105113 METAL LOCKERS.docx

DOCX document 33 KB Posted

Attached to
Y1DA--656-19-307 Remodel of Building 51-1, Eastside at the Saint Cloud VA, Saint Cloud, MN
Solicitation number
36C26325B0007_0005
Issued by

About this file

This document is a technical specification (Section 10 51 13) for metal lockers for a VA Medical Center renovation project in St. Cloud, Minnesota. The specification details requirements for metal lockers to be installed in Locker/Break Rooms and an Honor Guard Room, with specific dimensions and configurations including single and double-tier arrangements. Lockers will be fabricated from cold-rolled steel sheet, featuring channel-formed frames, one-piece doors with multipoint latching, recessed handles, cylinder locks (with master key system), and accessories like coat hooks and identification plates. The lockers will have a baked enamel finish with color selection available from the manufacturer's range. The project is associated with VA Project 656-19-307 for remodeling Building 51-1 Eastside, with the solicitation (36C26325B0007_0005) indicating a bid opening date of June 26, 2025 at 9:00am, to be submitted to Dwayne Brauch at the Department of Veterans Affairs Veterans Health Administration.

View the file

Other files

File Type Posted
36C26325B0007 0005.pdf PDF
Price Breakdown blank.xlsx XLSX spreadsheet
36C26325B0007_1 6.17.2025a.pdf PDF
Memory cabinet measurments.docx DOCX document
Questions Request Form 6172025_ae.doc DOC document
VAAR 852.219-75 Limitations on Subcontracting Cert of Compliance.pdf PDF
Contractor Safety and EMR.pdf PDF
105113 METAL LOCKERS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VAMC St. Cloud, MNVA Project 656-19-307
Remodel Building 51-1 EastsideJune 16, 2025
4801 Veterans DriveCONSTRUCTION PACKAGE
St. Cloud, MN 56303 VA Central Iowa Health Care SystemVA Project 636A-21-109
Building 1 Level 1 Clinics Renovation12-17-2024
13600 30th StreetCD2 100% DESIGN REVIEW

Des Moines, IA 50310

SECTION 10 51 13

METAL LOCKERS

SPEC WRITER NOTES:

1.Use this section only for NCA projects.
2.Delete between //_____// if not applicable to project. Also delete any other items or paragraphs not applicable in the section and renumber paragraphs.

PART 1 – GENERAL

1.1 DESCRIPTION

A. This Section includes //metal lockers for Locker/Break Rooms// //and// //metal lockers for Honor Guard Room//..

1.2 RELATED WORK

A.Furring, blocking, and shims (required for installing metal lockers and concealed within other construction before metal locker installation): Section 06 10 00, ROUGH CARPENTRY.
B.Shop prime painting of steel and ferrous metals: Section 05 50 00, METAL FABRICATIONS.
C.Locker Base: Section 03 30 00, CAST-IN-PLACE CONCRETE.
D.Type of Finish, Color, and Gloss Level of Finish Coat: Section 09 06 00, SCHEDULES AND FINISHES.See Material Schedule in drawings.

1.3 SUSTAINABILITY REQUIREMENTS

A. Materials in this section may contribute towards contract compliance with sustainability requirements. See Section 01 81 13, SUSTAINABLE DESIGN REQUIRMENTS, for project // local/regional materials, // low-emitting materials, // recycled content, // _____//and other requirements.

1.4 SUBMITTALS

A.Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B.Manufacturer’s Literature and Data:
1.Before fabrication of the lockers is started, submit manufacturer’s literature which will be used to determine compliance with submittal requirements.
C.Samples: Prior to fabrication, provide color samples on actual locker material to determine final color selection.

1.5 QUALITY ASSURANCE

A.Installer Qualifications: An authorized representative of metal locker manufacturer for installation and maintenance of units required for this Project.
B.Source Limitations: Obtain metal lockers and accessories through one source from a single manufacturer.
C.Product Options: Drawings indicate size, profiles, and dimensional requirements of metal lockers and are based on the specific system indicated. Refer to Division 1 Section "Product Requirements."
D.Regulatory Requirements: Where metal lockers are indicated to comply with accessibility requirements, comply with the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities (ADAAG)”.

1.6 DELIVERY, STORAGE, AND HANDLING

A.Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for metal locker installation.
B.Deliver master and control keys to Owner by registered mail or overnight package service.

1.7 PROJECT CONDITIONS

A.Field Measurements: Verify the following by field measurements before fabrication and indicate measurements on Shop Drawings:
1.Concealed framing, blocking, and reinforcements that support metal lockers before they are enclosed. Recessed openings.

1.8 COORDINATION

A. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of Work specified in other Sections to ensure that metal lockers can be supported and installed as indicated.

1.9 WARRANTY

A.Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period.
1.Failures include, but are not limited to, the following:
a.Structural failures.
b.Faulty operation of latches and other door hardware.
2.Damage from deliberate destruction and vandalism is excluded.
3.Warranty Period for Knocked-Down Metal Lockers: Two years from date of Substantial Completion.

1.10 APPLICABLE PUBLICATIONS

A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by the basic designation only. Comply with applicable provisions and recommendations of the following, except as otherwise shown or specified.

SPEC WRITER NOTES:

1.Remove reference citations that do not remain in Part 2 or Part 3 of edited specification.
2.Verify and make dates indicated for remaining citations the most current at date of submittal; determine changes from date indicated on the TIL download of the section and modify requirements impacted by the changes.
B.American Society for Testing and Materials (ASTM):
A1008/A1008M-21aSteel Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable
C.Accessibility Standards:
ADAAmericans with Disabilities Act
ADA-ABAAmericans with Disabilities Act and the Architectural Barriers Act
ADAAGAccessibility Guidelines for Buildings and Facilities
D.Metal Finishes Manual for Architectural and Metal Products (NAAMM)

PART 2 – PRODUCTS

2.1 MATERIALS

A.Cold-Rolled Steel Sheet: ASTM A 1008, Commercial Steel (CS) Type B, suitable for exposed applications.
B.Fasteners: Zinc- or nickel-plated steel, slot-less type exposed bolt heads, and self-locking nuts or lock washers for nuts on moving parts.
C.Anchors: Select material, type, size, and finish required for secure anchorage to each substrate.
1.Provide nonferrous-metal or hot-dip galvanized anchors and inserts on inside face of exterior walls and elsewhere as required for corrosion resistance.
2.Provide toothed-steel or lead expansion sleeves for drilled-in-place anchors.

2.2 METAL LOCKERS

A.Locker Arrangement:
1.//Locker/Break Rooms: Single Double tier.//
2.//Honor Guard: Double tier.//

SPEC WRITER NOTES:

1.Confirm sizes.
B.Locker Dimensions:
1.Provide individual units with the following dimensions:
a.Locker Rooms: 18 12 inches wide, 21 inches deep and 72 36 inches high.
b.Honor Guard Rooms: 18 inches wide, 21 inches deep and 36 inches high.
C.Body: Assembled by riveting or bolting body components together. Fabricate from non-perforated, cold-rolled steel sheet with thicknesses as follows:
1.Tops, Bottoms, and Intermediate Dividers: 0.55 mm (0.0209 inch),24-gauge sheet steel with single bend at sides.
2.Backs and Sides: 24-gauge sheet steel 0.55 mm (0.0209 inch) thick, with full-height, double-flanged connections.
3.Shelf: 24-gauge sheet steel 0.55 mm (0.0209 inch) thick, with double bend at front and single bend at sides and back.
D.Frames: Channel formed; fabricated from 1.35 mm (0.0528 inch) thick, cold-rolled steel sheet; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral door strike full height on vertical main frames.
1.Cross Frames between Tiers: Channel formed and fabricated from same material as main frames; welded to vertical frame members.
2.Frame Vents: Fabricate horizontal face frames with vents.
3.Provide resilient bumpers to cushion door closing.
E.Doors: One-piece; fabricated from 1.35 mm (0.0528 inch) thick, cold-rolled steel sheet; formed into channel shape with double bend at vertical edges, and with right-angle single bend at horizontal edges.
1.Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 381 mm (15 inches) wide; welded to inner face of doors.
2.Stiffeners: Manufacturer's standard full-height stiffener fabricated from 1.1 mm (0.0428 inch) thick, cold-rolled steel sheet; welded to inner face of doors.

SPEC WRITER NOTES:

1.Following requirement is uncommon, increased cost and possible special order.
//3.Sound-Dampening Panels: Manufacturer's standard, designed to stiffen doors and reduce sound levels when doors are closed, of die-formed metal with full perimeter flange and sound-dampening material; welded to inner face of doors.//
4.Door Style: Non-perforated panel.
a.Concealed Vents: Slotted perforations in top and bottom horizontal return flanges of doors.
5.Hinges: Self-closing; welded to door and attached to door frame with not less than 2 factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed; fabricated to swing 180 degrees.
6.Continuous Hinges: May be provided if manufacturer's standard; steel continuous hinge.
7.Recessed Door Handle and Latch: Stainless-steel cup with integral door pull, recessed so locking device does not protrude beyond face of door; pry resistant.
8.Multipoint Latching: Finger-lift latch control designed for use with built-in combination locks, built-in key locks, or padlocks; positive automatic and pre-locking.
a.Latch Hooks: Equip doors less than 48 inches(1219 mm) high with 2 latch hooks; fabricated from minimum 0.0966-inch-(2.5-mm-) thick steel; welded or riveted to full-height door strikes; with resilient silencer on each latch hook.
b.Latching Mechanism: Manufacturer's standard rattle-free latching mechanism and moving components isolated with vinyl or nylon to prevent metal-to-metal contact, and incorporating a pre-locking device that allows locker door to be locked while door is open and then closed without unlocking or damaging lock or latching mechanism.
9.Accessible Latching: Provide paddle latch control designed for use with built-in combination locks, built-in key locks, or padlocks; positive automatic and pre-locking at all lockers designated as accessible.
10.Cylinder Locks: Built-in, flush, cam locks with five-pin tumbler keyway, keyed separately and master keyed. Furnish two change keys for each lock and five master keys.
11.Key Type: Flat.
12.Bolt Operation: Manually locking deadbolt.
13.Equipment: Equip each metal locker with identification plate and the following, unless otherwise indicated.
14.Double-Tier Units: One double-prong ceiling hook and two single-prong wall hooks.
F.Accessories:
1.Continuous Sloping Tops: Fabricated from cold-rolled steel sheet, manufacturer's standard thickness, but not less than 0.0329 inch (0.85 mm) thick.
a.Closures: Hipped-end type.
2.Finished End Panels: Fabricated from 0.0209-inch-(0.55-mm-) thick, cold-rolled steel sheet.
3.End Filler Panels:
a.Provide filler panels at each end of locker run to completely fill any residual space between locker units and adjoining walls.
b.Center locker units in recess area.
c.Fabricate from sheet steel matching locker door specification.

SPEC WRITER NOTES:

1.Coordinate base with drawings.
G.Base: Install lockers on constructed concrete base provided under other specification division.18-gauge closed metal front and end bases, finished to match lockers.
H.Finish: Baked enamel.
1.Color(s): As scheduled or as selected from manufacturer's full color range.

2.3 FABRICATION

A.General: Fabricate metal lockers square, rigid, and without warp; with metal faces flat and free of dents or distortion. Make exposed metal edges free of sharp edges and burrs, and safe to touch.
1.Form body panels, doors, shelves, and accessories from one-piece steel sheet, unless otherwise indicated.
2.Provide fasteners, filler plates, supports, clips, and closures as required for a complete installation.
B.Unit Principle: Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments.
C.Knocked-Down Construction: Fabricate metal lockers for nominal assembly at Project site using nuts, bolts, screws, or rivets. Factory weld frame members together, to form a rigid one-piece assembly.
D.Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.
E.Coat Rods: Fabricated from 19 mm (3/4 inch) diameter steel; chrome finished.
F.Identification Plates: Manufacturer's standard etched, embossed, or stamped aluminum plates; with numbers and letters at least 9 mm (3/8 inch) high.
G.Continuous Base: Formed into channel or Z profile for stiffness, and fabricated in lengths as long as practicable to enclose base and base ends of metal lockers; finished to match lockers.
H.Continuous Sloping Tops: Fabricated in lengths as long as practicable, without visible fasteners at splice locations; finished to match lockers.
1.Sloped top corner fillers, mitered.
I.Finished End Panels: Designed for concealing unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of non-recessed metal lockers; finished to match lockers.
1.Provide one-piece panels for double-row (back-to-back) locker ends.

2.4 STEEL SHEET FINISHES

A.General: Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.
B.Factory finish steel surfaces and accessories except stainless-steel and chrome-plated surfaces.
C.Surface Preparation: Clean surfaces of dirt, oil, grease, mill scale, rust, and other contaminants that could impair paint bond. Use manufacturer's standard methods.
D.Baked-Enamel Finish: Immediately after cleaning, pre-treating and phosphatizing, apply manufacturer's standard thermosetting baked-enamel finish. Comply with paint manufacturer's written instructions for application, baking, and minimum dry film thickness.

PART 3 – EXECUTION

3.1 EXAMINATION

A.Examine walls, floors, and support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of work.
B.Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A.General: Install level, plumb, and true; shim as required, using concealed shims:
1.Anchor locker runs at ends and at intervals recommended by manufacturer, but not more than 910 mm (36 inches) o.c. Install anchors through backup reinforcing plates, channels, or blocking as required to prevent metal distortion, using concealed fasteners.
2.Anchor single rows of metal lockers to walls near top and bottom of lockers.
B.Knocked-Down Metal Lockers: Assemble knocked-down metal lockers with standard fasteners, with no exposed fasteners on door faces or face frames.
C.Equipment and Accessories: Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates.
1.Attach hooks with at least two fasteners.
2.Attach door locks on doors using security-type fasteners.
3.Identification Plates: Identify metal lockers with identification indicated on Drawings.
a.Attach plates to each locker door, near top, centered, with at least two aluminum rivets.
4.Attach sloping top units to metal lockers, with closures at exposed ends.
5.Attach finished end panels with fasteners only at perimeter to conceal exposed ends of non-recessed metal lockers.

3.3 ADJUSTING, CLEANING, AND PROTECTION

A.Clean, lubricate, and adjust hardware. Adjust doors and latches to operate easily without binding. Verify that integral locking devices operate properly.
B.Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit metal locker use during construction.
C.Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by metal locker manufacturer.

- - - E N D - - -