100_PERMIT_REV_1.pdf
PDF 5 MB Posted
- Attached to
- Expansion Joint Repair
- Solicitation number
- 25-CR-046
- Issued by
- Pinellas County, Florida
About this file
The document is a comprehensive structural engineering set of drawings and specifications for an expansion joint repair project at Dunedin High School in Pinellas County, Florida, prepared by Long & Associates Architects and Engineers, Inc. The project involves structural modifications to Building 9, specifically focusing on repairing and reinforcing an existing expansion joint. The drawings, dated December 18, 2024, are 100% permit documents that detail demolition plans, foundation modifications, floor and roof framing adjustments, and specific structural repair techniques. The design addresses structural damage observed on February 20, 2022, and includes detailed plans for carefully removing and replacing portions of existing concrete slabs, columns, and roof structures.
The project is designed in compliance with the 2023 Florida Building Code, 8th Edition, and follows strict structural engineering standards. The structural design accounts for specific wind load requirements, with a basic wind speed of 153 MPH (ultimate) and 119 MPH (equivalent nominal), and is classified as a Building Risk Category III. The documents specify precise technical requirements for concrete repairs, steel modifications, anchoring techniques, and expansion joint installations, including detailed specifications for materials like concrete strength (4,000 PSI), reinforcing steel, and specialized repair mortars. The project appears to be funded through the Pinellas County School Board and will require a Florida licensed General Contractor to execute the work according to the provided architectural and engineering specifications.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EB 1828
ARCHITECTURE/ENGINEERING:
813/839-0506
AR0015104
LONG & ASSOCIATES
TAMPA, FLORIDA 33611
4525 S. MANHATTAN AVE.
ARCHITECTS / ENGINEERS, INC.
INDEX OF DRAWINGS
TO THE BEST OF THE ARCHITECT'S
AND/OR ENGINEER'S KNOWLEDGE
THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODES AND THE
APPLICABLE FIRE-SAFETY STANDARDS
DIGITAL SEALS
Se al
EL
ME
R R . C
HA
SE
, P .E.
PE
L&A PROJECT NO.
Date:
Phase:
Drawn By:
Checked By:
Job No:
1/6/2025 11:46:02 AM
1/6/2025 11:46:02 AM
0%
PE
RM
IT
DO
CU
M
EN
T
DE
CE
MB
ER
, 2
100% PERMIT DOCUMENT DECEMBER 18, 2024
DUNEDIN HIGH SCHOOL
EXPANSION JOINT
PI
NE
LL
AS
C O
UN
TY
SC
HO
O
LS
P
IN
EH
UR
ST
R
D.
DU
NE
DI
N, FL
1651 PINEHURST RD.
DUNEDIN, FL 34698
23008
G0.1
L&A
ERC
100% PERMIT DOCUMENT
23008
DECEMBER 18, 2024
COVER SHEET
STRUCTURAL INDEX - ERC
ELMER R. CHASE, STATE OF FLORIDA, PROFESSIONAL ENGINEER,
LICENSE NO. PE 43895 IS RESPONSIBLE FOR ALL SHEETS APPEARING
ON THE COVER SHEET UNDER THE STRUCTURAL HEADING
G0.1 COVER SHEET
G0.2 ABBREVIATIONS, SYMBOL LEGEND, & MATERIALS LEGEND
SD1.1 EXISTING FOUNDATION & SLAB DEMOLITION PLAN
SD2.1 EXISTING 2ND FLOOR FRAMING DEMOLITION PLAN
SD3.1 EXISTING ROOF FRAMING DEMOLITION PLAN
SX1.1 EXISTING PHOTOS
SX1.2 EXISTING PHOTOS
S0.1 STRUCTURAL NOTES
S1.1 FOUNDATION & SLAB PLAN
S2.1 2ND FLOOR FRAMING PLAN AND SECTIONS
S3.1 ROOF FRAMING PLAN AND SECTIONS
S4.1 SECTIONS & DETAILS
REGIONAL MAP
LOCAL MAP
PROJECT LOCATION
PROJECT LOCATION
AT BLDG 6 & BLDG 9
EXPANSION JOINT
NO. DATE ISSUES & REVISIONS
1 03-17-23 60% CDs 2 04-26-2023 100% CD's
3 12-18-2024 100% PERMIT DOCUMENTS
4 01-03-2025 REV #1
El m er R
. C ha se , S ta te o f
Flo rid a, P ro fe ss io na l E ng in ee r, Lic en se N o.
P
E
Th is
Ite m h as b ee n di gi ta lly sig ne d an d se al ed b y
El m er R
. C ha se , P
E, on us in g a
D ig ita l S ig na tu re
Pr in te d co pi es o f t hi s d oc um en t a re n ot co ns id er ed si gn ed a nd se al ed a nd th e sig na tu re m us t b e ve rif ie d on a ny el ec tro ni c co pi es
/0
6/
CMU WALL, THICKNESS VARIES
STUD WALL, THICKNESS VARIES
EXISTING WALL TO REMAIN
RIGID INSULATION
CAVITY INSULATION
INSULATION (BATT, BLANKET, OR FILL)
PLYWOOD (SMALL SECTION)
PLYWOOD (LARGE SECTION)
STEEL (LARGE SECTION)
ROUGH LUMBER (CONTINUOUS)
ROUGH LUMBER (INTERMITTENT)
CONCRETE
COMPACTED FILL OR EARTH
FINISHED GRADE
NOTE: EXISTING BUILDING WALLS,
DOORS, FIXTURES, EQUIPMENT, ETC.
ARE GENERALLY SHOWN LIGHTER &
WITHOUT MATERIAL HATCHING
INTERIOR ELEVATION1A99.9.9
REVISION TAG
NOTE TAG1
0 COLUMN CENTERLINE
A101
A101
DETAIL
SECTION
A101
EXTERIOR ELEVATION
FINISHED FLOOR ELEVATIONFFE
135' - 5 1/2"
FINISHED FLOOR ELEVATION
AFF
9' - 0"
TO/FROM THE CENTER LINE OF
TO/FROM COLUMN CENTER LINES
NEW WALL CONSTRUCTION
TO/FROM THE FINISHED FACE OF
NEW WALL CONSTRUCTION
ALIGN NEW PARTITION TO EXIST (VERIFY EXIST
PARTITION CONSTRUCTION MATCHES NEW
PARTITION CONSTRUCTION)
STATEMENT:
PRODUCT APPROVAL SCHEDULE
STRUCTURAL
#ESR-3814HILTI
HILTI
ROOFING PRODUCTS
LEGACY REPORTS #EXPIRATION DATENOA #DESCRIPTIONMANUFACTURERPRODUCT
COMPLY WITH PRODUCT APPROVAL REQUIREMENTS OF CHAPTER 9N-3 OF THE FLORIDA ADMINISTRATIVE CODE. THE CONSTRUCTION MANAGER SHALL FOR EACH PRODUCT INSTALLED IN THE BUILDING ENVELOPE, PROVIDE THE APPLICABLE PRODUCT APPROVAL NUMBERS TO L&A THROUGH THE SUBMITTAL PROCESS AS SPECIFIED. ALL PRODUCTS INSTALLED SHALL CONFORM TO THE FLORIDA BUILDING CODE 8TH EDITION (2023) FOR THE WIND LOADS SHOWN IN THE STRUCTURAL DOCUMENTS. THE LIST OF BUILDING COMPONENTS FOR REQUIRED PRODUCTS AND MANUFACTURERS ARE AS FOLLOWS: ANY SUBSTITUTIONS OF THESE PRODUCTS LISTED WILL ONLY BE REVIEWED IF SPECIFIC
PRODUCT APPROVAL NUMBERS AND DATA IS SUBMITTED
COMPONENTS
MODIFIED BITUMEN
#ESR-4561
ITW BUILDEX TAPCON ANCHORS (UNCRACKED MASONRY)
HILTI HIT RE 500 V3 EPOXY W/ HAS-E-55 RODS
(CRACKED OR UNCRACKED CONCRETE)
HILTI KWIK BOLT TZ2 FASTENERS
(CRACKED OR UNCRACKED MASONRY)
FLORIDA
PRODUCT
#ESR-1671
#ESR-5334SIMPSON ET-3G ADHESIVE ANCHORS (CRACKED OR
UNCRACKED CONCRETE)
#ESR-4266HILTI HILTI KWIK BOLT TZ2 FASTENERS
(CRACKED OR UNCRACKED CONCRETE)
FPA# 15730.2
#ESR-2713SIMPSON TITEN HD SCREW ANCHORS (CRACKED OR
UNCRACKED CONCRETE) FPA# 15730.9
ITW BUILDEX TAPCON ANCHORS (UNCRACKED CONCRETE) #ESR-2202
SIMPSON TITEN HD SCREW ANCHORS
(UNCRACKED MASONRY)
SIMPSON #ESR-2138POWDER ACTUATED FASTENERS
(PAF'S) FPA# 15730.2
SIMPSON #ESR-3006 ; ER-326STRONG-DRIVE XL OR SELF-DRILLING X TEK
SCREWS
FPA# 15730.9
#16-1222.06
DESIGN CRITERIA:REFER TO WIND PRESSURE CHART ON STRUCTURAL DRAWINGS
1. COMPLY WITH THE FLORIDA BUILDING CODE, 8TH EDITION (2023)
2. ULTIMATE WIND SPEED - - 153 MPH
3. EQUIVALENT NOMINAL WIND SPEED - - 119 MPH
4. COMPONENTS TO BE IMPACTED RESISTANT
GENERAL PRODUCT APPROVAL NOTES
1. CONTRACTOR SHALL PROVIDE FULL INSTALLATION DETAILS OF THE ACTUAL
PRODUCT APPROVAL DOCUMENTATION ON SITE FOR INSPECTOR USE AS
REQUIRED.
2. FLORIDA PRODUCT APPROVAL (FPA#)
3. IN ACCORDANCE WITH THE FLORIDA PRODUCT APPROVAL SYSTEM,
MANUFACTURERS OF ROOFING, PANELS AND ALL STRUCTURAL COMPONENTS
THAT AFFECT THE STRUCTURAL INTEGRITY OF BUILDINGS DURING HURRICANES
MUST SUBMIT THE FOLLOWING DOCUMENTATION TO THE OFFICE OF LONG &
ASSOCIATES, ARCHITECTS AND ENGINEERS, INC. FOR REVIEW AND APPROVAL:
A. EVIDENCE THAT THE PRODUCT HAS BEEN EVALUATED FOR
COMPLIANCE WITH THE STANDARDS ESTABLISHED BY THE FLORIDA
BUILDING COMMISSION APPROVED ENTITY OR FLORIDA LICENSED P.E.
OR R.A.
B. EVIDENCE THAT THE MANUFACTURER HAS CONTRACTED WITH THE
FLORIDA BUILDING COMMISSION APPROVED QUALITY ASSURANCE
ENTITY TO MONITOR MANUFACTURING PRODUCTION AND HAS ACTIVELY
COMPLIED OR HAVE THE PRODUCT LISTED AND LABELED BY THE
COMMISSION APPROVED CERTIFICATION PROGRAM.
C. INSTALLATION INSTRUCTIONS CONSISTENT WITH THE EVALUATION OF
COMPLIANCE.
D. REFER TO STRUCTURAL DRAWINGS FOR DESIGN WIND PRESSURES
PER SQUARE FOOT (PSF).
GAF FL 5680-R36
#ESR-1056
Q
P
O
D
N
W
V
U
ABBREVIATIONS
L
K
J
I
A
T
S
MATERIALS LEGEND
X
Y
SYMBOL LEGEND
SYMBOL DESCRIPTION
C
B
F
E
G
H
M
R
DIMENSIONING CONVENTIONS
GENERAL NOTES
AREA
ANCHOR BOLT
AIR CONDITIONING
ALTERNATING CURRENT
A
AB
A/C
AC
ACCESS FLOOR
AMERICAN CONCRETE INSTITUTE
ACOUSTICAL
ACOUSTICAL CEILING TILE
AMERICANS WITH DISABILITIES ACT
ADDITIONAL
ADJUSTABLE
ADJACENT
ABOVE FINISHED COUNTER
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
AMERICAN INSTITUTE OF
AMERICAN INSTITUTE OF
ACOUSTICAL LINING
ALTERNATE
ALUMINUM
AMPERE
ANCHOR
ANODIZED
ACOUSTICAL PANEL
APARTMENT
APPROXIMATE
ACID RESISTANT
ARCHITECTURAL / ARCHITECT
ASBESTOS
AMERICAN SOCIETY OF
& AIR-CONDITIONING ENGINEERS
AMERICAN SOCIETY OF
ASPHALT
ASSOCIATION
AMERICAN SOCIETY FOR
AUTOMATIC
AUXILIARY
AVENUE
AMERICAN WOODWORKING INSTITUTE
ACFL
ACI
ACOUS
ACT
ADA
ADDNL
ADJ
ADJT
AFC
AFF
AHU
AIA
AISC
AL
ALT
ALUM
AMP
ANC
ANOD
AP
APT
APP
AR
ARCH
ASB
ASHRAE
ASME
ASPH
ASSOC
ASTM
AUTO
AUX
AVE
AWI
BULLETIN BOARD
BOARD
BOTTOM FACE
BITUMINOUS
BLOCK
BLOCKING
BUILDING
BACK
BENCH MARK
BEAM
BOTTOM
BASE PLATE
BEARING
BRITISH THERMAL UNIT
BRITISH THERMAL UNIT PER HOUR
BETWEEN
BASEMENT
BUILT UP ROOFING
BOTH WAYS
BB
BD
BF
BIT
BLDG
BLK
BLKG
BK
B/M
BM
BOT
BP
BRG
BSMT
BTU
BTUH
BTWN
BUR
BW
CABINET
CENTER TO CENTER
CEMENT
CUBIC FEET PER SECOND
CHANNEL
CONTROL JOINT
CENTER LINE
CEILING
CLEAR
CONSTRUCTION MANAGER
CONCRETE MASONRY UNIT
CLEAN OUT
COLUMN
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
COUPLING
CARPET
CARBON STEEL
CERAMIC TILE
CONDENSER UNIT
CUBIC YARD
CENTER
CERAMIC
CUBIC FEET
CUBIC FEET PER MINUTE
COMPUTER
COMPUTER PROCESSING UNIT
CONDUIT
CONCRETE
CORRIDOR
CAB
C/C
CEM
CER
CF
CFM
CFS
CH
CJ
CL
CLG
CLR
CM
CMU
CO
COL
COMP
CND
CONC
CONN
CONST
CONT
CONTR
CORR
CPLG
CPT
CPU
CS
CT
CTR
CU
CY
DEMOLITION
DENSITY
DETAIL
DIAMETER
DIAGONAL
DIFFUSER
DIMENSION
DISCONNECT
DOWN
DOOR
DOWNSPOUT
DRINKING FOUNTAIN
DITTO
DOUBLE
DEAD LOAD
DRAWING
STEEL CONSTRUCTION
ARCHITECTS
HEATING. REFRIGERATION
MECHANICAL ENGINEERS
TESTING & MATERIALS
DBL
DEM
DEN
DET
DF
DIA
DIAG
DIFF
DIM
DISC
DL
DO
DN
DR
DS
DWG
EACH
EXPANSION BOLT
EXHAUST FAN
EFFICIENCY
EXTRA HAZARD
ELEVATION
ELECTRIC / ELECTRICAL
EMERGENCY
ENERGY MANAGEMENT
ENCLOSURE
EXPLOSION PROOF
EQUAL
EQUIPMENT
ESTIMATE / ESTIMATED
EXISTING TO REMAIN
EVAPORATIVE / EVAPORATOR
EACH WAY
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
EXFILTRATION
EXHAUST
EXPANSION JOINT
EXPANSION
EXISTING RELOCATED
EXISTING
EXTERIOR
& CONTROL SYSTEM
MODULUS OF ELASTICITY
ENGINEER
ENGINEERING
E
EA
EB
EF
EFF
EH
EL
ELEC
EMERG
EMCS
ELEVATOR
ENCL
ENGR
ENGRG
EP
EQ
EQPT
EST
ETR
EVAP
EVTR
EW
EWC
EWH
EXF
EXH
EJ
EXP
EXR
EXST
EXT
FA
FACP
FBRK
FC
FD
FDC
FDN
FDPR
FE
FEC
FF
FFE
FFF
FG
FH
FHMS
FHS
FHWS
FIN
FJT
FL
FLG
FLSHG
FLR
FP
FPG
FPM
FPS
FO
FOC
FOF
FOM
FR
FRMG
FRTL
FS
FT
FTG
FURR
FV
FIRE ALARM
FIRE ALARM CONTROL PANEL
FIRE BRICK
FLEXIBLE CONNECTION
FLOOR DRAIN
FIRE DEPARTMENT CONNECTION
FOUNDATION
FIRE DAMPER
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISHED FLOOR
FINISHED FLOOR ELEVATION
FROM FINISHED FLOOR
FLANGED CONNECTION
FIRE HYDRANT
FLAT HEAD MACHINE SCREW
FIRE HOSE STATION
FLAT HEAD WOOD SCREW
FINISH / FINISHED
FLUSH JOINT
FLOOR
FLANGE
FLASHING
FLUORESCENT
FIRE PROTECTION
FIREPROOFING
FEET PER MINUTE
FEET PER SECOND
FLAT OVAL
FACE OF CONCRETE
FACE OF FINISH
FACE OF MASONRY
FRAME
FRAMING
FIRE RETARDANT TREATED LUMBER
FULL SIZE
FEET
FOOTING
FURRED / FURRING
FLUSH VALVE
FOS FACE OF STUD
FZR FREEZER
GA
GAL
GALV
GB
GC
GI
GL
GLBK
GP
GPM
GR
GRD
GRND
GS
GST
GWB
GYP
GAGE / GAUGE
GALLON
GALVANIZED
GRAB BAR
GENERAL CONTRACTOR
GALVANIZED IRON
GLASS / GLAZING
GLASS BLOCK
GENERAL PURPOSE
GALLONS PER MINUTE
GROOVED CONNECTION
GRADE
GROUND
GALVANIZED STEEL
GLAZED STRUCTURAL TILE
GYPSUM WALL BOARD
GYPSUM
HB
HC
HCP
HD
HDNR
HDW
HGR
HM
HORIZ
HP
HR
HRS
HSS
HT
HVAC
HZ
HOSE BIBB
HOLLOW CORE
HANDICAPPED
HARD
HARDENER
HARDWARE
HANGER
HOLLOW METAL
HORIZONTAL
HORSEPOWER
HOUR
HOURS
HOLLOW STRUCTURAL STEEL
HEIGHT
HEATING, VENTILATION,
HERTZ / CYCLES PER SECOND
I
IC
ID
IF
IN
INCL
INF
INFO
INSUL
INT
INV
MOMENT OF INERTIA
INTERCOM
INSIDE DIAMETER
INSIDE FACE
INCHES
INCLUDED
INFILTRATION
INFORMATION
INSULATION
INTERIOR
INVERT
IRON PIPEIP
AIR-CONDITIONING
AMOUNTAMT
LTWT LIGHTWEIGHT
MASONRY OPENING
NOISE REDUCTION
NOT IN CONTRACT
OUTSIDE DIAMETER
PLASTIC LAMINATE
POLYVINYL CHLORIDE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
POUNDS PER LINEAR FOOT
POUNDS PER CUBIC FOOT
PRESSURE TREATED
POST INDICATOR VALVE
QTY
QT
PA
QUARRY TILE
PUBLIC ADDRESS
QUANTITY
PLAM
PVC
PSF
PLF
PCF
PREFAB
PROJ
PRES
PVMT
PLYWD
PSI
PT
PIV
PREFABRICATED
PROJECTION
PRESSURE
PAVEMENT
PLYWOOD
OHD
OPP HD
PTD
PNLB
PNL
PLAS
PART
PR
OD
OH
PAINTED
PAIR
PANEL
PANELBOARD
PLASTER
PARTITION
OVERHEAD
OVERHEAD DOOR
OPPOSITE HAND
NAT
NRC
NTP
N/A
NEG
OPNG
NO
OC
NIC
NUMBER
OPENING
ON CENTER
NATURAL
NOTICE TO PROCEED
NOT APPLICABLE
NEGATIVE
MAXIMUMMAX
MULL
MOD
MOV
MISC
MIRR
MTL
MED
MECH
MM
MIL
MISCELLANEOUS
MULLION
MODEL
MOVABLE
MILLIMETER(S)
MILITARY
MIRROR
METAL
MEDIUM
MECHANICAL
MAT
MAS
MFR
MFD
MH
MO
MK
LL
LF
MANHOLE
MARK
MATERIAL
MASONRY
MANUFACTURER
MANUFACTURED
LIVE LOAD
LINEAR FOOT
VINYL TILEVT
VOLTS
VOLUME
VINYL WALL COVERING
WALL HUNG
WALL TO WALL
WALL CLEANOUT
WEATHER PROTECTED
WELDED WIRE FABRIC
WINDOW
WIDE FLANGE
WOOD
WITHOUT
WITH
WEIGHT
WATER CLOSET
WAINSCOT
WD
WWF
WIN
W/O
WF
W/
WT
WTW
WCO
WAINS
WH
WP
WC
VOL
VWC
V
UNLESS OTHERWISE NOTED
UTILITY
URINAL
UNDERCUT
UNDERGROUND
UNDERWRITER'S
VELOCITY
VARIABLE AIR VOLUME
VAPOR RETARDER
VERTICAL
VINYL COMPOSITION TILE
VINYL
VENT THRU ROOF
VACUUM
TRANSFER
TYPICAL
TRANSFORMER
TACK BOARD
URL
VPR
VAV
VEL
VERT
VCT
VTR
VIN
UTY
VAC
UON
UL
UG
UC
XFR
TYP
XFMR
TB
KILOVOLT AMPERE
KILOVOLTKV
KVA
LAM
LAB
LVG
LTG
LAV
KO
KIT
KW
LABORATORY
LIGHTING
LAVATORY
LEAVING
LAMINATE(D)
KNOCKOUT
KITCHEN
KILOWATT(S)
JT
JB
JST
JOINT
JUNCTION BOX
JOIST
SA SUPPLY AIR
SWITCH
SYMBOL
SYMMETRICAL
SYSTEM
SUSPEND(ED)
TELEVISION
TELEPHONE
THERMOSTAT
THICK(NESS)
TOILET
TONGUE AND GROOVE
TOP
THRESHOLD
TEMPERATURE
TOP OF MASONRY
TOP OF FOOTING
TOP OF CURB
TOP OF BEAM
TOP OF STEEL
TOP OF SLAB
TOP OF
TOP AND BOTTOM
TOP FACE
THK
T/
T/C
T/FTG
T/BM
T/MAS
T/STL
T/SLAB
TLT
T&G
TSHD
T&B
T/F
T
TEL
TSTAT
TEMP
TV
SYMB
SYM
SYS
SUSP
SW
SHEET
SOLID CORE
SPEAKER
SOUNDPROOF
STANDARD
SQUARE
SPRINKLER
STAINLESS STEEL
SQUARE FEET
STRUCTURAL CLAY TILE
SUPPLY
STEAM
STEEL JOIST
STORAGE
STEEL
STATION
SPECIFICATION(S)
SMOKE DETECTOR
SIMILAR
SAWCUT JOINT
SECONDARY
SECTION
SCHEDULE
SPKR
STA
SCT
SUP
STL JST
STM
STL
STOR
STD
SST
SPRK
SQ FT
SPEC
SQ
SHT
SNDP
SIM
SECT
SC
SD
SCH
SEC
SJ
JAN JANITOR
KNOCKDOWNKD
KILOGRAMKG
LBS
LVR
LS
POUNDS
LUMP SUM
LOUVER
LIN LINEAR
LH LEFT HAND
M BENDING MOMENT
MBF 1OOO BOARD FEET
MFG MANUFACTURING
MB MARKER BOARD
MEZZ MEZZANINE
MW MICROWAVE
MR MOISTURE RESISTANT
NEC NATIONAL ELECTRIC CODE
NOA NOTICE OF ACCEPTANCE
OPP OPPOSITE
OZ OUNCE
OF OUTSIDE FACE
OA OUTDOOR AIR
PCS PIECES
PLATEPL
PP POWER POLE
SMALLSM
SQUARE INCHSQ IN
SQUARE YARDSQ YD
STRUCTURALSTRUC
TOLERANCETOL
VINYL BASEVB
WIDE(WIDTH)W
YARDYD
COEFFICIENT
LABORATORY
W/
SOUND TRANSMISSION CLASSSTC
J JUNCTION
KIP / 1000 LBK
L LENGTH
LG LARGE
LO
LOC LOCATION
LOCKOUT
LT/GA LIGHT GAGE
LTH LIGHT HAZARD
LT LIGHT
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MC MEDICINE CABINET
MD MOTORIZED DAMPER
MIN MINIMUM
MTD MOUNTED
MT METAL THRESHOLD
MP MIDPOINT
ML METAL LATH
MS MOP SINK
MTR METER
NFA NET FREE AREA
NTS NOT TO SCALE
O ROUND
OAI OUTDOOR AIR INTAKE
ORDINARY HAZARDODH
OJ OPEN WEB JOIST
PC PHOTOCELL
PRECAST CONCRETEPCC
PHASEPH
PREFORMED JOINT FILLERPJF
PFD PREFORMED
POS POSITIVE
PRESTRESSED CONCRETEPSC
POST TENSIONED CONCRETEPTC
PWR POWER
PER UNITPU
PNT POINT
RIGHT
ROUGH OPENING
ROOF VENT
ROOFING
ROOM
RADIUS
RECIRCULATING
RECIPROCATING
REINFORCE(D),
REQUIRED
REVISION
RIGHT OF WAY
RETURN GRILLE
REVOLUTIONS PER MINUTE
RETURN
RETURN AIR
RELATIVE HUMIDITY
REGULAR
RECEIVER
RECEPTACLE
RT
RFG
ROW
RO
RV
RM
REQD
RPM
REV
RET
RG
RA
RH
RECIP
RECIRC
REINF
REG
RECPT
REC
RAD
REFRIGERATORREFG
REFERENCEREF
REINFORCING
RISER
REQUIREMENTREQT
REFLECTED CEILING PLANRCP
REDUCERED
ROOF DRAINRD
ROOF TOP UNITRTU
RAIN PROOFRP
RAIN WATER COLLECTORRWC
RAIN WATER LEADERRWL
S SANITARY
SQUARE FEETSF
SHEATHINGSHTG
STORM DRAINSDN
SQUARE YARDSY
SERVICESERV
TOP OF PIPET/P
TOP OF WALLT/W
TOP OF PLATET/PL
TOWEL RODTR
TRANSOMTRAN
TOILET PARTITIONTPTN
TREADTRD
THREADEDTHRD
TIME CLOCKTC
UNDER COUNTERUCR
VOLTSVA
VERIFY IN FIELDVIF
VINYL FABRICVF
WORK POINTWPT
EXTRA HEAVY
EXTRA STRONG
XHVY
XSTG
DOUBLE EXTRA STRONGXXSTG
Se al
EL
ME
R R . C
HA
SE
, P .E.
PE
Date:
Phase:
Drawn By:
Checked By:
Job No:
TO THE BEST OF THE ARCHITECT'S
AND/OR ENGINEER'S KNOWLEDGE
THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODES AND THE
APPLICABLE FIRE-SAFETY STANDARDS
w
So ut h M an ha tta n Av en ue
,T am pa ,F
L 3
-2
T:8
.8
.0
F:8
.8
.4
AR
C G
C w w lo n ga n da a o o s c i te s s c m
TH
IS D
OC
UM
EN
T IS
C
OP
YR
IG
HT
M
AT
ER
IAL
, A
NY
D
ISC
LO
SU
RE
, U
NA
UT
H0
RIZ
ED
US
E, DIS
SE
MI
NA
TIO
N
OR
D
UP
LIC
AT
IO
N
WI
TH
OU
T T
HE
EX
PR
ES
S W
RIT
TEN
C
ON
SE
NT
O F L
ON
G
AS
SO
CI
AT
ES
IS
PR
OH
IBI
TED
AL
L R
IG
HT
S R
ES
ER
VE
D
L a O N G
A
SS
O C
IA
TE
S r c h it e c t s e n g in e e r s in c
1/6/2025 11:46:06 AM
G0.2
DU
NE
DI
N
HI
G
H
SC
HO
O
L E
XP
AN
SIO
N
JO
IN
T
PI
NE
LL
AS
C O
UN
TY
SC
HO
O
LS
P
IN
EH
UR
ST
R
D.
DU
NE
DI
N, FL
L&A
ERC
100% PERMIT DOCUMENT
23008
DECEMBER 18, 2024
ABBREVIATIONS,
SYMBOL LEGEND, &
MATERIALS LEGEND
A. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE GENERAL CONDITIONS OF THE
CONTRACT AND THE CONSTRUCTION DOCUMENTS.
B. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE 2023 FLORIDA BUILDING CODE 8TH EDITION AND 2023 FLORIDA FIRE PREVENTION CODE. SEE SHEET S0.1 FOR ADDITIONAL APPLICABLE CODES. NOTE: THE ABOVE LISTING IS NOT CONSIDERED TO BE ALL INCLUSIVE AS THERE MAY BE OTHER BUILDING CODE REQUIREMENTS PERTAINING TO THIS SPECIFIC PROJECT.
C. IN SOME CASES, THE REQUIREMENTS SET FORTH IN THE CONSTRUCTION DOCUMENTS EXCEED THE
MINIMUM REQUIREMENTS OF THE CODE.
D. THE CONTRACTOR SHALL COORDINATE THE SEQUENCING AND EXECUTION OF ALL TRADES IN STRICT CONFORMANCE WITH THE REQUIREMENTS OF ALL CONSTRUCTION DRAWINGS AND CONTRACT DOCUMENTS.
E. THE CONTRACTOR SHALL MAINTAIN & PROTECT FROM DAMAGE ALL PORTIONS OF THE EXISTING FACILITY SCHEDULED TO REMAIN OR NOT INDICATED FOR DEMOLITION. ALL DAMAGED AREAS & ELEMENTS
SHALL BE REPLACED TO MATCH EXISTING ADJACENT CONSTRUCTION IN ALL RESPECTS.
F. PRIOR TO ANY DEMOLITION, THE OWNER AND CONTRACTOR SHALL WALK THROUGH THE PROJECT AND ESTABLISH A PUNCH LIST OF EXISTING CONDITIONS. ITEMS NOT IDENTIFIED AND LATER DAMAGED DUE TO
CONSTRUCTION SHALL BE THE CONTRACTORS RESPONSIBILITY.
G. FIELD VERIFY ALL DIMENSIONS PRIOR TO DEMOLITION WORK. COORDINATE AS REQ'D FOR NEW WORK.
H. OWNER SHALL CAREFULLY REMOVE AND ABATE ASBESTOS AS APPLICABLE.
I. THE CONTRACTOR SHALL PROTECT THE PUBLIC FROM CONSTRUCTION ACTIVITIES AND PROVIDE FOR A
SECURE CONSTRUCTION SITE.
J. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT AND TOOLS FOR THE WORK INDICATED ON THE DRAWINGS OR AS SPECIFIED HEREIN. ALL MATERIALS AND APPLIANCES, OBVIOUSLY PART OF THE SYSTEMS AND NECESSARY FOR PROPER OPERATION, SHALL BE FURNISHED AND INSTALLED WITHOUT
ADDITIONAL CHARGE.
K. THE CONTRACTOR SHALL VISIT THE SITE OF THE PROJECT TO BECOME ACQUAINTED WITH THE DIFFICULTIES WHICH MAY ATTEND THE EXECUTION OF THE WORK AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. THE SUBMISSION OF A BID PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH A VISIT AND INVESTIGATION HAS BEEN MADE. CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS FOR DIFFICULTIES
ENCOUNTERED SHALL NOT BE CONSIDERED.
L. WHERE BUILDING COMPONETS ARE IDENTIFIED BY MANUFACTURER AND CATALOG NUMBER, IT SHALL BE CONSTRUED AS THE MINIMUM BASIS OF DESIGN REQUIREMENTS FOR QUALITY AND PERFORMANCE.
CONTRACTOR MAY SUBMIT FOR APPROVAL, SIMILAR EQUIPMENT OF OTHER MANUFACTURERS AS
SUBSTITUTION. THE OWNERS DECISION REGARDING ACCEPTABILITY SHALL BE FINAL AND BINDING.
M. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AT THE SITE A SET OF PRINTS ON WHICH SHALL BE ACCURATELY SHOWN THE ACTUAL INSTALLATION OF ALL WORK UNDER THIS CONTRACT INCLUDING CHANGES IN SIZES, LOCATIONS AND DIMENSIONS. THE PROGRESS PRINTS SHALL BE AVAILABLE FOR REVIEW BY L&A OR OWNER. AT THE COMPLETION OF THE WORK, PREPARE A SET OF RECORD DRAWINGS OF THE WORK AS
ACTUALLY NOTED ON THE MARKED-UP PRINTS.
N. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL, COMPLETE SHOP DRAWINGS INCLUDING SHORING AND THE DETAILS OF ALL MATERIALS, EQUIPMENT AND SYSTEMS TO BE FURNISHED. SUBMIT AS REQUIRED BY THE CONTRACT DOCUMENTS. SUBMITTAL SHALL INCLUDE THE TYPE OF MATERIAL, MANUFACTURER, TECHNICAL SPECIFICATIONS, DIMENSIONS, AND CATALOG OR MODEL NUMBER FOR EACH ITEM. REVIEW OF SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF SHOP DRAWING ERRORS OR OMISSIONS. THE CONTRACTOR SHALL CAREFULLY CHECK AND CORRECT ALL SHOP DRAWINGS
PRIOR TO SUBMISSION FOR REVIEW.
O. THE CONTRACTOR SHALL PROVIDE FOR CUTTING & PATCHING OF ALL EXTERIOR FINISHED SUFACES TO
MATCH EXISTING AS REQUIRED TO FACILITATE SCOPE OF WORK.
P. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH OWNERS POLICIES & PROCEDURES PRIOR TO
COMMENCEMENT OF CONSTRUCTION.
Q. THE INTENT IS FOR THE OWNER TO BE ABLE TO OPERATE PORTIONS OF THE SCHOOL THROUGHOUT CONSTRUCTION. THE CONTRACTOR SHALL CONSTRUCT TEMPORARY DUST & NOISE CONTROL BARRIER AS
REQUIRED FOR THE SAFETY & PROTECTION OF THE OCCUPANTS DURING WORK IN PROCESS AND
THROUGHOUT PHASES OF WORK. COORDINATE SUCH BARRIERS WITH THE OWNER & OCCUPANTS AS
REQUIRED.
R. INFORMATION SHOWN ON THESE PLANS FOR EXISTING BUILDINGS HAS BEEN OBTAINED FROM EXISTING BUILDING DRAWINGS. EXISTING INFORMATION DOES NOT NECESSARILY REFLECT AS BUILD CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL INFORMATION SHOWN ON THESE PLANS AND NOTIFY THE ENGINEER
IMMEDIATELY OF ANY VARIATION.
S. THE CONTRACTOR SHALL PROVIDE TEMPORARY SIGNAGE AS REQUIRED TO RE-ROUTE PEDESTRIANS DURING DEMOLITION AND CONSTRUCTION. ANY DAMAGE TO EXISTING FINISHES AND ELEMENTS TO REMAIN
SHALL BE RESTORED TO LIKE-NEW CONDITION.
SHEET NUMBERING
S0.1
DISCIPLINE
CATAGORY
SHEET NUMBER
NO. DATE ISSUES & REVISIONS
1 03-17-23 60% CDs 2 04-26-2023 100% CD's
3 12-18-2024 100% PERMIT DOCUMENTS
4 01-03-2025 REV #1
El m er R
. C ha se , S ta te o f
Flo rid a, P ro fe ss io na l E ng in ee r, Lic en se N o.
P
E
Th is
Ite m h as b ee n di gi d an d se al ed b y
El m er R
. C ha se , P
E, on us in g a
D ig ita l S ig na tu re
Pr in te d co pi es o f t hi s d oc um en t a re id er ed si gn ed a nd se al ed a nd th e sig na tu re m us t b e ve rif ie d on tro ni c co pi es
/0
6/
A B
12' - 4" 10' - 4" 20' - 8" 8' - 8"
0"
B.7A.6
EX-F60EX-F60EX-F60
EX-F60
EX-F40EX-C
EX-C
EX-C
EX-C
EX-C
EX-C
22' - 8" 29' - 4"
C
CJ
CJ CJ
CJ CJ
CJ
CJ
T/FNDN
EL -2' - 8"
T/FNDN
EL -2' - 8"
FIE
LD
V
ER
IFY
0"
T/RCP
EL -2' - 4"
SD3005
SX3101
SX3101
S0918
SD3005
SX3301SX3301
EXISTING UNDERGROUND (15" RCP)
STORM PIPE PROTECT & MAINTAIN
SX3301SX3301
SX3301SX3301
EXISTING
CONC PEDESTAL
EX-F20W
EX
-F W
COLCOLCOLCOL
T/SLAB
EL 100' - 0"
(FIELD VERIFY)
SX4003
SX0009
EX-F60
SLOPE
EXST SLOPE
(WARPED)
EXST SLOPE
(WARPED)
B/RCP
EL -3'-7"
CO
L
CO
L
REFER TO SX1.1 & SX1.2 FOR PHOTOS SHOWING EXTENT OF
DAMAGE PRIOR TO APPLICATION OF TEMPORARY PATCHES.
ALL TEMPORARY PATCHES TO BE REMOVED IN ORDER TO
REPAIR STRUCTURAL DAMAGE OBSERVED 2/20/2022 PER
THESE DWGS.
NOTE:
T/FNDN
EL -2' - 8"
BLDG B
BLDG A
AREA SHOWN
A. TOP OF SLAB EL VARIES
B. REFER TO DWG S0.1 FOR "STRUCTURAL NOTES"
C. REFER TO SX1.1 AND SX1.2 FOR EXISTING PHOTOS SHOWING EXTENT OF STRUCTURAL
DAMAGE AND ADDITIONAL DEMOLITION NOTES.
NOTES:
EX-F40
SLOPE
LEGEND:
CJ = INDICATES SLAB CONTROL JOINT OR CONSTRUCTION JOINT
= INDICATES SLOPE CONCRETE SLAB
= INDICATES EXISTING FOUNDATION TYPE - SEE SCHEDULE
TOP OF FOUNDATION EL -1'-4", TYP UON
= INDICATES EXISTING CONCRETE COLUMNS - SEE SCHEDULE
= INDICATES EXST STEP IN CONCRETE SLAB
E X
- C 8
2 4
Se al
EL
ME
R R . C
HA
SE
, P .E.
PE
Date:
Phase:
Drawn By:
Checked By:
Job No:
TO THE BEST OF THE ARCHITECT'S
AND/OR ENGINEER'S KNOWLEDGE
THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODES AND THE
APPLICABLE FIRE-SAFETY STANDARDS
w
So ut h M an ha tta n Av en ue
,T am pa ,F
L 3
-2
T:8
.8
.0
F:8
.8
.4
AR
C G
C w w lo n ga n da a o o s c i te s s c m
TH
IS D
OC
UM
EN
T IS
C
OP
YR
IG
HT
M
AT
ER
IAL
, A
NY
D
ISC
LO
SU
RE
, U
NA
UT
H0
RIZ
ED
US
E, DIS
SE
MI
NA
TIO
N
OR
D
UP
LIC
AT
IO
N
WI
TH
OU
T T
HE
EX
PR
ES
S W
RIT
TEN
C
ON
SE
NT
O F L
ON
G
AS
SO
CI
AT
ES
IS
PR
OH
IBI
TED
AL
L R
IG
HT
S R
ES
ER
VE
D
L a O N G
A
SS
O C
IA
TE
S r c h it e c t s e n g in e e r s in c
1/6/2025 11:46:06 AM
SD1.1
DU
NE
DI
N
HI
G
H
SC
HO
O
L E
XP
AN
SIO
N
JO
IN
T
PI
NE
LL
AS
C O
UN
TY
SC
HO
O
LS
P
IN
EH
UR
ST
R
D.
DU
NE
DI
N, FL
L&A
ERC
100% PERMIT DOCUMENT
23008
DECEMBER 18, 2024
EXISTING
FOUNDATION &
SLAB DEMOLITION
PLAN
SCALE: 1/4" = 1'-0"1 EXISTING FOUNDATION & SLAB DEMOLITION PLAN
KEYNOTE LEGEND
NO. DESCRIPTION
S0918 AT CONTRACTOR OPTION, EXISTING WALKWAY CANOPY COLUMN MAY BE REMOVED AND
REPLACED TO MATCH EXISTING AS REQUIRED FOR NEW WORK ALL DISTURBED OR REPLACED
CANOPY COMPONENTS AND FASTENERS TO BE DESIGNED BY SPECIALTY ENGINEER.
CONTRACTOR TO COORDINATE
SD3005 PERIMETER OF CONCRETE SLAB DEMOLITION TO BE CAREFULLY SAW-CUT AS REQUIRED FOR
NEW WORK. CONTRACTOR TO NOTIFY ENGINEER OF RECORD WHEN SLAB AND SOILS HAVE
BEEN REMOVED AND DEMOLITION IS COMPLETE IN THIS AREA IN ORDER TO OBSERVE AND
CONFIRM DESIGN ASSUMPTIONS FOR EXISTING FOUNDATION CONDITIONS BELOW GRADE.
ENGINEER RESERVES THE RIGHT TO REVISE THE FOUNDATION SHOWN SUBJECT TO DISCOVERY
OF UNFORSEEN CONDITIONS
SX0009 CROWN IN EXISTING CONCRETE SLAB
SX3101 EXISTING CONCRETE FOUNDATION. PROTECT & MAINTAIN
SX3301 EXISTING CONCRETE SLAB. PROTECT & MAINTAIN (UON)
SX4003 EXISTING MASONRY WALL, PROTECT & MAINTAIN
SCALE:NTS
KEYPLAN
N
N
0' 2' 4' 8'
NO. DATE ISSUES & REVISIONS
1 03-17-23 60% CDs 2 04-26-2023 100% CD's
3 12-18-2024 100% PERMIT DOCUMENTS
4 01-03-2025 REV #1
A
El m er R
. C ha se , S ta te o f
Flo rid a, P ro fe ss io na l E ng in ee r, Lic en se N o.
P
E
Th is
Ite m h as b ee n di gi d an d se al ed b y
El m er R
. C ha se , P
E, on us in g a
D ig ita l S ig na tu re
Pr in te d co pi es o f t hi s d oc um en t a re id er ed si gn ed a nd se al ed a nd th e sig na tu re m us t b e ve rif ie d on tro ni c co pi es
/0
6/
A B
B.7A.6
SD2.1
12' - 4" 10' - 4" 20' - 8" 8' - 8"
0"
C 22' - 8" 29' - 4"
SL
O
PEEXISTING 8" HOLLOW CORE W/
2" CONCRETE SLAB TOPPING
PROTECT & MAINTAIN (UON)
S0919S0919
WALKWAY
CANOPY
ROOF BELOW
NOTE: TEMPORARY SHORING IS REQUIRED
AND SHALL BE DESIGNED BY A SPECIATY
STRUCTURAL ENGINEER CURRENTLY
REGISTERED IN THE STATE OF FLORIDA
PRIOR TO ANY DEMOLITION WORK
CAREFULLY REMOVE 2"
CONCRETE TOPPING AS
REQUIRED FOR NEW WORK
DO NOT REMOVE HC
EXISTING CONCRETE BEAM
PROTECT & MAINTAINEXISTING CONCRETE BEAM
PROTECT & MAINTAIN
S0919S0919
CROWN OF EXST SLAB TOPPING
EXST SLOPE
(WARPED)
EXST SLOPE
(WARPED)
COL COLCOLCOL
CO
L
CO
L
REFER TO SX1.1 & SX1.2 FOR PHOTOS SHOWING EXTENT OF
DAMAGE PRIOR TO APPLICATION OF TEMPORARY PATCHES.
ALL TEMPORARY PATCHES TO BE REMOVED IN ORDER TO
REPAIR STRUCTURAL DAMAGE OBSERVED 2/20/2022 PER
THESE DWGS.
NOTE:
SX3308SX3308
SD3006
SX3404
SD3006
(ALL SIDES)
S0919S0919
CANOPY DRAIN COLUMN
FIELD VERIFY
DE
MO
EX
ST
FI
EL
D
VE
RI
FY
3'
- 0
3'
- 0
+/- 10" +/- 4 1/2"
EX
ST
S
LO
PE
B
REMOVE CONT L6X6 & STIFFENER PLATES,
CUT EXPOSTED END OF ANCHOR BOLTS
AND DRILL OUT BOLTS 2" PAST FACE OF
CONCRETE AND GROUT HOLE FLUSH W/
FACE OF CONCRETE AFTER SHORING HAS
BEEN INSTALLED
REMOVE PORITION OF
2" CONCRETE TOPPING AS
REQUIRED FOR NEW WORK
FIELD VERIFYNOTE:
TEMPORARY SHORING IS
REQUIRED AND SHALL BE
DESIGNED BY A SPECIATY
STRUCTURAL ENGINEER
CURRENTLY REGISTERED IN
THE STATE OF FLORIDA
FOR NEW WORK
REMOVE 2" CONC TOPPING
+/- 4" AS REQUIRED
EXISTING
EXP JT
FOR NEW WORK
REMOVE 2" CONC TOPPING
+/- 9" AS REQUIRED
8"x24" EXISTING CONCRETE
BEAM REINF W/ (2) #8 T&B &
#3 CLOSED TIES @ 10" OC
PROTECT & MAINTAIN
PROTECT & MAINTAIN EXISTING
HOLLOW CORE PLANK
CAREFULLY REMOVE PORITION OF
2" (MIN THICKNESS AT SLAB EDGE -
LOW POINT) CONCRETE TOPPING
AS REQUIRED FOR NEW WORK.
EXERCISE CAUTION SO AS TO NOT
DAMAGE HC SLAB
FIELD VERIFY AND NEATLY
SAW-CUT PRECAST PLANK
AS REQUIRED FOR NEW 2"
EXP JT - REF TO DWG S2.1
4" 4"
EXST BM
REMOVE & DISPOSE OF EXISTING
EXPANSION JOINT COVER PLATE
T/CONC BM
EL +/- 12'-6"
BLDG B
BLDG A
AREA SHOWN
A. REFER TO DWG S0.1 FOR "STRUCTURAL NOTES"
B. REFER TO DETAIL 1 ON DWG S0.1 FOR "MINIMUM COMPONENT & CLADDING NOMINAL
DESIGN WIND LOADS (PSF)"
C. REFER TO SX1.1 AND SX1.2 FOR EXISTING PHOTOS SHOWING EXTENT OF STRUCTURAL
DAMAGE AND ADDITIONAL DEMOLITION NOTES.
NOTES:
= INDICATES SLOPE OF EXISTING CONCRETE TOPPING SLAB
LEGEND:
EXST SLOPE
Se al
EL
ME
R R . C
HA
SE
, P .E.
PE
Date:
Phase:
Drawn By:
Checked By:
Job No:
TO THE BEST OF THE ARCHITECT'S
AND/OR ENGINEER'S KNOWLEDGE
THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODES AND THE
APPLICABLE FIRE-SAFETY STANDARDS
w
So ut h M an ha tta n Av en ue
,T am pa ,F
L 3
-2
T:8
.8
.0
F:8
.8
.4
AR
C G
C w w lo n ga n da a o o s c i te s s c m
TH
IS D
OC
UM
EN
T IS
C
OP
YR
IG
HT
M
AT
ER
IAL
, A
NY
D
ISC
LO
SU
RE
, U
NA
UT
H0
RIZ
ED
US
E, DIS
SE
MI
NA
TIO
N
OR
D
UP
LIC
AT
IO
N
WI
TH
OU
T T
HE
EX
PR
ES
S W
RIT
TEN
C
ON
SE
NT
O F L
ON
G
AS
SO
CI
AT
ES
IS
PR
OH
IBI
TED
AL
L R
IG
HT
S R
ES
ER
VE
D
L a O N G
A
SS
O C
IA
TE
S r c h it e c t s e n g in e e r s in c
1/6/2025 11:46:08 AM
SD2.1
DU
NE
DI
N
HI
G
H
SC
HO
O
L E
XP
AN
SIO
N
JO
IN
T
PI
NE
LL
AS
C O
UN
TY
SC
HO
O
LS
P
IN
EH
UR
ST
R
D.
DU
NE
DI
N, FL
L&A
ERC
100% PERMIT DOCUMENT
23008
DECEMBER 18, 2024
EXISTING 2ND
FLOOR FRAMING
DEMOLITION PLAN
SCALE: 1/4" = 1'-0"1 EXISTING 2ND FLOOR FRAMING DEMOLITION PLAN
KEYNOTE LEGEND
NO. DESCRIPTION
S0919 REMOVE EXISTING WALKWAY CANOPY ROOF PANEL DECK TO DRAIN COLUMN AND FRAME AS
REQUIRED. PROVIDE AND INSTALL NEW CANOPY FRAME AND ROOF DESIGN BY A SPECIALTY
ENGINEER - MATCH EXISTING ON COMPLETION OF 2" EXPANSION JOINT CONSTRUCTION.
SD3006 CAREFULLY CHIP AWAY AND REMOVE +/- 2'-0" X 3'-0" OF CONCRETE ALONG THE SOUTH END OF
EACH HC WALKWAY EDGE BEAM WHILE MAINTAINING INTACT THE EXISTING (2) #4
LONGITUDINAL BEAM REINFORCING BARS AND #4 BARS @ 16" OC CAST WITHIN THE 2"
CONCRETE TOPPING AND HOOKED INTO THE HC WALKWAY EDGE BEAM IN ORDER TO PREPARE
FOR WORK SHOWN IN SECTION 3/ S2.1
SX3308 EXISTING 8" HOLLOW CORE PLANKS W/ 2" (+/-) CONCRETE TOPPING, PROTECT & MAINTAIN SX3404 REFER TO DRAWING SX1.1 AND SX1.2 FOR HISTORICAL PHOTOS SHOWING THE EXTENT OF
CONCRETE DISTRESS BEFORE AND AFTER TEMPORARY REPAIRS. REMOVE TEMPORARY
REPAIRS AND STUCCO FINISH FROM STRUCTURALLY DISTRESSED CONCRETE COLUMNS AND
BEAMS IN ORDER TO REPAIR CONCRETE DAMAGE ACCORDING TO "TYPICAL CONCRETE REPAIR"
DETAIL 5/ S4.1.
SCALE: 3/4" = 1'-0"2 SECTION
SCALE:NTS
KEYPLAN
N
N
0' 2' 4' 8'
NO. DATE ISSUES & REVISIONS
1 03-17-23 60% CDs 2 04-26-2023 100% CD's
3 12-18-2024 100% PERMIT DOCUMENTS
4 01-03-2025 REV #1
A
El m er R
. C ha se , S ta te o f
Flo rid a, P ro fe ss io na l E ng in ee r, Lic en se N o.
P
E
Th is
Ite m h as b ee n di gi d an d se al ed b y
El m er R
. C ha se , P
E, on us in g a
D ig ita l S ig na tu re
Pr in te d co pi es o f t hi s d oc um en t a re id er ed si gn ed a nd se al ed a nd th e sig na tu re m us t b e ve rif ie d on tro ni c co pi es
/0
6/
BLDG B
BLDG A
AREA SHOWN
A B
B.7 C
22' - 8" 29' - 4" 20' - 8" 8' - 8"
SD3.1
EX-16K2
EX-16K2
EX-16K2
EX-16K2
EX-W18X35
EX-10" DIA PIPE XS
EX-22K4
4:1
0"
SD3.1
DE
CK
SP
AN
DE
CK
SP
AN
DE
CK
SP
AN
E X - TS 5 X 3 X 1 / 4
SD3.1
E X
- T S
5 X 3 X 1 / 4
( T Y P )
METAL ROOF PANEL DECK
PROTECT & MAINTAIN
CAREFULLY REMOVE ROOFING,
EXISTING METAL DECK & FLASHING
AS REQUIRED FOR NEW WORK
CAREFULLY REMOVE STUCCO
FASCIA, SOFFIT AND STUD FRAMING
AS REQUIRED FOR NEW WORK
CAREFULLY REMOVE STUCCO
FASCIA, SOFFIT AND STUD FRAMING
AS REQUIRED FOR NEW WORK
CAREFULLY REMOVE ROOFING,
EXISTING METAL DECK & FLASHING
AS REQUIRED FOR NEW WORK
SX0901SX0901
EXISTING CONCRETE BEAM
PROTECT & MAINTAIN
EXISTING
RF DRAIN
EX
ST
S
LO
PE
EX-TS4X2X3/16
COL
CO
L
COLCOL
CO
L
SX6002SX6002
EX-TS4X2X3/16
(TYP)
W/ TS5x3x1/4 ABOVE
COL
B
EXISTING JOIST SEAT TO
BE MODIFIED FOR NEW
WORK - REFER TO
SECTION & DETAILS
REMOVE ROOFING
SYSTEM AS REQUIRED
TEMPORARY SHORING AS
REQUIRED SHALL BE DESIGNED
BY A SPECIATY STRUCTURAL
ENGINEER CURRENTLY
REGISTERED IN THE STATE OF
FLORIDA EXTEND TO SLAB ON
GRADE
REMOVE STUCCO SOFFIT
AND STUD FRAMING AS
REQUIRED FOR WORK
FIELD VERIFY
EXISTING
STUCCO FASCIA
PROTECT & MAINTAIN
SD1001
SX1001
SX0901
SAW-CUT & REMOVE METAL
ROOFING AS REQUIRED
FOR NEW WORK
REMOVE PT WD BLOCKING
& METAL ROOFING
FLASHING
3" 2"
CENTER OF NEW CONC BEAM
REFER TO DWG S3.1
AS REQ'D, FIELD VERIFY
CUT & REMOVE PORTION OF JOIST
TOP CHORD & SEAT
SX3405
CENTER OF EXISTING
CONC BEAM
SX0901SX0901
A. REFER TO DWG S0.1 FOR "STRUCTURAL NOTES"
B. REFER TO DETAIL 1 ON DWG S0.1 FOR "MINIMUM COMPONENT & CLADDING NOMINAL
DESIGN WIND LOADS (PSF)"
C. REFER TO SX1.1 AND SX1.2 FOR EXISTING PHOTOS SHOWING EXTENT OF STRUCTURAL
DAMAGE AND ADDITIONAL DEMOLITION NOTES.
NOTES:
= INDICATES EXISTING METAL ROOF DECK SPAN DIRECTION
= INDICATES SLOPE OF EXISTING METAL ROOF DECK
= INDICATES EXISTING STEEL FRAMING MEMBER SIZE,
PROTECT & MAINTAIN, FIELD LOCATE AS REQUIRED
LEGEND:
DECK
SPAN
EXST SLOPE
EX-16K2
B
EXISTING BEAM CONNECTION
TO EMBED PLATE TO BE
REPAIRED, REF PHOTO 2E
REMOVE STUCCO FASCIA
AND STUD FRAMING AS
REQUIRED FOR WORK
REMOVE EXISTING
METAL DECK, ROOFING &
FLASHING AS REQUIRED
FOR NEW WORK
EXISTING ROOF FRAMING
BEYOND TO BE MODIFIED FOR
NEW EXPANSION JOINT - REFER
TO STRUCTURAL DWGS FOR
ADDITIONAL INFO
SX3404
SD0002
(ALL SIDES)
SD0002
ALUMINUM GUARDRAIL
REF PHOTO 2D
SX3404 (ALL SIDES)
SX5003
SX0901SX0901
EX-W18EX-22K
SX5007SX5007SX5007
EX-TS5x3
NOTE: THIS SECTION PROVIDED
FOR GENERAL REFERENCE
Se al
EL
ME
R R . C
HA
SE
, P .E.
PE
Date:
Phase:
Drawn By:
Checked By:
Job No:
TO THE BEST OF THE ARCHITECT'S
AND/OR ENGINEER'S KNOWLEDGE
THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODES AND THE
APPLICABLE FIRE-SAFETY STANDARDS
w
So ut h M an ha tta n Av en ue
,T am pa ,F
L 3
-2
T:8
.8
.0
F:8
.8
.4
AR
C G
C w w lo n ga n da a o o s c i te s s c m
TH
IS D
OC
UM
EN
T IS
C
OP
YR
IG
HT
M
AT
ER
IAL
, A
NY
D
ISC
LO
SU
RE
, U
NA
UT
H0
RIZ
ED
US
E, DIS
SE
MI
NA
TIO
N
OR
D
UP
LIC
AT
IO
N
WI
TH
OU
T T
HE
EX
PR
ES
S W
RIT
TEN
C
ON
SE
NT
O F L
ON
G
AS
SO
CI
AT
ES
IS
PR
OH
IBI
TED
AL
L R
IG
HT
S R
ES
ER
VE
D
L a O N G
A
SS
O C
IA
TE
S r c h it e c t s e n g in e e r s in c
1/6/2025 11:46:09 AM
SD3.1
DU
NE
DI
N
HI
G
H
SC
HO
O
L E
XP
AN
SIO
N
JO
IN
T
PI
NE
LL
AS
C O
UN
TY
SC
HO
O
LS
P
IN
EH
UR
ST
R
D.
DU
NE
DI
N, FL
L&A
ERC
100% PERMIT DOCUMENT
23008
DECEMBER 18, 2024
EXISTING ROOF
FRAMING
DEMOLITION PLAN
SCALE:NTS
KEYPLAN
N
KEYNOTE LEGEND
NO. DESCRIPTION
SD0002 CAREFULLY DETACH AND REMOVE EXISTING GUARDRAIL CONNECTION AS REQUIRED FOR NEW
CONSTRUCTION.
SD1001 REMOVE EXISTING CAULKING, CLEAN AND PREPARE SURFACES FOR NEW CAULKING
SX0901 EXISTING ROOFING & ROOF FRAMING PROTECT & MAINTAIN
SX1001 EXISTING FLASHING, PROTECT & MAINTAIN
SX3404 REFER TO DRAWING SX1.1 AND SX1.2 FOR HISTORICAL PHOTOS SHOWING THE EXTENT OF
CONCRETE DISTRESS BEFORE AND AFTER TEMPORARY REPAIRS. REMOVE TEMPORARY
REPAIRS AND STUCCO FINISH FROM STRUCTURALLY DISTRESSED CONCRETE COLUMNS AND
BEAMS IN ORDER TO REPAIR CONCRETE DAMAGE ACCORDING TO "TYPICAL CONCRETE REPAIR"
DETAIL 5/ S4.1.
SX3405 EXISTING CONCRETE BEAM PROTECT & MAINTAIN
SX5003 EXISTING STEEL BEAM PROTECT & MAINTAIN
SX5007 EXISTING CFS FRAMING, PROTECT & MAINTAIN
SX6002 EXISTING STEEL JOIST BRIDGING - PROTECT & MAINTAIN
SCALE: 1/4" = 1'-0"1 EXISTING ROOF FRAMING DEMOLITION PLANN
0' 2' 4' 8'
SCALE: 3/4" = 1'-0"3 SECTION
SCALE: 3/4" = 1'-0"2 SECTION
SCALE: 3/4" = 1'-0"4 SECTION
NO. DATE ISSUES & REVISIONS
1 03-17-23 60% CDs 2 04-26-2023 100% CD's
3 12-18-2024 100% PERMIT DOCUMENTS
4 01-03-2025 REV #1
A
El m er R
. C ha se , S ta te o f
Flo rid a, P ro fe ss io na l E ng in ee r, Lic en se N o.
P
E
Th is
Ite m h as b ee n di gi d an d se al ed b y
El m er R
. C ha se , P
E, on us in g a
D ig ita l S ig na tu re
Pr in te d co pi es o f t hi s d oc um en t a re id er ed si gn ed a nd se al ed a nd th e sig na tu re m us t b e ve rif ie d on tro ni c co pi es
/0
6/
SD3006
S0028S0028
TEMPORARY PATCH 2ND FLOOR PHOTO 4A - 2/20/2023
SD3006
REF PHOTO 4C
2ND FLOOR, WEST INTERIOR ELEVATION OF CORRIDOOR
A & B PHOTO 5A - 2/20/2023
BUILDING
EXPANSION JOINT
REF PHOTO 5B
REF PHOTO
1/SX1.2 FOR LIMITS
OF FLOOR CRACKS
AND SIKAGARD
2ND FLOOR PHOTO 2A - 6/30/2022
SD3006
2ND FLOOR PHOTO 2B - 6/30/2022
SD3006
2ND FLOOR PHOTO 6B - 2/20/2023
S0023
SD3006
SD0002SD0002
SX0006
2ND FLOOR PHOTO 6A- 2/20/2023
S0023
ROOF PHOTO 2F - 6/30/2022
ROOF PHOTO 2E - 6/30/2022
SD0001
S5022
S5021
S5023
S3031 S3032 }-
S5020
S5020S5020S5020
2ND FLOOR PHOTO 5B - 2/20/2023
SD0002
SX0006
SD0002
SX0008
BUILDING EXPANSION JOINT LOCATION
2ND FLOOR PHOTO 4B - 6/30/2022
SD3006
EXTENT OF STRUCTURAL DAMAGE
TEMPORARY PATCH 2ND FLOOR PHOTO 4C - 2/20/2023
SD3006
TEMPORARY PATCH 2ND FLOOR PHOTO 2C - 2/20/2023
EXTENT OF
STRUCTURAL
DAMAGE
ELEVATION AT BUILDINGEXPANSION JOINT
PHOTO - 6/30/2022
PHOTO 2D, 2E, 2F
PHOTO 2A, 2B, 2C
ROOF FASCIA PHOTO 2D 6/30/2022
SD0002
SD0002SD0002
SX0008
S5022S5022S5022
SX0006
Se al
EL
ME
R R . C
HA
SE
, P .E.
PE
Date:
Phase:
Drawn By:
Checked By:
Job No:
TO THE BEST OF THE ARCHITECT'S
AND/OR ENGINEER'S KNOWLEDGE
THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODES AND THE
APPLICABLE FIRE-SAFETY STANDARDS
w
So ut h M an ha tta n Av en ue
,T am pa ,F
L 3
-2
T:8
.8
.0
F:8
.8
.4
AR
C G
C w w lo n ga n da a o o s c i te s s c m
TH
IS D
OC
UM
EN
T IS
C
OP
YR
IG
HT
M
AT
ER
IAL
, A
NY
D
ISC
LO
SU
RE
, U
NA
UT
H0
RIZ
ED
US
E, DIS
SE
MI
NA
TIO
N
OR
D
UP
LIC
AT
IO
N
WI
TH
OU
T T
HE
EX
PR
ES
S W
RIT
TEN
C
ON
SE
NT
O F L
ON
G
AS
SO
CI
AT
ES
IS
PR
OH
IBI
TED
AL
L R
IG
HT
S R
ES
ER
VE
D
L a O N G
A
SS
O C
IA
TE
S r c h it e c t s e n g in e e r s in c
1/6/2025 11:46:13 AM
SX1.1
DU
NE
DI
N
HI
G
H
SC
HO
O
L E
XP
AN
SIO
N
JO
IN
T
PI
NE
LL
AS
C O
UN
TY
SC
HO
O
LS
P
IN
EH
UR
ST
R
D.
DU
NE
DI
N, FL
L&A
ERC
100% PERMIT DOCUMENT
23008
DECEMBER 18, 2024
EXISTING PHOTOS
SCALE: NTS3 EXISTING PHOTO
SCALE: NTS4 EXISTING PHOTOS
SCALE: NTS5 EXISTING PHOTOS
SCALE: NTS6 EXISTING PHOTO
SCALE: NTS1 EXISTING COURTYARD PHOTO
SCALE: NTS2 EXISTING PHOTOS
NOTE:
ALL TEMPORARY PATCHES TO BE REMOVED IN ORDER TO REPAIR
STRUCTURAL DAMAGE OBSERVED 2/20/2022 PER THESE DWGS.
EXTENT OF STRUCTURAL DAMAGE
EXTENT OF
STRUCTURAL
DAMAGE
KEYNOTE LEGEND
NO. DESCRIPTION
S0023 ROUT AND SEAL ALL CRACKS 1/32" OR WIDER IN THE EXISTING CONCRETE
SURFACE OF THE EXISTING 2ND FLOOR WALKWAY PURSUANT TO DETAIL
1/S4.1 "GRAVITY FED EPOXY, RIGID CRACK REPAIR", WITHIN THE AREA OF
WORK THAT IS HEREIN DEFINED AS BETWEEN GRID LINES A-B/1-2. AFTER THE
CRACKS HAVE BEEN SEALED AND THE SURFACE HAS BEEN PRESSURE
WASHED CLEAN, APPLY (1) COAT OF SIKAGARD 740W SILANE BASED
REACTIVE WATER REPELLENT PENETRATING SEALER INSTALLED IN STRICT
ACCORDANCE WITH ALL MANUF'S RECOMMENDATIONS.
S0028 PROVIDE CONTROL JOINTS IN NEW CEMENTITIOUS FINISH ON BEAMS AND
COLUMNS TO MATCH THE EXISTING ADJACENT CONSTRUCTION
S3031 ROUT AND SEAL EXISTING VERTICAL CRACKS IN CONCRETE 1/32" TO 1/4" IN
WIDTH. SET APPROPRIATE INJECTION PORTS. SEAL PORTS AND SURFACE OF
CRACK W/ SIKADUR 31 / SIKADUR 33 HI-MOD GEL (OR APPROVED EQUAL).
WHEN THE EPOXY ADHESIVE SEAL HAS CURED, INJECT SIKARDUR CRACK FIX
/ SIKADUR 35, SIKADUR 52 OR SIKADUR 55 (BASIS OF DESIGN) (OR APPROVED
EQUAL) WITH SLOW STEADY PRESSURE. REPAIR SURFACE TEXTURE TO
MATCH EXISTING.
S3032 REFER TO DETAIL 5/S4.1 FOR "TYPICAL CONCRETE REPAIR" AS APPLICABLE
S5020 ALL CORRODED STEEL BOLTS, CLIPS, AND SHEAR TAB CONNECTION
ELEMENTS IN STRUCTURAL DAMAGE ZONES SHALL BE GRINDED SMOOTH
AND SAND BLAST CLEAN IN ACCORDANCE WITH SSP3 SP6. STEEL SECTIONS
CONTAINING DEGREGATIONS EXCEEDING 10% OF THEIR ORIGINAL
CROSS-SECTIONAL AREA SHALL BE REPLACED WITH NEW, MATCHING, STEEL
SECTIONS NO LESS THAN 5/16" THICK FOR CLIP ANGLES AND 1/2" THICK FOR
SHEAR TABS. PAINT REPAIRED STEEL TO MATCH EXISTING AFTER ALL
REPAIRS ARE COMPLETE.
S5021 PROVIDE 1/4" THICK PLATE WASHER LARGE ENOUGH TO COVER ENTIRE
SLOTTED HOLE
S5022 (3) 3/4" DIAMETER, ASTM A325 BOLTS, FINGER TIGHT WITH BURRED THREADS,
CENTERED IN HORIZONTAL, LONG SLOTTED HOLE
S5023 EX-10" DIAMETER PIPE AND TS 5X3 ABOVE SHALL TERMINATE NO LESS THAN
1/2" FROM FACE OF FINISH WALL/COLUMN TEXTURE. CUT AND REINSTALL
WATER TIGHT STEEL END PLATES TO MATCH EXISTING AS REQUIRED.
SD0001 CAREFULLY REMOVE STUCCO IN ORDER TO EXPOSE ALL CRACKED AND
DAMAGED CONCRETE WITHIN THE EXTENTS OF STRUCTURAL DAMAGE ZONE
SHOWN.
SD0002 CAREFULLY DETACH AND REMOVE EXISTING GUARDRAIL CONNECTION AS
REQUIRED FOR NEW CONSTRUCTION.
SD3006 CAREFULLY CHIP AWAY AND REMOVE +/- 2'-0" X 3'-0" OF CONCRETE ALONG
THE SOUTH END OF EACH HC WALKWAY EDGE BEAM WHILE MAINTAINING
INTACT THE EXISTING (2) #4 LONGITUDINAL BEAM REINFORCING BARS AND #4
BARS @ 16" OC CAST WITHIN THE 2" CONCRETE TOPPING AND HOOKED INTO
THE HC WALKWAY EDGE BEAM IN ORDER TO PREPARE FOR WORK SHOWN IN
SECTION 3/ S2.1
SX0006 SECURE EXISTING GUARDRAIL TO NEW CONCRETE COLUMN - MATCH
EXISTING CONNECTION
SX0008 SECURE EXISTING GUARDRAIL TO SOFFIT FRAMING - MATCH EXISTING
CONNECTION
NO. DATE ISSUES & REVISIONS
1 03-17-23 60% CDs 2 04-26-2023 100% CD's
3 12-18-2024 100% PERMIT DOCUMENTS
4 01-03-2025 REV #1
El m er R
. C ha se , S ta te o f
Flo rid a, P ro fe ss io na l E ng in ee r, Lic en se N o.
P
E
Th is
Ite m h as b ee n di gi d an d se al ed b y
El m er R
. C ha se , P
E, on us in g a
D ig ita l S ig na tu re
Pr in te d co pi es o f t hi s d oc um en t a re id er ed si gn ed a nd se al ed a nd th e sig na tu re m us t b e ve rif ie d on tro ni c co pi es
/0
6/
S0024
S0903
2ND FLOOR PHOTO 1 - 2/20/2023
2ND FLOOR PHOTO 1A - 6/30/2022
2ND FLOOR PHOTO 1B - 6/30/2022
SI KAG AR D -7 4 0 W W ATER R EPEL L EN T
L I MI TS O F FL O O R C R AC K R EPAI R AN D
EXP J T TO G R I D L I N E "B"
EXTEN D + / - 2 ' -0 " BEYO N D
S0023
SX3308
S0023
SX3308
S0023
S0024
S0023S0023S0023
S0023
C J
SX3308SX3308
S0023S0023
SX3308SX3308
SD0002
SX0006
SD3006
S0024
SD0002
SX0007
SX3308
Se al
EL
ME
R R . C
HA
SE
, P .E.
PE
Date:
Phase:
Drawn By:
Checked By:
Job No:
TO THE BEST OF THE ARCHITECT'S
AND/OR ENGINEER'S KNOWLEDGE
THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODES AND THE
APPLICABLE FIRE-SAFETY STANDARDS
w
So ut h M an ha tta n Av en ue
,T am pa ,F
L 3
-2
T:8
.8
.0
F:8
.8
.4
AR
C G
C w w lo n ga n da a o o s c i te s s c m
TH
IS D
OC
UM
EN
T IS
C
OP
YR
IG
HT
M
AT
ER
IAL
, A
NY
D
ISC
LO
SU
RE
, U
NA
UT
H0
RIZ
ED
US
E, DIS
SE
MI
NA
TIO
N
OR
D
UP
LIC
AT
IO
N
WI
TH
OU
T T
HE
EX
PR
ES
S W
RIT
TEN
C
ON
SE
NT
O F L
ON
G
AS
SO
CI
AT
ES
IS
PR
OH
IBI
TED
AL
L R
IG
HT
S R
ES
ER
VE
D
L a O N G
A
SS
O C
IA
TE
S r c h it e c t s e n g in e e r s in c
1/6/2025 11:46:14 AM
SX1.2
DU
NE
DI
N
HI
G
H
SC
HO
O
L E
XP
AN
SIO
N
JO
IN
T
PI
NE
LL
AS
C O
UN
TY
SC
HO
O
LS
P
IN
EH
UR
ST
R
D.
DU
NE
DI
N, FL
L&A
ERC
100% PERMIT DOCUMENT
23008
DECEMBER 18, 2024
EXISTING PHOTOS
SCALE: NTS2 EXISTING PHOTO 2/20/2023
SCALE: NTS1 EXISTING CRACKS IN TO HC TOPPING
SCALE: 1/4" = 1'-0"3 EXISTING PHOTO 06/30/22
NOTE:
ALL TEMPORARY PATCHES TO BE REMOVED IN ORDER TO REPAIR
STRUCTURAL DAMAGE OBSERVED 2/20/2022 PER THESE DWGS.
KEYNOTE LEGEND
NO. DESCRIPTION
S0023 ROUT AND SEAL ALL CRACKS 1/32" OR WIDER IN THE EXISTING CONCRETE SURFACE OF THE EXISTING 2ND FLOOR
WALKWAY PURSUANT TO DETAIL 1/S4.1 "GRAVITY FED EPOXY, RIGID CRACK REPAIR", WITHIN THE AREA OF WORK THAT IS HEREIN DEFINED AS BETWEEN GRID LINES A-B/1-2. AFTER THE CRACKS HAVE BEEN SEALED AND THE SURFACE HAS BEEN PRESSURE WASHED CLEAN, APPLY (1) COAT OF SIKAGARD 740W SILANE BASED REACTIVE WATER REPELLENT PENETRATING SEALER INSTALLED IN STRICT ACCORDANCE WITH ALL MANUF'S RECOMMENDATIONS.
S0024 2" BUILDING EXPANSION JOINT LOCATION
S0903 SIKASIL WS-290 SILICONE JOINT SEALANT INSTALLED IN STRICT ACCORDANCE WITH MANUF'S RECOMMENDATIONS SD0002 CAREFULLY DETACH AND REMOVE EXISTING GUARDRAIL CONNECTION AS REQUIRED FOR NEW CONSTRUCTION.
SD3006 CAREFULLY CHIP AWAY AND REMOVE +/- 2'-0" X 3'-0" OF CONCRETE ALONG THE SOUTH END OF EACH HC WALKWAY EDGE
BEAM WHILE MAINTAINING INTACT THE EXISTING (2) #4 LONGITUDINAL BEAM REINFORCING BARS AND #4 BARS @ 16" OC CAST WITHIN THE 2" CONCRETE TOPPING AND HOOKED INTO THE HC WALKWAY EDGE BEAM IN ORDER TO PREPARE FOR
WORK SHOWN IN SECTION 3/ S2.1
SX0006 SECURE EXISTING GUARDRAIL TO NEW CONCRETE COLUMN - MATCH EXISTING CONNECTION SX0007 SECURE EXISTING GUARDRAIL TO REPAIRED CONCRETE SLAB - MATCH EXISTING CONNECTION SX3308 EXISTING 8" HOLLOW CORE PLANKS W/ 2" (+/-) CONCRETE TOPPING, PROTECT & MAINTAIN
NO. DATE ISSUES & REVISIONS
1 03-17-23 60% CDs 2 04-26-2023 100% CD's
3 12-18-2024 100% PERMIT DOCUMENTS
4 01-03-2025 REV #1
El m er R
. C ha se , S ta te o f
Flo rid a, P ro fe ss io na l E ng in ee r, Lic en se N o.
P
E
Th is
Ite m h as b ee n di gi d an d se al ed b y
El m er R
. C ha se , P
E, on us in g a
D ig ita l S ig na tu re
Pr in te d co pi es o f t hi s d oc um en t a re id er ed si gn ed a nd se al ed a nd th e sig na tu re m us t b e ve rif ie d on tro ni c co pi es
/0
6/
001 DESIGN CRITERIA
001.1 ALL WORK SHALL CONFORM TO THE STANDARDS OF THE 2023 FLORIDA BUILDING CODE, 8TH EDITION, THE 2023 FLORIDA BUILDING CODE - EXISTING BUILDING, 8TH EDITION, AND THE 2023 FLORIDA FIRE PREVENTION CODE, 8TH EDITION
001.2 DEAD LOADS:
ACTUAL WEIGHT OF MATERIAL USED
LIVE LOADS:
SLAB-ON-GRADE 100 PSF
ROOF 20 PSF
CORRIDORS ABOVE FLOOR 80 PSF
HANDRAILS & GUARDRAILS 50 PLF OR 200 LBS CONCENTRATED LOAD (WHICHEVER IS GREATER)
GRAB BARS 250 LBS CONCENTRATED LOAD APPLIED IN ANY DIRECTION AT ANY POINT
001.2.1 COLATERAL LOADS AS SHOWN ON THE DESIGN DRAWINGS.
001.3 WIND LOADS PER AMERICAN SOCIETY OF CIVIL ENGINEERS ASCE 7-22 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES."
001.4 THE PROPOSED STRUCTURE IS LOCATED WITHIN THE WIND-BORNE DEBRIS REGION. REFERENCE SECTION 1609.1.2 FBC.
001.5 BASIC WIND SPEED, (3 SECOND GUST) VULT = 153 MPH (ULTIMATE WIND SPEED)
VASD = 119 MPH (EQUIVALENT NOMINAL WIND SPEED)
001.6 WIND DIRECTIONALITY FACTOR (Kd) = 0.85
001.7 BUILDING RISK CATEGORY = III
001.8 WIND EXPOSURE CATEGORY = EXPOSURE C, WITH NO SIGNIFICANT ESCARPMENTS.
001.9 BUILDING ENCLOSURE CLASSIFICATION = ENCLOSED BUILDING
001.10 INTERNAL PRESSURE COEFFICIENT (GCpi) = +/- 0.18
001.11 ALL EXTERIOR COMPONENT AND CLADDING SHALL BE DESIGNED TO RESIST THE WIND PRESSURES INDICATED IN THE WALL AND ROOF "MINIMUM COMPONENT AND CLADDING NOMINAL DESIGN WIND PRESSURES" TABLES ON THESE DRAWINGS.
001.12 SEISMIC ZONE: ZERO.
001.13 EXISTING BUILDING GRAVITY AND LATERAL LOAD COMPLIANCE STATEMENT: EXISTING, UNALTERED STRUCTURAL ELEMENTS CARRYING GRAVITY AND LATERAL LOADS, TO THE REST OF OUR KNOWLEDGE AND BELIEF, HAVE NOT BEEN INCREASED GREATER THAN 5 PERCENT, AND THE DEMAND - CAPACITY RATIO FOR EXISTING LATERIAL LOAD - CARRYING STRUCTURAL ELEMENTS HAVE NOT
BEEN INCREASED GREATER THAN 10 PERCENT.
520 FLORIDA PRODUCT APPROVAL
520.1 IN ACCORDANCE WITH THE FLORIDA PRODUCT APPROVAL SYSTEM, MANUFACTURERS OF ROOFING AND ALL STRUCTURAL COMPONENTS THAT AFFECT THE STRUCTURAL INTEGRITY OF BUILDINGS DURING HURRICANES MUST SUBMIT THE FOLLOWING DOCUMENTATIONS TO THE OFFICES OF LONG AND ASSOCIATES FOR REVIEW AND APPROVAL:
1. EVIDENCE THAT THE PRODUCT HAS BEEN EVALUATED FOR COMPLIANCE WITH STANDARDS ESTABLISHED BY THE CURRENT FLORIDA BUILDING CODE BY A FLORIDA BUILDING COMMISSION APPROVED ENTITY OR FLORIDA LICENSED
P.E. OR REGISTERED ARCHITECT.
2. EVIDENCE THAT THE MANUFACTURER HAS CONTRACTED WITH A FLORIDA BUILDING COMMISSION APPROVED QUALITY ASSURANCE ENTITY TO MONITOR MANUFACTURING PRODUCTION AND HAS ACTIVELY COMPLIED OR HAVE
THE PRODUCT LISTED AND LABELED BY A COMMISSION APPROVED CERTIFICATION PROGRAM.
3. INSTALLATION INSTRUCTIONS CONSISTENT WITH THE EVALUATION OF COMPLIANCE.
520.2 PRODUCTS INSTALLED OVER THE STRUCTURAL ROOF DECK SHALL BE TESTED AS AN ASSEMBLY, INCLUSIVE OF THE STRUCTURAL DECK BY AN APPROVED INDEPENDENT TESTING LABORATORY, IN ACCORDANCE WITH ANSI/AAMA/NWWDA 101/IS2 STANDARD AND BEAR AN AAMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND
APPROVED PRODUCT TESTING ENTITY.
520.3 PRODUCTS INSTALLED OVER THE STRUCTURAL ROOF DECK SHALL BE ANCHORED PER PUBLISHED MANUFACTURER'S RECOMMENDATIONS IN ORDER TO SAFELY RESIST THE "MINIMUM COMPONENT AND CLADDING WIND PRESSURES" FOR THE ROOF FIELD, CORNERS AND EDGES, AS APPLICABLE, INDICATED ON THESE DRAWINGS. ANCHORAGE SHALL BE SUBSTANTIATED BY SIGNED, SEALED (EMBOSSED), AND DATED CALCULATIONS PERFORMED BY A STRUCTURAL ENGINEER CURRENTLY REGISTERED IN THE STATE OF FLORIDA. CALCULATIONS SHALL BE SUBMITTED TO THE A/E FOR REVIEW PRIOR TO
FABRICATION OR ERECTION.
STRUCTURAL NOTES
002 GENERAL
002.1 GENERAL NOTES AND TYPICAL DETAILS APPLY TO ALL STRUCTURAL FEATURES UNLESS OTHERWISE SHOWN OR NOTED. IF CERTAIN FEATURES ARE NOT FULLY SHOWN OR CALLED FOR ON THE DRAWINGS OR SPECIFICATIONS, THEIR CONSTRUCTION SHALL
BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS.
002.2 ANCHORS ARE TO BE INSTALLED WITHIN A TOLERANCE OF 1/4" OF SPECIFIED LOCATION.
002.3 A SOIL OR WASTE PIPE OR A BUILDING DRAIN, ETC PASSING UNDER OR THROUGH A FOOTING SHALL BE PROVIDED WITH A RELIEVING ARCH, OR THERE SHALL BE BUILT INTO THE FOUNDATION AN IRON PIPE SLEEVE TWO PIPE SIZES GREATER THAN THE PIPE PASSING THROUGH FOR PIPES 6"ø AND LESS, AND ONE PIPE SIZE GREATER THAN THE PIPE PASSING THROUGH FOR PIPES GREATER THAN 6"ø.
002.4 THIS STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO ENSURE THE SAFETY OF WORKERS, THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, TEMPORARY BRACING, ETC. THAT MAY BE NECESSARY AS WELL AS FULL COMPLIANCE WITH ALL APPLICABLE OSHA REGULATIONS. OBSERVATION VISITS TO THE SITE BY LONG AND ASSOCIATES PERSONAL SHALL NOT INCLUDE INSPECTION FOR THESE ITEMS. ALL TEMPORARY SHORING BY FLORIDA REGISTERED SPECIALTY ENGINEER SHALL BE SUBMITTED TO L&A FOR REVIEW & APPROVAL BY THE PROJECT
STRUCTURAL ENGINEER OF RECORD.
002.5 IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO ENSURE ALL WORK IS PERFORMED IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS.
002.6 DIMENSIONS SHALL NOT BE SCALED.
002.7 CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS RELATIVE TO SAME. WHERE THERE ARE CONFLICTS BETWEEN ACTUAL FIELD CONDITIONS AND/OR DATA PRESENTED ON THESE DRAWINGS, SUCH CONDITIONS SHALL BE CALLED TO THE ATTENTION OF LONG & ASSOCIATES IMMEDIATELY AND NECESSARY ADJUSTMENTS MADE PER THEIR INSTRUCTIONS.
002.8 SPECIALTY ENGINEER REQUIREMENTS: THE FLORIDA BOARD OF PROFESSIONAL ENGINEERS IS ON RECORD STATING THE RESPONSIBILITIES OF PROFESSIONAL ENGINEERS, PURSUANT TO RULE 61G15-31. CERTAIN COMPONENTS OF THIS STRUCTURE REQUIRES THE WORK OF A SPECIALTY ENGINEER. ALL PROCEDURES STATED IN RULE 61G15-31 STATEMENT SHALL APPLY TO THIS
PROJECT.
002.9 SPECIFICATIONS, CODES, AND STANDARDS NOTED IN THESE CONTRACT DOCUMENTS SHALL BE OF THE LATEST EDITION
APPROVED BY THE APPROPRIATE REGULATORY AGENCIES.
002.10 ALL FINISHED GRADE FOR 5FT (MIN) ALONGTHE EDGE OF DISTURBED SLAB-ON-GRADE SHALL SLOPE DOWNWARD NO
GREATER THAN 3% UNLESS OTHERWISE NOTED.
002.11 SHOP DRAWINGS AND CALCULATIONS FOR SHORING AND SPECIALTY ENGINEERED BUILDING ELEMENTS MUST BE SIGNED AND SEALED BY THE CURRENTLY REGISTERED, FLORIDA SPECIALTY ENGINEER RESPONSIBLE FOR THE DESIGN AT TIME OF
SUBMISSION PROVIDED TO L & A FOR REVIEW PRIOR TO ERECTION.
410 FOUNDATION
410.1 DESIGN SOIL BEARING PRESSURE IS 2000 PSF BASED UPON THE FOUNDATION RECOMMENDATIONS CONTAINED IN THE GEOTECHNICAL EXPLORATION REPORT BY PSI DATED JANUARY 19, 1999. WATER SHOULD NOT BE ALLOWED TO POND IN FOUNDATION EXCAVATIONS. CONCRETE FOUNDATIONS SHOULD HAVE REINFORCEMENT AND CONCRETE PLACED THE SAME DAY, ELSE EXCAVATIONS SHOULD BE ADEQUATELY PROTECTED.
410.2 QUALITY ASSURANCE COMPACTION DENSITY UNDER FOOTINGS AND SLABS SHALL BE A MINIMUM OF 98% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D-1557 (MODIFIED PROCTOR) THROUGHOUT. IN ADDITION TO THIS MINIMUM COMPACTION REQUIREMENT, THE BEARING SOILS MUST EXHIBIT STABILITY AND BE FREE OF "PUMPING" CONDITIONS. IMMEDIATELY PRIOR TO REINFORCING STEEL PLACEMENT THE BEARING SURFACES OF ALL FOOTING AND FLOOR SLAB AREAS SHALL BE COMPACTED USING
HAND-OPERATED MECHANICAL TAMPERS.
410.3 FOOTINGS SHALL NOT BE PLACED ABOVE SLOPES EXCEEDING ONE VERTICAL AND TWO HORIZONTAL AS MEASURED FROM
THE CLOSEST EDGE OF ANY UNDISTURBED SOIL OR OTHER FOUNDATION STRUCTURE.
410.4 ALL FOOTINGS SHALL BE CENTERED UNDER COLUMN OR WALL CENTERLINES UNLESS SHOWN OR NOTED OTHERWISE.
410.5 THE CONTRACTOR SHALL PROTECT AND MAINTAIN OPERATION OF ALL UTILITIES ABOVE AND BELOW GRADE UON.
LOCATE EXISTING UNDERGROUND UTILITIES IN AREAS OF EXCAVATION WORK. IF UTILITIES ARE INDICATED TO REMAIN IN PLACE, PROVIDE ADEQUATE MEANS OF SUPPORT AND PROTECTION DURING EARTHWORK OPERATIONS. SHOULD UNCHARTED, OR INCORRECTLY CHARTED, PIPING OR OTHER UTILITIES BE ENCOUNTERED DURING EXCAVATION, DO NOT INTERRUPT EXISTING UTILITIES SERVING FACILITIES OCCUPIED BY OWNER OR OTHERS, DURING OCCUPIED HOURS, EXCEPT WHEN PERMITTED IN WRITING BY L&A AND THEN ONLY AFTER ACCEPTABLE TEMPORARY UTILITY SERVICES HAVE BEEN PROVIDED. PROVIDE MINIMUM OF 48_HOUR NOTICE TO THE OWNER, AND RECEIVE WRITTEN NOTICE TO PROCEED BEFORE INTERRUPTING ANY UTILITY.
410.6 PROTECTION OF PERSONS AND PROPERTY: BARRICADE OPEN EXCAVATIONS OCCURRING AS PART OF THIS WORK AND POST WITH WARNING LIGHTS. OPERATE WARNING LIGHTS AS RECOMMENDED BY AUTHORITIES HAVING JURISDICTION. PROTECT STRUCTURES, UTILITIES, SIDEWALKS, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING, WASHOUT, AND OTHER HAZARDS CREATED BY EARTHWORK OPERATIONS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR MAKING ALL EXCAVATIONS IN A SAFE MANNER. PROVIDE APPROPRIATE MEASURES TO RETAIN EXCAVATION SIDE-SLOPES TO ENSURE THAT PERSONS WORKING IN OR NEAR EXCAVATIONS ARE PROTECTED.
410.7 DEWATERING: PREVENT SURFACE WATER AND GROUND WATER FROM ENTERING EXCAVATIONS, FROM PONDING ON PREPARED SUBGRADES, AND FROM FLOODING PROJECT SITE AND SURROUNDING AREA. PROTECT SUBGRADES FROM SOFTENING, UNDERMINING, WASHOUT, AND DAMAGE BY RAIN OR WATER ACCUMULATION. REROUTE SURFACE WATER RUNOFF AWAY FROM EXCAVATED AREAS. DO NOT ALLOW WATER TO ACCUMULATE IN EXCAVATIONS. INSTALL A DEWATERING SYSTEM TO KEEP SUBGRADES DRY AND CONVEY GROUND WATER AWAY FROM EXCAVATIONS. MAINTAIN UNTIL DEWATERING IS NO LONGER REQUIRED. REMOVE WATER TO PREVENT SOFTENING OF FOUNDATION BOTTOMS, UNDERCUTTING FOOTINGS AND SOIL CHANGES DETRIMENTAL TO STABILITY OF SUBGRADES AND FOUNDATIONS. PROVIDE AND MAINTAIN PUMPS, WELL POINTS, SUMPS, SUCTION AND DISCHARGE LINES, AND OTHER DEWATERING SYSTEM COMPONENTS NECESSARY TO CONVEY WATER AWAY FROM
EXCAVATIONS.
410.8 ENGINEERED FILL: IS TO BE USED FOR COMPACTED FILL AND SHALL BE EVALUATED AND TESTED PRIOR TO PLACEMENT TO DETERMINE IF IT IS SUITABLE. SUITABLE ENGINEERED FILL SHALL BE DEFINED AS A NATURALLY OR ARTIFICIALLY GRADED MIXTURE OF NATURAL OR CRUSHED GRAVEL, CRUSHED STONE, AND NATURAL OR CRUSHED SAND; ASTM D 2940 WITH AT LEAST 90 PERCENT PASSING A 1-1/2 INCH SIEVE…