This document appears to be an attachment, J.07 Attachment J.1 STS Equipment Specification, that outlines the technical requirements for Static Transfer Switches (STS) being acquired under a federal contract opportunity. The attachment provides detailed specifications for the STS equipment, including environmental, general, control, indicator, and communication requirements, as well as specific details for 208V and 480V STS models. The related federal contract opportunity is a solicitation (Solicitation Number: 6973GH-24-R-00060) issued by the Department of Transportation Federal Aviation Administration Franchise Acquisition Services to acquire COTS/NDI STS equipment for National Airspace Systems (NAS) facilities throughout the United States and its territories. The solicitation defines the requirements for project management, configuration management, technical support, test and evaluation, logistics support, training, and quality control for the STS and associated equipment.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J.07
| Attachment J.1 STS Equipment Specification Reference | Specification Section | Compliance Review Designation | Explanation of "D" Deviations, "E" Exceptions and “S” Surpasses | Associated Supported Reference for "C", "D", "E", "S" | Associated Supported Reference Page Number For "C", "D", "E", "S" |
| "C", "D", "E", "S" | |||||
| 1.3 | Environment Requirements | ||||
| 1.3.1 | Storage Temperature | ||||
| 1.3.2 | Operating Temperature | ||||
| 1.3.3 | Relative Humidity | ||||
| 1.3.4 | Operating Altitude | ||||
| 1.3.5 | Audible Noise | ||||
| 1.3.6 | Magnetic Fields | ||||
| 1.3.7 | Seismic | ||||
| 1.3.8 | Radio Frequency (RF) Field | ||||
| 2.1 | General Requirements for all Static Transfer Switches (STS) | ||||
| 2.1.1 | Switch Logic Operation | ||||
| 2.1.1.1 | Input Selection | ||||
| 2.1.1.2 | Voltage Sensing | ||||
| 2.1.1.3 | Transfer Time | ||||
| 2.1.1.4 | Current Sensing | ||||
| 2.1.1.5 | Handling of Fault Conditions | ||||
| 2.1.1.6 | Phase and Neutral Transfer Requirements | ||||
| 2.1.1.7 | Measurement, Decision and Action Circuitry | ||||
| 2.1.1.8 | Set Point Accessibility | ||||
| 2.1.1.9 | Adjustments | ||||
| 2.1.1.9.1 | Phase Angle Difference | ||||
| 2.1.1.9.2 | Overvoltage | ||||
| 2.1.1.9.3 | Undervoltage (Below the Desired Value) | ||||
| 2.1.1.9.4 | Undervoltage (Below the Usable Value) | ||||
| 2.1.1.9.5 | Overload for Source | ||||
| 2.1.1.9.6 | Overload (Failed/Shorted Load) | ||||
| 2.1.1.9.7 | Frequency Detection | ||||
| 2.1.1.9.8 | Re-Transfer Time | ||||
| 2.1.1.9.9 | Out of Phase Trasnfer Delay | ||||
| 2.1.2 | Controls | ||||
| 2.1.2.1 | Lamp Test | ||||
| 2.1.2.2 | Reset Fault Control | ||||
| 2.1.2.3 | Source Selector for Source 1 | ||||
| 2.1.2.4 | Source Selector for Source 2 | ||||
| 2.1.2.5 | Auto Retransfer Selector | ||||
| 2.1.2.6 | Control Enable Key Switch | ||||
| 2.1.2.7 | Reset (Main or Master) | ||||
| 2.1.2.8 | Alarm Silence Switch | ||||
| 2.1.3 | Indicators | ||||
| 2.1.3.1 | Indicator Functions | ||||
| 2.1.3.1.1 | Switch not OK | ||||
| 2.1.3.1.2 | Availability of Source 1 Input | ||||
| 2.1.3.1.3 | Availability of Source 2 Input | ||||
| 2.1.3.1.4 | Load Source 1 | ||||
| 2.1.3.1.5 | Load Source 2 | ||||
| 2.1.3.1.6 | Source 1 is Preferred | ||||
| 2.1.3.1.7 | Source 2 is Preferred | ||||
| 2.1.3.1.8 | Retransfer Enabled Indicator | ||||
| 2.1.3.1.9 | Retransfer Enabled Off Indicator | ||||
| 2.1.3.1.10 | Critical Load Powered Up | ||||
| 2.1.3.2 | Indicator Conditional Response | ||||
| 2.1.3.2.1 | Source Annunicated | ||||
| 2.1.3.2.2 | System Conditions Annunicated | ||||
| 2.1.4 | Communications | ||||
| 2.1.4.1 | Modbus RTU | ||||
| 2.1.4.3 | Auxiliary Contacts | ||||
| 2.1.4.4 | Time | ||||
| 2.1.4.5 | Shunt Trip Capability | ||||
| 2.1.5 | Cooling Requirements | ||||
| 2.1.5.1 | Cooling Media | ||||
| 2.1.5.2 | Fans | ||||
| 2.1.5.3 | Filters | ||||
| 2.1.5.4 | Over Temperature Detection | ||||
| 2.1.5.5 | Convecting Cooling | ||||
| 2.2.3 | Static Transfer Switch (STS), 208 Volt, 3-pole/4-pole, 150 Amp, 250 Amp, 400 Amp, 600 Amp, with Bypass Cabinet, Free Standing | ||||
| 2.2.3.1 | Free Standing Cabinet Physical Requirements | ||||
| 2.2.3.1.1 | Static Transfer Switch with Integral Bypass Cabinet | ||||
| 2.2.3.1.2 | Mechanical Configuration Requirements | ||||
| 2.2.3.1.2.1 | Service Access | ||||
| 2.2.3.1.2.2 | Cable Entry | ||||
| 2.2.3.1.2.4 | Mean-Time-To-Repair | ||||
| 2.2.3.2.1 | Inputs | ||||
| 2.2.3.2.1.1 | Input Voltage | ||||
| 2.2.3.2.1.2 | Input Voltage Operating Range | ||||
| 2.2.3.2.1.3 | Input Voltage Connection | ||||
| 2.2.3.2.1.4 | Neutral Plate Connection | ||||
| 2.2.3.2.1.5 | Frequency | ||||
| 2.2.3.2.1.6 | Input Conductor Ratings | ||||
| 2.2.3.2.2 | Outputs | ||||
| 2.2.3.2.2.1 | Output Voltage | ||||
| 2.2.3.2.2.2 | Output Current | ||||
| 2.2.3.2.2.3 | Overload Capacity | ||||
| 2.2.3.2.2.4 | Inrush | ||||
| 2.2.3.2.2.5 | Fault Clearing | ||||
| 2.2.3.2.2.6 | Voltage Withstand | ||||
| 2.2.3.2.2.7 | Output Conductor Ratings | ||||
| 2.2.3.2.2.8 | Performance | ||||
| 2.2.4 | Static Transfer Switch (STS), 480 Volt, 3-pole/4-pole, 150 Amp, 250 Amp, 400 Amp, 600 Amp, with Bypass Cabinet, Free Standing. | ||||
| 2.2.4.1 | Free Standing Cabinet Physical Requirements | ||||
| 2.2.4.1.1 | Static Transfer Switch with Integral Bypass Cabinet | ||||
| 2.2.4.1.2 | Mechanical Configuration Requirements | ||||
| 2.2.4.1.2.1 | Service Access | ||||
| 2.2.4.1.2.4 | Cable Entry | ||||
| 2.2.4.2 | Electrical Requirements | ||||
| 2.2.4.2.1 | Inputs | ||||
| 2.2.4.2.1.1 | Input Voltage | ||||
| 2.2.4.2.1.2 | Input Voltage Operating Range | ||||
| 2.2.4.2.1.3 | Input Voltage Connection | ||||
| 2.2.4.2.1.4 | Neutral Plate Connection | ||||
| 2.2.4.2.1.5 | Frequency | ||||
| 2.2.4.2.1.6 | Input Conductor Ratings | ||||
| 2.2.4.2.2 | Outputs | ||||
| 2.2.4.2.2.1 | Output Voltage | ||||
| 2.2.4.2.2.2 | Output Current | ||||
| 2.2.4.2.2.3 | Overload Capacity | ||||
| 2.2.4.2.2.4 | Inrush | ||||
| 2.2.4.2.2.5 | Fault Clearing | ||||
| 2.2.4.2.2.6 | Voltage Withstand | ||||
| 2.2.4.2.2.7 | Output Conductor Ratings | ||||
| 2.2.4.2.2.8 | Performance |