossed ceiling. Provide each compartment with a 36” wide x 84” high door where indicated, equipped with 1/8” diamond tread kick plates inside and out, doors and frames to 36” AFF.

Provide door with Kason Series hardware finished in polished chrome, 77CL-4C positive latch with cylinder locks, 1248-4 cam-lift self-closing hinges, and 1097M spring assist closer. Provide minimum 14” x 14” heated view windows in door. Provide vinyl strip curtains at door opening.

Provide 12-gauge stainless steel threshold plate with thermostatically controlled heater for cooler door. Install door stop as necessary. Trim Cooler with matching aluminum closures to walls and

FOODSERVICE EQUIPMENT (REVISION 19) 114000-16

ceiling. Furnish and mount one (1) additional Kason 1810LCT LED light fixture where indicated on Drawing QF103. Coordinate connection of lights with Division 26. Provide a “Special Conditions Drawing” with submittal detailing location and size of masonry opening.

Provide HCFC-free air-cooled Condensing Unit Model BEZA007H9-HS2E with matching Unit Cooler Model BLP108MA-S1E for the medium temperature compartment. Mount Condensing Unit and hang Unit Cooler where indicated on Drawing QF103. Provide low ambient kit and UL listed weather cover. Provide leak detection within unit cooler(s) interconnected to refrigeration cut-off valves in all refrigeration lines. The refrigerant line cut-off valves shall be located outside of the walk-in compartments, located where indicated on Drawing QF103, no farther than 20’ from unit cooler(s) complying with ASHRAE 15. Connection of refrigeration and drain lines shall be by a licensed refrigeration technician using refrigeration grade hard copper following the manufacturer’s and ASHRAE guidelines under Section 114000. All copper tubing shall be soldered, no shark bite fittings shall be used. Wrap all condensate drain lines with heat tape where exposed to freezing temperatures. Verify distance of refrigeration line runs and adjust line size and condensing unit size to conform to manufacturer’s recommendations.

After all lines are connected, the entire system shall be leak tested. The complete system shall be pressurized to 150 psig with refrigerant and dry nitrogen (or dry CO2). An electronic type leak detector shall be used to identify leaks. Pressure shall be held for a minimum of 12 hours and then rechecked. Coordinate test observation with the owner’s representative on site.

A good, deep vacuum pump shall be connected to both the low and high side evacuation valves with copper tube or high vacuum hoses (1/4” ID minimum). If the compressor has service valves, they shall remain closed. A deep vacuum gauge capable of registering pressure in microns shall be attached to the system for pressure readings. A shut off valve between the gauge connection and vacuum pump shall be provided to allow the system pressure to be checked after evacuation. Do not turn off vacuum pump when connected to an evacuated system before closing shut off valve.

The vacuum pump shall be operated until pressure of 1,500 microns absolute pressure is reached – at which time the vacuum shall be broken with the refrigerant to be used in the system through a drier until the system pressure rises above 0 psig. Repeat this operation a second time. Open the compressor service valves and evacuate the entire system to 500 microns absolute pressure. Raise the pressure to 2 psig with the refrigerant and remove the vacuum pump.

Refrigeration lines shall be insulated with Aeroflex USA Aerocel White/Gray 25/50 pipe insulation.

Thickness of insulation shall be in accordance with insulation manufacturer’s recommendation.

Butt joints and seams shall be sealed with contact adhesive.

ITEM NO. 33 – ICE MAKER WITH BIN

Ice Maker with Bin shall be Hoshizaki Model No. KM-322MAK-L003 Provide the following options:

Manufacturer’s Standard Features and One (1) #B-500SF ice bin One (1) #HS-2033 top kit One (1) #LP-6 FLANGE LEG set of (4) stainless steel flange legs One (1) #HS-5607 scoop holder kit

ITEM NO. 34 – ICE MAKER WATER FILTER

Ice Maker Water Filter shall be Everpure Model No. EV932401-L003

FOODSERVICE EQUIPMENT (REVISION 19) 114000-17

One (1) #EV961222 water filter cartridge Mount at 60” to top of filter

ITEM NO. 35A – EXHAUST HOOD WITH PSP

Exhaust Hood with PSP shall be CaptiveAire Model No. 6624 ND-2-PSP-F-L003, sized and arranged as indicated on Drawing QF101 and as detailed on Drawings QF301-QF302

ITEM NO. 35B – EXHAUST HOOD WITH PSP

Exhaust Hood with PSP shall be CaptiveAire Model No. 6624 ND-2-PSP-F-L003, sized and arranged as indicated on Drawing QF101 and as detailed on Drawings QF301-QF302

ITEM NO. 35C – FIRE SUPPRESSION SYSTEM

Fire Suppression System shall be CaptiveAire Model No. TANK FS 4.0/4.0/4.0-L003, as indicated on Drawing QF101 and as detailed on Drawings QF301-QF302

ITEM NO. 35D – FAN CONTROL PANEL

Fan Control Panel shall be Captive-Aire Model No. DCV-1111-L003, as indicated on Drawing QF101and as detailed on Drawings QF301-QF302

ITEM NO. 35E – EXHAUST FAN – REFER TO DIVISION 23

ITEM NO. 35F – MAKE UP AIR FAN – REFER TO DIVISION 23

ITEM NO. 35G – ROOM TEMPERATURE MONITOR – INCLUDED IN ITEM NO. 35D

ITEM NO. 35H – REMOTE FIRE SUPPRESSION ACTUATION DEVICE – INCLUDED IN ITEM

NO. 35C

ITEM NO. 36 – DOUBLE DECK CONVECTION OVEN

Double Deck Convection Oven shall be Southbend Model No. PCG140B/TD-L003 Provide the following options:

Manufacturer’s Standard Features and One (1) set of (4) 6” casters One (1) Dormont #1675KITCF2S48 ¾” gas connector kit One (1) Eagle #CC-S-2 caster cradles

ITEM NO. 37 – 6-PAN COMBI OVEN ON STAND

6-Pan Combi Oven on Stand shall be Rational Model No. ICC 6-HALF LP 120V 1 PH (LM200BG)- L003 Provide the following options:

Manufacturer’s Standard Features and K-12 Extended warranty Chef Assistance Program Certified installation One (1) #8720.1560US installation kit One (1) #1900.1159US water filtration system One (1) #56.01.535 cleaner tabs One (1) #60.31.103 mobile oven stand One (1) Dormont #RDC48 restraining cable One (1) pair Eagle #CC-S-2 caster cradles

FOODSERVICE EQUIPMENT (REVISION 19) 114000-18

ITEM NO. 38 – 6-BURNER RANGE

6-Burner Range shall be Garland Model No. GFE36-6C-L003 Provide the following options:

Manufacturer’s Standard Features and One (1) set of (4) adjustable height casters with front brakes

ITEM NO. 39 – 1-BANK FRYER WITH BUILT-IN FILTER

1-Bank Fryer with Built-In Filter shall be Frymaster Model No. FPH155-L003 Provide the following options:

Manufacturer’s Standard Features and Cord and Nema 5-15p plug One (1) #8030170 filter paper One (1) #8030429 fryer brush One (1) #8030197 clean-out rod One (1) #8239426 full pot cover One (1) #8233938 crumb scoop

ITEM NO. 40 – WALL MOUNT POT FILLER

Wall Mount Pot Filler shall be T&S Brass Model No. B-0592-LVR-L003 Provide the following options:

Mount at 50” AFF to top of faucet

ITEM NO. 41 – 24” GRIDDLE

24” Griddle shall be Southbend Model No. HDG-24-L003 Provide the following options:

ITEM NO. 42 – 24” CHARBROILER

24” Charbroiler shall be Southbend Model No. HDC-24-L003 Provide the following options:

Manufacturer’s Standard Features and Battery spark ignition

ITEM NO. 43 – REFRIGERATED EQUIPMENT STAND

Refrigerated Equipment Stand shall be Continental Model No. D48GN-L003 Provide the following options:

Manufacturer’s Standard Features and Integral heat shield Cylinder lock (per door/drawer)

ITEM NO. 44 – POT SINK

Pot Sink shall be Eagle Model No. FN2860-3-14/3-L003, sized and arranged as indicated on Drawing

QF101

FOODSERVICE EQUIPMENT (REVISION 19) 114000-19

One (1) T&S #B-0290 big flo faucet One (1) T&S #B-0287-MOD big flo pre-rinse unit One (1) T&S #B-109-02 wall bracket One (1) T&S #B-0970-FE atmospheric back flow preventer One (1) T&S #002535-25 3/8” NPT close nipple One (1) T&S…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .