11-Drawings.pdf

PDF 11 MB Posted

Attached to
ITB – Major Repairs to Brays Bayou for the Harris County Flood Control District
Solicitation number
25/0370
Issued by
Harris County, Texas

About this file

This is a comprehensive drawing set for Major Repairs to Brays Bayou Project ID D100-00-00-X134, prepared by Huitt-Zollars Inc. for the Harris County Flood Control District (HCFCD). The project encompasses significant rehabilitation work at two primary sites: the Leopold Drive site and the MacGregor site along Brays Bayou in Harris County, Texas. The scope of work includes removal and replacement of existing concrete channel lining, installation of steel sheet pile walls for structural support, repair of earthen slopes, construction of new concrete trails with cement-stabilized subgrades, installation of weep hole drainage systems, and implementation of riprap protection at Grade No. 2. The Leopold site work involves slope repair adjacent to Bayou Parkland on Almeda Road and concrete channel repair, while the MacGregor site requires extensive concrete lining replacement from station 495+67 to 499+91 with a 20-foot minimum bottom width. Construction access will be facilitated through Houston Parks and Recreation maintenance office for the MacGregor site and directly from Leopold Drive for the Leopold site, with temporary stormwater culverts required to cross existing drainage swales. The project drawings indicate an issuance for bidding date of October 31, 2025, with work approval dated October 28, 2025.

The project phasing notes indicate a two-phase construction approach at the MacGregor site to manage water diversion and allow sequential removal and replacement of channel elements. Site preparation requirements include pre-construction photo and video documentation, installation of six-foot chain link fencing on construction access routes through Bayou Parkland, protection of existing public concrete trails with construction fencing, and restoration of all disturbed areas to pre-construction conditions. The detailed specifications reference HCFCD standard specifications for concrete lining (Section 03310), structural excavation and backfill (Section 02316), riprap (Section 02378), and cement-stabilized subgrade (Section 02338). Benchmarks for surveying purposes are provided for both sites, with elevations referenced to NAVD88 Geoid 12B adjustment. The contractor must submit agreements with private property owners and Houston Parks and Recreation per HCFCD General Conditions, and any trail damage incurred during construction must be repaired at no cost to the district. CenterPoint Energy property restrictions apply, requiring advance notification for any activities crossing their fee or easement property.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXECUTIVE DIRECTOR CHRISTINA (TINA) PETERSEN, PHD, P.E.

LESLEY BRIONES

TOM S. RAMSEY, P.E.

ADRIAN GARCIA

RODNEY ELLIS

COUNTY JUDGE LINA HIDALGO

PCT . 1

PCT . 2 PCT . 4

PCT . 3

VICINITY MAP

PROJECT

LOCATIONS

H C

FC

D

P R

O

JE

C T

ID

D

0-

-0 0-

X1

H Z

JO

B

N O

R

.1

LOCATION MAP

PROJECT LOCATIONS

KEY MAP # 533E & # 533H

FACET # 5355D2 & 5455A11

MAJOR REPAIRS

HCFCD PROJECT I.D. #D100-00-00-X134

2025 BRAYS BAYOU

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

Firm Registration No. F-76

10/31/2025

Issued for Bidding 11/21/2025 Job No.: 25-0370

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

NTS

Q U

A N

TI

TY

E

ST

IM

A

TE

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

Firm Registration No. F-76

10/31/2025

ACTIVITIES ON/OR ACROSS CENTERPOINT ENERGY FEE OR EASEMENT PROPERTY

NO APPROVAL TO USE, CROSS OR OCCUPY CENTERPOINT FEE OR EASEMENT PROPERTY IS GIVEN. IF YOU NEED TO USE CENTERPOINT PROPERTY, PLEASE CONTACT OUR SURVEYING & RIGHT OF WAY DIVISION AT (713) 207-6348 OR (713) 207-5769.

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

G

EN

ER

A

L N

O

TE

S

O F

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

G

EN

ER

A

L N

O

TE

S

O F

NTS

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

SCALE: 1" = 1,000'

0 250 500 1000

LE

O

PO

LD

D R

SCALE: 1"=1000'

PLAN SHEET GENERAL NOTES:

1. RIGHT & LEFT SIDES ARE BASED ON STANDING IN THE

CENTER OF THE CHANNEL, FACING UPSTREAM.

2. U/S = UPSTREAM, D/S = DOWNSTREAM

MACGREGOR SITE

SEE SHEET 15

SEE SHEET 14 FOR BENCHMARK NOTE

SEE SHEET 6 FOR ACCESS

GENERAL NOTES:

1. R.O.W. LINES SHOWN ON PLANS ARE APPROXIMATE. DO NOT CROSS FENCE LINES.

2. CONTRACTOR TO PROVIDE HCFCD WITH A COPY OF THE CONTRACTOR'S AGREEMENT WITH THE PRIVATE

PROPERTY OWNER, IN CONFORMANCE WITH HCFCD GENERAL CONDITIONS

LEOPOLD SITE

SEE SHEET 9

SEE SHEET 8 FOR BENCHMARK NOTE

SEE SHEET 6 FOR CONSTRUCTION ACCESS

HE

RM

AN

N

PA

RK

D R

HERMANN PARK

RIN

GNESS A

VE

HOLCOMBE

BR

AY

S

BA

YO

U

G R

EE

N

W

AY

T R

AI

L

S.

M

AC

GR

EG

OR

AL

M

ED

A

R D

HERMANN PARK CT

CAMDEN DR

S. MACGREGOR

G R

AN

D

B

LV

D

DIXIE STREET

AR

DM

ORE

S

T

S.H. 288BILL COATS BRIDGE

SA

M

PS

ON

ST

N MACGREGOR WAY

BU

RKE

TT

S

T

S MACGREGOR

SC

O

TT

S

T

S MACGREGOR

N MACGREGOR WAY

SOUTHMORE BLVD

CONSTRUCTION ACCESS ROUTE:

C

AM

BR

ID

G E

PL

AN

IN

D

EX

1"=1,000'

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

McWILLIAMS

DOG PARK

BR

AY

S

BA

YO

U

G R

EE

N

W

AY

T R

AI

L

URBAN

FOREST

BILL COATS BRIDGE

HERMANN

PARK

MAINTENANCE

OFFICE

DIXIE STREET

AL

M

ED

A

R D

BAYOU

PARKLAND

HOLCOMBE

HERMANN PARK CT

S.

M

AC

GR

EG

OR

SOUTHMORE BLVD

LE

O

PO

LD

D R

SOUTH MACGREGOR WAY

RIO VISTA ST

S MACGREGOR

SC

O

TT

S

T

N MACGREGOR WAY

TI

ER

W

ES

TE

R

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

SCALE: 1" = 400'

0 100 200 400

MACGREGOR SITE NOTES:

CONCRETE TRAILS SHOWN IN AERIAL BACKGROUND SHALL REMAIN

OPEN TO THE PUBLIC DURING CONSTRUCTION; PROVIDE

CONSTRUCTION FENCE ON LEFT SIDE BETWEEN CHANNEL LINING

AND TRAIL; KEEP CONSTRUCTION EQUIPMENT OFF TRAILS UNLESS

AUTHORIZED BY THE ENGINEER; REPAIR ANY TRAIL DAMAGE DUE

TO CONSTRUCTION, AT NO COST TO THE DISTRICT.

HCFCD WILL FACILITATE AN AGREEMENT BETWEEN THE

CONTRACTOR AND HPARD FOR CONSTRUCTION ACCESS VIA THEIR

MAINTENANCE OFFICE DRIVEWAY AND THROUGH THE PARK TO

HCFCD BRAYS BAYOU RIGHT OF WAY. A TEMPORARY STORMWATER

CULVERT IS REQUIRED TO CROSS THE EXISTING DRAINAGE SWALE

ALONG THE SOUTH SIDE OF THE HPARD DRIVEWAY.

PROVIDE HCFCD WITH A COPY CONTRACTOR'S AGREEMENT WITH

HPARD IN CONFORMANCE WITH HCFCD GENERAL CONDITIONS

PROVIDE, INSTALL & MAINTAIN 6' CHAIN LINK FENCE ON BOTH SIDES

OF THE CONSTRUCTION ACCESS ROUTE THROUGH "BAYOU

PARKLAND". MEET ON SITE WITH HCFCD FOR CONFIRMATION OF

ACCESS ROUTE PRIOR TO BEGINNING ANY OTHER WORK ON-SITE.

REMOVE FENCE AND RESTORE ACCESS ROUTE TO

PRE-CONSTRUCTION CONDITION FOR ACCEPTANCE.

1"=400'

FLOW

FL

O W

FL

OW

FLOW

FLOW

FLOW

PLAN SHEET GENERAL NOTES:

1. RIGHT & LEFT SIDES ARE BASED ON STANDING IN THE

CENTER OF THE CHANNEL, FACING UPSTREAM.

2. U/S = UPSTREAM, D/S = DOWNSTREAM

3. CONTRACTOR TO RECORD AND SUBMIT

PRE-CONSTRUCTION PHOTOS AND VIDEO FOR EACH

SITE IMMEDIATELY PRIOR TO STARTING WORK AT A

SITE IN CONFORMANCE WITH GENERAL CONDITIONS

PARAGRAPH 5.25

ACCESS FROM ALMEDA RD VIA HOUSTON PARKS

AND REC. MAINTENANCE OFFICE DRIVEWAY

CONCRETE CHANNEL REPAIR

ADJACENT TO BAYOU PARKLAND

ON ALMEDA ROAD

SLOPE REPAIR AT

LEOPOLD DRIVE

ACCESS FROM

LEOPOLD DRIVE

C O

N

ST

R U

C

TI

O N

A C

C

ES

S M

A P

(TEMP. STORMWATER CULVERT IS

REQUIRED FOR ACCESS ACROSS

EXIST. SWALE)

LEOPOLD SITE NOTES:

ALIGNMENT OF EXISTING TRAIL IS BEING ADJUSTED. PROPOSED

WORK WILL REQUIRE A TRAIL CLOSURE DURING TRAIL DEMO AND

RE-CONSTRUCTION.

PROVIDE, INSTALL & MAINTAIN 6' CHAIN LINK FENCE ON THE BAYOU

SIDE OF THE EXISTING TRAIL UNTIL TRAIL CLOSURE IS SET UP FOR

PROPOSED GRADING AND TRAIL REPLACEMENT WORK.

REMOVE FENCE DURING SITE RESTORATION FOR ACCEPTANCE.

CONTRACTOR TO TAKE AND SUBMIT PRE-CONSTRUCTION PHOTOS

AND VIDEO FOR EACH SITE IMMEDIATELY PRIOR TO STARTING

WORK AT A SITE IN CONFORMANCE WITH GENERAL CONDITIONS

PARAGRAPH 5.25

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

NTS

LE

O

PO

LD

B O

R

IN

G L

O G

S

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

385+00385+00

Lot. 2

Lot. 9

Lot. 10

Lot. 3

EXISTING BB Inlet Top = 35.2724" RCPFL=28.82TBM "A"Elev = 35.28

24" RCPFL=10.87

Called 0.4378 AC

Harris County Flood Control District

H.C.D.R. No. 65269A

Called 32.15 ACJudgement

Harris County Flood Control District

vs. City of HoustonNo. 97648 H.C.D.R. No. 103349B

Called 0.1688 AC

Harris County Flood Control District

H.C.D.R. No. 65267A

Called 0.1688 AC

Harris County Flood Control District

H.C.D.R No. 65267A

LEOPOLD PLACE

H.C.D.R. No. 161822

Called 0.2176 AC

Harris County Flood Control District

O.P.R.R.P.H.C.T. No. RP-2016-284272

Called 0.4993 ACJudgementH.C.F.C.Dvs. Roland BeachNo. 88031 H.C.D.R. No. D731775

Called 0.98864 AC

Harris County

Flood Contro l D istr ict

O.P.R.R.P.H.C.T. N

o. H

848350

Called 0.5017 ACJudgementH.C.F.C.Dvs. Jack NeveleffNo. 87085 H.C.D.R. No. 84301ALot 1

TOP OF WASH OUT

WASH OUT AREA

TOP OF CONCRETE SLOPE

TOP OF CONCRETE SLOPE

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

SCALE: 1" = 40'

0 10 20 40

NOTES:

1. THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE

COMMITMENT.

2. BEARINGS BASIS PER TEXAS STATE PLANE COORDINATE SYSTEM,

SOUTHCENTRAL ZONE. ALL COORDINATES AND DISTANCES ARE IN

GRID AND WITH A COMBINED SCALE FACTOR OF OF 0.99988750455409.

3. SQUARE FOOTAGE TOTALS SHOWN HEREON OR REFERENCED

HEREIN ARE BASED ON MATHEMATICAL CLOSURES AND DO NOT

NECESSARILY REPRESENT THE POSITIONAL ACCURACY OF THE

BOUNDARY MONUMENTS.

4. THIS SURVEY DOES NOT PROVIDE A DETERMINATION OR OPINION

CONCERNING THE LOCATION OR EXISTENCE OF WETLANDS, FAULT

LINES, TOXIC OR HAZARDOUS WASTE AREAS, SUBSIDENCE,

OVERHEAD, SUBSURFACE AND ENVIRONMENTAL CONDITIONS OR

GEOLOGICAL ISSUES. NO STATEMENT IS MADE CONCERNING THE

SUITABILITY OF THE SUBJECT TRACT FOR ANY INTENDED USE,

PURPOSE OR DEVELOPMENT.

5. THE WORD "CERTIFY" OR "CERTIFICATE" AS SHOWN AND USED

HEREON MEANS AN EXPRESSION OF PROFESSIONAL OPINION

REGARDING THE FACTS OF THE SURVEY AND DOES NOT CONSTITUTE

A WARRANTY OR GUARANTEE, EXPRESSED OR IMPLIED.

BENCHMARKS:

ELEVATIONS WERE BASED ON REFERENCE MARKERS 040075R2, 040070,

040065R.

(NAVD88, GEOID 12B ADJUSTMENT)

TBM "A": BOX CUT IN CURB ON BB INLET. AT END OF LEOPOLD STREET

AS SHOWN HEREIN

ELEVATION: 35.28

NTS

SOIL BORING

GB-1

SOIL BORING

GB-1H

HCFCD R.O.W.

HCFCD R.O.W.

TBM "A"

LE

O

PO

LD

D

RI

VE

HCFCD R.O.W.

THIS SHEET IS BASED ON

SURVEY PROVIDED TO

HUITT-ZOLLARS BY HCFCD.

SEALED HCFCD SURVEY

DRAWING IS AVAILABLE ON

REQUEST.

LE

O

PO

LD

S U

R

VE

Y

FLOW

D100-00-00

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

TOP OF WASH OUT

WASH OUT AREA

112.75'

EXIST. 24" RCP

S12° 38' 43.02"W 200.00

1+

2+

0+

1+

35.63

36.94 TOC

36.78 PROP.

36.07

13.43' 23.94'

'R

.5

'R

'R

1.

MATCH EXIST. END OF CONC.

SAWCUT EXIST. ASPHALT TRAIL;

MATCH SURFACE ELEV.

DO

W

NS

TR

EA

M L

IM

IT

MAT

CH

E

XI

ST

. S

LO

PE

UP

ST

RE

AM

L

IM

IT

M

AT

CH

E

XI

ST

. S

LO

PE

36.90 TOC

36.82 PROP.

30.9'

'R

.60

66.04'

198.87'

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

SCALE: 1" = 20'

0 5 10 20

NTS

A

PROPOSED EARTHEN REPAIR PLAN

LEOPOLD DRIVE

SCALE: 1"=20'

A

HCFCD R.O.W.HCFCD R.O.W.

TBM "A"

LE

O

PO

LD

D

RI

VE

HCFCD R.O.W.

EXISTING CONC. TRAIL

REMOVE EXIST. ASPHALT TRAIL

PROP. 6" CONC. TRAIL

ON 6" CEMENT

STAB. SUBGRADE

5-FT OFFSET FROM PROP.

CONC. TO BE 0.83' BELOW

TOP OF CONCRETE;

TRANSITION TO EXIST.

GRADES AT ENDS

EXISTING TREE

TO BE REMOVED

NOTE:

EXISTING

ASPHALT TRAIL

END ALIGNMENT

X=3,124,428.3253

Y=13,823,701.8748

LE

O

PO

LD

S

IT

E

PL

A N

EXISTING 24" STORM DRAIN

BORE BH-1

GH-1H

RIPRAP GR. NO. 2

TOP ELEV. 17.6

TOC = TOP OF

CONCRETE

PROP. = PROPOSED

FINISH GRADE

A

SEE B ON SHEET 11 FOR PROP.

TRAIL TO EXIST. TRAIL DETAIL

SEE DETAILS C & E, SHEET 11

PROVIDE, INSTALL & MAINTAIN 6' CHAIN LINK FENCE ON THE BAYOU

SIDE OF THE EXISTING TRAIL UNTIL TRAIL CLOSURE IS SET UP FOR

PROPOSED GRADING AND TRAIL REPLACEMENT WORK.

REMOVE FENCE DURING SITE RESTORATION FOR ACCEPTANCE.

2. COMPACT APPROVED MATERIAL IN CONFORMANCE

WITH HCFCD STD SPECS 02314 AND 02315

1. REMOVE EXISTING SOIL TO FIELD VERIFY

BOTTOM OF FAILURE PLANE.

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

0+75 1+00 1+25 1+50 1+75 1+80

3.54:1 PROP. SLOPE AT SECTION LINE

40'

2'

3'

10' 5' 5'

2'

4'

EXIST. HIGH PT=36.82

PROP. EDGE OF CONC.=36.94

PROP. EDGE OF CONC.=36.90

SLOPE

CONC.

0.5%

5'

SHOULDER

6:1 MAX.

4'

23'

PROP. 6"

CONC. TRAIL

5'

SLOPE TO

EXIST. GRADE

TRANSITION TO

EXIST. GRADE

PROP. GRADE=36.82

PROP. GRADE=36.78

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

SCALE: 1" = 10'

0 2.5 5 10

NTS

PROPOSED EARTHEN REPAIR SECTION

LEOPOLD DRIVE

SCALE: 1"=10'9

A

EXISTING GROUND

EXISTING ASPHALT TRAIL

TO BE REMOVED

TOP OF EXIST.

CONCRETE SLOPE LINING

PROP. BENCHING

PROP. GRADE

PROP. RIPRAP

GRAD. NO. 2

TOP ELEV=17.6

LE

O

PO

LD

C R

O

SS

S

EC

TI

O

N

MATCH EXIST.

GRADE

TOP OF PROP. 3.54:1 SLOPE

= ELEV. 36.07

BURIED RIPRAP

PER 02378 3.3 F.

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

GENERAL NOTES

EXISTING PAVEMENT PROPOSED PAVEMENT

1/4" MIN.

1/2" MAX.

MIN 1' - 9"

AS DIRECTED BY ENGINEER

3/

4"

12"

6"

3"

TRANSVERSE CONSTRUCTION

JOINT

#4 TIE BAR 2'-9"

@ 18" C-C SPACING

GROUT WITH 'PO-ROC'

EPOXY GROUT OR

APPROVED EQUAL

1. FOR FURTHER INFORMATION REGARDING PLACING CONCRETE AND REINFORCEMENT,

SEE COH SPECIFICATIONS 02338 - PORTLAND CEMENT STABILIZED SUBGRADE AND

02775 - CONCRETE SIDEWALK.

2. DO NOT SHEAR CUT DOWEL BARS.

3. REPLACE ANY BENT LONGITUDINAL REINFORCING. IF THERE IS NOT SUFFICIENT EXPOSED

REINFORCING TO PROVIDE A MINIMUM OF A 33 TIMES BAR DIAMETER LAP, REMOVE THE

EXISTING PAVEMENT AND SUFFICIENTLY EXPOSE THE EXISTING REINFORCING TO PROVIDE

A 33 TIMES BAR DIAMETER LAP. REPLACE ANY SHEAR BARS THAT ARE DISTURBED, BY

DRILLING AND GROUTING AS REQUIRED BY NOTE 5 BELOW; PERFORM THIS CORRECTIVE

ACTION AT NO EXPENSE TO HCFCD.

4. TIE BARS AND DOWEL BARS OMITTED, LOST, OR DAMAGED SHALL BE REPAIRED BY

DRILLING AND EPOXY GROUTING AT NO EXPENSE TO HCFCD.

5. ACP STANDS FOR ASPHALT CONCRETE PAVEMENT.

6. PROVIDE COH SPEC 02338 PORTLAND CEMENT STABILIZED SUBGRADE WHICH SHALL NOT BE

MEASURED OR PAID SEPARATELY BUT SHALL BE INCIDENTAL TO THE UNIT PRICE BID AND

MEASURED FOR 02775 CONCRETE SIDEWALK.

2"

2" STEEL

COMPACTED ACP

BACKFILL

CONC

TRAIL

3' - 0" 6"

3"

PROPOSED TERMINUS OF CONCRETE TRAIL

NOTE:

ADDITIONAL CONCRETE FOR THICKENED EDGE IS INCIDENTAL.

BACKFILL DISTURBED MATERIAL IN THE FLEXIBLE PAVEMENT

WITH ACP. THIS ACP IS INCIDENTAL.

TRAIL

SUBGRADE

SET FINISH GRADE

1.5" BELOW TOP OF

CONCRETE TRAIL ON

DOWNHILL SLOPES

(ALL)

1.5"

2.0% TYP

6:1

MAX

6:1

MAX

SH

O

U

LD

ER

SH

O

U

LD

ER

PROP 6" REINFORCED

CONCRETE TRAIL

EXIST GROUND

FINISHED GRADE

6" CEMENT STABILIZED

SUBGRADE

2'2'

CL

MATCH EXIST.

DETAIL A

2.0% MAX

3"

3"

6" REINFORCED CONC TRAIL

TRANSVERSE STEEL

#4 BAR CONTINUOUS

12" C-C (TYP)

LONGITUDINAL STEEL

#4 BAR CONTINUOUS

12" C-C (TYP)

MATCH EXISTING TRAIL WIDTH

6" CEMENT STABILIZED SUBGRADE

SEE NOTE 6

12"

SET FINISHED

GRADE 1-1/2"

BELOW TOP OF

CONCRETE TRAIL

6:1

MAX

6:1

MAX

SH

O

U

LD

ER

SH

O

U

LD

ER

2'2'

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

NTS

EXISTING ASPHALT TRAIL PROPOSED CONCRETE TRAIL

SA

W

C U

T

EX

IS

TI

N G

A

SP

H A

LT

T

R A

IL

TR

A

IL

D

ET

A

IL

S

PROP. TRAIL CONNECTION TO EXIST. ASPHALT PAVEMENT

SCALE: N.T.S.11

A

PROP. TRAIL CONNECTION TO EXIST. TRAIL PAVEMENT

SCALE: N.T.S.11

B

TYPICAL SECTION 1

PROPOSED CONCRETE TRAIL

SCALE: N.T.S.11

C

TYPICAL DETAIL

CONCRETE TRAIL - TYPICAL DETAILS

SCALE: N.T.S.11

E

DETAIL A

SCALE: N.T.S.11

D

FLEXIBLE

PAVEMENT

STRUCTURE

THIS SHEET

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

℄ CHANNEL

VARIES

1'-0"

VARIES

1'-0"

TYPICAL EXISTING SLOPE LINING TYPICAL EXISTING SLOPE LINING10'-10" 10'-10"TYPICAL EXISTING LOW-FLOW LINING

4'-0" 3'-2" 3'-2" 4'-0" 1'-0" 1'-0" 1'-0" 1'-0"

6" CONC. LINING

6" CONC. LINING

2'-0"

6" CONC.

LINING

20'-0" 20'-0" TYPICAL BOTTOM WIDTHS

1V:30H 1V:30H

TYPICAL EXISTING SUB-DRAINAGE

PIPE SYSTEM

TYPICAL EXISTING SUB-DRAINAGE PIPE SYSTEM,

CLEAN OUT BOX & LATERAL PIPE

TYPICAL

LONGITUDINAL

TURN DOWN

(GRADE BEAM)

12" 12" 12" 6"

12" 6"

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

TYPICAL EXISTING SECTION

MACGREGOR SITE LOOKING UPSTREAM

SCALE: NOT TO SCALE

A

AS SHOWN

M A

C G

R

EG

O R

TY

PI

C A

L

EX

IS

TI

N G

C R

O

SS

S

EC

TI

O

N

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

NTS

M A

C G

R

EG

O R

S

IT

E C

O N

ST

R

U C

TI

O

N N

O

TE

S

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

495+00

500+00

495+00

500+00

41.53

41.34

41.17

41.07

41.05 40.94

40.97

41.10

41.26 41.41

21.49 21.55

21.57

21.54

21.39

21.32

21.18

20.77

20.73 20.90

20.71

21.38

21.38

21.35 21.34 21.27

21.7321.67

21.62

21.21

21.46

21.43

21.22 21.19 21.28

21.07 20.83

20.79 21.04 20.97

20.65 20.83

21.6

21.6

21.6

21.6

21.4 21.3

21.2

20.8

20.8

20.8 20.7

8.5

8.5 8.5

8.2

8.1

7.9

7.9

7.7

7.5 7.5

8.6

8.5 8.6

8.5

8.4

8.5

8.4

8.4

8.4

8.1 8.2

7.9 7.8

7.7

7.6 7.4

21.3 21.4

21.3 21.4

21.5

21.2 21.2 20.9

20.7 21.0

20.9

20.6 20.8

22.2

21.7

21.2

21.7

21.6

21.2

8.0 8.1

8.0

7.8

7.7

7.4

7.3

7.4

7.1 7.0

8.1

8.1

8.1

7.8

7.7

7.6

7.4 7.2

7.2 7.0

22.2

21.7

21.3 21.7 21.6

21.1

41.4

41.2 41.2

40.8

40.9

40.7

40.3 40.4

40.4 40.5

40.6

40.4

40.3 40.4

39.5 39.7

39.8

38.9

38.9

38.8

23.4

24.5

25.1 23.5

23.0

22.9

22.6

22.1

21.8

22.5

21.8

22.2

22.6

23.2

25.0

21.9

21.3

21.2

23.9 22.8

22.6 22.3

21.8

22.2

22.1

22.5

22.8

23.9

24.5

22.3

22.1

22.0

22.1

21.5

21.3

20.7

23.3

23.1

23.8

23.323.0

23.0

22.3

22.2

22.0

22.0

22.6

23.0

21.6

21.8 21.9

21.7

21.7 21.7

21.6 21.4

21.6

21.6

21.522.6

24.2

26.4

30.4

31.7

35.2

34.3

30.8

24.1

22.5

21.6

26.6 27.4

33.7

21.6 22.8

28.0

31.9

21.1

26.1

31.0

36.3

21.0

26.3

32.3 36.8

21.2

27.9

33.2

21.0 22.9

28.5

35.6

20.523.1

28.4

34.6 35.0

29.0

23.4

20.8 20.1

20.0

20.5

40.1

39.9 40.1

39.7

41.5

41.2

41.1

39.7

40.8

39.6 39.3

39.8

39.1

40.4

39.1

39.6

39.3

39.8

38.9

39.3

40.4

39.7

40.1

40.3 39.9

40.2

39.8

39.8

22.73

22.73 22.71

22.44 22.29

22.18

21.80 21.70

22.81

22.84

22.90

22.91 22.78 22.76

22.78 22.68 22.02

21.74

21.45 21.37

41.08 41.05 41.00

41.02 41.01 41.04

41.04

41.03 41.00 40.84 40.73

40.78

40.76

40.56

40.45 40.45

40.48

40.50 40.69 40.43 40.46

40.12

40.18 40.25 40.02

39.94

40.03

40.22

40.46

40.2340.31

40.31 40.4340.6340.5240.45

40.43

40.47

40.53 40.58

40.55

40.54

40.5740.60

40.72

40.90

40.86

40.85

40.84

41.01

22.56

22.54 22.53

22.28

22.15 22.02

21.60

21.59 22.69 22.68 21.86 21.60

21.30 21.21

6.74

6.27

8.11

7.97

6.70

5.98

6.05

5.86

5.68

5.60 5.64

6.94

6.62

6.72

6.39

6.25

6.16

5.83

5.54 5.61

14.414.2

13.3 13.5

6.5 8.0

8.4 8.229.19

7.89

494+00

496+00

497+00

498+00

499+00

501+00

502+00

CITY OF HOUSTON

VOL. 327, PG. 146H.C.D.R.

CITY OF HOUSTON

VOL. 327, PG. 146H.C.D.R.

HARRIS COUNTY FLOOD CONTROL

DISTRICT RIGHT-OF-WAY EASEMENT

VOL. 3537, PG. 333H.C.D.R.

STATION=498+05.98

OFFSET=0.00

NORTHING=13822921.59

EASTING=3115687.80

L=826.700

Δ=99.2167 R=477.404

S8° 04' 27.00"W

646.62'

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

SCALE: 1" = 60'

0 30 60 120

NOTES:

1. THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE

COMMITMENT. EASEMENTS AND RESTRICTIONS MAY EXIST ARE NOT

REFERENCED HEREON; NO ADDITIONAL RESEARCH REGARDING THE

EXISTENCE OF EASEMENTS OR RESTRICTIONS OF RECORD HAS

BEEN PERFORMED HARRIS COUNTY FLOOD CONTROL DISTRICT.

2. BEARINGS BASIS PER TEXAS STATE PLANE COORDINATE SYSTEM,

SOUTHCENTRAL ZONE. ALL COORDINATES AND DISTANCES ARE IN

GRID AND WITH A COMBINED SCALE FACTOR OF 0.99988750895636.

3. SQUARE FOOTAGE TOTALS SHOWN HEREON OR REFERENCED

HEREIN ARE BASED ON MATHEMATICAL CLOSURES AND DO NOT

NECESSARILY REPRESENT THE POSITIONAL ACCURACY OF THE

BOUNDARY MONUMENTS.

4. THIS SURVEY DOES NOT PROVIDE A DETERMINATION OR OPINION

CONCERNING THE LOCATION OR EXISTENCE OF WETLANDS, FAULT

LINES, TOXIC OR HAZARDOUS WASTE AREAS, SUBSIDENCE,

OVERHEAD, SUBSURFACE AND ENVIRONMENTAL CONDITIONS OR

GEOLOGICAL ISSUES. NO STATEMENT IS MADE CONCERNING THE

SUITABILITY OF THE SUBJECT TRACT FOR ANY INTENDED USE,

PURPOSE OR DEVELOPMENT.

5. THE WORD "CERTIFY" OR "CERTIFICATE" AS SHOWN AND USED

HEREON MEANS AN EXPRESSION OF PROFESSIONAL OPINION

REGARDING THE FACTS OF THE SURVEY AND DOES NOT

CONSTITUTE A WARRANTY OR GUARANTEE, EXPRESSED OR IMPLIED.

BENCHMARKS:

ELEVATIONS WERE BASED ON REFERENCE MARKERS 040090R,

040095, AND 040101R.

(NAVD88, GEOID 12B ADJUSTMENT)

TBM "A": BOX CUT ON SOUTHEAST CORNER OF CONCRETE PAD

WITH WATER FOUNTAIN, LOCATED ON THE EAST SIDE OF BRAYS

BAYOU (WITHIN PROJECT LIMITS).

ELEVATION: 44.38'

TBM "B": BOX CUT ON SIDEWALK ON WEST SIDE OF BRAYS BAYOU,

LOCATED APPROXIMATELY 310 FEET (MORE OR LESS) SOUTH OF

BILL COATS PEDESTRIAN BRIDGE AT SIDEWALK JUNCTION

ELEVATION: 22.75'

NTS

TBM "A"

TBM "B"

HCFCD R.O.W.

HCFCD R.O.W.

FLOW

FLOW

FLOW

M A

C G

R

EG

O R

S U

R

VE

Y

THIS SHEET IS BASED ON

SURVEY PROVIDED TO

HUITT-ZOLLARS BY HCFCD.

SEALED HCFCD SURVEY

DRAWING IS AVAILABLE ON

REQUEST.

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

495+00

500+00

495+00

500+00

41.53

41.34

41.17

41.07 41.05

40.94

40.97

41.10

41.26 41.41

21.49 21.55

21.57

21.54

21.39 21.32

21.18

20.77

20.73

20.90 20.71

21.38

21.38

21.35 21.34 21.27

21.7321.67

21.62

21.21

21.46

21.43

21.22 21.19 21.28

21.07

20.83

20.79 21.04 20.97

20.65 20.83

21.6

21.6

21.6

21.6

21.4 21.3

21.2

20.8

20.8

20.8 20.7

8.5

8.5 8.5

8.2

8.1

7.9

7.9

7.7

7.5 7.5

8.6

8.5 8.6

8.5

8.4

8.5

8.4

8.4

8.4

8.1 8.2

7.9 7.8

7.7

7.6 7.4

21.3 21.4

21.3 21.4

21.5

21.2 21.2 20.9

20.7 21.0

20.9

20.6 20.8

22.2

21.7

21.2

21.7

21.6

21.2

8.0

8.1

8.0

7.8

7.7

7.4

7.3

7.4

7.1

7.0

8.1

8.1 8.1

7.8

7.7

7.6

7.4

7.2

7.2 7.0

22.2

21.7

21.3 21.7

21.6

21.1

41.4

41.2 41.2

40.8

40.9

40.7

40.3 40.4

40.4 40.5 40.6

40.4

40.3 40.4

39.5 39.7

39.8

38.9

38.9

38.8

23.4

24.5

25.1 23.5

23.0

22.9

22.6

22.1

21.8

22.5

21.8

22.2

22.6

23.2

25.0

21.9

21.3

21.2

23.9 22.8

22.6

22.3

21.8

22.2

22.1

22.5

22.8

23.9

24.5

22.3

22.1

22.0

22.1

21.5

21.3

20.7

23.3

23.1

23.8

23.323.0

23.0

22.3

22.2

22.0

22.0

22.6

23.0 21.6

21.8 21.9

21.7

21.7 21.7

21.6 21.4

21.6

21.6

21.522.6

24.2

26.4

30.4

31.7

35.2

34.3

30.8

24.1

22.5

21.6

26.6 27.4

33.7

21.6

22.8

28.0

31.9

21.1

26.1

31.0

36.3

21.0

26.3

32.3 36.8

21.2

27.9

33.2

21.0 22.9

28.5

35.6

20.523.1

28.4

34.6

35.0

29.0

23.4

20.8 20.1

20.0

20.5

40.1

39.9 40.1

39.7

41.5

41.2

41.1

39.7

40.8

39.6 39.3

39.8

39.1

40.4

39.1

39.6

39.3

39.8

38.9 39.3

40.4

39.7

40.1

40.3

39.9

39.8

22.73

22.73 22.71

22.44 22.29

22.18

21.80 21.70

22.81

22.84

22.90

22.91 22.78 22.76

22.78 22.68 22.02

21.74

21.45 21.37

41.08 41.05 41.00

41.02 41.01 41.04

41.04

41.03 41.00 40.84 40.73

40.78

40.76

40.56

40.45 40.45

40.48

40.50 40.69 40.43

40.46

40.12 40.18

40.25 40.02

39.94

40.03

40.22

40.46

40.2340.31

40.31 40.4340.6340.5240.45

40.43

40.47

40.53 40.58

40.55

40.54

40.5740.60

40.72

40.90

40.86 40.85

40.84

41.01

22.56

22.54 22.53

22.28

22.15 22.02

21.60

21.59 22.69 22.68 21.86 21.60

21.30 21.21

6.74

6.27

8.11

7.97

6.70

5.98

6.05

5.86

5.68

5.60 5.64

6.94

6.62

6.72

6.39

6.25

6.16

5.83

5.54 5.61

14.414.2

13.3 13.5

6.5

8.0

8.4 8.229.19

7.89

494+00

496+00

497+00

498+00

499+00

501+00

502+00

CITY OF HOUSTON

VOL. 327, PG. 146H.C.D.R.

CITY OF HOUSTON

VOL. 327, PG. 146H.C.D.R.

HARRIS COUNTY FLOOD CONTROL

DISTRICT RIGHT-OF-WAY EASEMENT

VOL. 3537, PG. 333H.C.D.R.

STATION=498+05.98

OFFSET=0.00

NORTHING=13822921.59

EASTING=3115687.80

L=826.700

Δ=99.2167 R=477.404

S8° 04' 27.00"W

646.62'

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

SCALE: 1" = 60'

0 30 60 120

NTS

A

(TYP. AT NEW

SLOPE LINING)

REMOVE & DISPOSE OF EXIST

LEFT SLOPE & SHELF LINING,

& LOW FLOW LINING.

INSTALL NEW LINING (TYP)1

A

A

STA. 498+05.98

(TYP)2

REMOVE & DISPOSE OF EXCESS EARTHEN

MATERIAL SUITABLE FOR RE-USE, OR DRYING AND

LANDFILL DISPOSAL, TO BE DETERMINED BY THE

ENGINEER

R. O. W.

REMOVE & DISPOSE OF EXIST RIGHT SLOPE &

SHELF LINING. INSTALL NEW LINING.

B

B

(TYP)2

STA. 495+67.01

STA. 499+87

KEYED CONSTRUCTION

JOINT

STA 495+67

NORTHING=13823158.20

EASTING=3115721.36

BEGIN REMOVE & REPLACE

CONCRETE LINING;

MATCH EXISTING

ELEVATIONS & JOINTS

STA 499+91

NORTHING=13822747.97

EASTING=3115627.43

END REMOVE & REPLACE

CONCRETE LINING

MATCH EXISTING

ELEVATIONS & JOINTS

STEEL SHEET PILE WALL

SEE SHT. 16

PROVIDE TYPE "A" WEEP HOLES (SEE DETAIL SHEET 22) AT 12' MAX

O.C. (TYP. IN NEW SHELF LINING)

SEE CONSTRUCTION NOTE 5 ON SHEET 13 FOR MINIMUM TOP OF

SLOPE ELEVATION

2 PROVIDE WEEP HOLES AT 12' MAX O.C. (TYP.

IN NEW SLOPE LINING)

4 PROPOSED LATERAL STEEL SHEET PILE

WALL (SEE DETAIL SHEET 16)

5 PROPOSED LONGITUDINAL STEEL SHEET PILE WALL

CONSTRUCTION JOINT AT EXISTING CONCRETE LINING

(USE EXPANSION JOINT WHERE DIRECTED BY THE ENGINEER)

KEYED NOTES

FLOW

R. O. W.

R. O. W.

R. O. W.

FLOW

NOTES:

1. SEE SHEET 13 FOR CONSTRUCTION NOTES

2. SEE MACGREGOR SURVEY SHEET 14 FOR BENCHMARK NOTE

3. SEE FOR TYPICAL PROPOSED SECTION THIS SITE

4. SEE FOR TYPICAL EXISTING SECTION THIS SITE

5. PAVED TRAILS (CONCRETE WALKWAY) SHALL REMAIN OPEN TO

THE PUBLIC DURING CONSTRUCTION; PROVIDE 6-FT CHAIN LINK

FENCE DURING CONSTRUCTION ON LEFT SIDE BETWEEN

CHANNEL LINING AND TRAIL; KEEP CONSTRUCTION EQUIPMENT

OFF TRAILS UNLESS AUTHORIZED BY THE ENGINEER; REPAIR

ANY TRAIL DAMAGE DUE TO CONSTRUCTION.

CONSTRUCTION NOTE:

PAYMENT FOR SAW-CUTTING CONCRETE SHALL BE INCIDENTAL

TO PAY ITEM 2120-13, REMOVE & DISPOSE OF CONCRETE

CHANNEL LINING.

A

B

D

A

B

STEEL SHEET PILE WALL

SEE SHT. 16

KEYED CONSTRUCTION

JOINT

A

(TYP. AT NEW

SLOPE LINING)

M A

C G

R

EG

O R

S

IT

E

PL

A N

REGRADE FROM TOP OF CONCRETE SLOPE LINING AT 1V:20H TO

PROVIDE 12'-0" WIDE EARTH BENCH WHERE POSSIBLE. DO NOT

UNDERMINE EXISTING EARTH SLOPE.

REDUCE EARTH BENCH WIDTH WHERE REQUIRED TO AVOID

UNDERMINING EXISTING EARTH SLOPE.

REGRADE AT 1V:3H OR AS DIRECTED BY THE ENGINEER TO

TRANSITION FROM EARTH BENCH TO EXISTING EARTH SLOPE.

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

℄ LOW FLOW

SEE SHEET 15 AND

CONSTRUCTION NOTE 3

ON SHEET 13 FOR LOW FLOW

ELEVATION AND SLOPE NOTES

MATCH EXISTING JOINT

ELEVATION

REMOVE & DISPOSE OF EXISTING LEFT & RIGHT SLOPE,

LEFT & RIGHT SHELF LINING, & LOW FLOW LINING.

INSTALL NEW LINING.

LONGITUDINAL STEEL SHEET PILE

BACK OF

CONCRETE

6 7

1 2

CONTRACTOR TO WORK FROM LEFT SIDE; PROTECT

EXISTING RIGHT SIDE CONCRETE TRAIL; REPAIR ANY

TRAIL DAMAGE DUE TO CONSTRUCTION

STEEL SHEET PILE FLUSH

W/ TOP OF CONC.

-10

-10

0 20 40 60204060

' M

IN

. A

T

IN

SI

DE

ED

GE

F

OR

A

LL

S

HE

ET

S

AL

ON

G

SL

OP

E

LIN

IN

G (T

YP

℄ CHANNEL

SECTION B

TYPICAL SHEET PILE NOTES:

"Z" SECTION STEEL SHEET PILE WALL PZ27

ASTM A 572 GRADE 50 OR APPROVED EQUAL

SHEET PILING TO REMAIN PERMANENTLY IN PLACE

THE TOP OF SHEET PILING SHALL BE AT THE TOP OF

CONCRETE CHANNEL LINING AS SHOWN

THE BOTTOM OF EACH SHEET PILE SHALL BE A MINIMUM OF

12 FEET AND A MAXIMUM OF 13 FEET BELOW THE TOP OF

THAT SHEET PILE

C

CUT, PLUG AND ABANDON EXIST

6" DIA. PVC (TYP.)

C

CUT AND ABANDON EXIST

6" DIA. PVC (TYP.)

B

THICKENED CONCRETE

AROUND LATERAL PILING (TYP.)

B

LATERAL SHEET

PILE WALLTOP OF SHEET PILES FOR

WATER CONTROL

LONGITUDINAL SHEET

PILE WALL

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

SECTION AT PROPOSED LATERAL SHEET PILE WALL

MACGREGOR SITE @ STA. 495+67 & 499+91

LOOKING UPSTREAMSCALE: NOT TO SCALE

B

AS SHOWN

MACGREGOR CROSS SECTION A

MACGREGOR SITE LOOKING UPSTREAM

SCALE: NOT TO SCALE

A

EXISTING CONCRETE LINING

TO BE REMOVED & REPLACED

PROPOSED CONCRETE LINING

EXISTING GROUND

SEE SHEET 8 FOR CONSTRUCTION NOTES

KEYED NOTES

PROPOSED GROUND

EXISTING CONCRETE SIDEWALK

0 10' 20'

GRAPHIC SCALE: 1"= 10'

KEYED NOTES

CONSTRUCTION JOINT AT NEW SLOPE

LINING TO EXISTING SHELF LINING

E

M A

C G

R

EG

O R

C R

O

SS

S

EC

TI

O

N S

A

B

SEE CONSTRUCTION NOTE 5 ON SHEET 13 FOR MINIMUM TOP OF

SLOPE ELEVATION

REGRADE FROM TOP OF CONCRETE SLOPE LINING AT 1V:20H TO

PROVIDE 12'-0" WIDE "EARTH BENCH" WHERE POSSIBLE. DO NOT

UNDERMINE EXISTING "EARTH SLOPE".

REDUCE "EARTH BENCH" WIDTH WHERE REQUIRED TO AVOID

UNDERMINING EXISTING "EARTH SLOPE".

REGRADE AT 1V:3H OR AS DIRECTED BY THE ENGINEER TO

TRANSITION FROM "EARTH BENCH" TO EXISTING "EARTH SLOPE".

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

℄ CHANNEL

VARIES

1'-0"

10'-10" 10'-10" VARIES

1'-0"

TYPICAL EXISTING SLOPE LINING TYPICAL PROPOSED SLOPE LININGTYPICAL PROP. SHELF LINING TYPICAL PROP. SHELF LININGTYPICAL PROPOSED LOW-FLOW LINING

4'-0" 3'-2" 3'-2" 4'-0" 1'-0" 1'-0" 1'-0" 1'-0"

12'-0"

MIN

"Z" SECTION STEEL SHEET PILE WALL PZ27

ASTM A 572 GRADE 50

EQ EQ

2'-0"

MAX TYP

6" CONC. LINING

6" CONC. LINING

TYPE "A" WEEP HOLES PER SHEET 22 AT 12'-0" HORZ.

SPACING, CENTERED ON NEW SHELF LINING (TYP. AT NEW

SHELF LINING)

2'-0"

6" CONC.

LINING

#5 @ 13" (TYP)

20'-0" 20'-0" TYPICAL PROPOSED BOTTOM WIDTH

1V:30H 1V:30H

STEEL SHEET PILE FLUSH

W/ TOP OF CONC.

EQ EQ

D

AT 12'-0" HORIZ. SPACING

(TYP. IN NEW SLOPE LINING)

D

D

AT 12'-0" HORIZ. SPACING

(TYP. IN NEW SLOPE LINING)

F

A

A

PP

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

TYPICAL PROPOSED SECTION

MACGREGOR SITE LOOKING UPSTREAM

SCALE: NOT TO SCALE17

A

M A

C G

R

EG

O R

P R

O

PO

SE

D

C R

O

SS

S

EC

TI

O

N

AS SHOWN

BRAYS BAYOU FEDERAL REACH 3; 40-FT DESIGN BOTTOM WIDTH

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

AS SHOWN

R

EP

A

IR

D

ET

A

IL

S

O F

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

AS SHOWN

R

EP

A

IR

D

ET

A

IL

S

O F

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

AS SHOWN

R

EP

A

IR

D

ET

A

IL

S

O F

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

LOOKING UPSTREAM

AS SHOWN

R

EP

A

IR

D

ET

A

IL

S

O F

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

AS SHOWN

H C

FC

D

C O

N C

R

ET

E

LI

N

IN

G D

ET

A

IL

8 MIN. IN

SIEVE NO.

SIEVE NO.

1/4 IN

MAX. OPENMIN. OPEN

b.

WEIGHT

MAX. AOS

MIN. AOS

d.

1/8 IN

c.

NO. 8

NO. 4

3/8 IN

3/4 IN

1 IN

PIPE: 4 INCH DIA. SCH. 40 PVC

MATERIALS:

WEEP HOLE NOTES:

DRAIN GRAVEL: SIEVE SIZE FINER

HARDWARE CLOTH:

FILTER FABRIC:

CONCRETE LINING

STAIR DETAIL

GRADE BEAM DETAIL

(SEE NOTE 6)

PIPE OUTFALL DETAILS

(FOR RCP OUTFALLS 42 INCH DIA. AND LESS)

RISER

TREAD

TOE OF SLOPEPLAN

O.C. (EACH LAYER)

WEEP HOLE

LINING. (SEE TYP. CHANNEL

TYPICAL TRAPEZOIDAL CHANNEL LINING

TOP OF CHANNEL LINING

STAIRS TO BE INSTALLED

AT LOCATIONS SHOWN

ON PLANS.

TOEWALL AT UPSTREAM AND

DOWNSTREAM ENDS OF

LINING. (SEE TYP. CHANNEL

LINING DETAIL).

TOEWALL AT TOP OF CHANNEL

GRADE BEAM-SEE DETAIL

BO

TT

O M

W

ID

TH

TYPE "B"

PLAN

REINF. STEEL

SYMMETRICAL

CL

WEEP HOLE DETAILS

SECTION

CONCRETE CHANNEL

BOTTOM

SEAL SLAB

SEE NOTE 5.

8.

7.

4 FT. MIN.

1.

2.

3.

4.

5.

6.

FT

DRAIN GRAVEL

FT

3 FT.

IN

15 # ROOFING FELT

PLAN

FT

DRAIN GRAVEL

4 IN.

1 FT.

FT

.4 IN. DIA. PVC

SECTION

1 FT.

FILTER FABRIC

TYPE "B" WEEP HOLE

SECTION

FILTER FABRIC

IN

FT

DRAIN GRAVEL

1 FT. 2 FT. 1 FT.

C

3 FT.

FT

IN

1 FT. 1 FT.

DRAIN GRAVEL

FILTER FABRIC

TYPE "A" WEEP HOLE

SECTION

CONC. CHANNEL

SEAL SLAB

ABOUT

A

A

15 # ROOFING FELT

15 # ROOFING FELT

TYPE "C" WEEP HOLE

L

1.

a.

SEE NOTE 12

ALL AROUND

1 FT.

2. CUT WEEP HOLE PIPE FLUSH WITH CONCRETE SURFACE.

THICKENED AREA

EXTENT OF

NOTES:

CL

15 FT.

TOP OF CHANNEL LINING

IN.

IN.

2 FEET

LINING DETAIL.)

4 IN. DIA. PVC

12 INCHES #4 BARS

OZ/SY

3. TYPE "A" AND "C" WEEP HOLES FOR TYPICAL RECTANGULAR

CONCRETE CHANNEL LINING. TO BE STAGGERED.

TY

P.

SEE NOTE 9.

15 # ROOFING FELT

6 IN. 6 IN.

100 MIN

70 MAX

6 0Z. MIN

TYPICAL CHANNEL LINING DETAIL

2 FT.

1 AND 2.

SEE NOTES

TYPE "B" WEEP HOLE.

MID-SLOPE LINING

PILOT CHANNEL

(SEE TABLE

ONE BELOW)

OPTIONAL

BOTTOM WIDTH

IN

KEYED JOINT.

1 FT.

1 AND 2.

A

SEE NOTES

HALF SECTION

IN

INCHES SEE TYP.

DETAIL A

SEE DETAIL A.

CHANNEL LINING DETAIL.

TOP OF BANK LINING

M

ATCH LINE "A"

CHANNEL LINING HALF SECTION

TYPICAL RECTANGULAR CONCRETE

M

ATCH LINE "A"

0 - 60

20 - 90 70 - 100

9.

SEE WEEP HOLE DETAILS.

TOEWALL UPSTREAM

& DOWNSTREAM.

TRIM PIPE FLUSH

WITH CHANNEL

LINING AS DIRECTED

BY THE ENGINEER 10.

SEE NOTE 10.

STRUCTURAL CONCRETE FOR CONCRETE CHANNEL LINING AND NONSTRUCTURAL CONCRETE FOR SEAL SLAB SHALL BE IN

ACCORDANCE WITH SPECIFICATION SECTION NO. 03310-CONCRETE.

REINFORCING STEEL SHALL BE IN ACCORDANCE WITH SPECIFICATION SECTION NO. 03310-CONCRETE.

EXCAVATION AND BACKFILL FOR CONCRETE CHANNEL LINING SHALL BE IN ACCORDANCE WITH SPECIFICATION SECTION NO.

02316-STRUCTURAL EXCAVATING AND BACKFILLING.

RIPRAP SHALL BE IN ACCORDANCE WITH SPECIFICATION SECTION NO. 02378-RIPRAP AND GRANULAR FILL.

A NON-REINFORCED 4 INCH MINIMUM NONSTRUCTURAL CONCRETE SEAL SLAB IS REQUIRED BENEATH THE BOTTOM OF

CONCRETE CHANNELS.

STRUCTURAL CONCRETE GRADE BEAMS SHALL BE INSTALLED TRANSVERSELY AT 20 FOOT MAX. CENTERS ON CONCRETE

LINED CHANNELS WITH BOTTOM WIDTHS EQUAL TO OR GREATER THAN 20 FEET.

JOINTS:

A. PLACE CONSTRUCTION JOINT IN CONCRETE LOW-FLOW, TRAPEZOIDAL BOTTOM SECTIONS AND SLOPES AT 20 FOOT

MIN., SPACING CONTINUOUSLY THROUGH CHANNEL LINING.

B. PLACE EXPANSION JOINT IN CONCRETE LOW-FLOW, TRAPEZOIDAL BOTTOM SECTIONS, AND SLOPES AT 60 FOOT MAX.

SPACING CONTINUOUSLY THROUGH CHANNEL LINING.

CEMENT STABILIZED SAND SHALL BE PROVIDED AND PLACED IN ACCORDANCE WITH SPECIFICATION SECTION NO. 02321

-CEMENT STABILIZED SAND.

DELETE 2 FT FLAT EDGE WHEN LINING IS BELOW TOP OF BANK. SEE MID-SLOPE LINING DETAIL.

UPSTREAM AND DOWNSTREAM TOE WALL 3 FOOT MIN. DEPTH AT BOTTOM OF SLOPE AND 8 INCHES THICK.

MINIMUM #4 BARS (GRADE 60) AT 12 INCHES ON CENTER EACH WAY.

VARIES BASED ON SIDE SLOPE. MINIMUM 1 FOOT VERTICAL AT TOE OF SLOPE.

FOR RCP OUTFALLS 48 INCHES DIA. AND LARGER, USE HEADWALL/WINGWALL DETAIL AS CALLED FOR ON PLANS.

(TYP.)

C CHANNELL

FT

1 FT.

15 # ROOFING FELT

CLOTH

HARDWARE

CLOTH

HARDWARE

HARDWARE CLOTH W/HARDWARE CLOTH

4 IN. PVC PIPE

OVER END.

NON-WOVEN GEOTEXTILE

11.

FT

TYPE B WEEP HOLE.

TYPE A WEEP HOLE.

SEE WEEP HOLE DETAILS.

SEE WEEP HOLE DETAILS.

4 IN. DIA. PVC PIPE

IN

IN

IN

IN

CL

SECTION

IN

IN

IN

IN

IN

4 IN. DIA.

IN

ELEVATION

APPLY CONST. ADHESIVE

TO FILTER FABRIC TOP &

BOTTOM CONTINUOUSLY

PVC PIPE

12 IN.6

IN

C

SEE NOTE 5.

SEAL SLAB

CHANNEL

BOTTOM WIDTH

PILOT CHANNEL

(SEE TABLE ABOVE)

L

BOTTOM WIDTH

BW < 12 FT

BW = 12 FT - 20 FT

BW > 20 FT 8 FT

6 FT

FLAT BOTTOM

PILOT CHANNEL WIDTH

FT

OPTIONAL

KEYED JOINT.

SEE DETAIL B.

M

ATCH LINE "A"

IN. SEE TYP.

CHANNEL LINING DETAIL.

TYPE B WEEP HOLE

AT 15 FT. O.C.

SEE WEEP HOLE

DETAILS.

TYPE C WEEP HOLE

AT 15 FEET O.C. SEE

WEEP HOLE DETAILS.

DETAIL B

12.

TRIM PVC FLUSH

TO FINISH CONCRETE

SEE STORM SEWER &

RIPRAP DETAIL SHEET

GEOTEXTILE TYP.

FT.3 MIN

TYPE "A"

WEEP HOLE (TYP.)

15 FT.

EX

IS

TI

N

G

8 IN X 3 FT MIN

M

IN

5 MIN

8 MIN. IN.

SEAL SLAB

SEE NOTE 5.

SPECIFY REINFORCING

STEEL, SEE NOTE 11. 2 FT.

3 FT.

SPECIFY REINFORCING

STEEL, SEE NOTE 11.

5 MIN

FT

VARIES

IN

IN.

TYPE A WEEP HOLE

AT 15 FEET O.C.

SEE WEEP HOLE DETAILS.

8 IN X 2 FT MIN

THICKNESS 5 MIN IN.

FT

M

IN

FT

M

IN

REINFORCING STEEL,

SEE NOTE 11.

1 FT-6 IN. MIN.

FT.1 MIN

SPECIFY REINFORCING

STEEL, SEE NOTE 11.

SPECIFY REINFORCING

STEEL, SEE NOTE 11.

M

IN

FT.4 MIN.

FT.4 MIN.

IN.5 MIN.

IN.8 MIN.

FT

M

IN

FT

M

IN

IN.8 MIN.

SPECIFY REINFORCING

STEEL, SEE NOTE 11.

M

ATCH LINE "A"

2 M

IN. FT.

TOEWALL UPSTREAM

& DOWNSTREAM

1 AND 2.

SEE NOTES

5 MIN. IN.

FT

M

IN

12" MIN.

CONNECTION TO EXISTING CONCRETE

EXIST. STEEL

EMBEDMENT DEPTHNEW #5 IN CENTER

OF CONC. LINING

(TYP)

INSTALL NEW REINFORCED CONCRETE LINING

REMOVE EXISTING CONCRETE AND REBAR &

EXISTING CONCRETE

SAWCUT

FULL DEPTH

DRILL EXISTING CONCRETE AND EPOXY GROUT IN PLACE 24" LONG #5 REBAR DOWELS @

18" O.C.; EMBEDMENT DEPTH SHALL BE AS PER EPOXY MANUFACTURER TO FULLY

DEVELOP THE SIZE/GRADE REBAR. CONTRACTOR TO SUBMIT MANUFACTURER'S PRODUCT

DATA FOR EPOXY GROUT PER SPECIFICATION SECTION No. 01330.

1'-0"

6"

10"

45°

USE #8 X 12" DOWELS @ 18" O.C. WITH 6" EMBEDMENT AND NO EPOXY @ EXPANSION JOINTS.* USE EXPANSION JOINTS IN LIEU OF CONSTRUCTION JOINTS WHERE DIRECTED BY ENGINEER.*

5 MIN. IN.

TOP OF CHANNEL

LINING

WHEN PLACING THROUGH EXISTING

CHANNEL LINING, SAW-CUT FULL

DEPTH AND REMOVE 4 FEET ALL

AROUND.

SPECIFY REINFORCING

STEEL, SEE NOTE 11.

8 MIN

6 INCH

MIN

TYP.6 IN.

2 IN.

5 IN.

8 IN.

13.

BAR SIZE #

LAP - SPLICE -

1 FT. 9 IN.

2 FT. 2 IN.

2 FT. 7 IN.

3 FT. 5 IN.

4 FT. 6 IN.

5 FT. 8 IN.

7 FT. 3 IN.

MINIMUM

LENGTHS

6 INCH

SEE NOTE 8.

FOR STRUCTURAL BACKFILL MATERIAL PER SPECIFICATION SECTION 2316, USE CONCRETE COARSE AGGREGATE ASTM C33

SIZE NO. 467. LIMESTONE AND RECYCLED CONCRETE NOT ALLOWED.

CONCRETE CHANNEL LINING PLACED ON CHANNEL OR BASIN SIDE SLOPES MAY BE 5 INCHES OR 6 INCHES IN THICKNESS. THE IFC PLAN SETS FOR EACH SPECIFIC PROJECT SITE WILL CALL OUT THE THICKNESS FOR THAT SPECIFIC PROJECT SITE.

CONCRETE CHANNEL LINING PLACED IN CHANNEL OR BASIN BOTTOMS MAY BE 8 INCHES, 10 INCHES OR 12 INCHES IN THICKNESS. THE IFC PLAN SETS FOR EACH SPECIFIC PROJECT SITE WILL CALL OUT THE THICKNESS FOR THAT SPECIFIC

PROJECT SITE.

14.

IN.8 MIN

PIPE OUTFALL DETAIL

(FOR RCP OUTFALLS 42 INCH DIA. AND LESS)

SEE NOTE 14.

SEE NOTE 14

EXISTING

EXISTING

MATCH

EXISTING

MATCH

EXISTING

MATCH

EXISTING

MATCH

15.

16.

#15

SEE NOTE

#16

SEE NOTE

CONTINUOUS DRAINAGE

GEOCOMPOSITE WITH 8 OZ.

NON-WOVEN GEOTEXTILE.

CONTINUOUS STEEL

6 IN.

1 FT.

FILTER FABRIC

SEE WEEPHOLE

NOTE d.

CONSTRUCTION JOINT

3/4 IN. BITUMINOUS

CENTER DOWEL HORIZONTALLY ON JOINT.

EXPANSION JOINT BARS SHALL BE HELD PARALLEL TO THE FINISHED

1.

2.

CONCRETE THICKNESS (D) DOWEL DIA.

5" - 6" 3/4" 7" - 8" 1"

9" AND UP 1 1/4"

SMOOTH EXPANSION JOINT DOWELS

CONCRETE SURFACE.

SMOOTH BAR

9"

D /2

D /2

DOWEL TYPE EXPANSION JOINT

DOWEL AT

12" C-C

HEAVY PLASTIC

OR STEEL TUBE

3/4" GAP

(ALLOWS DOWEL

BAR TO MOVE)

9" 18"

D

FILTER FABRIC. SEE

WEEP HOLE NOTE d.

9 3/4"

EXPANSION

BOARD

1 FT.

BITUMINOUS

EXPANSION

BOARD

3/4 IN.

6"

THE EXTENT OF THICKENED AREA AROUND PIPE OUTFALLS WILL BE PAID AS THE SPECIFIED CHANNEL LINING THICKNESS FOR

THE ADJACENT CHANNEL LINING.

17.

SEE NOTE 17.

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

NTS

H C

FC

D

S W

PP

P

D

ET

A

IL

S

GRANULAR FILL

SEE SPECIFICATION SECTION NO. 02365-STABILIZED CONSTRUCTION ACCESS.

GEOTEXTILE FOR FULL

WIDTH AND LENGTH OF

STABILIZED CONSTRUCTION

CONSTRUCTION NOTES:

1.

STABILIZED CONSTRUCTION ACCESS

SYMBOL

GRADED TO PREVENT

SEDIMENT FROM

PROVIDE APPROPRIATE TRANSITION

BETWEEN STABILIZED CONSTRUCTION

ACCESS AND EDGE OF ROADWAY.

8 INCHES MINIMUM

50 FT. MAX. 50 FT. MAX.

R O

AD

W

AY

1. SEE SPECIFICATION SECTION NO. 02361-SILT FENCES.

REINFORCED SILT FENCE

EXTEND SILT FENCE FABRIC

FLOW

SILT FENCE FABRIC

INTO TRENCH.

SUPPORT

IN

GRID MESH

SYMBOL

RSF

NOTE:

3. ATTACH SILT FENCE FABRIC TO

WIRE FENCE AND EXTEND INTO

THE TRENCH.

4 IN. X 6 IN. TRENCH UPSLOPE

ALONG LINE OF SUPPORTS.

1. SET SUPPORTS AND EXCAVATE

EXCAVATED SOIL.

4. BACKFILL AND COMPACT THE

2. SECURE WIRE FENCING TO SUPPORTS.

OF SLOPE

SLOPE OR NORMAL

SODDING

PROP. TOP OF SLOPE

SOD

PROP. TOP

SOD

FT.

50 FT.

AS NEEDED

BACKSLOPE SWALE

INTERCEPTOR STRUCTURE AND

INLET PROTECTION (SEE DETAIL "D").

TWO ROWS STAGGERED

SOD PANELS (TYP.)

FLOW

PROP. TOE OF

WHERE NO BACKSLOPE SWALE

EXISTS OR FOR PAVED CHANNEL,

DETAIL "A"

PLACE A DOUBLE ROW OF SOD

SECTION

A SECTION

D

PLAN SECTION

REINFORCED SILT FENCE

6 FT. MAX FOR REINFORCED FENCE.

SPACING

PANELS AT TOP OF SLOPE.

FLOW FLOW

STRUCTURE

IN

TERCEPTOR

FOUR ROWS

SO

D

SO

D SO

D

SO

D SO

D

SO

D SO

D

SO

D

SOD

SOD

SOD

SOD

INTERCEPTOR STRUCTURE

& INLET PROTECTION

STAGGERED

ACCESS.

WATER SURFACE

4 IN.

SEE DETAIL "A"

SEE DETAIL "A"

DETAIL "B"

PLAN

SEE DETAIL "B".

"U"

AS NEEDED

IN

. SOD PANELS

STAGGERED

TWO ROWS

SOD PANELS

IN

SOD

SYMBOL

R O

AD

W

AY

SOD

SOD

SOD

SOD

WIRE OR PLASTIC

IP

SYMBOL

OF SLOPE

PROP. TOE

STAGGERED MIN. TWO ROWS

SOD PANELS (TYP.)

IN

24 IN. 48 IN.

DETAIL "C"

PANELS (2 MIN.)

STAGGERED SOD

STAPLES "U" STAPLES

SOD

ROLLS

"U" STAPLES

48 IN.

"U" STAPLES

INTERVALS

FT.

20 50 FT.

INTERVALS

20 FT. MAX. 20 FT. MAX.

20 FT. MAX.

FOR SOD ROLLS, 24 INCHES WIDE,

PLACE STAPLES ON 48 INCH CENTERS

NEAR THE EDGES. STAGGER STAPLES

ON OPPOSING SIDES. PLACE ADDITIONAL

STAPLES IN CORNERS AT ENDS OF ROLL

AND ONE IN MIDDLE AT BOTH ENDS

OF ROLL.

PROVIDE STAPLES PER SPECIFICATION

SECTION NO. 02922-SOD.

SOD ROLL AS SHOWN IN DETAIL "C"

EQUIVALENT TO TWO ROWS OF SOD

PANELS.

PLACE TWO ROWS OF SOD PANELS ALONG

EDGES OF CONCRETE PAVING AND

STRUCTURES WHERE SOIL IS DISTURBED

EXCEPT BELOW THE NORMAL WATER SURFACE.

NOTES:

F

T.

VA

R

IE

S

DETAIL "D"

EXISTING

GROUND

SWPPP / BMP SIGN AND CONSTRUCTION

SITE NOTICE HOLDER DETAILS

CSN

CSN HOLDER

1'-6"

1' -0

1' -6

45°

NOTE:

CONSTRUCT IN ACCORDANCE WITH

HCFCD SPECIFICATION SECTION

01580 - PROJECT SIGNS.

1.

2.

3.

LEAVING SITE.

M

IN

FLOW

M

IN

FLOW

FLOW

A

A

IN

M

IN

M

AX

EE

E

D

D

M

IN

SCA

4.

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

R O

VE

D

C H

EC

K

ED

PR

EP

A R

ED

D

ES

C R

IP

TI

O N

R

EV

D A

TE

A

PP

R

B R

A

YS

B A

YO

U

M A

JO

R

R

EP

A

IR

S

D

0-

-0 0-

X1

SCALE:

DATE:

OF

SHEET NUMBER

ww w.

hu itt-zo lla rs.

co m

0 R ich mo nd

A ve nu e, Su ite

Ho us ton , T ex as

2-

1.4

.00

D D

J

B P

R G

P

10/28/2025

MACGREGOR SITE PHASING - TO ADDRESS EXISTING SHELF UPLIFT AND LOW-FLOW

ROTATION ON RIGHT SIDE LOOKING UPSTREAM:

MACGREGOR SITE PHASE 1 - DIVERT NORMAL FLOW TO RIGHT SHELF TO REPLACE

EXISTING LOW-FLOW, LEFT SHELF AND LEFT SLOPE LINING:

1A. REMOVE RIGHT SHELF AND SLOPE LINING AS NECESSARY TO INSTALL 12-FT LONG

LATERAL STEEL SHEET PILE TO BOTTOM ELEVATION 12-FT BELOW PROPOSED RIGHT

SIDE TOP OF CONCRETE LINING (TOCL) ELEVATION FOR RIGHT SIDE UPSTREAM AND

DOWNSTREAM CUT-OFF WALLS.

1B. REMOVE RIGHT SHELF LINING AS NECESSARY TO INSTALL 18-FT LONG

LONGITUDINAL STEEL SHEET PILE TO BOTTOM ELEVATION 12-FT BELOW

PROPOSED RIGHT SHELF TOP OF CONCRETE LINING (TOCL) ELEVATION, LEAVING 6-FT

OF SHEET PILE ABOVE ABOVE TOCL FOR CARE OF WATER;

PROTECT AGAINST GROUNDWATER INFILTRATION INTO THE WORK AREA WITH

TEMPORARY SEAL SLAB AROUND SHEET PILE.

1C. REMOVE LOW-FLOW, LEFT SHELF, AND LEFT SLOPE LINING AS NECESSARY TO

INSTALL 18-FT LONG LATERAL STEEL SHEET PILE TO BOTTOM ELEVATION 12-FT

BELOW PROPOSED TOP OF CONCRETE LINING (TOCL) ELEVATION, LEAVING 6-FT OF

SHEET PILE ABOVE ABOVE TOCL FOR CARE OF WATER;

PROTECT AGAINST GROUNDWATER INFILTRATION WITH TEMPORARY SEAL SLAB

AROUND SHEET PILE.

1D. WHILE NORMAL FLOW IS DIVERTED TO THE RIGHT SIDE (BY PILING INSTALLED

UNDER 1B & 1C) REMOVE EXISTING LOW-FLOW, LEFT SHELF AND LEFT SLOPE LINING

AND INSTALL PROPOSED LOW-FLOW, LEFT SHELF AND LEFT SLOPE LINING WITH

WEEP-HOLES FOR HYDROSTATIC RELIEF.

MACGREGOR SITE PHASE 2 - ALOW NORMAL FLOW INTO NEW LOW-FLOW LINING:

2A. AFTER NEW CONCRETE LINING INSTALLED UNDER 1D IS COMPLETE, PROTECT

CONCRETE LINING WHILE CUTTING UPSTREAM AND DOWNSTREAM LATERAL

LOW-FLOW, LEFT SHELF, AND LEFT SLOPE SHEET PILE FLUSH WITH PROPOSED TOCL;

DISPOSE PROPERLY OF THE 6-FT OF SHEET PILE THAT WAS USED FOR TEMPORARY

CARE OF WATER.

2B. AFTER NORMAL FLOW IS RUNNING IN THE NEW LOW-FLOW LINING, PROTECT

CONCRETE LINING WHILE CUTTING LONGITUDINAL SHEET PILE FLUSH WITH

PROPOSED TOCL.

2C. REMOVE EXISTING RIGHT SHELF AND RIGHT SLOPE LINING AND INSTALL

PROPOSED RIGHT SHELF AND LEFT SLOPE LINING WITH WEEP-HOLES FOR

HYDROSTATIC RELIEF.

MACGREGOR PHASING

NTS

PH

A

SI

N

G N

O

TE

S

ROBERT G. POWELL

102329L I C E N S E D

PRO FE S S I O N A L E NG IN

EE

R

S

T A T E O F T EX A S

Huitt-Zollars Inc.

File details come from the government source that posted it. Updated .