Plan Set Summary: Little Crum Creek Stream Restoration
This is a design plan set prepared by Pennoni Associates Inc. for the Borough of Swarthmore, Pennsylvania, detailing the Little Crum Creek Stream Restoration project located at Little Crum Creek Park, 121 Park Avenue, Swarthmore, PA 19081. The project encompasses stream bank restoration and stabilization along approximately 750 linear feet of Little Crum Creek, along with site amenities including new pedestrian pathways. Major work elements include clearing and grubbing; excavation, backfill, and grading; selective tree removal; invasive plant removal; temporary erosion and sediment controls; temporary stream diversion; imbricated riprap installation; coir log and boulder placement for bank stabilization; landscaping with native plantings (including trees, shrubs, plugs, live stakes, and brush mattress materials); porous asphalt and mulch pathways; and site restoration. The plan set, dated November 16, 2026, comprises 14 sheets and includes existing conditions plans, erosion and sediment control plans, site improvement plans, landscaping plans with detailed plant schedules, and construction details. Sealed bids are due electronically through PennBID on December 18, 2026, at 11:00 AM, with a pre-bid site visit encouraged on December 4, 2026, at 10:00 AM at the project restroom vestibule off Cresson Lane.
The project is subject to Pennsylvania Department of Labor and Industry prevailing wage requirements, and successful bidders must provide a performance bond or certified check equal to 100% of the contract value within 20 days of award. Liquidated damages are assessed at $500.00 per calendar day for delays. All bidders must submit unconditional bids accompanied by a certified check or bid bond in the amount of not less than 10% of the bid. Construction specifications reference PennDOT standards, Pennsylvania Conservation District guidelines, and the Pennsylvania Department of Environmental Protection standards for erosion and sediment control. The project involves work within FEMA flood zones and requires coordination with existing utilities, including water, sewer, storm, sanitary, and underground power lines. All complete project documentation is available at no cost through PennBID (www.pennbid.net).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-Little Crum Creek Stream Restoration Contract Specs 2026-03.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-0
1.
dw g
PL
OT
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CM-0001
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF1 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PREPARED FOR:
OWNER/DEVELOPER
BOROUGH OF SWARTHMORE
121 PARK AVENUE
SWARTHMORE, PA 19081
NOVEMBER 2026
LITTLE CRUM CREEK RESTORATION
LOCATION MAP
Scale: 1" = 2000'
N O
R
TH
CALL 1-800-242-1776
CALL BEFORE YOU DIG
BEFORE YOU DIG ANYWHERE IN PENNSYLVANIA
PA. ACT 287 OF 1974 REQUIRES THREE WORKING DAYS
NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR
BLAST PENNSYLVANIA ONE-CALL SYSTEM, INC.
SERIAL NUMBER(S): 20263151098
PREPARED BY:
PENNONI ASSOCIATES INC.
1900 Market Street, Suite 300 Philadelphia, PA 19103 T 215.222.3000 F 215.222.3588
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
LI
TT
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
C O
V E
R S
H E
E T
SITE LOCATION
Sheet List Table Sheet
Number Sheet Title
1 COVER SHEET
2 PROJECT NOTES
3 EXISTING CONDITIONS PLAN
4 EXISTING CONDITIONS PLAN
5 EROSION & SEDIMENT CONTROL AND DEMOLITION PLAN
6 EROSION & SEDIMENT CONTROL AND DEMOLITION PLAN
7 SITE IMPROVEMENT PLAN
8 SITE IMPROVEMENT PLAN
9 LANDSCAPING PLAN
10 LANDSCAPING PLAN
11 LANDSCAPING DETALS
12 CONSTRUCTION DETAILS
13 CONSTRUCTION DETAILS
14 EROSION & SEDIMENT CONTROL DETAILS
cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-0
2.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CM-0002
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
N/A
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF2 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
P R
O
JE
C T
N O
TE
S
SITE PREPARATION AND REMOVAL NOTES
1. A FIELD SURVEY OF THE WORK AREA WAS PERFORMED BY PENNONI
ASSOCIATES IN APRIL 2025. SITE VERTICAL DATUM IS BASED ON NAVD88
VERTICAL DATUM.
2. CONTRACTOR IS RESPONSIBLE FOR LAYOUT OF PROPOSED
IMPROVEMENTS. THE ENGINEER MUST BE NOTIFIED OF ANY
DISCREPANCIES BETWEEN FIELD CONDITIONS AND THIS PLAN WHICH
MAY AFFECT THE LAYOUT OF THE PROPOSED IMPROVEMENTS PRIOR TO
CONSTRUCTION. THE ENGINEER WILL PROVIDE DIRECTION TO RESOLVE
CONFLICTS.
3. NO WORK OR ACTIVITIES SHALL BE PERFORMED BEYOND THE LIMIT OF
WORK LINE.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY AND PROTECTION
OF WORK AREA DURING CONSTRUCTION. WORK AREA MUST BE
SECURELY FENCED AT THE END OF EACH WORK DAY.
5. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL FIELD LOCATE AND
RECORD EXISTING PAVING, SIDEWALK, CURB, UTILITIES OR OTHER
ITEMS IN AND AROUND THE WORK AREA INCLUDING ANY EXISTING
DAMAGE. ENGINEER MUST VERIFY LOCATION AND EXTENT OF DAMAGE.
6. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL EXISTING ITEMS
WITHIN THE WORK AREA NOTED FOR REMOVAL, INCLUDING EXCESS
SOIL. AFTER REMOVALS, CONTRACTOR IS RESPONSIBLE FOR BACKFILL,
COMPACTION, AND RESTORATION OF DISTURBED AREAS.
7. CONTRACTOR SHALL PROTECT ALL UTILITIES, ENTRANCE PADS,
FENCING, SIGNAGE, PLANT MATERIAL, AND OTHER ITEMS TO REMAIN
FROM DAMAGE DURING CONSTRUCTION. THE CONTRACTOR SHALL
REPLACE AND/OR RESTORE DAMAGED OR DISTURBED AREAS AS A
RESULT OF HIS NEGLIGENCE AT NO ADDITIONAL COST TO THE OWNER
TO THE OWNER'S SATISFACTION.
8. ALL DEBRIS SHALL BE REMOVED FROM THE SITE AND LEGALLY
DISPOSED OF BY THE CONTRACTOR ON A DAILY BASIS.
9. ONLY DISTURB AS MUCH AREA AS CAN BE COMPLETED THE SAME DAY.
ALL EXPOSED GRADED AREAS THAT CANNOT BE STABILIZED BY THE END
OF THE WORK DAY OR BEFORE A STORM EVENT (WHICHEVER IS
SOONER), SHALL HAVE TEMPORARY EROSION AND SEDIMENT CONTROL
MEASURES IN PLACE.
UTILITY NOTES
1. CONTRACTOR SHALL VERIFY LOCATIONS AND ELEVATIONS OF EXISTING
UTILITIES ON SITE PRIOR TO COMMENCEMENT OF WORK.
2. ALL EXISTING UTILITIES WITHIN THE WORK AREA ARE TO REMAIN.
LOCATE AND PROTECT FROM DAMAGE DURING CONSTRUCTION.
3. LOCATIONS OF ON AND OFF SITE UTILITIES AS SHOWN ARE
APPROXIMATE AND MAY OR MAY NOT BE COMPLETE. THE NATURE AND
EXACT LOCATION OF EXISTING UTILITIES SHOULD BE VERIFIED PRIOR TO
INITIATING ANY ACTIVITY THAT MAY AFFECT THEIR USE OR LOCATION.
4. THE LOCATION OF THE EXISTING UNDERGROUND UTILITIES SHOWN ON
THIS PLAN HAVE BEEN TAKEN FROM EXISTING UTILITY RECORDS
AVAILABLE AT THE TIME THESE PLANS WERE PREPARED AND FROM
SURFACE OBSERVATION OF THE SITE. COMPLETENESS OR ACCURACY
OF LOCATION AND DEPTH OF UNDERGROUND UTILITIES AND
STRUCTURES IS NOT GUARANTEED. CONTRACTOR IS CAUTIONED THAT
OTHER UTILITIES NOT SHOWN MY EXIST WITHIN THE PROJECT LIMITS.
5. IN ACCORDANCE WITH PA ACT 287 OF 1974 AS AMENDED BY PA ACT 121
OF 2008 ENTITLED "UNDERGROUND UTILITY LINE PROTECTION LAW". THE
CONTRACTOR SHALL NOTIFY ALL UTILITIES WITHIN THE WORK AREA VIA
THE PENNSYLVANIA ONE CALL SYSTEM, INC. (800-242-1776) A MINIMUM
OF 3 WORKING DAYS BEFORE THE START OF EXCAVATION
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND STRUCTURES AND UTILITIES, SUCH AS WATER, SEWER,
TELEPHONE AND ELECTRIC CONDUITS, ETC, AND ABOVE GROUND
UTILITIES, WHICH MAY BE ENCOUNTERED DURING CONSTRUCTION
OPERATIONS. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL
EXISTING UTILITIES.
TREE PROTECTION AND TRIMMING NOTES
1. ALL TREES ON SITE, EXCEPT THOSE NOTED TO BE REMOVED, ARE TO
REMAIN AND BE PROTECTED. AVOID OPERATING HEAVY MACHINERY
WITHIN DRIPLINE OF ALL TREES.
2. INSTALL TREE PROTECTION FENCE AROUND DRIPLINE OF ALL TREES
WITHIN LIMIT OF WORK AREA. FENCE MAY SURROUND GROUPINGS OF
TREES. FENCING SHOWN ON PLANS IS DIAGRAMMATIC AND MUST BE
ADJUSTED TO MEET ACTUAL CONDITIONS.
3. INSTALL TREE PROTECTION FENCE (CONSTRUCTION FENCE) AROUND
THE LIMIT OF WORK AREA AS INDICATED ON THE PLAN AND DETAIL.
4. TREE PROTECTION FENCE MUST BE APPROVED BY THE OWNER'S
REPRESENTATIVE BEFORE CONSTRUCTION ACTIVITIES BEGIN.
CONTRACTOR SHOULD ALLOW TIME FOR MINOR ADJUSTMENTS TO TREE
PROTECTION FENCE LOCATIONS.
5. IN AREAS WHERE TREE PROTECTION FENCING CONFLICTS WITH
PROPOSED WORK, REMOVE TREE PROTECTION FENCING FOR THE DAY
TO PERFORM WORK, AND REPLACE AT END OF DAY.
6. IF TREE ROOTS ARE ENCOUNTERED DURING EXCAVATION, PROPER
ROOT PRUNING MEASURES MUST BE FOLLOWED PER SPECIFICATIONS.
TREE REMOVAL NOTES
1. AT START OF PROJECT, CONTRACTOR SHALL WALK PROJECT AREA WITH
OWNER'S REPRESENTATIVE TO MARK ALL TREES TO BE REMOVED.
REMOVAL SHALL INCLUDE GRINDING OF STUMPS TO 6" BELOW FINISHED
GRADE WHERE REGRADING IS SHOWN. IF LIMITED SHALLOW OR NO
REGRADING IS PROPOSED, THEN STUMP MAY REMAIN IF NOT IN
CONFLICT WITH PROPOSED IMPROVEMENTS. EXACT TREES TO BE
REMOVED MAY BE REVISED BY OWNER'S REPRESENTATIVE AS
REQUIRED PER CONDITIONS AT TIME OF WORK.
GRADING NOTES
1. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION SURVEY AND
LAYOUT OF PROPOSED ELEVATIONS.
2. BENCHMARKS ARE PROVIDED ON DRAWINGS. CONTRACTOR TO
CROSS-CHECK AND VERIFY BENCHMARKS PRIOR TO CONSTRUCTION.
3. TOPSOIL MUST BE REMOVED AND STOCKPILED BEFORE ROUGH
GRADING. EXCAVATED SUBGRADE SOIL MAY BE TEMPORARILY
STOCKPILED SEPARATELY AND MUST BE REMOVED OFFSITE AND
DISPOSED WITHIN 20 DAYS. AFTER ROUGH GRADING, TOPSOIL TO BE
RESPREAD OVER GRADED AREAS.
4. CONTRACTOR IS RESPONSIBLE FOR GRADING PROPOSED GRADES INTO
EXISTING GRADES WITH SMOOTH, EVEN TRANSITIONS, ROUNDING OUT
ALL MOUNDS AND DEPRESSIONS.
5. COIR LOG PLACEMENT: ELEVATIONS SHOWN ARE TOP OF COIR LOG.
COIR LOGS ARE TO BE SLOPED TO FOLLOW WATER ELEVATIONS. THESE
ELEVATIONS MAY BE ADJUSTED IN THE FIELD IF NECESSARY TO MEET
FLOW ELEVATIONS, AS DIRECTED BY OWNER'S REPRESENTATIVE.
CONTRACTOR MUST ALERT OWNER'S REPRESENTATIVE OF COIR LOG
ELEVATIONS NOT MATCHING WATER FLOW BEFORE PLACEMENT OF LOG.
6. BOULDER PLACEMENT: ELEVATIONS SHOWN ARE FOR THE TOP OF
BOULDER. BOULDERS MUST BE PLACED LEVEL AND STEPPED AS
SHOWN. NUMBER OF STACKED BOULDERS IS AS REQUIRED TO PROVIDE
ONE FULL BOULDER (2' MIN) BELOW FINISHED GRADE. SEE BOULDER
DETAIL FOR MORE INFORMATION.
7. AFTER AREAS ARE GRADED, INSTALL SEED, MULCH AND COIR MAT
IMMEDIATELY.
8. EXCESS EARTH CUT MATERIAL, IF ANY, SHALL BECOME THE
RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REMOVED FROM
THE SITE UNLESS OTHERWISE APPROVED TO BE PLACED ON SITE BY
THE OWNER'S REPRESENTATIVE.
EROSION AND SEDIMENT CONTROL MEASURE NOTES
1. ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS
WELL AS CUTS AND FILLS SHALL BE DONE IN ACCORDANCE WITH THE
APPROVED E&S PLAN. A COPY OF THE APPROVED DRAWINGS (STAMPED,
SIGNED AND DATED BY THE REVIEWING AGENCY) MUST BE AVAILABLE
AT THE PROJECT SITE AT ALL TIMES. THE REVIEWING AGENCY SHALL BE
NOTIFIED OF ANY CHANGES TO THE APPROVED PLAN PRIOR TO
IMPLEMENTATION OF THOSE CHANGES. THE REVIEWING AGENCY MAY
REQUIRE A WRITTEN SUBMITTAL OF THOSE CHANGES FOR REVIEW AND
APPROVAL AT ITS DISCRETION.
2. AT LEAST 7 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE
ACTIVITIES, INCLUDING CLEARING AND GRUBBING, THE OWNER AND/OR
OPERATOR SHALL INVITE ALL CONTRACTORS, THE LANDOWNER,
APPROPRIATE MUNICIPAL OFFICIALS, THE E&S PLAN PREPARER, THE
PCSM PLAN PREPARER, THE LICENSED PROFESSIONAL RESPONSIBLE
FOR OVERSIGHT OF CRITICAL STAGES OF IMPLEMENTATION OF THE
PCSM PLAN, AND A REPRESENTATIVE FROM THE LOCAL CONSERVATION
DISTRICT TO AN ON-SITE PRECONSTRUCTION MEETING.
3. AT LEAST 3 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE
ACTIVITIES, OR EXPANDING INTO AN AREA PREVIOUSLY UNMARKED, THE
PENNSYLVANIA ONE CALL SYSTEM INC. SHALL BE NOTIFIED AT
1-800-242-1776 FOR THE LOCATION OF EXISTING UNDERGROUND
UTILITIES.
4. ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE
WITH THE SEQUENCE PROVIDED ON THE PLAN DRAWINGS. DEVIATION
FROM THAT SEQUENCE MUST BE APPROVED IN WRITING FROM THE
LOCAL CONSERVATION DISTRICT OR BY THE DEPARTMENT PRIOR TO
IMPLEMENTATION.
5. AREAS TO BE FILLED ARE TO BE CLEARED, GRUBBED, AND STRIPPED OF
TOPSOIL TO REMOVE TREES, VEGETATION, ROOTS AND OTHER
OBJECTIONABLE MATERIAL.
6. CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO
THOSE AREAS DESCRIBED IN EACH STAGE OF THE CONSTRUCTION
SEQUENCE. GENERAL SITE CLEARING, GRUBBING AND TOPSOIL
STRIPPING MAY NOT COMMENCE IN ANY STAGE OR PHASE OF THE
PROJECT UNTIL THE E&S BMPS SPECIFIED BY THE BMP SEQUENCE FOR
THAT STAGE OR PHASE HAVE BEEN INSTALLED AND ARE FUNCTIONING
AS DESCRIBED IN THIS E&S PLAN.
7. AT NO TIME SHALL CONSTRUCTION VEHICLES BE ALLOWED TO ENTER
AREAS OUTSIDE THE LIMIT OF DISTURBANCE BOUNDARIES SHOWN ON
THE PLAN MAPS. THESE AREAS MUST BE CLEARLY MARKED AND
FENCED OFF BEFORE CLEARING AND GRUBBING OPERATIONS BEGIN.
8. TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF VEGETATION SHALL BE
STOCKPILED AT THE LOCATION(S) SHOWN ON THE PLAN MAPS(S) IN THE
AMOUNT NECESSARY TO COMPLETE THE FINISH GRADING OF ALL
EXPOSED AREAS THAT ARE TO BE STABILIZED BY VEGETATION. EACH
STOCKPILE SHALL BE PROTECTED IN THE MANNER SHOWN ON THE PLAN
DRAWINGS. STOCKPILE HEIGHTS SHALL NOT EXCEED 35 FEET.
STOCKPILE SLOPES SHALL BE 2H:1V OR FLATTER.
9. IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES
POSING THE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT
POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BEST
MANAGEMENT PRACTICES TO MINIMIZE THE POTENTIAL FOR EROSION
AND SEDIMENT POLLUTION AND NOTIFY THE LOCAL CONSERVATION
DISTRICT AND/OR THE REGIONAL OFFICE OF THE DEPARTMENT.
10. ALL BUILDING MATERIALS AND WASTES SHALL BE REMOVED FROM THE
SITE AND RECYCLED OR DISPOSED OF IN ACCORDANCE WITH THE
DEPARTMENT'S SOLID WASTE MANAGEMENT REGULATIONS AT 25 PA.
CODE 260.1 ET SEQ., 271.1, AND 287.1 ET. SEQ. NO BUILDING MATERIALS
OR WASTES OR UNUSED BUILDING MATERIALS SHALL BE BURNED,
BURIED, DUMPED, OR DISCHARGED AT THE SITE.
11. ALL OFF-SITE WASTE AND BORROW AREAS MUST HAVE AN E&S PLAN
APPROVED BY THE LOCAL CONSERVATION DISTRICT OR THE
DEPARTMENT FULLY IMPLEMENTED PRIOR TO BEING ACTIVATED.
12. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL
BROUGHT ON SITE IS CLEAN FILL. FORM FP-001 MUST BE RETAINED BY
THE PROPERTY OWNER FOR ANY FILL MATERIAL AFFECTED BY A SPILL
OR RELEASE OF A REGULATED SUBSTANCE BUT QUALIFYING AS CLEAN
FILL DUE TO ANALYTICAL TESTING.
13. ALL PUMPING OF WATER FROM ANY WORK AREA SHALL BE DONE
ACCORDING TO THE PROCEDURE DESCRIBED IN THIS PLAN, OVER
UNDISTURBED VEGETATED AREAS.
14. VEHICLES AND EQUIPMENT MAY NEITHER ENTER DIRECTLY NOR EXIT
DIRECTLY FROM HARVARD AVENUE.
15. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMPS SHALL
BE MAINTAINED PROPERLY. MAINTENANCE SHALL INCLUDE
INSPECTIONS OF ALL EROSION AND SEDIMENT BMPS AFTER EACH
RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND
REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR,
REPLACEMENT, REGRADING, RESEEDING, REMULCHING AND RENETTING
MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS FAIL TO PERFORM
AS EXPECTED, REPLACEMENT BMPS, OR MODIFICATIONS OF THOSE
INSTALLED WILL BE REQUIRED.
16. A LOG SHOWING DATES THAT E&S BMPS WERE INSPECTED AS WELL AS
ANY DEFICIENCIES FOUND AND THE DATE THEY WERE CORRECTED
SHALL BE MAINTAINED ON THE SITE AND BE MADE AVAILABLE TO
REGULATORY AGENCY OFFICIALS AT THE TIME OF INSPECTION.
17. SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL
BE RETURNED TO THE CONSTRUCTION SITE BY THE END OF EACH WORK
DAY AND DISPOSED IN THE MANNER DESCRIBED IN THIS PLAN. IN NO
CASE SHALL THE SEDIMENT BE WASHED, SHOVELED, OR SWEPT INTO
ANY ROADSIDE DITCH, STORM SEWER, OR SURFACE WATER.
18. ALL SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN THE
MANNER DESCRIBED ON THE PLAN DRAWINGS.
19. AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A
MINIMUM DEPTH OF 3 TO 5 INCHES -- 6 TO 12 INCHES ON COMPACTED
SOILS -- PRIOR TO PLACEMENT OF TOPSOIL. AREAS TO BE VEGETATED
SHALL HAVE A MINIMUM 4 INCHES OF TOPSOIL IN PLACE PRIOR TO
SEEDING AND MULCHING. FILL OUTSLOPES SHALL HAVE A MINIMUM OF 2
INCHES OF TOPSOIL.
20. ALL FILLS SHALL BE COMPACTED AS REQUIRED TO REDUCE EROSION,
SLIPPAGE, SETTLEMENT, SUBSIDENCE OR OTHER RELATED PROBLEMS.
FILL INTENDED TO SUPPORT BUILDINGS, STRUCTURES AND CONDUITS,
ETC. SHALL BE COMPACTED IN ACCORDANCE WITH LOCAL
REQUIREMENTS OR CODES.
21. ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO
EXCEED 9 INCHES IN THICKNESS.
22. FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS,
SOD, OR OTHER FOREIGN OR OBJECTIONABLE MATERIALS THAT WOULD
INTERFERE WITH OR PREVENT CONSTRUCTION OF SATISFACTORY FILLS.
23. FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE
MATERIALS SHALL NOT BE INCORPORATED INTO FILLS.
24. FILL SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES.
25. SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE
HANDLED IN ACCORDANCE WITH THE STANDARD AND SPECIFICATION
FOR SUBSURFACE DRAIN OR OTHER APPROVED METHOD.
26. ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY
UPON REACHING FINISHED GRADE. CUT SLOPES IN COMPETENT
BEDROCK AND ROCK FILLS NEED NOT BE VEGETATED. SEEDED AREAS
WITHIN 50 FEET OF A SURFACE WATER, OR AS OTHERWISE SHOWN ON
THE PLAN DRAWINGS, SHALL BE BLANKETED ACCORDING TO THE
STANDARDS OF THIS PLAN.
27. IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY
AREA OR SUBAREA OF THE PROJECT, THE OPERATOR SHALL STABILIZE
ALL DISTURBED AREAS. DURING NON-GERMINATING MONTHS, MULCH
OR PROTECTIVE BLANKETING SHALL BE APPLIED AS DESCRIBED IN THE
PLAN. AREAS NOT AT FINISHED GRADE, WHICH WILL BE REACTIVATED
WITHIN 1 YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE
TEMPORARY STABILIZATION SPECIFICATIONS. THOSE AREAS WHICH
WILL NOT BE REACTIVATED WITHIN 1 YEAR SHALL BE STABILIZED IN
ACCORDANCE WITH THE PERMANENT STABILIZATION SPECIFICATIONS.
28. PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM,
PERENNIAL 70% VEGETATIVE COVER OR OTHER PERMANENT
NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST
ACCELERATED EROSION. CUT AND FILL SLOPES SHALL BE CAPABLE OF
RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER
MOVEMENTS.
29. E&S BMPS SHALL REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS
TRIBUTARY TO THEM ARE PERMANENTLY STABILIZED OR UNTIL THEY
ARE REPLACED BY ANOTHER BMP APPROVED BY THE LOCAL
CONSERVATION DISTRICT OR THE DEPARTMENT.
30. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND
PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE OWNER
AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION
DISTRICT FOR AN INSPECTION PRIOR TO REMOVAL/CONVERSION OF THE
E&S BMPS.
31. AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY
EROSION AND SEDIMENT BMPS MUST BE REMOVED OR CONVERTED TO
PERMANENT POST CONSTRUCTION STORMWATER MANAGEMENT BMPS.
AREAS DISTURBED DURING REMOVAL OR CONVERSION OF THE BMPS
SHALL BE STABILIZED IMMEDIATELY. IN ORDER TO ENSURE RAPID
REVEGETATION OF DISTURBED AREAS, SUCH REMOVAL/CONVERSIONS
ARE TO BE DONE ONLY DURING THE GERMINATING SEASON.
32. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND
PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE OWNER
AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION
DISTRICT TO SCHEDULE A FINAL INSPECTION.
33. FAILURE TO CORRECTLY INSTALL E&S BMPS, FAILURE TO PREVENT
SEDIMENT-LADEN RUNOFF FROM LEAVING THE CONSTRUCTION SITE, OR
FAILURE TO TAKE IMMEDIATE CORRECTIVE ACTION TO RESOLVE
FAILURE OF E&S BMPS MAY RESULT IN ADMINISTRATIVE, CIVIL, AND/OR
CRIMINAL PENALTIES BEING INSTITUTED BY THE DEPARTMENT AS
DEFINED IN SECTION 602 OF THE PENNSYLVANIA CLEAN STREAMS LAW.
THE CLEAN STREAMS LAW PROVIDES FOR UP TO $10,000 PER DAY IN
CIVIL PENALTIES, UP TO $10,000 IN SUMMARY CRIMINAL PENALTIES, AND
UP TO $25,000 IN MISDEMEANOR CRIMINAL PENALTIES FOR EACH
VIOLATION.
TEMPORARY AND PERMANENT STABILIZATION
1. HAY OR STRAW MULCH MUST BE APPLIED AT 3.0 TONS PER ACRE.
2. MULCH WITH MULCH CONTROL NETTING OR EROSION CONTROL
BLANKETS MUST BE INSTALLED ON ALL SLOPES 3:1 OR STEEPER.
3. STRAW MULCH SHALL BE APPLIED IN LONG STRANDS, NOT CHOPPED OR
FINELY BROKEN.
4. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMP'S MUST
BE MAINTAINED PROPERLY. MAINTENANCE MUST INCLUDE INSPECTIONS
OF ALL EROSION AND SEDIMENT CONTROL BMP'S AFTER EACH RUNOFF
EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL
MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT,
REGARDING, RESEEDING, REMULCHING, AND RENETTING, MUST BE
DONE IMMEDIATELY. IF EROSION AND SEDIMENT CONTROL BMP'S FAIL
TO PERFORM AS EXPECTED, REPLACEMENT BMP'S, OR MODIFICATIONS
TO THOSE INSTALLED WILL BE REQUIRED. E&SPCPM P. 168
5. SEE CS-0501 SERIES PLANS FOR ADDITIONAL INFORMATION.
STREAM DIVERSION NOTES
1. PROPOSED STAGING AND LOCATION OF STREAM DIVERSION MEASURES
ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR MAY PROVIDE AN
ALTERNATE WORK PLAN WITH ADJUSTMENTS TO THE LOCATION,
NUMBER OF STAGES, ETC FOR ENGINEER'S REVIEW AND APPROVAL
PRIOR TO START OF WORK.
2. REFER TO DETAILS ON SHEET CS-8501.
PREPAREDNESS PREVENTION AND CONTINGENCY PLAN
1. THE ONLY POTENTIAL FOR AN ACCIDENTAL DISCHARGE OF CHEMICALS,
OR OTHER HAZARDOUS MATERIALS ARE THOSE ASSOCIATED WITH THE
OPERATION OF EARTH MOVING EQUIPMENT. EQUIPMENT MAY BE
PARKED ON SITE OVERNIGHT AT AREAS WITHIN WORK AREA AND AT
LEAST 20 FEET AWAY FROM ANY STREAM EDGE. IF THERE IS AN
ACCIDENTAL DISCHARGE FROM EARTH MOVING EQUIPMENT THE
CONTRACTOR IS RESPONSIBLE FOR DEPLOYING IMMEDIATE ACTION TO
CONTAIN THE DISCHARGE. WHILE CONTAINING THE DISCHARGE THE
CONTRACTOR WILL CONTACT A LICENSED AND BONDED FIRM TO
CLEANUP AND MITIGATE DISCHARGE.
2. CONTRACTOR WILL HAVE ON SITE A CONTAINMENT KIT WITH AT LEAST A
CONTAINMENT BOOM AND ABSORBENT AT A MINIMUM.
SEQUENCE OF CONSTRUCTION
1. CONDUCT PRECONSTRUCTION MEETING. NOTIFICATION OF START OF
WORK TO PARTIES AND AGENCIES.
2. PLACE PA ONE CALL.
3. REVIEW SUBMITTED PRE-CONSTRUCTION DOCUMENTATION, INCLUDING
FIELD VERIFICATION OF LOCATION AND ELEVATION OF EXISTING
UTILITIES TO REMAIN AND BE PROTECTED.
4. MOBILIZATION OF CONTRACTOR EQUIPMENT AND MATERIALS.
5. INSTALL TEMPORARY CONSTRUCTION ENTRANCE, TREE PROTECTION
FENCING, AND CONSTRUCTION FENCING.
6. INSTALL EROSION AND SEDIMENT CONTROL MEASURES.
7. INSTALL TEMPORARY STREAM CROSSING AS NECESSARY.
8. REMOVAL OF SELECTIVE TREES AND SELECTIVE DEMOLITION.
9. INSTALL TEMPORARY COFFERDAM AND PUMPS FOR APPLICABLE STAGE.
10. CLEARING, GRUBBING, AND DEEP ROTOTILLING OF ALL AREAS BEFORE
GRADING, THEN ROUGH GRADE, FINISH GRADE, SEED, AND STRAW.
INSTALL COIR MAT, WHERE INDICATED. PLACE NEW PLANT MATERIAL.
11. CONSTRUCT INSTREAM IMPROVEMENTS.
12. INSTALL BOULDERS AND/OR COIR LOGS AT EDGE OF STREAM.
13. INSTALL OTHER PARK IMPROVEMENTS, FINISH GRADE, RAKE SMOOTH,
SEED AND STRAW.
14. PLANTED AREAS: INSTALL COIR MAT AND PLANT MATERIAL PER
SPECIFICATIONS.
15. RESTORE SITE.
16. REMOVAL OF ANY DEBRIS.
17. DEMOBILIZATION.
(TEMPORARY) SEED MIX: PENNDOT FORMULA E
% PURE LIVE SEED: 98%
APPLICATION RATE: 10 LBS/1000 SY
FERTILIZER TYPE: 10-10-10
FERTILIZER APP. RATE: 500 LBS/ACRE
LIMING RATE: 1 TON/ACRE
MULCH TYPE: HAY OR STRAW
MULCHING RATE: 3 TONS/ACRE
ADDITIONAL SEEDING: 0.5LB/1000 SY INOCULATED RED/WHITE
CLOVER MIX
(PERMANENT SEED MIX: PENNDOT FORMULA B
FLATTER THAN % PURE LIVE SEED: 98%
3:1 SLOPE) APPLICATION RATE: 21 LBS/1000 SY
FERTILIZER TYPE: 10-20-20
FERTILIZER APP. RATE: 1000 LBS/ACRE
LIMING RATE: 6 TONS/ACRE
MULCH TYPE: HAY OR STRAW
MULCHING RATE: 3 TONS/ACRE
ADDITIONAL SEEDING: 0.5 LB/1000 SY INOCULATED RED/WHITE
CLOVER MIX
(PERMANENT SEED MIX: PENNDOT FORMULA D
3:1 SLOPE OR % PURE LIVE SEED: 98%
STEEPER) APPLICATION RATE: 9 LBS/1000 SY
FERTILIZER TYPE: 10-20-20
FERTILIZER APP. RATE: 1000 LBS/ACRE
LIMING RATE: 6 TONS/ACRE
ANCHOR MATERIAL: FLEXTERRA FLEXIBLE GROWTH MEDIUM
(OR APPROVED EQUAL)
ANCHOR METHOD: HYDRAULICALLY
RATE OF ANCHOR MATERIAL: PER MATERIAL SUPPLIER
TEMPORARY AND PERMANENT SEEDING SPECIFICATIONS :
SPECIFICATIONS: THE DEPARTMENT RECOMMENDS THE USE OF THE PENN
STATE AGRONOMY GUIDE AS THE STANDARD TO USE FOR SELECTION OF
SPECIES, SEED SPECIFICATIONS, MIXTURES, LIMING AND FERTILIZING, TIME
OF SEEDING, AND SEEDING METHODS. SPECIFICATIONS FOR THESE ITEMS
MAY ALSO BE OBTAINED FROM PENNDOT'S PUBLICATION #408, SECTION 80
OR BY CONTACTING THE TOWNSHIP ENGINEER. UPON SELECTION OF A
REFERENCE, THAT REFERENCE MUST BE USED TO PROVIDE ALL
SPECIFICATIONS FOR SEEDING, MULCHING, AND SOIL AMENDMENTS. THE
FOLLOWING SPECIFICATION WILL BE USED FOR THIS PROJECT:
MAINTENANCE OF EROSION AND SEDIMENT CONTROLS :
UNTIL THE SITE ACHIEVES FINAL STABILIZATION, THE PERMITTEE AND COPERMITTEE SHALL ASSURE
THAT THE BEST MANAGEMENT PRACTICES ARE IMPLEMENTED, OPERATED, AND MAINTAINED
PROPERLY AND COMPLETELY. MAINTENANCE SHALL INCLUDE INSPECTIONS OF ALL BEST
MANAGEMENT PRACTICES FACILITIES AND MAINTAIN AND MAKE AVAILABLE TO THE DELAWARE
COUNTY CONSERVATION DISTRICT COMPLETE, WRITTEN INSPECTION LOGS OF ALL THOSE
INSPECTIONS. ALL MAINTENANCE WORK INCLUDING CLEANING, REPAIR, REPLACEMENT,
REGRADING, RESEEDING, AND RESTABILIZATION SHALL BE PERFORMED IMMEDIATELY.
IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL FOR
ACCELERATED EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL IMPLEMENT
APPROPRIATE BEST MANAGEMENT PRACTICES TO ELIMINATE POTENTIAL FOR ACCELERATED
EROSION AND/OR SEDIMENT POLLUTION.
BEFORE INITIATING ANY REVISIONS TO THE APPROVED EROSION AND SEDIMENTATION CONTROL
PLAN OR REVISION TO THE OTHER PLANS WHICH MAY AFFECT THE EFFECTIVENESS OF THE
APPROVED E&S CONTROL PLAN, THE OPERATOR MUST RECEIVE APPROVAL OF THE REVISIONS
FROM THE DELAWARE COUNTY AND CONSERVATION DISTRICT.
UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMP'S MUST BE MAINTAINED PROPERLY.
MAINTENANCE MUST INCLUDE INSPECTIONS OF ALL EROSION AND SEDIMENT CONTROL BMP'S
AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL
MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGARDING, RESEEDING, REMULCHING, AND RENETTING, MUST BE DONE IMMEDIATELY. IF EROSION AND SEDIMENT CONTROL
BMP'S FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMP'S, OR MODIFICATIONS TO THOSE
INSTALLED WILL BE REQUIRED. E&SPCPM P. 168
SEDIMENT REMOVED FROM BMP'S SHALL BE DISPOSED OF IN LANDSCAPE AREAS OUTSIDE OF STEEP
SLOPES, WETLANDS, FLOODPLAINS OR DRAINAGE SWALES AND IMMEDIATELY STABILIZED, OR
PLACED IN TOPSOIL STOCKPILES.
THE OPERATOR SHALL REMOVE FROM THIS SITE, RECYCLE, OR DISPOSE OF ALL BUILDING
MATERIALS AND WASTES IN ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE MANAGEMENT
REGULATIONS AT 25 PA. CODE 260.1 ET SEQ., 271.1 ET SEQ. THE CONTRACTOR SHALL NOT
ILLEGALLY BURY, DUMP, OR DISCHARGE ANY BUILDING MATERIAL OR WASTES AT THIS SITE.
ALL PUMPING OF SEDIMENT LADEN WATER SHALL BE THROUGH A SEDIMENT CONTROL BMP, SUCH
AS A PUMPED WATER FILTER BAG DISCHARGING OVER NON-DISTURBED AREAS.
A COPY OF THE APPROVED EROSION AND SEDIMENTATION CONTROL MUST BE AVAILABLE AT THE
PROJECT SITE AT ALL TIMES.
CRESSON LN
FEMA ZONE X
FEMA ZONE AE
FEMA ZONE XFEMA ZONE AE
FEMA ZONE X
FEMA ZONE AE
FEMA ZONE X
FEMA ZONE AE
FE
M
A
ZO
N E
X
FE
M
A
ZO
N E
AE
MATCHLINE
LANDS N/F
MICHAEL E MATTHEWS / SARAH M
MATTHEWS
200 S SWARTHMORE AVE
APN #43-00-01148-00
LANDS N/F
MARY MCCABE / MATTHEW
MCCABE
1 HARVARD AVE
APN #43-00-00575-00
SWARTHMORE BOROUGH
RESTROOM
RECENTLY
GRADED AREA
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-0
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CM-0201
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF3 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
00 20' 40'
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
E X
IS
TI
N G
C O
N D
IT
IO
N S
P
LA
N
O
R
TH
EXISTING CONTOUR
EXISTING TREE
EXISTING STORM
PIPE
EXISTING CONCRETE
SIDEWALK
APPROXIMATE
PROPERTY LINE
EXISTING HEADWALL
EXISTING BRUSH LINE
EXISTING WETLAND
AREA
EXISTING LEGEND:
EXISTING ASPHALT
EXISTING INLET
EXISTING COMPOSITE
FENCE
EXISTING STORM PIPE
EXISTING SANITARY PIPE
EXISTING UNDERGROUND
POWER LINE
EXISTING STORM
MANHOLE
EXISTING SANITARY
MANHOLE
EXISTING WATER PIPE
YALE
AVENUE
(50 ' W
ID
E)
FEMA ZONE A
E
FEMA ZONE A
FEMA ZONE X
FEMA ZONE AE
MATCHLINE
LANDS N/F
ELIZABETH A LARIN / STEVEN J
LARIN
107 YALE AVE
APN #43-00-01381-01
LANDS N/F
CRAIG STEVE FAVA /
KATHLEEN DOWNES FAVA
109 YALE AVE
APN #43-00-01381-00
LANDS N/F
SWARTHMORE BOROUGH
0 SWARTHMORE AVE
APN #43-00-01145-01
LANDS N/F
MARY MCCABE / MATTHEW
MCCABE
1 HARVARD AVE
APN #43-00-00575-00
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-0
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF4 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
E X
IS
TI
N G
C O
N D
IT
IO
N S
P
LA
R
TH
CM-0202
EXISTING CONTOUR
EXISTING TREE
EXISTING STORM
PIPE
EXISTING CONCRETE
SIDEWALK
APPROXIMATE
PROPERTY LINE
EXISTING HEADWALL
EXISTING BRUSH LINE
EXISTING WETLAND
AREA
EXISTING LEGEND:
EXISTING ASPHALT
EXISTING INLET
EXISTING COMPOSITE
FENCE
EXISTING STORM PIPE
EXISTING SANITARY PIPE
EXISTING UNDERGROUND
POWER LINE
EXISTING STORM
MANHOLE
EXISTING SANITARY
MANHOLE
MATCHLINE
LANDS N/F
MICHAEL E MATTHEWS / SARAH M
MATTHEWS
200 S SWARTHMORE AVE
APN #43-00-01148-00
LANDS N/F
MARY MCCABE / MATTHEW
MCCABE
1 HARVARD AVE
APN #43-00-00575-00
SWARTHMORE BOROUGH
RESTROOM
RECENTLY
GRADED AREA
XX
X
X X X
X
X X X
X
XX
X
XX
X X
X X X
X
XX X
X X X X
X
X X
X X X
X X
X
X
X
X
XX
X
X
X
X
X X
XX
X
SOIL/MATERIAL STOCKPILE AREA. LOCATIONTO BE FIELD CONFIRMED WITH ENGINEER.
INSTALL TEMPORARY COFFER
DAM (TYP.)
X
XX
X
EXISTING PATH TO BE
DEMOLISHED
X
REMOVE LARGE BOULDER
REMOVE, PROTECT, AND MOVE
MESSAGING SIGN ADJACENT
TO PROPOSED PATH
CONTRACTOR SHALL
MAINTAIN AND PROTECT
EXISTING SIDEWALK
TEMPORARY ROCK CONSTRUCTION
ENTRANCE. CONTRACTOR SHALL
MAINTAIN AND PROTECT CURB AND
ROADWAY PAVEMENT
INSTALL TEMPORARY STREAM
DIVERSION PUMP AND DISCHARGE
LINE (LAY FLAT). WITH TEMPORARY
SCOUR PROTECTION (TYP.)
PRIVATE DRIVEWAY SHALL NOT BE
USED BY CONTRACTOR FOR
ACCESS TO WORK AREAS.
PROJECT ACCESS SHALL BE FROM
LITTLE CRUM CREEK PARK ONLY
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-0
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF5 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
R
TH
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
E R
O S
IO
N
S
E D
IM
E
N T
C O
N
TR
O L
A N
D D
E M
O
LI
TI
O
N P
LA
N
LIMIT OF WORK/
LIMIT OF DISTURBANCE LINE
TREE PROTECTION FENCE/
CONSTRUCTION FENCE
ROCK CONSTRUCTION ENTRANCE/
TIRE CLEANING AREA
18 IN SILT FENCE
DEMO AND E&S LEGEND:
TREE TO BE REMOVED
STREAM DIVERSION
DISCHARGE LINE
CM-0501
EXISTING CONTOUR
EXISTING TREE
EXISTING STORM
PIPE
EXISTING CONCRETE
SIDEWALK
APPROXIMATE
PROPERTY LINE
EXISTING HEADWALL
EXISTING BRUSH LINE
EXISTING WETLAND
AREA
EXISTING LEGEND:
EXISTING ASPHALT
EXISTING INLET
EXISTING COMPOSITE
FENCE
EXISTING STORM PIPE
EXISTING SANITARY PIPE
EXISTING UNDERGROUND
POWER LINE
EXISTING STORM
MANHOLE
EXISTING SANITARY
MANHOLE
EXISTING PATH TO BE DEMOLISHED
(50 ' W
ID
E)
MATCHLINE
LANDS N/F
ELIZABETH A LARIN / STEVEN J
LARIN
107 YALE AVE
APN #43-00-01381-01
LANDS N/F
CRAIG STEVE FAVA /
KATHLEEN DOWNES FAVA
109 YALE AVE
APN #43-00-01381-00
LANDS N/F
SWARTHMORE BOROUGH
0 SWARTHMORE AVE
APN #43-00-01145-01
LANDS N/F
MARY MCCABE / MATTHEW
MCCABE
1 HARVARD AVE
APN #43-00-00575-00
X X
XX
X
X
X
X
X
X
XX
X
X
X X
X X
XX
TEMPORARY ROCK CONSTRUCTION
ENTRANCE. CONTRACTOR SHALL
MAINTAIN AND PROTECT CURB,
SIDEWALK, SANITARY MANHOLE AND
ROADWAY PAVEMENT
INSTALL TEMPORARY COFFER
DAM (TYP.)
INSTALL TEMPORARY STREAM DIVERSION PUMP AND
DISCHARGE LINE (LAY FLAT). WITH TEMPORARY
SCOUR PROTECTION (TYP.)
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-0
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF6 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
R
TH
LIMIT OF WORK/
LIMIT OF DISTURBANCE LINE
TREE PROTECTION FENCE/
CONSTRUCTION FENCE
ROCK CONSTRUCTION ENTRANCE/
TIRE CLEANING AREA
18 IN SILT FENCE
DEMO AND E&S LEGEND:
TREE TO BE REMOVED
STREAM DIVERSION
DISCHARGE LINE
LI
TT
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
E R
O S
IO
N
S
E D
IM
E
N T
C O
N
TR
O L
A N
D D
E M
O
LI
TI
O
N P
LA
N
CM-0502
EXISTING CONTOUR
EXISTING TREE
EXISTING STORM
PIPE
EXISTING CONCRETE
SIDEWALK
APPROXIMATE
PROPERTY LINE
EXISTING HEADWALL
EXISTING BRUSH LINE
EXISTING WETLAND
AREA
EXISTING LEGEND:
EXISTING ASPHALT
EXISTING INLET
EXISTING COMPOSITE
FENCE
EXISTING STORM PIPE
EXISTING SANITARY PIPE
EXISTING UNDERGROUND
POWER LINE
EXISTING STORM
MANHOLE
EXISTING SANITARY
MANHOLE
EXISTING PATH TO BE DEMOLISHED
MATCHLINE
LANDS N/F
MICHAEL E MATTHEWS / SARAH M
MATTHEWS
200 S SWARTHMORE AVE
APN #43-00-01148-00
LANDS N/F
MARY MCCABE / MATTHEW
MCCABE
1 HARVARD AVE
APN #43-00-00575-00
SWARTHMORE BOROUGH
RESTROOM
RECENTLY
GRADED AREA
BRANCHPACK
REGRADED AREA
5FT WIDE PARK POROUS
PAVEMENT PATH
(2% MAX CROSS SLOPE)
REFER TO LANDSCAPE
PLANS FOR SLOPE
REGRADING AND
STABILIZATION
BRANCHPACK
REGRADED AREA
99 TW
96 TW
93 BW
93 BW
94 BW
99 TW
98.4
99.5
100.2
100.2
99.5
99.3
99.3
99.4
93.8
93.4
92.6
CLEAR BRANCHES, LOOSE ROCKS, DEBRIS, ETC TOTHE LIMIT NOTED BEHIND AND ALONG INDICATEDIMPROVEMENTS. THEN, BACKFILL, FINISH GRADE WITHTOPSOIL, ANNUAL SEED, AND STRAW. BLEND GRADEINTO EXISTING SLOPE UNLESS NOTED OTHERWISE.REFER TO LANDSCAPE PLANS FOR PLANTING.
PROPOSED J-HOOK TYP.
SEE DETAIL 3/CM-6002
PROPOSED IMBRICATED RIP RAP TYP.
SEE DETAIL 1/CM-6002
PROPOSED COIR LOG TYP.
SEE DETAIL 2/CM-6001
PROPOSED TOE BOULDERS TYP.
SEE DETAIL 2/CM-6002
STREAM ACCESS PATH REFER TO
DETAIL 4/CM6002
CONTINGENCY #1: REPLACE
GABION BASKET WALL IN KIND IF
DAMAGED OR DETERIORATING
RELOCATED
MESSAGING
SIGN
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-1
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF7 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
R
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
S
IT
E
IM
P R
O V
E M
E N
T P
LA
N
EXISTING CONTOUR
EXISTING TREE
EXISTING STORM
PIPE
EXISTING CONCRETE
SIDEWALK
APPROXIMATE
PROPERTY LINE
EXISTING HEADWALL
EXISTING BRUSH LINE
EXISTING WETLAND
AREA
EXISTING LEGEND:
PROPOSED COIR MAT
PROPOSED LIMIT OF COIR MAT
PROPOSED COIR LOG
SITE IMPROVEMENT LEGEND:
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR101
GRADING LEGEND:
EXISTING ASPHALT
EXISTING INLET
EXISTING COMPOSITE
FENCE
PROPOSED POROUS PAVEMENT PATH
CM-1001
EXISTING STORM PIPE
EXISTING SANITARY PIPE
EXISTING UNDERGROUND
POWER LINE
EXISTING STORM
MANHOLE
EXISTING SANITARY
MANHOLE
PROPOSED WOOD CHIP PATH
(50 ' W
ID
E)
MATCHLINE
LANDS N/F
ELIZABETH A LARIN / STEVEN J
LARIN
107 YALE AVE
APN #43-00-01381-01
LANDS N/F
CRAIG STEVE FAVA /
KATHLEEN DOWNES FAVA
109 YALE AVE
APN #43-00-01381-00
LANDS N/F
SWARTHMORE BOROUGH
0 SWARTHMORE AVE
APN #43-00-01145-01
LANDS N/F
MARY MCCABE / MATTHEW
MCCABE
1 HARVARD AVE
APN #43-00-00575-00
91 92
5FT WIDE PARK WOOD CHIP
PATH SEE DETAIL 5/CM6002
92 TW
90 TW
89 BW
89 BW
93.4
92.6
92.6
92.7
92.4
92.5
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-1
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF8 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
R
TH
LI
TT
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
S
IT
E
IM
P R
O V
E M
E N
T P
LA
N
CM-1002
EXISTING CONTOUR
EXISTING TREE
EXISTING STORM
PIPE
EXISTING CONCRETE
SIDEWALK
APPROXIMATE
PROPERTY LINE
EXISTING HEADWALL
EXISTING BRUSH LINE
EXISTING WETLAND
AREA
EXISTING LEGEND:
PROPOSED COIR MAT
PROPOSED LIMIT OF COIR MAT
PROPOSED COIR LOG
SITE IMPROVEMENT LEGEND:
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR101
GRADING LEGEND:
EXISTING ASPHALT
EXISTING INLET
EXISTING COMPOSITE
FENCE
EXISTING STORM PIPE
EXISTING SANITARY PIPE
EXISTING UNDERGROUND
POWER LINE
EXISTING STORM
MANHOLE
EXISTING SANITARY
MANHOLE
EXISTING WATER PIPE
PROPOSED POROUS PAVEMENT PATH
PROPOSED WOOD CHIP PATH
MATCHLINE
LANDS N/F
MICHAEL E MATTHEWS / SARAH M
MATTHEWS
200 S SWARTHMORE AVE
APN #43-00-01148-00
LANDS N/F
MARY MCCABE / MATTHEW
MCCABE
1 HARVARD AVE
APN #43-00-00575-00
SWARTHMORE BOROUGH
BRANCHPACK
REGRADED AREA
5FT WIDE PARK POROUS
PAVEMENT PATH
(2% MAX CROSS SLOPE)
BRANCHPACK
REGRADED AREA
CLEAR BRANCHES, LOOSE ROCKS, DEBRIS, ETC TOTHE LIMIT NOTED BEHIND AND ALONG INDICATEDIMPROVEMENTS. THEN, BACKFILL, FINISH GRADE WITHTOPSOIL, ANNUAL SEED, AND STRAW. BLEND GRADEINTO EXISTING SLOPE UNLESS NOTED OTHERWISE.REFER TO LANDSCAPE PLANS FOR PLANTING.
PROPOSED J-HOOK TYP.
SEE DETAIL 3/CM-6002
CONTINGENCY #1: REPLACE
GABION BASKET WALL IN KIND IF
DAMAGED OR DETERIORATING
RESTROOM
RECENTLY
GRADED AREA
1 PO
1 AR 1 UV
1 UV
1 CTO
1 PO
1 UV
1 QB
1 QB
1 QB
1 CTO
1 BN
1 AR
1 BN
1 NS
1 NS
1 NS
1 LS
1 AR
1 LS
1 LS
1 AC
1 AC
1 AC
1 AC
1 AC
1 CC
1 CC
1 CC
1 CC
1 CC
1 NS
1 HV
1 HV
1 HV
1 HV
1 HV
1 MV
1 MV
1 MV
1 CF
1 CF
1 CF
1 CF
1 AC
1 MV
1 LB
1 LB
1 LB
1 LB 1 CC
1 LB
1 LB
1 LB
1 LB
1 LB
1 LB
1 LB
1 LB
1 LB
4 CO
2 CO
1 CO
1 CO
1 CO
2 CO
1 AS
1 AS
1 AS
1 AS
1 AS
1 LB
1 VD
1 VD
1 VD
1 VD
1 VD
1 VD
1 VD
1 VD
1 CA
1 CA
1 CA
1 CA
1 CA
1 CA
1 CA
1 CAF
1 CAF
1 CAF
1 CAF
1 CAF
1 AS
PROPOSED AREA SEEDED
WITH PA COASTAL PLAIN
PROVINCE RIPARIAN MIX
(ERNMX-273)20 BS/ ACRE WITH
30/LBS COVER CROP
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-2
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF9 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
R
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
LA
N
D S
C A
P
IN
G P
LA
N
COMMON NAMEBOTANICAL NAMEKEY QTY ROOTINITIAL SIZE NOTES
PLANT SCHEDULE - TREES AND SHRUBS
ORNAMENTAL TREES
AC Shadblow Serviceberry Multi-stem8 Amelanchier Canadensis
REMOVAL OF INVASIVE
PLANT NOTES:
1. REMOVAL OF INVASIVE PLANT
SPECIES IN THE WETLANDS MUST
BE DONE BY METHODS THAT DO
NOT DISTURB THE SOIL, EXCEPT
FOR SOIL THAT IS DISTURBED BY
INDIVIDUAL PLANT REMOVAL. SEE
SPECIFICATIONS FOR MORE
INFORMATION AND LIST OF
INVASIVE/EXOTIC PLANT MATERIAL
TO BE IDENTIFIED AND REMOVED. CM-2001
CC
HV
American HornbeamCarpinus Caroliniana #10 Container
WitchhazelHamamelis Virginiana #10-15 Container
BN River Birch Multi-stem3 Betula Nigra
LS 3 SweetgumLiquidambar Styraciflua 2" Cal
MV 4 Sweetbay MagnoliaMagnolia Virginiana #10-15 Container
NS 4 Black GumNyssa Sylvatica 2" Cal
QB 3 Swamp White OakQuercus Bicolor 2" Cal
SHRUBS
AS 7 Smooth AlderAlnus Serrulata #3-5 Container
CAF 6 Sweet PepperbushClethra Alnifolia #3-5 Container
CO 13 ButtonbushCephalanthuis Occidentalis #3-5 Container
CA 8 Silky DogwoodCornus Amomum #3-5 Container
LB 10 SpicebushLindera Benzoin #5 Container
VD 9 Southern ArrowwoodViburnum Denstatum #5 Container
COMMON NAMEBOTANICAL NAMEKEY QTY ROOTSPACING IC
PLANT SCHEDULE - PLUGS/GROUND COVER
Mix A -
AS Common Milkweed 24" O.CTBD Asclepias Syriaca
CXS
NJT
PV
Tussock SedgeCarex Stricta 24" O.C
24" O.C Upper Slopes/Full Sun
SwitchgrassPanicum Virgatum 36" O.C
BB Monarda Fistulosa 24" O.C
CXV Fox Sedge 24" O.C Lower Slopes/Partial Shade
Bee Balm
SS Little BluestemSchizachurium Scoparium 36" O.C
SSA Showy GoldenrodSolidago Speciosa 24" O.C
SNB New York AsterSymphyotrichum Novi-Belgii 24' O.C
VN Veronia Noveboracensis 24" O.C
Plug Partial sun/Mid slope
Plug
Plug
Plug
Plug
Plug
Plug
Plug
Plug
Plug
Upper slopes/ full sun
Lower Slopes/Partial Shade
Mid to lower slopes
Upper Slopes/Full Sun
Upper Slopes/Full Sun
Partial Sun/Mid Slope
Mid to lower slopes
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
COMMON NAMEBOTANICAL NAMEKEY QTY SPACING NOTES
PLANT SCHEDULE - LIVE STAKES (1,300 SF)
Cornus SericeaCS
Silky Dogwood
Cornus Amomum
SD Pussy WillowSalix Discolor
Soak for minimum 24 hours prior to installation, not to
Red Oiser Dogwood
3' O.C Triangular Spacing48CA
3' O.C Triangular Spacing
3' O.C Triangular Spacing exceed 14 days
All live stakes and brush mattress materials shall be harvested from dormant, locally adapted native stock. Species substitutions may be made based on contractor availability with approval of the Engineer.
Install live staking through brush mattress sections at the toe of slope to increase stabilization
BRUSH MATTRESS (1,200 SF)
3' O.C Square SpacingSilky Dogwood31CA
SD 36 Pussy Willow 3' O.C Square Spacing
Cornus Amomum
Salix Discolor
SI 33 Sandbar Willow 3' O.C Square SpacingSalix Interior
SL 33 Shining Willow 3' O.C Square SpacingSalix Lucida 133Total
All live stakes and brush mattress materials shall be harvested from dormant, locally adapted native stock.
Species substitutions may be made based on contractor availability with approval of the Engineer
Install brush mattress and live stakes immediately following earth disturbance. Any portions of the stream bank left exposed at the end of each workday shall be protected with erosion and sediment control measures.
Carex Vulpinoidea
New Jersey TeaCeanothus Americanus
AR Red Maple 2" Cal3 Acer Rubrum
CTO 3 Common HackberryCeltis Occidentalis 2" Cal
PO 3 SycamorePlatanus Occidentalis 2" Cal
UV 3 American ElmUlmus Americana 2" Cal
CF 4 Flowering DogwoodCornus Florida #10 Container
LB 6 SpicebushLindera Benzoin #5-10 Container
Total Plug Qty: 1,500 (Choose at least 7 of 10 species with no single species to exceed 20% (300) of total installed plugs)
Area seeded with Ernst Riparian seed Mix ERNMX-273 20 lbs/ac with 30 lbs/ac covercrop or approved equal (Seasonal dependant, see
SPECIFICATIONS)
LIVE STAKES (350 SF)
CONTINGENCY: LIVE STAKES AND BRUSH MATTRESS
Cornus SericeaCS
Silky Dogwood
Cornus Amomum
SD Pussy WillowSalix Discolor
Soak for minimum 24 hours prior to installation, not to
Red Oiser Dogwood
3' O.C Triangular Spacing13CA
3' O.C Triangular Spacing
3' O.C Triangular Spacing exceed 14 days
COMMON NAMEBOTANICAL NAMEKEY QTY SPACING NOTES
CONTINGENCY NOTES:
1. IF APPROVED, CONTINGENCY ITEM PLACEMENT TO BE FIELD VERIFIED WITH FIELD
INSPECTOR PRIOR TO INSTALLATION.
2. REGRADE/ REESTABLISH ANY INCISED BANKS AS NEEDED. PLACE LIVE STAKES AND BRUSH
MATTRESS ON NEWLY GRADED SLOPES.
3. INSTALL BRUSH MATTRESS AND LIVESTAKES ON ONLY UNVEGETATED SECTIONS OF BANK.
39Total
New York Ironweed
(50 ' W
ID
E)
MATCHLINE
LANDS N/F
ELIZABETH A LARIN / STEVEN J
LARIN
107 YALE AVE
APN #43-00-01381-01
LANDS N/F
CRAIG STEVE FAVA /
KATHLEEN DOWNES FAVA
109 YALE AVE
APN #43-00-01381-00
LANDS N/F
SWARTHMORE BOROUGH
0 SWARTHMORE AVE
APN #43-00-01145-01
LANDS N/F
MARY MCCABE / MATTHEW
MCCABE
1 HARVARD AVE
APN #43-00-00575-00
91 92
5FT WIDE PARK WOOD CHIP
PATH SEE DETAIL 5/CM6002
92 TW
90 TW
89 BW
89 BW
93.4
92.6
92.6
92.7
92.4
92.5
1 PO
1 CTO
1 BN
1 AR
1 NS
1 LS
1 AC
1 AC
1 CC
1 HV
1 CF
1 LB
1 LB
1 LB
2 CO
1 CO
1 CO
1 LB
1 AS
1 VD
1 VD
1 VD
1 CA
1 CAF
1 CAF
1 AS
U:
\A cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-2
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF10 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
R
TH
LI
TT
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
LA
N
D S
C A
P
IN
G P
LA
CM-2002
cc ou nt s\S
W
AT
B\
SW
AT
B0
Lit tle C ru m
C re ek R es to ra tio n\
DE
SI
GN
SH
EE
TS
\C M
-2
1.
TE
D:
4/
/2
1:
P
M, B Y:
La za r L az ov ic
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
B Y
N O
D
A
TE
R E
V
IS
IO
N
S
SWATB00403
1"=20'
LL
2026-11-16
EPJ
SHEET
APPROVED BY
OF11 14
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
A
LL
D
IM
E N
S
IO
N S
M U
S T
B E
V E
R
IF
IE
D
B Y
C O
N
TR
A C
TO
R
A N
D O
W N
E R
M U
S T
B E
N O
TI
FI
E D
O F
A N
Y D
IS
C
R E
P A
N C
IE
S
B E
FO
R
E P
R O
C E
E D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
M ar ke t S tre et , S ui te
Ph ila de lp hi a, P A
T
5.
2.
F
5.
2.
A D
C
LE
C
R U
M C
R E
E K
R E
S
TO
R A
TI
O
N
LI
TT
LE
C R
U M
C R
E E
K P
A R
K
S W
A R
TH
M
O R
E B
O R
O U
G H
, P A
P A
R K
A V
E N
U E
S W
A R
TH
M
O R
E , P
A
B O
R O
U G
H O
F S
W A
R
TH
M O
R E
LA
N
D S
C A
P
IN
G D
E
TA
LS
CM-2003
DEAD AND BROKEN BRANCHES.
PRUNE ONLY TO REMOVE
USE DIGGING FORK NOT SPADE
TO ADJACENT AREAS.
THE BEST APPEARANCE OR RELATIONSHIP
SET PLANTS PLUMB AND FACE TO GIVE
TO PREVENT GLAZING OF SUBGRADE
NOTES:
REMOVE EXCESS SOIL FROM TOP OF
ROOT BALL AND SET TOP OF ROOT BALL
AT FINISHED GRADE OR 1" TO 2" ABOVE
IN POORLY DRAINED SOILS
REMOVE BURLAP FROM TOP 12 OF ROOT BALL
OR WITH CONTAINER PLANTS REMOVE POTS
AND LOOSEN ROOTS AS SPECIFIED
PLANTING SOIL MIX
SET PLANT ON UNDISTURBED SUBGRADE
HARDWOOD MULCH.
3" MIN. SHREDDED
PLANTING SOIL MIX
UNDISTURBED SOIL PLANT CONTAINERIZED
ABOVE ADJACENT GRADE
PERENNIAL 1"-2" PLANTING PIT TO
COMPACT BASE OF
PREVENT SETTLING
PROPOSED
GROUNDCOVER
(SPACING VARIES)
PLANTS (TYP)
MIN. 2' FROM BASE
FINISHED
REMOVE MULCH
GRADE
DO NOT USE TREE WRAP.
FROM TOP 1/2 OF ROOT BALL.
FOLD DOWN AND/OR REMOVE
BURLAP OR WIRE BASKET
THE WIDTH OF THE ROOT BALL
PLANTING PIT TO BE 3 TO 5 TIMES
DEAD AND BROKEN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .