This document is a set of Questions and Answers related to a federal contract opportunity for repairs needed at the Eastside and Westside Wastewater Treatment Plants (WWTPs). The Q&A provides details on the pumps, piping, and control systems at the Westside WWTP Influent Pump Station and the Westside WWTP Equalization Basin. It also clarifies the scope of work, including replacement of corroded pipes and pumps, and notes that the Option Services should not be bid at this time.
The related federal contract opportunity is for a solicitation to 1) investigate issues at the Eastside and Westside WWTP Influent lift stations and other facilities, and 2) replace two of the three pumps at the Westside WWTP equalization basin. The contract will have two line items - a lump sum for the investigation and pump replacement, and an option CLIN for repairs to the Eastside/Westside WWTP Influent Lift Stations. This is a Total Small Business Set-Aside with a 30-day period of performance. Offers are due by April 22, 2024.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Westside WWTP Influent Pump Station Pumps Data Plate 1.jpeg | JPEG file | |
| Westside WWTP Influent Pump Station Pumps Data Plate 2.jpg | JPG image | |
| Terms and Conditions - Revision 16APR2024.pdf | ||
| Terms and Conditions.pdf | ||
| SCA Wage Determination 2015-4281 Rev 28 26DEC2023.pdf | ||
| SOW_Eastside-Westside Clarifiers Repair_Revised.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Question 1: Please elaborate on the “Controls” that are noted for pumps.
Answer 1: Each pump is managed by an electric and control system; the control system is usually part of the plant control system and is usually float controlled. Evaluation/check/investigation shall include the pumps (mechanical), the Motor Control Center (MCC) which represents the electrical as well as the control system for the pumps.
Question 2: Please provide Equalization Pumps model and serial numbers.
Answer 2: Available information as follows:
ABS/Pumpex
3 HP
1700 RPM
3 Phase 460V Type K80F‐VC3‐162 Serial 69757
Question 3: Should the Equalization Basin Pumps’ discharge elbows as well as the railings be replaced?
Answer 3: The discharge elbows are in bad shape and shall be replaced. As far as the railings, if an exact replacement of the pumps is found (pumps are over 30 years old and manufacturer doesn’t seem to be active), then the railing can be reused. If new pumps are used, then the railings shall be replaced to work with the new pumps.
Question 4: How should the Option Services be bid?
Answer 4: DO NOT BID SOW Paragraph 4.0 Option 1. Until the evaluation/check/investigation is complete, the extent of the repair or replacement is unknown. Only the base requirements will be evaluated.
Question 5: Please elaborate on the scope of the Westside WWTP Treatment Unit.
Answer 5: The Air Lift Pump that transfers sludge from the clarifier to the aeration basin discharge 4” pipe as well as the 1½” air pipe are corroded and have holes, the scope will be repair of the holes in the pipe or replacement of these pipes. This unit is up for renovation and it is part of a contract being currently awarded by USACE to an A/E but the requiring activity can’t wait for two years without any redundancy at the plant, so the Air Lift must be repaired.
Question 6: Please provide the model and serial numbers of the Westside WWTP Influent Pump Station
Pumps.
Answer 6: The only information available for model and serial numbers are the data plates on the pumps. Pictures of the data plates have been provided as attachments Westside WWTP Influent Pump
Station Pumps Data Plate 1 and 2. The following information is also available:
The Influent Pump Station consists of two submersible pumps located in a wet well with an adjacent valve vault.
a. Number of Pumps ‐ 2
b. Manufacturer ‐ Pumpex
c. Design Pump Capacity ‐ 530 gpm @ 27 feet of head
d. Discharge Size ‐ 8 inches
e. Efficiency ‐ 79%
f. Pump Speed ‐ 1160 RPM
g. Motor Horsepower ‐ 8.5 HP
h. Maximum Sphere Pump will pass ‐ 4 inches
The wet well and valve vault are each 10 feet in diameter with the wet well approximately 17 feet deep and the valve vault approximately 9 feet deep.
Question 7: Please provide the model and serial numbers of the Westside WWTP Influent Pump Station
Pumps.
Answer 7: Information as follows:
Model: Xylem/Flygt NP3127.070
Location: Pumping Station Wet Well
Serial Numbers: 1950079, 1950080
Tag#: N/A
Manufacturer: Xylem/Flygt Corporation
Weight of an individual unit(s): Xylem/Flygt NP3127.070 Pump 340 lbs.
Nameplate Data: Xylem/Flygt Model NP3127.070, 7.5 HP, 200 Volt, 3 Phase, 426 Impeller
END