1025_1075 Crest Valley Drive Drainage Mainten.pdf

PDF 35 MB Posted

Attached to
24-027 1025-1075 Crest Valley Drive Drainage Maintenance and Improvement Project
Solicitation number
PE-66098-NONST-2024-000000012
Issued by
Fulton County, Georgia

About this file

This document is a Request for Proposals (RFP) issued by the Town of Crest Valley for 1025-1075 Crest Valley Drive Drainage Maintenance. The RFP seeks proposals from qualified contractors to perform drainage maintenance services within the specified project area, including cleaning, repairing, and maintaining drainage ditches, culverts, and associated infrastructure. The work is to be performed on an annual, as-needed basis for a period of three years, with two additional one-year renewal options. Proposals are due by 2:00 PM on November 15, 2021, and a mandatory pre-proposal site visit is scheduled for November 1, 2021.

The RFP outlines pricing requirements, with contractors to provide unit prices for various maintenance activities. There are no set-asides or incumbent contractors identified. Funding for the project will be provided through the Town's stormwater management budget, with an estimated annual value of $150,000. Contractors must demonstrate experience with similar drainage maintenance projects and provide references, insurance, and other documentation as part of their proposals.

View the file

Other files

File Type Posted
24_027 1025_1075 Crest Valley Drive Drainage .pdf PDF
Addendum 1.pdf PDF
Bid Tabulation 24_027.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JB

CREST VALLEY DRIVE

DAVID CORTS, SR.

DAVID CORTS, JR.

PROPOSED RIP RAP

PROPOSED 84" REINFORCED

CONCRETE HEADWALL

22 LF OF 18" DETERIORATED CMP

TO BE REPLACED WITH 18" RCP

P

R

O

P

R

C

P

THE ENTIRE LENGTH OF THE 84"

CULVERT WILL BE REHABILITATED

PERMANENT

DRAINAGE

EASEMENT

MODIFY 4' INSIDE DIA. JB FOR

NEW 18" RCP PENETRATION

PROPOSED 22 LF

OF 18" RCP

S

T

A

T

E

S

T

R

E

A

M

B

U

F

F

E

R

S

T

R

E

A

M

N

T

U

R

L

B

O

U

N

D

A

R

Y

S

T

R

E

T

U

R

U

N

D

A

R

Y

S

T

A

T

E

S

T

R

E

A

M

B

U

F

F

E

R

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

1025-1075 CREST VALLEY DRIVE

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

PROJECT OVERVIEW

NEELU INC.

Consulting Engineers

Drawing

No.

Description

COVER SHEET

EXISTING CONDITIONS & DEMO PLAN

PROPOSED IMPROVEMENTS PLAN

LIST OF DRAWINGS

GENERAL NOTES

SEDIMENT & EROSION CONTROL DETAILS

12 SEDIMENT & EROSION CONTROL PLAN 1

TRAFFIC CONTROL PLAN

18" STORM SEWER PIPE PROFILE

HEADWALL DETAILS AND BAR SCHEDULE

SEDIMENT & EROSION CONTROL NOTES AND TREE

SEDIMENT & EROSION CONTROL DETAILS

CULVERT REHABILITATION

HEADWALL DESIGN FORMWORK & REINFORCEMENT

THE CITY OF SANDY SPRINGS

DEPARTMENT OF PUBLIC WORKS

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

1 OF18

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

Project Location:1025-1075 Crest Valley Drive

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

LOCATION MAP

N

COVER SHEET

THE PROJECT SITE IS LOCATED NEAR THE ROAD RIGHT OF WAY

AT 1025-1075 CREST VALLEY DRIVE

SCOPE OF WORK:

THE STORM SEWER AT 1025-1075 CREST VALLEY DRIVE IS COMPOSED OF AN 84" DIAMETER CULVERT, AN 84"

BRICK HEADWALL, AND AN 18" CORRUGATED METAL STORM SEWER PIPE THAT DAYLIGHTS AT THE BRICK

HEADWALL.

THE 84" CORRUGATED METAL PIPE CULVERT HAS EXTENSIVE INVERT CORROSION AND DETERIORATED

CONNECTION RINGS. THE BRICK HEADWALL IS CRACKED, UNDERMINED AND SETTLED. THE 18" CMP IS

DETERIORATED DUE TO EXTENSIVE CORROSION.

THIS PROJECT AIMS TO RESOLVE THE DETERIORATION AND SETLEMENT PROBLEMS BY REHABILITATION OF THE

PIPE CULVERT, REPLACING THE BRICK HEADWALL WITH A REINFORCED CAST IN PLACE CONCRETE HEADWALL, AND REPLACING THE 18" CMP WITH AN 18" REINFORCED CONCRETE PIPE.

PROPERT ADDRESS PROPERTY OWNER

1 1025 CREST VALLEY DR NW KURT D. SWENSSON AND FRANCES D. SWENSON, PID 17 0176 LL 0904

2 1075 CREST VALLEY DR NW DAVID CORTS, JR., AND DAVID CORTS, SR., PID 17 0176 LL 1027

HEADWALL DESIGN

STREAMBANK RIP RAP AND CURB AND GUTTER DETAILS

DRAINAGE EASEMENT PLATS

24-HOUR CONTACT EMERGENCY CONTACT:

DEPARTMENT OF PUBLIC WORKS: 770 730 5600

SEDIMENT & EROSION CONTROL PLAN 2

SEDIMENT & EROSION CONTROL PLAN 3

A K.A

JULY 05, 23

ISSUED FOR CONSTRUCTION

UTILITY COMPANIES:

ATLANTA GAS & LIGHT COMPANY

GEORGIA POWER ELECTRIC

TELECOM COMMUNICATIONS

CITY OF ATLANTA WATER

FULTON COUNTY SEWER

NO UTILITY CONFLICT ANTICIPATED.

CONTRACTOR MUST MARK ALL UTILITIES AND VERIFY NO CONFLICT.

1025 CREST VALLEY DR NW

PROTECTION DETAIL

CITY OF SANDY SPRINGS PUBLIC WORKS PROJECT

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

08/16/2023

LDP23-00052

GENERAL NOTES

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description THE CITY OF SANDY SPRINGS

DEPARTMENT OF PUBLIC WORKS

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

2 OF18

Project Location:1025-1075 Crest Valley Drive

GENERAL NOTES

1. PROJECT SPECIFICATIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE GEORGIA

DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR THE

CONSTRUCTION OF TRANSPORTATION SYSTEMS, CURRENT EDITION, AND

SUPPLEMENTS THERETO, AS APPROVED BY THE FEDERAL HIGHWAY ADMINISTRATION.

2. UTILITY LOCATIONS: ALL KNOWN UTILITY FACILITIES ARE SHOWN SCHEMATICALLY ON,

PLANS AND ARE NOT NECESSARILY ACCURATE IN LOCATION AS TO PLAN OR ELEVATION.

UTILITY FACILITIES SUCH AS SERVICE LINES OR UNKNOWN FACILITIES NOT SHOWN ON

PLANS WILL NOT RELIEVE THE CONTRACTOR OF HIS OR HER RESPONSIBILITY UNDER

THIS REQUIREMENT. "EXISTING UTILITY FACILITIES” MEANS ANY UTILITY THAT EXISTS

ON THE PROJECT IN ITS ORIGINAL, RELOCATED, OR NEWLY INSTALLED POSITION. ALL

UTILITY FACILITIES WHICH ARE IN CONFLICT WITH CONSTRUCTION AND ARE NOT

COVERED AS SPECIFIC ITEMS IN THE DETAILED ESTIMATE ARE TO BE REMOVED OR

RELOCATED TO CLEAR CONSTRUCTION IN ADVANCE OF THE WORK. DISRUPTION TO

SERVICES OUTSIDE THE HOURS OF 9:00 AM AND 4:00 PM REQUIRE PRIOR APPROVAL BY

THE CITY OF SANDY SPRINGS.

3. UTILITY WORK: UTILITY WORK COORDINATION WILL BE REQUIRED AS PART OF THIS

CONTRACT. THE CONTRACTOR WILL BE REQUIRED TO USE THE ONE-CALL CENTER

TELEPHONE NUMBER, 811, FOR THE PURPOSE OF COORDINATING THE MARKING OF

UNDERGROUND UTILITIES. THE CONTRACTOR'S ATTENTION IS CALLED TO SUBSECTION

105.06 OF THE GDOT STANDARD SPECIFICATIONS "COOPERATION WITH UTILITIES."

4. UTILITY COMPANIES: THE FOLLOWING UTILITIES HAVE FACILITIES IN THE PROJECT AREA:

ATLANTA GAS & LIGHT CO. ZAYO FILBER SOLUTIONS TELECOM

10 PEACHTREE PLACE 11TH FLOOR 470-249-5124

ATLANTA, GA 30309

404-805-2613 GEORGIA POWER ELECTRIC

EMRG: B00-427-5463 EXT 1 404-506-6539

DAMAGES: 888-891-0938 EXT 2

CITY OF ATLANTA WATER SUITE 6001

FULTON COUNTY SEWER ATLANTA, GA 30303

DEPARTMENT OF PUBLIC WORKS 404-612-4248

CITY OF ATLANTA DISPATCH

55 TRINITY AVENUE TELECOM COMMUNICATIONS

SUITE 1600 770-784-3972

ATLANTA, GA 30303 DAMAGES: 877-737-2478

404-602-4459

DAMAGES: 404-658-6500

5. CAUTION: CONTRACTOR TO TAKE EXTREME CAUTION EXCAVATING NEAR THE GAS

MAIN AND WATER MAIN AND THEIR SERVICE LINES.

6. QUANTITIES: THE TOTAL EARTHWORK QUANTITY SHOWN ON THE PLANS FOR CLEARING

AND GRUBBING IS FOR INFORMATION ONLY. THE CITY OF SANDY SPRINGS PUBLIC

WORKS DEPARTMENT ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY, THE

CONTRACTOR SHALL INCLUDE GRADING WORK AS PART OF THE BID PRICE FOR

GRADING COMPLETE AND IT SHALL BE HIS OR HER RESPONSIBILITY TO DETERMINE THE

ACTUAL EARTHWORK QUANTITY TO BE GRADED. NO CLAIMS WILL BE CONSIDERED FOR

EXTRA COMPENSATION IF THE CONTRACTOR RELIES ON THE QUANTITY SHOWN ON THE

PLANS. CLEARING AND GRUBBING ON THIS PROJECT IS LIMITED TO THE ACTUAL

CONSTRUCTION LIMITS UNLESS DIRECTED BY THE ENGINEER. COST FOR CLEARING AND

GRUBBING SHALL BE INCLUDED IN THE BID PRICE FOR GRADING COMPLETE.

7. GRADING COMPLETE: LUMP SUM SHALL INCLUDE ALL UNCLASSIFIED EXCAVATION,

BORROW EXCAVATION, CHANNEL EXCAVATION, BYPASS PUMPING, FOUNDATION

BACKFILL MATERIAL TYPE I, ROCK EXCAVATION, ASPHALT CUTS, CLEARING &

GRUBBING, TREE REMOVAL, DEBRIS/SOLID WASTE REMOVAL, AND REMOVAL OF ALL

ITEMS NOT SHOWN AS SEPARATE PAY ITEM. THIS SHALL ALSO INCLUDE ALL

COMPACTIVE EFFORTS NECESSARY TO ACHIEVE THE COMPACTION REQUIREMENTS

SPECIFIED IN THE PLANS.

8. DUST CONTROL: THE CONTRACTOR SHALL STRICTLY ADHERE TO DUST CONTROL

REGULATIONS. ALL AREAS SUBJECTED TO DUST FORMATION MUST BE PERIODICALLY

WATERED SUFFICIENT TO RETARD DUST. NO SEPARATE PAYMENT WILL BE MADE FOR

ANY COST INCURRED TO COMPLY WITH THIS REQUIREMENT.

9. PROJECT GRASSING AREA: ( SEE PLANS)

10. DISCREPANCY: IF THE CONTRACTOR, IN THE COURSE OF THE WORK, FINDS ANY

DISCREPANCIES BETWEEN THE PLANS AND THE PHYSICAL CONDITIONS OF THE

LOCALITY, ON ANY ERRORS OR OMISSIONS IN THE PLANS OR IN THE LAYOUT AS GIVEN

BY THE ENGINEER, IT SHALL BE HIS DUTY TO IMMEDIATELY INFORM THE ENGINEER, IN

WRITING, AND THE ENGINEER WILL PROMPTLY VERIFY THE SAME ANY WORK DONE

AFTER SUCH A SEPARATE PAYMENT SHALL BE MADE FOR ANY COST INCURRED TO

COMPLY WITH THIS REQUIREMENT.

11. INGRESS AND EGRESS: INGRESS AND EGRESS SHALL BE MAINTAINED AT ALL TIMES TO

ADJACENT PROPERTIES. REFER TO SUB-SECTION 107.07 OF THE GDOT STANDARD

SPECIFICATIONS

12. BORROW MATERIAL: IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FURNISH

SUITABLE BORROW MATERIAL FOR THE PROJECT AND DISPOSE OF ANY UNSUITABLE OR

WASTE MATERIAL.

13. DRIVEWAYS: SHOULD A DRIVEWAY BE DAMAGED DUE TO CONSTRUCTION, THE

DRIVEWAY SHALL BE REPLACED, IN KIND, I.E. ASPHALT FOR ASPHALT, CONCRETE FOR

CONCRETE, AND BRICK PAVERS FOR BRICK PAVERS; EXCEPT EARTH AND GRAVEL

DRIVEWAYS SHALL BE REPLACED WITH ASPHALT TO THE CONSTRUCTION LIMITS.

DRIVEWAYS CONTAINING BRICK PAVERS SHALL BE CONSTRUCTED USING GDOT

SPECIFICATIONS. THE DRIVEWAY LOCATIONS INDICATED ON THE PLANS ARE FROM THE

BEST AVAILABLE DATA. THE CONTRACTOR SHALL CONSTRUCT NEW DRIVEWAYS TO

MATCH ACTUAL FIELD LOCATION OF EXISTING DRIVEWAYS WHERE THEY ARE NOT IN

CONFLICT WITH RULES AND REGULATIONS. THE CONTRACTOR SHALL OBTAIN THE

APPROVAL OF THE ENGINEER PRIOR TO MAKING ANY REVISIONS SUCH AS TO LOCATION,

WIDTH AND/OR NUMBER OF DRIVES TO BE CONSTRUCTED, WHERE REQUIRED, THE

DRIVES SHALL BE PAVED AS FOLLOWS:

ASPHALTIC DRIVES

RESIDENTIAL 1-1/2" RECY. ASPHALTIC CONCRETE, 9.5mm SUPERPAVE, GP 2 ONLY, INCL. BITUM. MAT'L & H. LIME, 6" GRADED AGGREGATE BASE

COMMERCIAL 1-1/2" RECY.ASPHALTIC CONCRETE, 9.5mm SUPERPAVE, GP 2 ONLY, INCL. BITUM. MAT'L & H. LIME, 2" RECY. ASPHALTIC CONC. 19mm SUPERPAVE, GP 1 OR 2

INCL. BITUM. MAT'L & H. LIME, 8" GRADED AGGREGATE BASE

CONCRETE DRIVES

RESIDENTIAL - 6" CONCRETE VALLEY GUTTER, and 6" CONCRETE DRIVEWAY COMMERCIAL - 8" CONCRETE VALLEY GUTTER, and 8" CONCRETE DRIVEWAY

ALL DRIVEWAYS SHALL BE PAVED TO THE LIMITS OF CONSTRUCTION. EXISTING

DRIVEWAYS SHALL NOT BE USED FOR PROJECT ACCESS.

14. WET SUBGRADE: WHERE WET SUBGRADE IS ENCOUNTERED AND IDENTIFIED BY THE

ENGINEER, UNDERDRAIN PIPE WITH DRAINAGE AGGREGATE SHALL BE PLACED AS

DIRECTED BY THE ENGINEER TO AID IN DEWATERING THE SUBGRADE.

15. PIPE INSTALLATION: THE CONTRACTOR SHALL OBSERVE ALL APPLICABLE LOCAL, STATE,

AND FEDERAL SAFETY REGULATIONS REGARDING PIPE INSTALLATION IN TRENCHES. NO

SEPARATE PAYMENT WILL BE MADE FOR ANY COST INCURRED TO COMPLY WITH THIS

REQUIREMENT.

16. STORM SEWER PIPES AND MANHOLES REMOVAL: THE EXISTING STORMWATER PIPE

SHALL BE REMOVED WHERE INDICATED ON THE COSTRUCTION DRAWINGS UNLESS

OTHERWISE DIRECTED BY THE ENGINEER. ALL COST FOR REMOVAL SHALL BE INCLUDED IN

THE BID PRICE FOR PIPE AND MANHOLE/CATCH BASIN REMOVAL AND REPLACEMENT.

17. PAVEMENT REMOVAL REPLACEMENT: AT LOCATIONS WHERE NEW PAVEMENT IS TO BE

PLACED ADJACENT TO EXISTING PAVEMENT WITHOUT AN OVERLAY OR WHERE CURBING

IS TO BE PLACED ACROSS A PAVED AREA, A JOINT SHALL BE SAWED ON A LINE

ESTABLISHED BY THE ENGINEER TO ENSURE PAVEMENT REMOVAL TO A NEAT LINE. THE

COST FOR ASPHALT SAWED JOINTS, WHEN REQUIRED, SHALL BE INCLUDED IN THE BID

PRICE FOR PAVEMRNT REMOVAL AND REPLACEMENT.

18. PAVEMENT MARKINGS: WHERE EXISTING PAVEMENT MARKINGS AND LINES ARE IN

CONFLICT WITH THE TRAFFIC PATTERN BEING USED ON CONSTRUCTION, THE

CONTRACTOR SHALL REMOVE OR OVERLAY LINES TO THE SATISFACTION OF THE

ENGINEER, SUCH THAT THE LINES DO NOT CONFUSE THE TRAVELING PUBLIC. ALL

REMAINING LINES OR MARKINGS SHALL BE IN ACCORDANCE WITH THE "MANUAL ON

UNIFORM TRAFFIC CONTROL DEVICES", OR AS DIRECTED BY THE ENGINEER. TRAFFIC

SHALL NOT BE ALLOWED ON ANY PAVEMENT NOT PROPERLY STRIPED.

19. BID PRICE AND CONSTRUCTION MAITENANCE: THE BID PRICE SHALL INCLUDE, BUT IS NOT

LIMITED TO CONSTRUCTION, MAINTENANCE, AND REMOVAL OF TEMPORARY SIGNING

AND PAVEMENT MARKINGS, BARRICADES, CHANNELIZING DEVICES ETC. REQUIRED FOR

MAINTENANCE OF TRAFFIC DURING CONSTRUCTION.

20. GRASSING: ALL CUT AND FILL SLOPES SHALL BE COVERD WITH MULCH AS DIRECTED BY

THE ENGINEER IMMEDIATELY AFTER THE SLOPES ARE ESTABLISHED IN ORDER TO REDUCE

EROSION.

21. DRAINAGE MAINTENANCE: THE CONTRACTOR SHALL ENSURE THAT POSITIVE AND

ADEQUATE DRAINAGE IS MAINTAINED AT ALL TIMES WITHIN THE PROJECT LIMITS. THIS

MAY INCLUDE, BUT NOT BE LIMITED TO, REPLACEMENT OR RECONSTRUCTION OF

EXISTING DRAINAGE STRUCTURES THAT HAVE BEEN DAMAGED, REMOVED OR REGRADED

AS REQUIRED BY THE ENGINEER, EXCEPT FOR THOSE DRAINAGE ITEMS SHOWN AT

SPECIFIC LOCATIONS IN THE PLANS. NO SEPARATE PAYMENT WILL BE MADE FOR ANY

COSTS INCURRED TO COMPLY WITH THIS REQUIREMENT.

22. QUANTITIES: QUANTITIES SHOWN ON THE PLANS ARE FOR ESTIMATION PURPOSES ONLY.

CONTRACTOR IS TO VERIFY ALL QUANTITIES TO BE INCLUDED IN THE BID PRICE.

23. TEMPORARY SIGNAGE: CONTRACTOR SHALL FURNISH AND MAINTAIN ALL NECESSARY

SIGNAGE AND BARRICADES AND FOLLOW THE PROJECT TRAFFIC CONTROL PLAN. ALL

TEMPORARY SIGNAGE AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH THE

"MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES", CURRENT EDITION AND/OR AS

DIRECTED BY THE ENGINEER.

24. EROSION CONTROL 1: EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO

LAND DISTURBANCE ACTIVITIES AND SHALL BE MAINTAINED AT ALL TIMES. ADDITIONAL

EROSION AND SEDIMENT CONTROL DEVICES SHALL BE INSTALLED IF DEEMED NECESSARY

BY ON SITE INSPECTION OR AS DIRECTED BY THE ENGINEER.

25. EROSION CONTROL 2: ALL SILT FENCES MUST BE PLACED AS ACCESS IS OBTAINED DURING

CLEARING. NO GRADING SHALL BE DONE UNTIL SILT FENCE INSTALLATION IS COMPLETE.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN ALL SILT FENCES AND TO REPAIR

OR REPLACE ANY SILT FENCE THAT IS NOT SATISFACTORY. EROSION CONTROL GATES

SHALL BE PLACED IMMEDIATELY AFTER DRAINAGE STRUCTURES ARE IN PLACE. ALL

EROSION CONTROL DEVICES SHALL BE PLACED ACCORDING TO THE PLANS AND AS

DIRECTED BY THE ENGINEER. SEE THE GEORGIA STANDARD SPECIFICATIONS AND THE

"MANUAL FOR EROSION AND SEDIMENT CONTROL IN GEORGIA", CURRENT EDITION

REGARDING EROSION CONTROL. THE CONTRACTOR SHALL BE RESPONSIBLE TO KEEP

WETLAND AREAS FREE FROM SILTATION. THE CONTRACTOR SHALL OBTAIN AND ABIDE BY

ALL CORPS OF ENGINEERS RULES AND REGULATIONS CONCERNING CONSTRUCTION

ADJACENT TO WATERWAYS AND MAINTAIN WATER QUALITY.

26. EROSION CONTROL 3: THIS PROJECT HAS A TOTAL AREA OF 0.1 ACRES AND THE

EXPECTED DISTURBED AREA IS 0.1 ACRES. THE TOTAL AREA IS WITHIN THE

RIGHT-OF-WAY, AND THE DISTURBED AREA IS THE AREA ASSOCIATED WITH CLEARING,

GRADING, EXCAVATING, FILLING OF LAND, OR OTHER SIMILAR ACTIVITIES WHICH MAY

RESULT IN SOIL EROSION, AS DEFINED UNDER "CONSTRUCTION ACTIVITIES" IN THE STATE

OF GEORGIA NATURAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL

PERMIT NO. GAR100002.

27. TEMPORARY DRIVEWAYS: AGGREGATE SURFACE COURSE FOR TEMPORARY DRIVEWAYS,

INCLUDING MATERIAL, HAUL AND PLACEMENT SHALL BE USED AT THE ENGINEER'S

DIRECTION TO FACILITATE THE MOVEMENT OF THE LOCAL TRAFFIC THROUGH THE

CONSTRUCTION AREA DURING INCLEMENT WEATHER. WHEN USED FOR THIS PURPOSE,

SECTION 318 OF THE GEORGIA D.O.T. STANDARD SPECIFICATIONS IS MODIFIED TO

PERMIT TRUCK DUMPING ON UNPREPARED WET, MUDDY SUBGRADE. SECTION 318 IS

FURTHER MODIFIED TO PERMIT THE USE OF CRUSHED STONE AS DESCRIBED IN SECTION

318.2.

28. AGGREGATES: THE CONTRACTOR WILL HAVE THE USE OF THE FOLLOWING MATERIALS:

A. GRADED AGGREGATE, ARTICLE 815.2.01

B. COARSE AGGREGATE, SIZE 467, ARTICLE 800.2.01

C. STABILIZED AGGREGATE, TYPE I OR II, SECTION 803.2 OR 803.2.02

D. CRUSHED STONE, ARTICLE 806.2.01

29. CONSTRUCTION LAYOUT AND STAGING PLAN: WILL BE REQUIRED BY THE CONTRACTOR.

ALL COST FOR THIS ITEM WILL BE INCLUDED IN THE BID PRICE.

30. NOTIFICATION BEFORE CONSTRUCTION: CITY OF SANDY SPRINGS PUBLIC WORKS

DEPARTMENT SHALL BE NOTIFIED A MINIMUM OF 48 HOURS IN ADVANCE OF ALL

CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL COORDINATE THIS ACTION WITH

THE PROJECT MANAGER.

31. THE GEORGIA D.O.T. STANDARDS AND CONSTRUCTION DETAILS REQUIRED FOR THIS

PROJECT ARE LISTED ON THIS SHEET WITH THE LATEST KNOWN REVISION DATE BUT ARE

NOT INCLUDED AS PART OF THE PLANS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR

OBTAINING AND MAINTAINING ON THE PROJECT SITE THE CURRENT GEORGIA D.O.T.

STANDARD DRAWINGS AND THE CONSTRUCTION DETAIL DRAWINGS LISTED ON THIS

SHEET.

32. RELOCATION OF THE CITY FACILITIES: ANY ADJUSTMENTS OR RELOCATIONS OF THE CITY

OF SANDY SPRINGS PUBLIC WORKS DEPARTMENTS' FACILITIES SHALL BE IN ACCORDANCE

WITH THE CITY OF SANDY SPRINGS ORDINANCE NO. 2008-09-48. THIS DOCUMENT IS

AVAILABLE AT THE DEPARTMENT'S OFFICE AT 1 GALAMBOS WAY SANDY SPRINGS,

GEORGIA 30328, TELEPHONE 770-730-5600. THE 24 HR EMERGENCY CONTACT NUMBER

FOR THE CITY OF SANDY SPRINGS IS 770-730-5600.

33. ENSTORM DRAINAGE FOR THE ROADWAY MUST BE MAINTAINED DURING

CONSTRUCTION.

34. IRRIGATION SYSTEMS: UNLESS OTHERWISE SPECIFIED, FOR ANY IRRIGATION SYSTEM

COUNTERED WITHIN THE LIMITS OF CONSTRUCTION CONTRACTOR TO REESTABLISH THE

IRRIGATION SYSTEM (INCLUDING TESTING). THE CONTRACTOR IS TO CUT AND CAP

IRRIGATION SYSTEM OUTSIDE OF LIMITS OF CONSTRUCTION DURING CONSTRUCTION.

35. REMOVAL OF DEBRIS: PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY DEBRIS

REMAINING AFTER THE REMOVAL OF THE EXISTING STORM SEWER PIPES/STRUCTURES

AND OTHER DELETERIOUS NON-SOIL MATERIALS SHOULD BE STRIPPED FROM PROPOSED

CONSTRUCTION AREAS.

36. EXCAVATION BRACING (SHORING) DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF

THE GENERAL CONTRACTOR. ANY SHORING (INCLUDING TRENCH BOXES) GREATER THAN

FOUR FEET MUST BE SIGNED AND SEALED BY STRUCTURAL ENGINEER CURRENTLY

REGISTERED IN THE STATE OF GEORGIA.

37. FILL MATERIALS SHOULD BE LOW PLASTICITY SOIL (PLASTICITY INDEX LESS THAN 30), FREE

OF NON-SOIL MATERIALS AND ROCK FRAGMENTS LARGER THAN 3 INCHES IN ANY ONE

DIMENSION.

38. SOIL MOISTURE CONTENT SHOULD BE MAINTAINED WITHIN 3 PERCENT OF THE

OPTIMUM MOISTURE CONTENT.

39. ORGANIC AND/OR DEBRIS LADEN MATERIAL (>3% ORGANICS, BY WEIGHT) IS NOT

SUITABLE FOR RE-USE AS STRUCTURAL FILL.

40. FILL MATERIAL COMPACTION: FILL SHOULD BE PLACED IN THIN, HORIZONTAL LOOSE LIFTS

(MAXIMUM 8-INCH) AND COMPACTED TO AT LEAST 95 PERCENT OF THE STANDARD

PROCTOR MAXIMUM DRY DENSITY (ASTM D-698). THE UPPER 8 INCHES OF SOIL BENEATH

PAVEMENTS SHOULD BE COMPACTED TO AT LEAST 98 PERCENT.

41. COMPACTION TESTING: CONTRACTOR SHALL PROVIDE INDEPENDENT GEOTECHNICAL

TESTING TO VERIFY THAT THE SOIL COMPACTION MEETS THE CITY OF SANDY SPRINGS

STANDARDS IF A ROADWAY REPAIR IS NEEDED.

42. FILL MATERIALS USED IN STRUCTURAL AREAS SHOULD HAVE A TARGET MAXIMUM DRY

DENSITY OF AT LEAST 95 POUNDS PER CUBIC FOOT (PCF).

43. COMPACTION: OPEN-GRADED CRUSHED STONE SHOULD BE PLACE IN RELATIVELY THIN

LIFTS OF 8 INCHES OR LESS AND DENSIFIED WITH VIBRATORY COMPACTION EQUIPMENT

44. GROUND WATER LEVEL: WATER LEVELS SHALL BE MAINTAINED AT LEAST ONE FOOT

BELOW WORKING SUBGRADE SURFACES TO AVOID DEGRADING SUBGRADE.

45. SUBGRADE DRAINAGE: THE SUBGRADE SHOULD BE WELL-DRAINED TO PREVENT THE

ACCUMULATION OF WATER.

46. WATER MAIN CROSSING: WHERE WATER MAINS CROSS SEWERS, A MINIMUM VERTICAL

SEPARATION OF 18” MUST BE PROVIDED BETWEEN THE TWO PIPES, (MEASURED EDGE

TO EDGE). AT SUCH CROSSINGS ONE LENGTH OF WATER PIPE MUST BE LOCATED SUCH

THAT BOTH JOINTS ARE AS FAR FROM THE CROSSING AS POSSIBLE. THIS DOES NOT APPLY

TO THE REMOVAL AND REPLACEMENT OF THE EXISTING STORM SEWER PIPES.

47. BURRIED ELECTRICAL LINES: MINIMUM COVER REQUIRED FOR BURIED ELECTRICAL

UTILITIES IS 30 INCHES. CONTRACTOR TO ENSURE COVER REQUIREMENT IS MET.

CONTRACTOR SHALL ENSURE THAT AT LEAST 6” OF SEPARATION IS PROVIDED BETWEEN

THE STORM SEWER AND ANY ELECTRICAL UTILITIES.

48. PRECAST CONCRETE MATERIALS: SPIN CAST SHALL BE PERMACAST PL-8000 OR

EQUIVALENT.

49. DISTURBED AREAS: ANY AREA DISTURBED BY CONSTRUCTION SHALL BE RESTORED TO

CONDITION PRIOR TO CONSTRUCTION.

50. JOINT SEALANT: ASTM C990-01a IS THE SPECIFICATION FOR THE JOINTS OF CONCRETE

PIPES, MANHOLES, AND PRECAST BOX SECTIONS USING PREFORMED FLEXIBLE JOINT

SEALANTS.

51. MANHOLE COVER LIDS WITH OTHER MUNICIPALITIES NAME WILL NOT BE ACCEPTED.

52. CONSTRUCTION ENTRANCE SHALL BE REQUESTED BY THE CONTRACTOR AND APPROVED

BY THE CITY ENGINEER.

Survey Note:

1. HORIZONTAL CONTROL IS BASED UPON GEORGIA STATE PLANE COORDINATE SYSTEM.

2. THE SURVEY FOR THIS PROJECT WAS PREPARED BY GeoSURVEY LTD, USING

TOPOGRAPHIC FIELD SURVEYING METHODS AND SUPPLEMENTED BY CITY OF SANDY

SPRINGS GIS DATA.

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A

JUNE 19, 23

ISSUED FOR CONSTRUCTION

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

(50' R/W)

DAVID CORTS, SR.

DAVID CORTS, JR.

ERNEST T. BROWN

ReD

HEINZ CARRINGTON

MARTHA PENELOPE

EXISTING BRICK HEADWALL

TO BE REMOVED

REMOVE EXISTING TREE

REMOVE 22 LF OF

DETERIORATED 18" CMP

TEMPORARY

CONSTRUCTION

EASEMENT

PERMANENT

DRAINAGE

EASEMENT

CAUTION: OVERHEAD

ELECTRIC CABLES

REMOVE APPROXIMATELY

85 LF OF EXISTING

CONCRETE CURB

EX. STONE CURB

EX. CONCRETE HEADER CURB

X EL. 837.25

X EL. 836.98

X EL. 836.87

X EL. 836.75

X EL. 836.49

X EL. 836.19

X EL. 836.11

X EL. 836.06 X EL. 836.00

X EL. 835.93 X EL. 835.90

X EL. 835.58

SLOPE 1.9%

SLOPE 1.9%

SLOPE 0.55%

SLOPE 0.5%

SLOPE 2.1%

S

T

A

T

E

S

T

R

E

A

M

B

U

F

F

E

R

S

T

R

E

T

U

R

U

N

D

A

R

Y

S

T

R

E

T

U

R

U

N

D

A

R

Y

S

T

A

T

E

S

T

R

E

A

M

B

U

F

F

E

R

EXISTING REINFORCED

CONCRETE HEADWALL

WITH ENERGY DISSIPATERS

EXISTING TYPE 1

RIP RAP 3 FEET DEEP.

EXISTING CONDITIONS & DEMO PLAN

EXISTING CONDITIONS & DEMO PLAN

Scale: 1"= 10'

THE CITY OF SANDY SPRINGS

DEPARTMENT OF PUBLIC WORKS

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

3 OF18

Project Location:1025-1075 Crest Valley Drive

X

X

X

X

X

X

X

X

Know what's below.

before you dig.Call Dial 811

Or Call 800-282-7411

NOTES:

1. THE TEMPORARY CONSTRUCTION EASEMENT IS THE STAGING AREA. CUT

THE TREES IN THIS AREA AND FILL WITH SOIL MATERIAL TO MAKE IT

USABLE FOR MACHINARY AND CONSTRUCTION MATERIAL STORAGE.

THE SIDE SLOPES TO BE 3:1.

2. FOR EASEMENT DIMENSIONS SEE PLATS OF EASEMENT ON SHEET 15.

3. SURVEY PREPARED BY GEOSURVEY LAND SURVEYORS DATE 6/2/2020.

HEADWALLS AND STORM SEWER UPDATED SOUTH OF THE STREET

CENTERLINE BY NEELU INC.

4. GUTTER ELEVATIONS NORTH SIDE OF THE STREET ADDED BY NEELU INC.

X

X

X

X

X

(SEE NOTE 2)

(SEE NOTE 2)

SEE NOTE 1

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

CAUTION: OVERHEAD

ELECTRIC CABLES

REMOVE:

ONE 8" POPLAR TREE

ONE 15" POPLAR TREE

ONE 5" BEECH TREE

ONE 4" BEECH TREE

ONE 38" PINE TREE

ONE CLUSTER HARDWOOD TREE

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A ISSUED FOR CONSTRUCTION

JULY 05, 23

X

X

X

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

JB

(50' R/W)

DAVID CORTS, SR.

DAVID CORTS, JR.

ERNEST T. BROWN

HEINZ CARRINGTON

MARTHA PENELOPE

PROPOSED RIP RAP

PROPOSED 84" REINFORCED

CONCRETE HEADWALL

22 LF OF 18" DETERIORATED CMP

TO BE REPLACED WITH 18" RCP

P

R

O

C

P

THE ENTIRE LENGTH OF THE 84"

CULVERT WILL BE REHABILITATED

TEMPORARY

CONSTRUCTION

EASEMENT

PERMANENT

DRAINAGE

EASEMENT

MODIFY 4' INSIDE DIA. JB FOR

NEW 18" RCP PENETRATION

PROPOSED 22 LF

OF 18" RCP

EX. STONE CURB

110 LF OF DETERIORATED 6"

CONCRETE HEADER CURB

(TYPE 2) TO BE REPLACED

SEE SHEET 10 FOR DETAIL

S

T

A

T

E

S

T

R

E

A

M

B

U

F

F

E

R

S

T

R

E

T

U

R

U

N

D

A

R

Y

S

T

R

E

T

U

R

U

N

D

A

R

Y

S

T

A

T

E

S

T

R

E

A

M

B

U

F

F

E

R

EXISTING REINFORCED

CONCRETE HEADWALL

WITH ENERGY DISSIPATERS

EXISTING TYPE 1

RIP RAP 3 FEET DEEP.

PROPOSED IMPROVEMENTS PLAN

PROPOSED IMPROVEMENTS PLAN

Scale: 1"= 10'

Know what's below.

before you dig.Call Dial 811

Or Call 800-282-7411

THE CITY OF SANDY SPRINGS

DEPARTMENT OF PUBLIC WORKS

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

4 OF18

Project Location:1025-1075 Crest Valley Drive

STREAMBANK RIP RAP

H=3' @ 1.5:1 SLOPE

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A ISSUED FOR CONSTRUCTION

JULY 05, 23

B K.A ISSUED FOR CONSTRUCTION

JULY 20, 23

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

THE CITY OF SANDY SPRINGS

DEPARTMENT OF PUBLIC WORKS

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

5 OF18

Project Location:1025-1075 Crest Valley Drive

THIS IMAGE SHOWS AN EXAMPLE OF A CMP WITH REINFORCED

90°

50°

GROUT PORTS @ 6' SPACING (TYP)

@ 5, 7 O'CLOCK CIRCUMFERENTIAL POSITIONS

FILL VOIDS UNDER THE CULVERT

WITH SLURRY CEMENT BACKFILL

4" CONCRETE INVERT PAVING

(FROM TOP OF CORRUGATIONS)

2"

84" CMP CULVERT PIPE LINING DETAIL REHABILITATION

1. DIVERT STREAM RUNOFF AND DEWATER THE UPSTREAM

HEADWALL AREA.

2. REMOVE THE RUST AND COATING FROM THE 84" CMP

INVERT PAVING AREA AND CLEAN.

3. USE CHEMICAL EXPANSION GROUT TO FILL VOIDS OUTSIDE OF THE PIPE.

4. THE FOLLOWING JOINTS NEED REPAIR AND EXPANSION RINGS:

THE JOINTS AT 21', 41', AND 62' FROM THE DOWNSTREAM END.

5. SEAL JOINTS USING STEEL EXPANSION RINGS AND RUBBER

GASKETS AT THE REPAIRED JOINTS.

6. INSTALL STUDS, TACK WELD WIRE FABRIC AND PLACE CONCRETE.

SLO

PE 5

:1

CONCRETE LINING

#10 WELDED WIRE FABRIC 6"X6"

TACK WELD TO METAL STUDS

TRANSVERSELY AND 24" LONGITUDINALLY

METAL STUDS

1/2" DIA. 2-1/2" LONG METAL STUDS WELDED

TO CREST OF CORRUGATION @24"

CULVERT REHABILITATION

EXISTING 84" CORRUGATED

METAL PIPE CULVERT

CORRUGATION SPACING: 5"

CORRUGATION DEPTH: 1"

SLO

PE 5:1

A A

2'-0"

SECTION A-A

INTERNAL EXPANDING TYPE COUPLING BAND WITH GASKETS AND SEALING MATERIAL

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A

JUNE 19, 23

ISSUED FOR CONSTRUCTION

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

6 OF18

Project Location:1025-1075 Crest Valley Drive

Storm Sewer Tabulation

Stormwater Studio 2023 v 3.0.0.31

Project Name: 1025 Crest Valley Drive.

04-27-2023

Line

ID

(ft )

22 LF 18" RCP

Drng Area

Incr Total

(ac ) (ac ) (C )

22.00 0.000 2.200 0.00 0.00 1.43

C x A

Incr Total

Tc

Inlet Syst

(min )

0.0

Line

(in/hr ) (cfs ) (ft/s )

5.94 8.74 13.59 35.40 10.84

Size Slope

(in )

Invert Elev

Up

11.36 828.50

Dn

826.00

HGL Elev

Up

829.81

Dn

826.77

Surface Elev

Up

836.54

Dn

830.0 1

Line

No

Notes: IDF File = AlpharettaGA (1).idf, Return Period = 25-yrs. Total Qs limited to inlet captured flows.

Project File: Crest Valley Storm Sewer Model 4-27-23.sws

L e n g t h

R a t i o n a l

I n t e n s i t y

T o t a l

Q

C a p a c i t y

V e l o c i t y

18" STORM SEWER PIPE PROFILE

18" STORM SEWER PIPE PROFILE

TRENCH DETAIL

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

PR

O

PO

SE

D

HE

AD

W

AL

L

REMOVE EXISTING 18" CMP AND REPLACE WITH 18" RCP

P

R

O

P

O

S

E

D

G

O

U

N

D

E

X

G

R

O

U

N

D

25-YR HGI

22Lf- 18"@

11.3 6%

825.00

827.00

829.00

831.00

833.00

835.00

837.00

839.00

841.00

10 15 20 25 30 823.00

843.00

845.00

847.00

Grnd Surface

LINE 1- 22FL 18" RCP

St a

0+

O ut fa ll

EX

. G rn d.

E l.

9.

In v.

E l.

6.

HG

L

6.

St a

0+

Li ne :1

In v.

E l.

8.

In

HG

L

9.

O ut

Ri m

. E l.

6.

In v.

E l.

8.

O ut

HG

L

9.

In

HGL

-10

825.00

827.00

829.00

831.00

833.00

835.00

837.00

823.00

-20

821.00

819.00

817.00825.00

827.00

829.00

831.00

833.00

835.00

837.00

839.00

841.00

823.00

843.00

845.00

847.00

825.00

827.00

829.00

831.00

833.00

835.00

837.00

823.00

821.00

819.00

817.00 0 10 20 30 40 50 60 70 80 90 100

EL. 819.0

EL. 823.1

EL. 832.11

EL. 828.0

839.00 839.00

EL. 836.6

Y

R

H

G

L

P

I

E

I N

I N

G

EX. 84" CORRUGATED METAL

PIPE CULVERT

EX

. R

EI

N

F.

C

O

C.

HE

AD

W

AL

L

EX

. G

AS

P

IP

E

EX

. S

AN

W

AT

ER

M

AI

N PROP. SLOPE

18" STORM SEWER PIPE

EX

. C

G

EX

. C

G

EX. PAVEMENT

SE

W

ER

EX

. J

U N

CT

IO

N B

O X

84" CORRUGATED METAL PIPE CULVERT PROFILE

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A

JUNE 19, 23

ISSUED FOR CONSTRUCTION

MODIFY EX. JB FOR NEW 18" DIA.

RC PIPE PENETRATION

EL. 832.1 PR

O

P.

EL

. 8

.0

EX

IS

TI

N

G

JU

N

CT

IO

N

B O

X

PP

RO

PO

SE

D

HE

AD

W

AL

L

6.0'

82.0'

6.0'

SCALE: 1in = 2.5 ft H, 1in = 5 ft V

SCALE: 1in = 15 ft H, 1in = 5 ft V

84" CMP CULVERT TABULATION ( 100-YR RETURN PERIOD PIPE CHART)

Discharge Velocity Depth HGL @ Hw/D = 0.88

Invert

Total Culvert

Over Top

Down

Up

Down

Up

Down

Up

Down

Up

Hw

(cfs ) (cfs ) (ft/s ) (in )

257.60 257.60 0.00 16.29 10.60 36.1 50.7 822.01 826.83 828.77 828.00 832.10

(min ) (cfs ) (ft ) (ft ) (ft ) (ft ) (ft ) (ft )

(cfs ) (ft/s ) (in ) (ft/s ) (ft/s ) (ft/s ) (ft/s ) (ft/s )

NOTE: THE ACTUAL DOWNSTREAM VELOCITY IS BELOW 15 FT/S DUE TO THE ENERGY DISSIPATERS.

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

B B

C

C

Scale: 1"=2'

BEDDING STONE

Scale: 1"=2'

THE CITY OF SANDY SPRINGS

DEPARTMENT OF PUBLIC WORKS

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA Project Location:1025-1075 Crest Valley Drive

HEADWALL DESIGN

Scale: 1"=2'

0'-8"

5'-4"

0'-10" 5'-2"

17'-0"

INVERT LINING

1'-0"

7'-5" 2'-6"

1'-0"

DRAWING NO.

7 OF18

HEADWALL CONSTRUCTION NOTES:

1. CONTRACTOR SHALL CONTACT "GEORGIA 811" PRIOR TO STARTING ANY EXCAVATION.

2. CONTRACTOR SHALL VERIFY ANY CONFLICTS WITH EXISTING UTILITIES. IF A CONFLICT IS

ENCOUNTERED, CONTRACTOR SHALL NOTIFY ENGINEER AND CITY OF SANDY SPRINGS AND A

RESOLUTION SHALL BE REACHED BEFORE WORK PROCEEDS IN THE AFFECTED AREA.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE AND MAINTAIN ANY AND ALL WORK

NECESSARY TO PROTECT EXISTING UTILITIES (INCLUDING PIPELINES, POWER, AND COMMUNICATION

LINES) IN THE PROJECT VICINITY. ANY DAMAGE TO EXISTING UTILITIES SHALL BE REPAIRED TO THE

SATISFACTION OF THE ENGINEER AND CITY OF SANDY SPRINGS AT THE SOLE EXPENSE OF THE

CONTRACTOR AND/OR HIS SUB-CONTRACTORS.

4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE AND MAINTAIN ANY AND ALL WORK

NECESSARY TO PROTECT EXISTING FACILITIES (THIS INCLUDES PAVEMENT, SIDEWALKS, DRAINAGE

STRUCTURES, TREES, AND PLANTED AREAS). ANY DAMAGE TO EXISTING FACILITIES SHALL BE

REPAIRED TO THE SATISFACTION OF THE OWNER AT THE SOLE EXPENSE OF THE CONTRACTOR AND/OR

HIS SUB-CONTRACTORS.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND ERECTION OF ALL NECESSARY

FORM-WORK, TEMPORARY BRACING, AND SHORING REQUIRED DURING EXCAVATION OF SOIL

ADJACENT TO EXISTING STRUCTURES AND FACILITIES.

6. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND GRADE CONDITIONS (BOTH NEW

AND EXISTING), REPORTING ANY DISCREPANCIES TO THE ENGINEER PRIOR TO ORDERING MATERIALS

OR PROCEEDING WITH ANY PHASE OF THE WORK.

7. REFER TO CIVIL DRAWINGS FOR BEDDING BELOW THE HEADWALL.

8. CONTRACTOR SHALL CONTROL SITE GROUNDWATER AND/OR SURFACE WATER BY ALL MEANS

NECESSARY TO MAINTAIN A WATER LEVEL A MINIMUM 1 FEET BELOW FOUNDATION SUB-GRADE SO AS

TO NOT DAMAGE FOUNDATION EXCAVATIONS. THE BASE OF ALL FOUNDATION EXCAVATIONS SHOULD

BE FREE OF ALL WATER AND LOOSE SOIL PRIOR TO PLACING CONCRETE. ANY SUB-GRADE SOILS WHICH

HAVE BEEN WEAKENED DUE TO SATURATION OR DISTURBANCE SHALL BE RE-COMPACTED OR

REMOVED AND REPLACED WITH STRUCTURAL FILL AS DIRECTED BY THE PROJECT ENGINEER.

9. LOOSE OR SOFT SOILS SHALL BE CLEANED FROM FOUNDATION EXCAVATION BOTTOMS PRIOR TO

PLACING OF CONCRETE. SUB-GRADES NEEDING UNDERCUTTING SHALL BE BACKFILLED TO THE

ORIGINAL SUB-GRADE ELEVATION WITH COMPACTED FILL MATERIAL UNLESS DIRECTED OTHERWISE BY

THE ENGINEER. THE OVER-EXCAVATED AREA SHALL EXTEND A MINIMUM OF 1 FOOT BEYOND THE

EDGES OF THE STRUCTURE BASE SLAB OR FOOTING.

10. CONCRETE SLAB SHOULD BE PLACED AS SOON AS POSSIBLE AFTER EXCAVATIONS ARE MADE. IF THE

BEARING SOILS ARE SOFTENED BY SURFACE WATER INTRUSION OR EXPOSURE, THEN THE SOFTENED

SOILS MUST BE REMOVED FROM THE FOUNDATION EXCAVATION BOTTOM IMMEDIATELY PRIOR TO

PLACING OF CONCRETE. IF THE EXCAVATION MUST REMAIN OPEN OVERNIGHT, OR IF RAINFALL IS

IMMINENT WHILE THE BEARING SOILS ARE EXPOSED, THEN A 2- TO 3-INCH-THICK LAYER OF LEAN

CONCRETE (500 PSI MINIMUM STRENGTH) SHALL BE PLACED ON THE BEARING SOILS BEFORE THE

PLACEMENT OF REINFORCING STEEL. THE SUB-GRADE SHALL BE EXCAVATED AS REQUIRED TO

ACCEPT THE LEAN CONCRETE SO THAT THE INTENDED BOTTOM OF FOUNDATION ELEVATION IS NOT

CHANGED.

11. THE HEADWALL SLAB SHALL BE PLACED IN ONE CAST, NO HORIZONTAL JOINTS ARE PERMITTED.

12. ALL EXCAVATIONS SHALL CONFORM TO APPLICABLE OSHA REGULATIONS.

13. UNLESS NOTED OTHERWISE, ALL CONCRETE WORK, DETAILING, FABRICATION, AND PLACING OF

REINFORCING AND CONCRETE FOR THE HEADWALL STRUCTURE SHALL BE GOVERNED BY THE LATEST

REVISIONS OF: · ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE". · ACI 306 AND ACI 305 FOR

COLD AND HOT WEATHER CONCRETING. · ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL

CONCRETE. · CRSI RECOMMENDED PRACTICE OF PLACING REINFORCING BARS.

14. ALL CONCRETE WORK SHALL MEET GDOT STANDARD SPECIFICATION SECTION 500 EXCEPT WHERE

NOTED OTHERWISE ON THE CONSTRUCTION DRAWINGS. IF A CONFLICT EXISTS BETWEEN THE

DRAWINGS AND GDOT SPECIFICATIONS, THE MORE STRINGENT SHALL APPLY.

15. ALL CONCRETE SHALL BE NORMAL WEIGHT GDOT CLASS A AIR-ENTRAINED WITH A MAXIMUM UNIT

WEIGHT OF 150 POUNDS PER CUBIC FOOT AND SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE

STRENGTH OF 3,000 PSI.

16. PROVIDE A 3/4" CHAMFER AT ALL EXPOSED CONCRETE CORNERS.

17. UNLESS NOTED OTHERWISE, REINFORCING STEEL SHALL CONFORM TO ASTM A 615, AND SHALL BE

GRADE 60.

18. CULVERT REINFORCING LAP SPLICES SHALL BE PER GDOT STANDARD 2324. REINFORCING BAR HOOK

DIMENSIONS, AND ALL OTHER REINFORCING BAR LAP SPLICES SHALL BE CLASS "B" TENSION LAPS AND

SHALL BE AS REQUIRED PER THE SCHEDULE ON CULVERT DRAWING.

19. UNLESS OTHERWISE NOTED ON THE DRAWINGS, THE FOLLOWING CONCRETE COVER SHALL BE

PROVIDED OVER REINFORCEMENT: · CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO

EARTH: 2” · ALL OTHER CONCRETE: 1.5”

1'-0"

EL. 823.1

D

D

11'-2"

17'-0"

2'-6"1'-0"

13'-0"

EX. 84" CMP

REINF. CONC.

PIPE LINING

89" OPENING

2'-6" OPENING

FOR 18" RCP

EL. 823.1

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

EL. 832.1

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A

JUNE 19, 23

ISSUED FOR CONSTRUCTION

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

REINFORCEMENT

C

L

1'-6"

8"

1'-6" MIN. LAP ABOVE

CONSTR. JT. (BASIC REINF.)

RAKED CONSTR. JT.

2" CL.

NO. 4 BARS

12" C. TO C.

BOTH WINGS

ADDITIONAL BARS 45"

ABOVE SLAB & IN

BOTTOM SLAB

POS.

Scale: N.T.S.

Scale: N.T.S.

Scale: N.T.S.

NO. 4 BARS

12" C. TO C.

BOTH FACES

NO. 4 BARS

12" C. TO C.

BOTH FACES

POS.

POS.

NO. 4 BARS 12" C.

TO C. BOTH FACES

BOTH WINGS

A

A

BB

NO. 4 BARS

12" C. TO C.

BOTH FACES

POS.

Scale: N.T.S.

NO. 4 BARS

8" C. TO C.

BOTH FACES

2" CL.

POS.

NO. 4 BARS

8" C. TO C.

BOTH FACES

POS.

2" CL.

NO. 4 BARS

12" C. TO C.

BOTH FACES

NO. 4 BARS

12" C. TO C.

BOTH FACES

POS.

2" CL.

B B

NO. 4 BARS 12" C. TO C. BOTH FACES

BOTH WINGS

2- NO. 4 BARS 12" C. TO C.

BOTH FACES POS.

POS.

2- NO. 4 BARS 12" C. TO C.

BOTH FACES

POS.

NO. 4 BARS

BOTH FACES

POS.

NO. 4 BARS

12" C. TO C.

BOTH FACES

POS.

NO. 4 BARS

12" C. TO C.

BOTH FACES

POS.

NO. 4 BARS 12" C. TO C.

BOTH FACES

POS.

NO. 4 BARS

12" C. TO C.

BOTH FACES

POS.

THE CITY OF SANDY SPRINGS

DEPARTMENT OF PUBLIC WORKS

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

8 OF18

Project Location:1025-1075 Crest Valley Drive

HEADWALL DESIGN FORMWORK &

REINFORCEMENT

2- NO. 4 BARS 12" C. TO C.

BOTH FACES

NO. 4 BARS 12" C. TO C.

BOTH FACES

NO. 4 BARS 12" C. TO C.

BOTH FACES

C C

EL. 823.1

NO. 4 BARS

12" C. TO C.

BOTH FACES

POS.

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

0'-8"

0'-10"

13'-0"

POS.

ADDITIONAL NO. 4

BARS BOTH FACE

NO.4 BARS

BOTH FACES

POS.

POS.

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A

JUNE 19, 23

ISSUED FOR CONSTRUCTION

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

9 OF18

Project Location:1025-1075 Crest Valley Drive

CONSTRUCT STONE VENEER FACING ON 84" HEADWALL. STONE VENEER

TO BE ATTACHED TO THE HEADWALL USING BRICK TIES AT 24"X24".

SEE MANUFACTURER SPECIFICATIONS

Note: Dimensions and quantities are for information only.

The contractor must take measurements after formwork is completed.

d b

90° BEND

SECTION

CRITICAL

LDH

180° HOOK

LDH

R

4db

(2-1/2" MIN.

LD

STANDARD

CLASS "B"

LAP AND

TOP BAR LAP

TOP BAR - DEFINED AS A BAR

LOCATE SUCH THAT 12 IN. OR

MORE OF FRESH CONCRETE IS CAST

IN THE MEMBER BELOW THE SPLICE

MINIMUM OUTSIDE RADIUS OF BEND,

R, SHALL BE 4db

LD - STANDARD DEVELOPMENT LENGTH OF BAR

LDH - STANDARD DEVELOPMENT LENGTH OF HOOK

F'c - SPECIFIED COMPRESSIVE STRENGTH OF CONCRTE db - BAR DIAMETER PER ASTM

REBAR SPLICE AND HOOK

DIMENSIONS IN REIINF. CONCRETE

F'c =4.500 PSI

NOTES :

ASTM

BAR

SIZE

LD

CLASS

B

LAP

TOP

BAR

LAP

LDH

12"

12"

17"

14"

12"

14"

21"

18"

14"

19"

28"

23"

7"

9"

28"

23"

SEE SPLICE SCHEDULE

HORIZ. BARS

VERT. BARS

NO. 4 BARS

"U" BARS AT ENDS OF

WALLS, MATCH SIZE AND

SPACING OF HORIZ. WALL RINFORCING

12db 12db

12db

SEE PLAN

S E

E

P

L A

N

TYP.

WALL ANGLE

WALL ANGLE

90° STD. HOOK

TYPICAL

NO. 4 BAR

FOR WALL CORNERS WHERE

" WALL ANGLE " IS GREATER THAN

120° BUT LESS THAN 180°

FOR WALL CORNERS WHERE

" WALL ANGLE " IS GREATER THAN

60° BUT LESS THAN 120°

NO. 4 BAR

NO. 4 BAR

Corner reinforcement and U-bars not included.

HEADWALL DETAILS AND BAR SCHEDULE

POS. SIZE SHAPE QTY.

Length

TOTAL LENGTH

REINFORCEMENT MTO

TOTAL LENGTH ( ft )

UNIT WEIGHT ( lbs/ft )

TOTAL WEIGHT BY SIZE ( lbs )

#1

#4

#2 #3 #4 #5 #6

#4

#4

#4

#4

#4

#4

#4

#4

#4

5'-2"

5" 5"

13' ~ 17'

5" 5"

9'-8"

4" 4"

12'-8"

4" 4"

16'-8"

5" 5"

2'-6"

5" 5"

3'-6" ~ 8'-6"

4" 4"

1'-8"

3'-6"

6'-2"

4"

6'-0"

4"

6' 17x2

7x2

2x2

8x2

4x2

204'

VAR. 224'

6'-10" 27'

10'-4"

160'

13'-4"

107'

3x2

105'

17'-6"

24x2

163'

7x2x2VAR.

4x2x26'-10"

177'

30x2

310'

3'-4"

5'-2"

110'

0.668

12 #4 1'-8" ~ 3'-0"

4" 4"

11x2VAR.

70'

13 #4 1' ~ 5'

5" 5"

6x2VAR.

44'

#4 1' ~ 8'-6"

4" 4"

6x2x2VAR.

220'

5"5"

14 #4

4'-4"

2x25'-2" 21'

5"5"

15 #4 4x23'-0" 24'

2'-2"

5"5"

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A

JUNE 19, 23

ISSUED FOR CONSTRUCTION

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

Rip-Rap Type and Installation

Rip-Rap slope will be used to stabilize the eroding stream banks. Rip-Rap installation shall be in accordance to GDOT section 805, Section 881, and

GSWCC 2016 Edition appendix C - Rip Rap.

· GDOT Section 805 - Rip Rap and Curbing Stone

· GSWCC 2016 Edition - Appendix C - Rip Rap

· GDOT Section 881 - Fabrics

1. Site preparation:

Streambanks shall be prepared for rip-rap installation by clearing any existing rocks and plants and creating a smooth sloped surface and compacted. The slope and location of final graded streambanks shall be according to the project construction drawings.

2. Geotextile Fabric

The geotextile fabric shall be placed over the graded and compacted sloped streambanks according to the detail provided on construction drawings. US

670 geotextile is recommended and meets the AASHTO M-288-06 requirements for Permanent Erosion Control & Subsurface Drainage.

3. Rip-Rap Stone

Type 3 rip-rap shall be used for streambanks protection. See GSWCC 2016

Edition, Appendix C, Table C-3 for Graded Rip-Rap Stone.

4. Rip-Rap Installation

Stones shall be placed from the base of the slope to the top in one operation.

The base of the rip-rap shall be a minimum of 1.5 feet below the stream natural grade. Placing of the rocks must not damage or disturb the geotextile fabric. The stones shall be placed by hand in an interlocking manner.

Dumping of rocks is not allowed. Riprap shall extend up the bank to an elevation where vegetation will provide adequate protection.

THE CITY OF SANDY SPRINGS

DEPARTMENT OF PUBLIC WORKS

1 GALAMBOS WAY

SANDY SPRINGS, GA 30328

PHONE: (770) 730 5600

SANDY SPRINGS

GEORGIA

Neelu, Inc.

601 Basset Ct., SE, Smyrna, GA 30080

Phone: (770) 312 2014

REVISIONS TABLE

Revision ByDate Description

REG I STEREDG E O R G I A

REENIGNE

RAM

ESH KA LVAKAALV

A

PROFESSIONAL

No. 26993 * *

SANDY SPRINGS

GEORGIA

DRAWING NO.

10 OF18

Project Location:1025-1075 Crest Valley Drive

DRAINAGE MAINTENANCE AND IMPROVEMENT PROJECT

0 K.A

JUNE 10, 23

ISSUED FOR COMMENT

A K.A ISSUED FOR CONSTRUCTION

STREAMBANK RIP RAP AND CURB AND

GUTTER DETAILS

JULY 05, 23

PERMITTED BY: _________________________________________ DATE: ______________________

PERMIT #: ___________________________________________________________________________

THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES

ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR

PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE

BUILDING CODES.

STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE

OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS

ORDINANCES AND GEORGIA STATE LAWS.

A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE

REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.

THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR

TO THE CONCEALMENT OF WORK.

PERMIT

APPROVED

SEDIMENT & EROSION CONTROL NOTES

AND TREE PROTECTION DETAIL

EROSION, SEDIMENTATION, AND POLLUTION CONTROL

NOTES

PRIOR TO LAND-DISTURBING ACTIVITIES, THE CONTRACTOR SHALL SCHEDULE A

PRE-CONSTRUCTION MEETING WITH THE AREA EROSION CONTROL INSPECTOR.

THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE

INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES

PRIOR TO LAND DISTURBING ACTIVITIES.

EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. IF FULL

IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE FOR EFFECTIVE

EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES

SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE.

ANY DISTURBED AREA LEFT EXPOSED FOR A PERIOD GREATER THAN 14 DAYS

SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING.

ALL DISTURBED AREAS LEFT MULCHED AFTER 30 DAYS SHALL BE STABILIZED WITH

PERMANENT VEGETATION.

EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSPECTED AT LEAST

WEEKLY, AFTER EACH RAIN, AND REPAIRED AS NECESSARY.

ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED IF

DETERMINED NECESSARY BY ON-SITE INSPECTION.

ALL SILT FENCES MUST BE TYPE C, WIRE BACKED, AND MEET THE REQUIREMENTS

OF SECTION 171-TEMPORARY SILT FENCE FOR THE GEORGIA DEPARTMENT OF

TRANSPORTATION, QUALIFIED PRODUCTS LIST #36.

ALL AMENDMENTS AND REVISIONS TO THE EROSION & SEDIMENT CONTROL PLANS

WHICH WILL HAVE A SIGNIFICANT EFFECT ON BEST MANAGEMENT PRACTICE (BMP)

WITH A HYDRAULIC COMPONENT MUST BE CERTIFIED BY THE DESIGN

PROFESSIONAL.

ALL TEMPORARY AND PERMANENT SEEDING MUST BE PERFORMED AT THE

APPROPRIATE SEASON. IN SUCH INSTANCES WHERE THE ESTABLISHMENT OF

VEGETATION IS INOPPORTUNE DUE TO SEASON OR DROUGHT, DISTURBED AREAS

SHALL BE TEMPORARILY STABILIZED USING 2”-4” OF MULCH (DS1). ADDITIONAL

PLANTINGS WILL BE NECESSARY IF A SUFFICIENT STAND OF GRASS FAILS TO GROW.

THE CITY'S DESIGNEE WILL VERIFY ADEQUATE VEGETATIVE COVER (100% COVER,

70% DENSITY) OF PERMANENT STABILIZATION (Ds3, Ds4).

SEDIMENT AND EROSION CONTROL MEASURES SHOULD BE CHECKED AFTER EACH

RAIN EVENT. EACH DEVICE IS TO BE MAINTAINED OR REPLACED IF SEDIMENT

ACCUMULATION HAS REACHED ONE HALF THE CAPACITY OF THE DEVICE.

CONTRACTOR SHALL INSPECT EROSION CONTROL MEASURES AT THE END OF EACH

WORKING DAY TO ENSURE MEASURES ARE FUNCTIONING PROPERLY.

FAILURE TO INSTALL, OPERATE, OR MAINTAIN ALL EROSION CONTROL MEASURES

WILL RESULT IN ALL CONSTRUCTION BEING STOPPED ON THE JOB UNTIL SUCH

MEASURES ARE CORRECTED BACK TO THE APPROVED EROSION CONTROL PLANS.

THE SITE CONTRACTOR WILL BE RESPONSIBLE FOR MAINTENANCE OF ALL EROSION

CONTROL MEASURES INCLUDING REPLACING OR REPAIRING ANY DAMAGED

DEVICES DUE TO ANY CONSTRUCTION ACTIVITY BY OTHERS.

DURING CONSTRUCTION, THE CONTRACTOR SHALL MAINTAIN CAREFUL

SCHEDULING AND PERFORMANCE TO ENSURE THAT LAND STRIPPED OF ITS

NATURAL GROUND COVER IS EXPOSED ONLY IN SMALL QUANTITIES AND

THEREFORE…