Plan Set Summary: Little Crum Creek Stream Restoration

This is a design plan set prepared by Pennoni Associates Inc. for the Borough of Swarthmore, Pennsylvania, detailing the Little Crum Creek Stream Restoration project located at Little Crum Creek Park, 121 Park Avenue, Swarthmore, PA 19081. The project encompasses stream bank restoration and stabilization along approximately 750 linear feet of Little Crum Creek, along with site amenities including new pedestrian pathways. Major work elements include clearing and grubbing; excavation, backfill, and grading; selective tree removal; invasive plant removal; temporary erosion and sediment controls; temporary stream diversion; imbricated riprap installation; coir log and boulder placement for bank stabilization; landscaping with native plantings (including trees, shrubs, plugs, live stakes, and brush mattress materials); porous asphalt and mulch pathways; and site restoration. The plan set, dated November 16, 2026, comprises 14 sheets and includes existing conditions plans, erosion and sediment control plans, site improvement plans, landscaping plans with detailed plant schedules, and construction details. Sealed bids are due electronically through PennBID on December 18, 2026, at 11:00 AM, with a pre-bid site visit encouraged on December 4, 2026, at 10:00 AM at the project restroom vestibule off Cresson Lane.

The project is subject to Pennsylvania Department of Labor and Industry prevailing wage requirements, and successful bidders must provide a performance bond or certified check equal to 100% of the contract value within 20 days of award. Liquidated damages are assessed at $500.00 per calendar day for delays. All bidders must submit unconditional bids accompanied by a certified check or bid bond in the amount of not less than 10% of the bid. Construction specifications reference PennDOT standards, Pennsylvania Conservation District guidelines, and the Pennsylvania Department of Environmental Protection standards for erosion and sediment control. The project involves work within FEMA flood zones and requires coordination with existing utilities, including water, sewer, storm, sanitary, and underground power lines. All complete project documentation is available at no cost through PennBID (www.pennbid.net).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-0

1.

dw g

PL

OT

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

CM-0001

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF1 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL

INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES

FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES

ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PREPARED FOR:

OWNER/DEVELOPER

BOROUGH OF SWARTHMORE

121 PARK AVENUE

SWARTHMORE, PA 19081

NOVEMBER 2026

LITTLE CRUM CREEK RESTORATION

LOCATION MAP

Scale: 1" = 2000'

N O

R

TH

CALL 1-800-242-1776

CALL BEFORE YOU DIG

BEFORE YOU DIG ANYWHERE IN PENNSYLVANIA

PA. ACT 287 OF 1974 REQUIRES THREE WORKING DAYS

NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR

BLAST PENNSYLVANIA ONE-CALL SYSTEM, INC.

SERIAL NUMBER(S): 20263151098

PREPARED BY:

PENNONI ASSOCIATES INC.

1900 Market Street, Suite 300 Philadelphia, PA 19103 T 215.222.3000 F 215.222.3588

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

LI

TT

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

C O

V E

R S

H E

E T

SITE LOCATION

Sheet List Table Sheet

Number Sheet Title

1 COVER SHEET

2 PROJECT NOTES

3 EXISTING CONDITIONS PLAN

4 EXISTING CONDITIONS PLAN

5 EROSION & SEDIMENT CONTROL AND DEMOLITION PLAN

6 EROSION & SEDIMENT CONTROL AND DEMOLITION PLAN

7 SITE IMPROVEMENT PLAN

8 SITE IMPROVEMENT PLAN

9 LANDSCAPING PLAN

10 LANDSCAPING PLAN

11 LANDSCAPING DETALS

12 CONSTRUCTION DETAILS

13 CONSTRUCTION DETAILS

14 EROSION & SEDIMENT CONTROL DETAILS

cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-0

2.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

CM-0002

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

N/A

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF2 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

P R

O

JE

C T

N O

TE

S

SITE PREPARATION AND REMOVAL NOTES

1. A FIELD SURVEY OF THE WORK AREA WAS PERFORMED BY PENNONI

ASSOCIATES IN APRIL 2025. SITE VERTICAL DATUM IS BASED ON NAVD88

VERTICAL DATUM.

2. CONTRACTOR IS RESPONSIBLE FOR LAYOUT OF PROPOSED

IMPROVEMENTS. THE ENGINEER MUST BE NOTIFIED OF ANY

DISCREPANCIES BETWEEN FIELD CONDITIONS AND THIS PLAN WHICH

MAY AFFECT THE LAYOUT OF THE PROPOSED IMPROVEMENTS PRIOR TO

CONSTRUCTION. THE ENGINEER WILL PROVIDE DIRECTION TO RESOLVE

CONFLICTS.

3. NO WORK OR ACTIVITIES SHALL BE PERFORMED BEYOND THE LIMIT OF

WORK LINE.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY AND PROTECTION

OF WORK AREA DURING CONSTRUCTION. WORK AREA MUST BE

SECURELY FENCED AT THE END OF EACH WORK DAY.

5. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL FIELD LOCATE AND

RECORD EXISTING PAVING, SIDEWALK, CURB, UTILITIES OR OTHER

ITEMS IN AND AROUND THE WORK AREA INCLUDING ANY EXISTING

DAMAGE. ENGINEER MUST VERIFY LOCATION AND EXTENT OF DAMAGE.

6. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL EXISTING ITEMS

WITHIN THE WORK AREA NOTED FOR REMOVAL, INCLUDING EXCESS

SOIL. AFTER REMOVALS, CONTRACTOR IS RESPONSIBLE FOR BACKFILL,

COMPACTION, AND RESTORATION OF DISTURBED AREAS.

7. CONTRACTOR SHALL PROTECT ALL UTILITIES, ENTRANCE PADS,

FENCING, SIGNAGE, PLANT MATERIAL, AND OTHER ITEMS TO REMAIN

FROM DAMAGE DURING CONSTRUCTION. THE CONTRACTOR SHALL

REPLACE AND/OR RESTORE DAMAGED OR DISTURBED AREAS AS A

RESULT OF HIS NEGLIGENCE AT NO ADDITIONAL COST TO THE OWNER

TO THE OWNER'S SATISFACTION.

8. ALL DEBRIS SHALL BE REMOVED FROM THE SITE AND LEGALLY

DISPOSED OF BY THE CONTRACTOR ON A DAILY BASIS.

9. ONLY DISTURB AS MUCH AREA AS CAN BE COMPLETED THE SAME DAY.

ALL EXPOSED GRADED AREAS THAT CANNOT BE STABILIZED BY THE END

OF THE WORK DAY OR BEFORE A STORM EVENT (WHICHEVER IS

SOONER), SHALL HAVE TEMPORARY EROSION AND SEDIMENT CONTROL

MEASURES IN PLACE.

UTILITY NOTES

1. CONTRACTOR SHALL VERIFY LOCATIONS AND ELEVATIONS OF EXISTING

UTILITIES ON SITE PRIOR TO COMMENCEMENT OF WORK.

2. ALL EXISTING UTILITIES WITHIN THE WORK AREA ARE TO REMAIN.

LOCATE AND PROTECT FROM DAMAGE DURING CONSTRUCTION.

3. LOCATIONS OF ON AND OFF SITE UTILITIES AS SHOWN ARE

APPROXIMATE AND MAY OR MAY NOT BE COMPLETE. THE NATURE AND

EXACT LOCATION OF EXISTING UTILITIES SHOULD BE VERIFIED PRIOR TO

INITIATING ANY ACTIVITY THAT MAY AFFECT THEIR USE OR LOCATION.

4. THE LOCATION OF THE EXISTING UNDERGROUND UTILITIES SHOWN ON

THIS PLAN HAVE BEEN TAKEN FROM EXISTING UTILITY RECORDS

AVAILABLE AT THE TIME THESE PLANS WERE PREPARED AND FROM

SURFACE OBSERVATION OF THE SITE. COMPLETENESS OR ACCURACY

OF LOCATION AND DEPTH OF UNDERGROUND UTILITIES AND

STRUCTURES IS NOT GUARANTEED. CONTRACTOR IS CAUTIONED THAT

OTHER UTILITIES NOT SHOWN MY EXIST WITHIN THE PROJECT LIMITS.

5. IN ACCORDANCE WITH PA ACT 287 OF 1974 AS AMENDED BY PA ACT 121

OF 2008 ENTITLED "UNDERGROUND UTILITY LINE PROTECTION LAW". THE

CONTRACTOR SHALL NOTIFY ALL UTILITIES WITHIN THE WORK AREA VIA

THE PENNSYLVANIA ONE CALL SYSTEM, INC. (800-242-1776) A MINIMUM

OF 3 WORKING DAYS BEFORE THE START OF EXCAVATION

6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL

UNDERGROUND STRUCTURES AND UTILITIES, SUCH AS WATER, SEWER,

TELEPHONE AND ELECTRIC CONDUITS, ETC, AND ABOVE GROUND

UTILITIES, WHICH MAY BE ENCOUNTERED DURING CONSTRUCTION

OPERATIONS. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL

EXISTING UTILITIES.

TREE PROTECTION AND TRIMMING NOTES

1. ALL TREES ON SITE, EXCEPT THOSE NOTED TO BE REMOVED, ARE TO

REMAIN AND BE PROTECTED. AVOID OPERATING HEAVY MACHINERY

WITHIN DRIPLINE OF ALL TREES.

2. INSTALL TREE PROTECTION FENCE AROUND DRIPLINE OF ALL TREES

WITHIN LIMIT OF WORK AREA. FENCE MAY SURROUND GROUPINGS OF

TREES. FENCING SHOWN ON PLANS IS DIAGRAMMATIC AND MUST BE

ADJUSTED TO MEET ACTUAL CONDITIONS.

3. INSTALL TREE PROTECTION FENCE (CONSTRUCTION FENCE) AROUND

THE LIMIT OF WORK AREA AS INDICATED ON THE PLAN AND DETAIL.

4. TREE PROTECTION FENCE MUST BE APPROVED BY THE OWNER'S

REPRESENTATIVE BEFORE CONSTRUCTION ACTIVITIES BEGIN.

CONTRACTOR SHOULD ALLOW TIME FOR MINOR ADJUSTMENTS TO TREE

PROTECTION FENCE LOCATIONS.

5. IN AREAS WHERE TREE PROTECTION FENCING CONFLICTS WITH

PROPOSED WORK, REMOVE TREE PROTECTION FENCING FOR THE DAY

TO PERFORM WORK, AND REPLACE AT END OF DAY.

6. IF TREE ROOTS ARE ENCOUNTERED DURING EXCAVATION, PROPER

ROOT PRUNING MEASURES MUST BE FOLLOWED PER SPECIFICATIONS.

TREE REMOVAL NOTES

1. AT START OF PROJECT, CONTRACTOR SHALL WALK PROJECT AREA WITH

OWNER'S REPRESENTATIVE TO MARK ALL TREES TO BE REMOVED.

REMOVAL SHALL INCLUDE GRINDING OF STUMPS TO 6" BELOW FINISHED

GRADE WHERE REGRADING IS SHOWN. IF LIMITED SHALLOW OR NO

REGRADING IS PROPOSED, THEN STUMP MAY REMAIN IF NOT IN

CONFLICT WITH PROPOSED IMPROVEMENTS. EXACT TREES TO BE

REMOVED MAY BE REVISED BY OWNER'S REPRESENTATIVE AS

REQUIRED PER CONDITIONS AT TIME OF WORK.

GRADING NOTES

1. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION SURVEY AND

LAYOUT OF PROPOSED ELEVATIONS.

2. BENCHMARKS ARE PROVIDED ON DRAWINGS. CONTRACTOR TO

CROSS-CHECK AND VERIFY BENCHMARKS PRIOR TO CONSTRUCTION.

3. TOPSOIL MUST BE REMOVED AND STOCKPILED BEFORE ROUGH

GRADING. EXCAVATED SUBGRADE SOIL MAY BE TEMPORARILY

STOCKPILED SEPARATELY AND MUST BE REMOVED OFFSITE AND

DISPOSED WITHIN 20 DAYS. AFTER ROUGH GRADING, TOPSOIL TO BE

RESPREAD OVER GRADED AREAS.

4. CONTRACTOR IS RESPONSIBLE FOR GRADING PROPOSED GRADES INTO

EXISTING GRADES WITH SMOOTH, EVEN TRANSITIONS, ROUNDING OUT

ALL MOUNDS AND DEPRESSIONS.

5. COIR LOG PLACEMENT: ELEVATIONS SHOWN ARE TOP OF COIR LOG.

COIR LOGS ARE TO BE SLOPED TO FOLLOW WATER ELEVATIONS. THESE

ELEVATIONS MAY BE ADJUSTED IN THE FIELD IF NECESSARY TO MEET

FLOW ELEVATIONS, AS DIRECTED BY OWNER'S REPRESENTATIVE.

CONTRACTOR MUST ALERT OWNER'S REPRESENTATIVE OF COIR LOG

ELEVATIONS NOT MATCHING WATER FLOW BEFORE PLACEMENT OF LOG.

6. BOULDER PLACEMENT: ELEVATIONS SHOWN ARE FOR THE TOP OF

BOULDER. BOULDERS MUST BE PLACED LEVEL AND STEPPED AS

SHOWN. NUMBER OF STACKED BOULDERS IS AS REQUIRED TO PROVIDE

ONE FULL BOULDER (2' MIN) BELOW FINISHED GRADE. SEE BOULDER

DETAIL FOR MORE INFORMATION.

7. AFTER AREAS ARE GRADED, INSTALL SEED, MULCH AND COIR MAT

IMMEDIATELY.

8. EXCESS EARTH CUT MATERIAL, IF ANY, SHALL BECOME THE

RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REMOVED FROM

THE SITE UNLESS OTHERWISE APPROVED TO BE PLACED ON SITE BY

THE OWNER'S REPRESENTATIVE.

EROSION AND SEDIMENT CONTROL MEASURE NOTES

1. ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS

WELL AS CUTS AND FILLS SHALL BE DONE IN ACCORDANCE WITH THE

APPROVED E&S PLAN. A COPY OF THE APPROVED DRAWINGS (STAMPED,

SIGNED AND DATED BY THE REVIEWING AGENCY) MUST BE AVAILABLE

AT THE PROJECT SITE AT ALL TIMES. THE REVIEWING AGENCY SHALL BE

NOTIFIED OF ANY CHANGES TO THE APPROVED PLAN PRIOR TO

IMPLEMENTATION OF THOSE CHANGES. THE REVIEWING AGENCY MAY

REQUIRE A WRITTEN SUBMITTAL OF THOSE CHANGES FOR REVIEW AND

APPROVAL AT ITS DISCRETION.

2. AT LEAST 7 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE

ACTIVITIES, INCLUDING CLEARING AND GRUBBING, THE OWNER AND/OR

OPERATOR SHALL INVITE ALL CONTRACTORS, THE LANDOWNER,

APPROPRIATE MUNICIPAL OFFICIALS, THE E&S PLAN PREPARER, THE

PCSM PLAN PREPARER, THE LICENSED PROFESSIONAL RESPONSIBLE

FOR OVERSIGHT OF CRITICAL STAGES OF IMPLEMENTATION OF THE

PCSM PLAN, AND A REPRESENTATIVE FROM THE LOCAL CONSERVATION

DISTRICT TO AN ON-SITE PRECONSTRUCTION MEETING.

3. AT LEAST 3 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE

ACTIVITIES, OR EXPANDING INTO AN AREA PREVIOUSLY UNMARKED, THE

PENNSYLVANIA ONE CALL SYSTEM INC. SHALL BE NOTIFIED AT

1-800-242-1776 FOR THE LOCATION OF EXISTING UNDERGROUND

UTILITIES.

4. ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE

WITH THE SEQUENCE PROVIDED ON THE PLAN DRAWINGS. DEVIATION

FROM THAT SEQUENCE MUST BE APPROVED IN WRITING FROM THE

LOCAL CONSERVATION DISTRICT OR BY THE DEPARTMENT PRIOR TO

IMPLEMENTATION.

5. AREAS TO BE FILLED ARE TO BE CLEARED, GRUBBED, AND STRIPPED OF

TOPSOIL TO REMOVE TREES, VEGETATION, ROOTS AND OTHER

OBJECTIONABLE MATERIAL.

6. CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO

THOSE AREAS DESCRIBED IN EACH STAGE OF THE CONSTRUCTION

SEQUENCE. GENERAL SITE CLEARING, GRUBBING AND TOPSOIL

STRIPPING MAY NOT COMMENCE IN ANY STAGE OR PHASE OF THE

PROJECT UNTIL THE E&S BMPS SPECIFIED BY THE BMP SEQUENCE FOR

THAT STAGE OR PHASE HAVE BEEN INSTALLED AND ARE FUNCTIONING

AS DESCRIBED IN THIS E&S PLAN.

7. AT NO TIME SHALL CONSTRUCTION VEHICLES BE ALLOWED TO ENTER

AREAS OUTSIDE THE LIMIT OF DISTURBANCE BOUNDARIES SHOWN ON

THE PLAN MAPS. THESE AREAS MUST BE CLEARLY MARKED AND

FENCED OFF BEFORE CLEARING AND GRUBBING OPERATIONS BEGIN.

8. TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF VEGETATION SHALL BE

STOCKPILED AT THE LOCATION(S) SHOWN ON THE PLAN MAPS(S) IN THE

AMOUNT NECESSARY TO COMPLETE THE FINISH GRADING OF ALL

EXPOSED AREAS THAT ARE TO BE STABILIZED BY VEGETATION. EACH

STOCKPILE SHALL BE PROTECTED IN THE MANNER SHOWN ON THE PLAN

DRAWINGS. STOCKPILE HEIGHTS SHALL NOT EXCEED 35 FEET.

STOCKPILE SLOPES SHALL BE 2H:1V OR FLATTER.

9. IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES

POSING THE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT

POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BEST

MANAGEMENT PRACTICES TO MINIMIZE THE POTENTIAL FOR EROSION

AND SEDIMENT POLLUTION AND NOTIFY THE LOCAL CONSERVATION

DISTRICT AND/OR THE REGIONAL OFFICE OF THE DEPARTMENT.

10. ALL BUILDING MATERIALS AND WASTES SHALL BE REMOVED FROM THE

SITE AND RECYCLED OR DISPOSED OF IN ACCORDANCE WITH THE

DEPARTMENT'S SOLID WASTE MANAGEMENT REGULATIONS AT 25 PA.

CODE 260.1 ET SEQ., 271.1, AND 287.1 ET. SEQ. NO BUILDING MATERIALS

OR WASTES OR UNUSED BUILDING MATERIALS SHALL BE BURNED,

BURIED, DUMPED, OR DISCHARGED AT THE SITE.

11. ALL OFF-SITE WASTE AND BORROW AREAS MUST HAVE AN E&S PLAN

APPROVED BY THE LOCAL CONSERVATION DISTRICT OR THE

DEPARTMENT FULLY IMPLEMENTED PRIOR TO BEING ACTIVATED.

12. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL

BROUGHT ON SITE IS CLEAN FILL. FORM FP-001 MUST BE RETAINED BY

THE PROPERTY OWNER FOR ANY FILL MATERIAL AFFECTED BY A SPILL

OR RELEASE OF A REGULATED SUBSTANCE BUT QUALIFYING AS CLEAN

FILL DUE TO ANALYTICAL TESTING.

13. ALL PUMPING OF WATER FROM ANY WORK AREA SHALL BE DONE

ACCORDING TO THE PROCEDURE DESCRIBED IN THIS PLAN, OVER

UNDISTURBED VEGETATED AREAS.

14. VEHICLES AND EQUIPMENT MAY NEITHER ENTER DIRECTLY NOR EXIT

DIRECTLY FROM HARVARD AVENUE.

15. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMPS SHALL

BE MAINTAINED PROPERLY. MAINTENANCE SHALL INCLUDE

INSPECTIONS OF ALL EROSION AND SEDIMENT BMPS AFTER EACH

RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND

REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR,

REPLACEMENT, REGRADING, RESEEDING, REMULCHING AND RENETTING

MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS FAIL TO PERFORM

AS EXPECTED, REPLACEMENT BMPS, OR MODIFICATIONS OF THOSE

INSTALLED WILL BE REQUIRED.

16. A LOG SHOWING DATES THAT E&S BMPS WERE INSPECTED AS WELL AS

ANY DEFICIENCIES FOUND AND THE DATE THEY WERE CORRECTED

SHALL BE MAINTAINED ON THE SITE AND BE MADE AVAILABLE TO

REGULATORY AGENCY OFFICIALS AT THE TIME OF INSPECTION.

17. SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL

BE RETURNED TO THE CONSTRUCTION SITE BY THE END OF EACH WORK

DAY AND DISPOSED IN THE MANNER DESCRIBED IN THIS PLAN. IN NO

CASE SHALL THE SEDIMENT BE WASHED, SHOVELED, OR SWEPT INTO

ANY ROADSIDE DITCH, STORM SEWER, OR SURFACE WATER.

18. ALL SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN THE

MANNER DESCRIBED ON THE PLAN DRAWINGS.

19. AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A

MINIMUM DEPTH OF 3 TO 5 INCHES -- 6 TO 12 INCHES ON COMPACTED

SOILS -- PRIOR TO PLACEMENT OF TOPSOIL. AREAS TO BE VEGETATED

SHALL HAVE A MINIMUM 4 INCHES OF TOPSOIL IN PLACE PRIOR TO

SEEDING AND MULCHING. FILL OUTSLOPES SHALL HAVE A MINIMUM OF 2

INCHES OF TOPSOIL.

20. ALL FILLS SHALL BE COMPACTED AS REQUIRED TO REDUCE EROSION,

SLIPPAGE, SETTLEMENT, SUBSIDENCE OR OTHER RELATED PROBLEMS.

FILL INTENDED TO SUPPORT BUILDINGS, STRUCTURES AND CONDUITS,

ETC. SHALL BE COMPACTED IN ACCORDANCE WITH LOCAL

REQUIREMENTS OR CODES.

21. ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO

EXCEED 9 INCHES IN THICKNESS.

22. FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS,

SOD, OR OTHER FOREIGN OR OBJECTIONABLE MATERIALS THAT WOULD

INTERFERE WITH OR PREVENT CONSTRUCTION OF SATISFACTORY FILLS.

23. FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE

MATERIALS SHALL NOT BE INCORPORATED INTO FILLS.

24. FILL SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES.

25. SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE

HANDLED IN ACCORDANCE WITH THE STANDARD AND SPECIFICATION

FOR SUBSURFACE DRAIN OR OTHER APPROVED METHOD.

26. ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY

UPON REACHING FINISHED GRADE. CUT SLOPES IN COMPETENT

BEDROCK AND ROCK FILLS NEED NOT BE VEGETATED. SEEDED AREAS

WITHIN 50 FEET OF A SURFACE WATER, OR AS OTHERWISE SHOWN ON

THE PLAN DRAWINGS, SHALL BE BLANKETED ACCORDING TO THE

STANDARDS OF THIS PLAN.

27. IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY

AREA OR SUBAREA OF THE PROJECT, THE OPERATOR SHALL STABILIZE

ALL DISTURBED AREAS. DURING NON-GERMINATING MONTHS, MULCH

OR PROTECTIVE BLANKETING SHALL BE APPLIED AS DESCRIBED IN THE

PLAN. AREAS NOT AT FINISHED GRADE, WHICH WILL BE REACTIVATED

WITHIN 1 YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE

TEMPORARY STABILIZATION SPECIFICATIONS. THOSE AREAS WHICH

WILL NOT BE REACTIVATED WITHIN 1 YEAR SHALL BE STABILIZED IN

ACCORDANCE WITH THE PERMANENT STABILIZATION SPECIFICATIONS.

28. PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM,

PERENNIAL 70% VEGETATIVE COVER OR OTHER PERMANENT

NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST

ACCELERATED EROSION. CUT AND FILL SLOPES SHALL BE CAPABLE OF

RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER

MOVEMENTS.

29. E&S BMPS SHALL REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS

TRIBUTARY TO THEM ARE PERMANENTLY STABILIZED OR UNTIL THEY

ARE REPLACED BY ANOTHER BMP APPROVED BY THE LOCAL

CONSERVATION DISTRICT OR THE DEPARTMENT.

30. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND

PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE OWNER

AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION

DISTRICT FOR AN INSPECTION PRIOR TO REMOVAL/CONVERSION OF THE

E&S BMPS.

31. AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY

EROSION AND SEDIMENT BMPS MUST BE REMOVED OR CONVERTED TO

PERMANENT POST CONSTRUCTION STORMWATER MANAGEMENT BMPS.

AREAS DISTURBED DURING REMOVAL OR CONVERSION OF THE BMPS

SHALL BE STABILIZED IMMEDIATELY. IN ORDER TO ENSURE RAPID

REVEGETATION OF DISTURBED AREAS, SUCH REMOVAL/CONVERSIONS

ARE TO BE DONE ONLY DURING THE GERMINATING SEASON.

32. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND

PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE OWNER

AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION

DISTRICT TO SCHEDULE A FINAL INSPECTION.

33. FAILURE TO CORRECTLY INSTALL E&S BMPS, FAILURE TO PREVENT

SEDIMENT-LADEN RUNOFF FROM LEAVING THE CONSTRUCTION SITE, OR

FAILURE TO TAKE IMMEDIATE CORRECTIVE ACTION TO RESOLVE

FAILURE OF E&S BMPS MAY RESULT IN ADMINISTRATIVE, CIVIL, AND/OR

CRIMINAL PENALTIES BEING INSTITUTED BY THE DEPARTMENT AS

DEFINED IN SECTION 602 OF THE PENNSYLVANIA CLEAN STREAMS LAW.

THE CLEAN STREAMS LAW PROVIDES FOR UP TO $10,000 PER DAY IN

CIVIL PENALTIES, UP TO $10,000 IN SUMMARY CRIMINAL PENALTIES, AND

UP TO $25,000 IN MISDEMEANOR CRIMINAL PENALTIES FOR EACH

VIOLATION.

TEMPORARY AND PERMANENT STABILIZATION

1. HAY OR STRAW MULCH MUST BE APPLIED AT 3.0 TONS PER ACRE.

2. MULCH WITH MULCH CONTROL NETTING OR EROSION CONTROL

BLANKETS MUST BE INSTALLED ON ALL SLOPES 3:1 OR STEEPER.

3. STRAW MULCH SHALL BE APPLIED IN LONG STRANDS, NOT CHOPPED OR

FINELY BROKEN.

4. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMP'S MUST

BE MAINTAINED PROPERLY. MAINTENANCE MUST INCLUDE INSPECTIONS

OF ALL EROSION AND SEDIMENT CONTROL BMP'S AFTER EACH RUNOFF

EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL

MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT,

REGARDING, RESEEDING, REMULCHING, AND RENETTING, MUST BE

DONE IMMEDIATELY. IF EROSION AND SEDIMENT CONTROL BMP'S FAIL

TO PERFORM AS EXPECTED, REPLACEMENT BMP'S, OR MODIFICATIONS

TO THOSE INSTALLED WILL BE REQUIRED. E&SPCPM P. 168

5. SEE CS-0501 SERIES PLANS FOR ADDITIONAL INFORMATION.

STREAM DIVERSION NOTES

1. PROPOSED STAGING AND LOCATION OF STREAM DIVERSION MEASURES

ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR MAY PROVIDE AN

ALTERNATE WORK PLAN WITH ADJUSTMENTS TO THE LOCATION,

NUMBER OF STAGES, ETC FOR ENGINEER'S REVIEW AND APPROVAL

PRIOR TO START OF WORK.

2. REFER TO DETAILS ON SHEET CS-8501.

PREPAREDNESS PREVENTION AND CONTINGENCY PLAN

1. THE ONLY POTENTIAL FOR AN ACCIDENTAL DISCHARGE OF CHEMICALS,

OR OTHER HAZARDOUS MATERIALS ARE THOSE ASSOCIATED WITH THE

OPERATION OF EARTH MOVING EQUIPMENT. EQUIPMENT MAY BE

PARKED ON SITE OVERNIGHT AT AREAS WITHIN WORK AREA AND AT

LEAST 20 FEET AWAY FROM ANY STREAM EDGE. IF THERE IS AN

ACCIDENTAL DISCHARGE FROM EARTH MOVING EQUIPMENT THE

CONTRACTOR IS RESPONSIBLE FOR DEPLOYING IMMEDIATE ACTION TO

CONTAIN THE DISCHARGE. WHILE CONTAINING THE DISCHARGE THE

CONTRACTOR WILL CONTACT A LICENSED AND BONDED FIRM TO

CLEANUP AND MITIGATE DISCHARGE.

2. CONTRACTOR WILL HAVE ON SITE A CONTAINMENT KIT WITH AT LEAST A

CONTAINMENT BOOM AND ABSORBENT AT A MINIMUM.

SEQUENCE OF CONSTRUCTION

1. CONDUCT PRECONSTRUCTION MEETING. NOTIFICATION OF START OF

WORK TO PARTIES AND AGENCIES.

2. PLACE PA ONE CALL.

3. REVIEW SUBMITTED PRE-CONSTRUCTION DOCUMENTATION, INCLUDING

FIELD VERIFICATION OF LOCATION AND ELEVATION OF EXISTING

UTILITIES TO REMAIN AND BE PROTECTED.

4. MOBILIZATION OF CONTRACTOR EQUIPMENT AND MATERIALS.

5. INSTALL TEMPORARY CONSTRUCTION ENTRANCE, TREE PROTECTION

FENCING, AND CONSTRUCTION FENCING.

6. INSTALL EROSION AND SEDIMENT CONTROL MEASURES.

7. INSTALL TEMPORARY STREAM CROSSING AS NECESSARY.

8. REMOVAL OF SELECTIVE TREES AND SELECTIVE DEMOLITION.

9. INSTALL TEMPORARY COFFERDAM AND PUMPS FOR APPLICABLE STAGE.

10. CLEARING, GRUBBING, AND DEEP ROTOTILLING OF ALL AREAS BEFORE

GRADING, THEN ROUGH GRADE, FINISH GRADE, SEED, AND STRAW.

INSTALL COIR MAT, WHERE INDICATED. PLACE NEW PLANT MATERIAL.

11. CONSTRUCT INSTREAM IMPROVEMENTS.

12. INSTALL BOULDERS AND/OR COIR LOGS AT EDGE OF STREAM.

13. INSTALL OTHER PARK IMPROVEMENTS, FINISH GRADE, RAKE SMOOTH,

SEED AND STRAW.

14. PLANTED AREAS: INSTALL COIR MAT AND PLANT MATERIAL PER

SPECIFICATIONS.

15. RESTORE SITE.

16. REMOVAL OF ANY DEBRIS.

17. DEMOBILIZATION.

(TEMPORARY) SEED MIX: PENNDOT FORMULA E

% PURE LIVE SEED: 98%

APPLICATION RATE: 10 LBS/1000 SY

FERTILIZER TYPE: 10-10-10

FERTILIZER APP. RATE: 500 LBS/ACRE

LIMING RATE: 1 TON/ACRE

MULCH TYPE: HAY OR STRAW

MULCHING RATE: 3 TONS/ACRE

ADDITIONAL SEEDING: 0.5LB/1000 SY INOCULATED RED/WHITE

CLOVER MIX

(PERMANENT SEED MIX: PENNDOT FORMULA B

FLATTER THAN % PURE LIVE SEED: 98%

3:1 SLOPE) APPLICATION RATE: 21 LBS/1000 SY

FERTILIZER TYPE: 10-20-20

FERTILIZER APP. RATE: 1000 LBS/ACRE

LIMING RATE: 6 TONS/ACRE

MULCH TYPE: HAY OR STRAW

MULCHING RATE: 3 TONS/ACRE

ADDITIONAL SEEDING: 0.5 LB/1000 SY INOCULATED RED/WHITE

CLOVER MIX

(PERMANENT SEED MIX: PENNDOT FORMULA D

3:1 SLOPE OR % PURE LIVE SEED: 98%

STEEPER) APPLICATION RATE: 9 LBS/1000 SY

FERTILIZER TYPE: 10-20-20

FERTILIZER APP. RATE: 1000 LBS/ACRE

LIMING RATE: 6 TONS/ACRE

ANCHOR MATERIAL: FLEXTERRA FLEXIBLE GROWTH MEDIUM

(OR APPROVED EQUAL)

ANCHOR METHOD: HYDRAULICALLY

RATE OF ANCHOR MATERIAL: PER MATERIAL SUPPLIER

TEMPORARY AND PERMANENT SEEDING SPECIFICATIONS :

SPECIFICATIONS: THE DEPARTMENT RECOMMENDS THE USE OF THE PENN

STATE AGRONOMY GUIDE AS THE STANDARD TO USE FOR SELECTION OF

SPECIES, SEED SPECIFICATIONS, MIXTURES, LIMING AND FERTILIZING, TIME

OF SEEDING, AND SEEDING METHODS. SPECIFICATIONS FOR THESE ITEMS

MAY ALSO BE OBTAINED FROM PENNDOT'S PUBLICATION #408, SECTION 80

OR BY CONTACTING THE TOWNSHIP ENGINEER. UPON SELECTION OF A

REFERENCE, THAT REFERENCE MUST BE USED TO PROVIDE ALL

SPECIFICATIONS FOR SEEDING, MULCHING, AND SOIL AMENDMENTS. THE

FOLLOWING SPECIFICATION WILL BE USED FOR THIS PROJECT:

MAINTENANCE OF EROSION AND SEDIMENT CONTROLS :

UNTIL THE SITE ACHIEVES FINAL STABILIZATION, THE PERMITTEE AND COPERMITTEE SHALL ASSURE

THAT THE BEST MANAGEMENT PRACTICES ARE IMPLEMENTED, OPERATED, AND MAINTAINED

PROPERLY AND COMPLETELY. MAINTENANCE SHALL INCLUDE INSPECTIONS OF ALL BEST

MANAGEMENT PRACTICES FACILITIES AND MAINTAIN AND MAKE AVAILABLE TO THE DELAWARE

COUNTY CONSERVATION DISTRICT COMPLETE, WRITTEN INSPECTION LOGS OF ALL THOSE

INSPECTIONS. ALL MAINTENANCE WORK INCLUDING CLEANING, REPAIR, REPLACEMENT,

REGRADING, RESEEDING, AND RESTABILIZATION SHALL BE PERFORMED IMMEDIATELY.

IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL FOR

ACCELERATED EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL IMPLEMENT

APPROPRIATE BEST MANAGEMENT PRACTICES TO ELIMINATE POTENTIAL FOR ACCELERATED

EROSION AND/OR SEDIMENT POLLUTION.

BEFORE INITIATING ANY REVISIONS TO THE APPROVED EROSION AND SEDIMENTATION CONTROL

PLAN OR REVISION TO THE OTHER PLANS WHICH MAY AFFECT THE EFFECTIVENESS OF THE

APPROVED E&S CONTROL PLAN, THE OPERATOR MUST RECEIVE APPROVAL OF THE REVISIONS

FROM THE DELAWARE COUNTY AND CONSERVATION DISTRICT.

UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMP'S MUST BE MAINTAINED PROPERLY.

MAINTENANCE MUST INCLUDE INSPECTIONS OF ALL EROSION AND SEDIMENT CONTROL BMP'S

AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL

MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGARDING, RESEEDING, REMULCHING, AND RENETTING, MUST BE DONE IMMEDIATELY. IF EROSION AND SEDIMENT CONTROL

BMP'S FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMP'S, OR MODIFICATIONS TO THOSE

INSTALLED WILL BE REQUIRED. E&SPCPM P. 168

SEDIMENT REMOVED FROM BMP'S SHALL BE DISPOSED OF IN LANDSCAPE AREAS OUTSIDE OF STEEP

SLOPES, WETLANDS, FLOODPLAINS OR DRAINAGE SWALES AND IMMEDIATELY STABILIZED, OR

PLACED IN TOPSOIL STOCKPILES.

THE OPERATOR SHALL REMOVE FROM THIS SITE, RECYCLE, OR DISPOSE OF ALL BUILDING

MATERIALS AND WASTES IN ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE MANAGEMENT

REGULATIONS AT 25 PA. CODE 260.1 ET SEQ., 271.1 ET SEQ. THE CONTRACTOR SHALL NOT

ILLEGALLY BURY, DUMP, OR DISCHARGE ANY BUILDING MATERIAL OR WASTES AT THIS SITE.

ALL PUMPING OF SEDIMENT LADEN WATER SHALL BE THROUGH A SEDIMENT CONTROL BMP, SUCH

AS A PUMPED WATER FILTER BAG DISCHARGING OVER NON-DISTURBED AREAS.

A COPY OF THE APPROVED EROSION AND SEDIMENTATION CONTROL MUST BE AVAILABLE AT THE

PROJECT SITE AT ALL TIMES.

CRESSON LN

FEMA ZONE X

FEMA ZONE AE

FEMA ZONE XFEMA ZONE AE

FEMA ZONE X

FEMA ZONE AE

FEMA ZONE X

FEMA ZONE AE

FE

M

A

ZO

N E

X

FE

M

A

ZO

N E

AE

MATCHLINE

LANDS N/F

MICHAEL E MATTHEWS / SARAH M

MATTHEWS

200 S SWARTHMORE AVE

APN #43-00-01148-00

LANDS N/F

MARY MCCABE / MATTHEW

MCCABE

1 HARVARD AVE

APN #43-00-00575-00

SWARTHMORE BOROUGH

RESTROOM

RECENTLY

GRADED AREA

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-0

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

CM-0201

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF3 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

00 20' 40'

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

E X

IS

TI

N G

C O

N D

IT

IO

N S

P

LA

N

O

R

TH

EXISTING CONTOUR

EXISTING TREE

EXISTING STORM

PIPE

EXISTING CONCRETE

SIDEWALK

APPROXIMATE

PROPERTY LINE

EXISTING HEADWALL

EXISTING BRUSH LINE

EXISTING WETLAND

AREA

EXISTING LEGEND:

EXISTING ASPHALT

EXISTING INLET

EXISTING COMPOSITE

FENCE

EXISTING STORM PIPE

EXISTING SANITARY PIPE

EXISTING UNDERGROUND

POWER LINE

EXISTING STORM

MANHOLE

EXISTING SANITARY

MANHOLE

EXISTING WATER PIPE

YALE

AVENUE

(50 ' W

ID

E)

FEMA ZONE A

E

FEMA ZONE A

FEMA ZONE X

FEMA ZONE AE

MATCHLINE

LANDS N/F

ELIZABETH A LARIN / STEVEN J

LARIN

107 YALE AVE

APN #43-00-01381-01

LANDS N/F

CRAIG STEVE FAVA /

KATHLEEN DOWNES FAVA

109 YALE AVE

APN #43-00-01381-00

LANDS N/F

SWARTHMORE BOROUGH

0 SWARTHMORE AVE

APN #43-00-01145-01

LANDS N/F

MARY MCCABE / MATTHEW

MCCABE

1 HARVARD AVE

APN #43-00-00575-00

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-0

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF4 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

E X

IS

TI

N G

C O

N D

IT

IO

N S

P

LA

R

TH

CM-0202

EXISTING CONTOUR

EXISTING TREE

EXISTING STORM

PIPE

EXISTING CONCRETE

SIDEWALK

APPROXIMATE

PROPERTY LINE

EXISTING HEADWALL

EXISTING BRUSH LINE

EXISTING WETLAND

AREA

EXISTING LEGEND:

EXISTING ASPHALT

EXISTING INLET

EXISTING COMPOSITE

FENCE

EXISTING STORM PIPE

EXISTING SANITARY PIPE

EXISTING UNDERGROUND

POWER LINE

EXISTING STORM

MANHOLE

EXISTING SANITARY

MANHOLE

MATCHLINE

LANDS N/F

MICHAEL E MATTHEWS / SARAH M

MATTHEWS

200 S SWARTHMORE AVE

APN #43-00-01148-00

LANDS N/F

MARY MCCABE / MATTHEW

MCCABE

1 HARVARD AVE

APN #43-00-00575-00

SWARTHMORE BOROUGH

RESTROOM

RECENTLY

GRADED AREA

XX

X

X X X

X

X X X

X

XX

X

XX

X X

X X X

X

XX X

X X X X

X

X X

X X X

X X

X

X

X

X

XX

X

X

X

X

X X

XX

X

SOIL/MATERIAL STOCKPILE AREA. LOCATIONTO BE FIELD CONFIRMED WITH ENGINEER.

INSTALL TEMPORARY COFFER

DAM (TYP.)

X

XX

X

EXISTING PATH TO BE

DEMOLISHED

X

REMOVE LARGE BOULDER

REMOVE, PROTECT, AND MOVE

MESSAGING SIGN ADJACENT

TO PROPOSED PATH

CONTRACTOR SHALL

MAINTAIN AND PROTECT

EXISTING SIDEWALK

TEMPORARY ROCK CONSTRUCTION

ENTRANCE. CONTRACTOR SHALL

MAINTAIN AND PROTECT CURB AND

ROADWAY PAVEMENT

INSTALL TEMPORARY STREAM

DIVERSION PUMP AND DISCHARGE

LINE (LAY FLAT). WITH TEMPORARY

SCOUR PROTECTION (TYP.)

PRIVATE DRIVEWAY SHALL NOT BE

USED BY CONTRACTOR FOR

ACCESS TO WORK AREAS.

PROJECT ACCESS SHALL BE FROM

LITTLE CRUM CREEK PARK ONLY

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-0

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF5 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

R

TH

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

E R

O S

IO

N

S

E D

IM

E

N T

C O

N

TR

O L

A N

D D

E M

O

LI

TI

O

N P

LA

N

LIMIT OF WORK/

LIMIT OF DISTURBANCE LINE

TREE PROTECTION FENCE/

CONSTRUCTION FENCE

ROCK CONSTRUCTION ENTRANCE/

TIRE CLEANING AREA

18 IN SILT FENCE

DEMO AND E&S LEGEND:

TREE TO BE REMOVED

STREAM DIVERSION

DISCHARGE LINE

CM-0501

EXISTING CONTOUR

EXISTING TREE

EXISTING STORM

PIPE

EXISTING CONCRETE

SIDEWALK

APPROXIMATE

PROPERTY LINE

EXISTING HEADWALL

EXISTING BRUSH LINE

EXISTING WETLAND

AREA

EXISTING LEGEND:

EXISTING ASPHALT

EXISTING INLET

EXISTING COMPOSITE

FENCE

EXISTING STORM PIPE

EXISTING SANITARY PIPE

EXISTING UNDERGROUND

POWER LINE

EXISTING STORM

MANHOLE

EXISTING SANITARY

MANHOLE

EXISTING PATH TO BE DEMOLISHED

(50 ' W

ID

E)

MATCHLINE

LANDS N/F

ELIZABETH A LARIN / STEVEN J

LARIN

107 YALE AVE

APN #43-00-01381-01

LANDS N/F

CRAIG STEVE FAVA /

KATHLEEN DOWNES FAVA

109 YALE AVE

APN #43-00-01381-00

LANDS N/F

SWARTHMORE BOROUGH

0 SWARTHMORE AVE

APN #43-00-01145-01

LANDS N/F

MARY MCCABE / MATTHEW

MCCABE

1 HARVARD AVE

APN #43-00-00575-00

X X

XX

X

X

X

X

X

X

XX

X

X

X X

X X

XX

TEMPORARY ROCK CONSTRUCTION

ENTRANCE. CONTRACTOR SHALL

MAINTAIN AND PROTECT CURB,

SIDEWALK, SANITARY MANHOLE AND

ROADWAY PAVEMENT

INSTALL TEMPORARY COFFER

DAM (TYP.)

INSTALL TEMPORARY STREAM DIVERSION PUMP AND

DISCHARGE LINE (LAY FLAT). WITH TEMPORARY

SCOUR PROTECTION (TYP.)

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-0

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF6 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

R

TH

LIMIT OF WORK/

LIMIT OF DISTURBANCE LINE

TREE PROTECTION FENCE/

CONSTRUCTION FENCE

ROCK CONSTRUCTION ENTRANCE/

TIRE CLEANING AREA

18 IN SILT FENCE

DEMO AND E&S LEGEND:

TREE TO BE REMOVED

STREAM DIVERSION

DISCHARGE LINE

LI

TT

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

E R

O S

IO

N

S

E D

IM

E

N T

C O

N

TR

O L

A N

D D

E M

O

LI

TI

O

N P

LA

N

CM-0502

EXISTING CONTOUR

EXISTING TREE

EXISTING STORM

PIPE

EXISTING CONCRETE

SIDEWALK

APPROXIMATE

PROPERTY LINE

EXISTING HEADWALL

EXISTING BRUSH LINE

EXISTING WETLAND

AREA

EXISTING LEGEND:

EXISTING ASPHALT

EXISTING INLET

EXISTING COMPOSITE

FENCE

EXISTING STORM PIPE

EXISTING SANITARY PIPE

EXISTING UNDERGROUND

POWER LINE

EXISTING STORM

MANHOLE

EXISTING SANITARY

MANHOLE

EXISTING PATH TO BE DEMOLISHED

MATCHLINE

LANDS N/F

MICHAEL E MATTHEWS / SARAH M

MATTHEWS

200 S SWARTHMORE AVE

APN #43-00-01148-00

LANDS N/F

MARY MCCABE / MATTHEW

MCCABE

1 HARVARD AVE

APN #43-00-00575-00

SWARTHMORE BOROUGH

RESTROOM

RECENTLY

GRADED AREA

BRANCHPACK

REGRADED AREA

5FT WIDE PARK POROUS

PAVEMENT PATH

(2% MAX CROSS SLOPE)

REFER TO LANDSCAPE

PLANS FOR SLOPE

REGRADING AND

STABILIZATION

BRANCHPACK

REGRADED AREA

99 TW

96 TW

93 BW

93 BW

94 BW

99 TW

98.4

99.5

100.2

100.2

99.5

99.3

99.3

99.4

93.8

93.4

92.6

CLEAR BRANCHES, LOOSE ROCKS, DEBRIS, ETC TOTHE LIMIT NOTED BEHIND AND ALONG INDICATEDIMPROVEMENTS. THEN, BACKFILL, FINISH GRADE WITHTOPSOIL, ANNUAL SEED, AND STRAW. BLEND GRADEINTO EXISTING SLOPE UNLESS NOTED OTHERWISE.REFER TO LANDSCAPE PLANS FOR PLANTING.

PROPOSED J-HOOK TYP.

SEE DETAIL 3/CM-6002

PROPOSED IMBRICATED RIP RAP TYP.

SEE DETAIL 1/CM-6002

PROPOSED COIR LOG TYP.

SEE DETAIL 2/CM-6001

PROPOSED TOE BOULDERS TYP.

SEE DETAIL 2/CM-6002

STREAM ACCESS PATH REFER TO

DETAIL 4/CM6002

CONTINGENCY #1: REPLACE

GABION BASKET WALL IN KIND IF

DAMAGED OR DETERIORATING

RELOCATED

MESSAGING

SIGN

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-1

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF7 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

R

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

S

IT

E

IM

P R

O V

E M

E N

T P

LA

N

EXISTING CONTOUR

EXISTING TREE

EXISTING STORM

PIPE

EXISTING CONCRETE

SIDEWALK

APPROXIMATE

PROPERTY LINE

EXISTING HEADWALL

EXISTING BRUSH LINE

EXISTING WETLAND

AREA

EXISTING LEGEND:

PROPOSED COIR MAT

PROPOSED LIMIT OF COIR MAT

PROPOSED COIR LOG

SITE IMPROVEMENT LEGEND:

PROPOSED MAJOR CONTOUR

PROPOSED MINOR CONTOUR101

GRADING LEGEND:

EXISTING ASPHALT

EXISTING INLET

EXISTING COMPOSITE

FENCE

PROPOSED POROUS PAVEMENT PATH

CM-1001

EXISTING STORM PIPE

EXISTING SANITARY PIPE

EXISTING UNDERGROUND

POWER LINE

EXISTING STORM

MANHOLE

EXISTING SANITARY

MANHOLE

PROPOSED WOOD CHIP PATH

(50 ' W

ID

E)

MATCHLINE

LANDS N/F

ELIZABETH A LARIN / STEVEN J

LARIN

107 YALE AVE

APN #43-00-01381-01

LANDS N/F

CRAIG STEVE FAVA /

KATHLEEN DOWNES FAVA

109 YALE AVE

APN #43-00-01381-00

LANDS N/F

SWARTHMORE BOROUGH

0 SWARTHMORE AVE

APN #43-00-01145-01

LANDS N/F

MARY MCCABE / MATTHEW

MCCABE

1 HARVARD AVE

APN #43-00-00575-00

91 92

5FT WIDE PARK WOOD CHIP

PATH SEE DETAIL 5/CM6002

92 TW

90 TW

89 BW

89 BW

93.4

92.6

92.6

92.7

92.4

92.5

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-1

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF8 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

R

TH

LI

TT

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

S

IT

E

IM

P R

O V

E M

E N

T P

LA

N

CM-1002

EXISTING CONTOUR

EXISTING TREE

EXISTING STORM

PIPE

EXISTING CONCRETE

SIDEWALK

APPROXIMATE

PROPERTY LINE

EXISTING HEADWALL

EXISTING BRUSH LINE

EXISTING WETLAND

AREA

EXISTING LEGEND:

PROPOSED COIR MAT

PROPOSED LIMIT OF COIR MAT

PROPOSED COIR LOG

SITE IMPROVEMENT LEGEND:

PROPOSED MAJOR CONTOUR

PROPOSED MINOR CONTOUR101

GRADING LEGEND:

EXISTING ASPHALT

EXISTING INLET

EXISTING COMPOSITE

FENCE

EXISTING STORM PIPE

EXISTING SANITARY PIPE

EXISTING UNDERGROUND

POWER LINE

EXISTING STORM

MANHOLE

EXISTING SANITARY

MANHOLE

EXISTING WATER PIPE

PROPOSED POROUS PAVEMENT PATH

PROPOSED WOOD CHIP PATH

MATCHLINE

LANDS N/F

MICHAEL E MATTHEWS / SARAH M

MATTHEWS

200 S SWARTHMORE AVE

APN #43-00-01148-00

LANDS N/F

MARY MCCABE / MATTHEW

MCCABE

1 HARVARD AVE

APN #43-00-00575-00

SWARTHMORE BOROUGH

BRANCHPACK

REGRADED AREA

5FT WIDE PARK POROUS

PAVEMENT PATH

(2% MAX CROSS SLOPE)

BRANCHPACK

REGRADED AREA

CLEAR BRANCHES, LOOSE ROCKS, DEBRIS, ETC TOTHE LIMIT NOTED BEHIND AND ALONG INDICATEDIMPROVEMENTS. THEN, BACKFILL, FINISH GRADE WITHTOPSOIL, ANNUAL SEED, AND STRAW. BLEND GRADEINTO EXISTING SLOPE UNLESS NOTED OTHERWISE.REFER TO LANDSCAPE PLANS FOR PLANTING.

PROPOSED J-HOOK TYP.

SEE DETAIL 3/CM-6002

CONTINGENCY #1: REPLACE

GABION BASKET WALL IN KIND IF

DAMAGED OR DETERIORATING

RESTROOM

RECENTLY

GRADED AREA

1 PO

1 AR 1 UV

1 UV

1 CTO

1 PO

1 UV

1 QB

1 QB

1 QB

1 CTO

1 BN

1 AR

1 BN

1 NS

1 NS

1 NS

1 LS

1 AR

1 LS

1 LS

1 AC

1 AC

1 AC

1 AC

1 AC

1 CC

1 CC

1 CC

1 CC

1 CC

1 NS

1 HV

1 HV

1 HV

1 HV

1 HV

1 MV

1 MV

1 MV

1 CF

1 CF

1 CF

1 CF

1 AC

1 MV

1 LB

1 LB

1 LB

1 LB 1 CC

1 LB

1 LB

1 LB

1 LB

1 LB

1 LB

1 LB

1 LB

1 LB

4 CO

2 CO

1 CO

1 CO

1 CO

2 CO

1 AS

1 AS

1 AS

1 AS

1 AS

1 LB

1 VD

1 VD

1 VD

1 VD

1 VD

1 VD

1 VD

1 VD

1 CA

1 CA

1 CA

1 CA

1 CA

1 CA

1 CA

1 CAF

1 CAF

1 CAF

1 CAF

1 CAF

1 AS

PROPOSED AREA SEEDED

WITH PA COASTAL PLAIN

PROVINCE RIPARIAN MIX

(ERNMX-273)20 BS/ ACRE WITH

30/LBS COVER CROP

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-2

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF9 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

R

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

LA

N

D S

C A

P

IN

G P

LA

N

COMMON NAMEBOTANICAL NAMEKEY QTY ROOTINITIAL SIZE NOTES

PLANT SCHEDULE - TREES AND SHRUBS

ORNAMENTAL TREES

AC Shadblow Serviceberry Multi-stem8 Amelanchier Canadensis

REMOVAL OF INVASIVE

PLANT NOTES:

1. REMOVAL OF INVASIVE PLANT

SPECIES IN THE WETLANDS MUST

BE DONE BY METHODS THAT DO

NOT DISTURB THE SOIL, EXCEPT

FOR SOIL THAT IS DISTURBED BY

INDIVIDUAL PLANT REMOVAL. SEE

SPECIFICATIONS FOR MORE

INFORMATION AND LIST OF

INVASIVE/EXOTIC PLANT MATERIAL

TO BE IDENTIFIED AND REMOVED. CM-2001

CC

HV

American HornbeamCarpinus Caroliniana #10 Container

WitchhazelHamamelis Virginiana #10-15 Container

BN River Birch Multi-stem3 Betula Nigra

LS 3 SweetgumLiquidambar Styraciflua 2" Cal

MV 4 Sweetbay MagnoliaMagnolia Virginiana #10-15 Container

NS 4 Black GumNyssa Sylvatica 2" Cal

QB 3 Swamp White OakQuercus Bicolor 2" Cal

SHRUBS

AS 7 Smooth AlderAlnus Serrulata #3-5 Container

CAF 6 Sweet PepperbushClethra Alnifolia #3-5 Container

CO 13 ButtonbushCephalanthuis Occidentalis #3-5 Container

CA 8 Silky DogwoodCornus Amomum #3-5 Container

LB 10 SpicebushLindera Benzoin #5 Container

VD 9 Southern ArrowwoodViburnum Denstatum #5 Container

COMMON NAMEBOTANICAL NAMEKEY QTY ROOTSPACING IC

PLANT SCHEDULE - PLUGS/GROUND COVER

Mix A -

AS Common Milkweed 24" O.CTBD Asclepias Syriaca

CXS

NJT

PV

Tussock SedgeCarex Stricta 24" O.C

24" O.C Upper Slopes/Full Sun

SwitchgrassPanicum Virgatum 36" O.C

BB Monarda Fistulosa 24" O.C

CXV Fox Sedge 24" O.C Lower Slopes/Partial Shade

Bee Balm

SS Little BluestemSchizachurium Scoparium 36" O.C

SSA Showy GoldenrodSolidago Speciosa 24" O.C

SNB New York AsterSymphyotrichum Novi-Belgii 24' O.C

VN Veronia Noveboracensis 24" O.C

Plug Partial sun/Mid slope

Plug

Plug

Plug

Plug

Plug

Plug

Plug

Plug

Plug

Upper slopes/ full sun

Lower Slopes/Partial Shade

Mid to lower slopes

Upper Slopes/Full Sun

Upper Slopes/Full Sun

Partial Sun/Mid Slope

Mid to lower slopes

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

COMMON NAMEBOTANICAL NAMEKEY QTY SPACING NOTES

PLANT SCHEDULE - LIVE STAKES (1,300 SF)

Cornus SericeaCS

Silky Dogwood

Cornus Amomum

SD Pussy WillowSalix Discolor

Soak for minimum 24 hours prior to installation, not to

Red Oiser Dogwood

3' O.C Triangular Spacing48CA

3' O.C Triangular Spacing

3' O.C Triangular Spacing exceed 14 days

All live stakes and brush mattress materials shall be harvested from dormant, locally adapted native stock. Species substitutions may be made based on contractor availability with approval of the Engineer.

Install live staking through brush mattress sections at the toe of slope to increase stabilization

BRUSH MATTRESS (1,200 SF)

3' O.C Square SpacingSilky Dogwood31CA

SD 36 Pussy Willow 3' O.C Square Spacing

Cornus Amomum

Salix Discolor

SI 33 Sandbar Willow 3' O.C Square SpacingSalix Interior

SL 33 Shining Willow 3' O.C Square SpacingSalix Lucida 133Total

All live stakes and brush mattress materials shall be harvested from dormant, locally adapted native stock.

Species substitutions may be made based on contractor availability with approval of the Engineer

Install brush mattress and live stakes immediately following earth disturbance. Any portions of the stream bank left exposed at the end of each workday shall be protected with erosion and sediment control measures.

Carex Vulpinoidea

New Jersey TeaCeanothus Americanus

AR Red Maple 2" Cal3 Acer Rubrum

CTO 3 Common HackberryCeltis Occidentalis 2" Cal

PO 3 SycamorePlatanus Occidentalis 2" Cal

UV 3 American ElmUlmus Americana 2" Cal

CF 4 Flowering DogwoodCornus Florida #10 Container

LB 6 SpicebushLindera Benzoin #5-10 Container

Total Plug Qty: 1,500 (Choose at least 7 of 10 species with no single species to exceed 20% (300) of total installed plugs)

Area seeded with Ernst Riparian seed Mix ERNMX-273 20 lbs/ac with 30 lbs/ac covercrop or approved equal (Seasonal dependant, see

SPECIFICATIONS)

LIVE STAKES (350 SF)

CONTINGENCY: LIVE STAKES AND BRUSH MATTRESS

Cornus SericeaCS

Silky Dogwood

Cornus Amomum

SD Pussy WillowSalix Discolor

Soak for minimum 24 hours prior to installation, not to

Red Oiser Dogwood

3' O.C Triangular Spacing13CA

3' O.C Triangular Spacing

3' O.C Triangular Spacing exceed 14 days

COMMON NAMEBOTANICAL NAMEKEY QTY SPACING NOTES

CONTINGENCY NOTES:

1. IF APPROVED, CONTINGENCY ITEM PLACEMENT TO BE FIELD VERIFIED WITH FIELD

INSPECTOR PRIOR TO INSTALLATION.

2. REGRADE/ REESTABLISH ANY INCISED BANKS AS NEEDED. PLACE LIVE STAKES AND BRUSH

MATTRESS ON NEWLY GRADED SLOPES.

3. INSTALL BRUSH MATTRESS AND LIVESTAKES ON ONLY UNVEGETATED SECTIONS OF BANK.

39Total

New York Ironweed

(50 ' W

ID

E)

MATCHLINE

LANDS N/F

ELIZABETH A LARIN / STEVEN J

LARIN

107 YALE AVE

APN #43-00-01381-01

LANDS N/F

CRAIG STEVE FAVA /

KATHLEEN DOWNES FAVA

109 YALE AVE

APN #43-00-01381-00

LANDS N/F

SWARTHMORE BOROUGH

0 SWARTHMORE AVE

APN #43-00-01145-01

LANDS N/F

MARY MCCABE / MATTHEW

MCCABE

1 HARVARD AVE

APN #43-00-00575-00

91 92

5FT WIDE PARK WOOD CHIP

PATH SEE DETAIL 5/CM6002

92 TW

90 TW

89 BW

89 BW

93.4

92.6

92.6

92.7

92.4

92.5

1 PO

1 CTO

1 BN

1 AR

1 NS

1 LS

1 AC

1 AC

1 CC

1 HV

1 CF

1 LB

1 LB

1 LB

2 CO

1 CO

1 CO

1 LB

1 AS

1 VD

1 VD

1 VD

1 CA

1 CAF

1 CAF

1 AS

U:

\A cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-2

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF10 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

R

TH

LI

TT

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

LA

N

D S

C A

P

IN

G P

LA

CM-2002

cc ou nt s\S

W

AT

B\

SW

AT

B0

Lit tle C ru m

C re ek R es to ra tio n\

DE

SI

GN

SH

EE

TS

\C M

-2

1.

TE

D:

4/

/2

1:

P

M, B Y:

La za r L az ov ic

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

SWATB00403

1"=20'

LL

2026-11-16

EPJ

SHEET

APPROVED BY

OF11 14

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

M ar ke t S tre et , S ui te

Ph ila de lp hi a, P A

T

5.

2.

F

5.

2.

A D

C

LE

C

R U

M C

R E

E K

R E

S

TO

R A

TI

O

N

LI

TT

LE

C R

U M

C R

E E

K P

A R

K

S W

A R

TH

M

O R

E B

O R

O U

G H

, P A

P A

R K

A V

E N

U E

S W

A R

TH

M

O R

E , P

A

B O

R O

U G

H O

F S

W A

R

TH

M O

R E

LA

N

D S

C A

P

IN

G D

E

TA

LS

CM-2003

DEAD AND BROKEN BRANCHES.

PRUNE ONLY TO REMOVE

USE DIGGING FORK NOT SPADE

TO ADJACENT AREAS.

THE BEST APPEARANCE OR RELATIONSHIP

SET PLANTS PLUMB AND FACE TO GIVE

TO PREVENT GLAZING OF SUBGRADE

NOTES:

REMOVE EXCESS SOIL FROM TOP OF

ROOT BALL AND SET TOP OF ROOT BALL

AT FINISHED GRADE OR 1" TO 2" ABOVE

IN POORLY DRAINED SOILS

REMOVE BURLAP FROM TOP 12 OF ROOT BALL

OR WITH CONTAINER PLANTS REMOVE POTS

AND LOOSEN ROOTS AS SPECIFIED

PLANTING SOIL MIX

SET PLANT ON UNDISTURBED SUBGRADE

HARDWOOD MULCH.

3" MIN. SHREDDED

PLANTING SOIL MIX

UNDISTURBED SOIL PLANT CONTAINERIZED

ABOVE ADJACENT GRADE

PERENNIAL 1"-2" PLANTING PIT TO

COMPACT BASE OF

PREVENT SETTLING

PROPOSED

GROUNDCOVER

(SPACING VARIES)

PLANTS (TYP)

MIN. 2' FROM BASE

FINISHED

REMOVE MULCH

GRADE

DO NOT USE TREE WRAP.

FROM TOP 1/2 OF ROOT BALL.

FOLD DOWN AND/OR REMOVE

BURLAP OR WIRE BASKET

THE WIDTH OF THE ROOT BALL

PLANTING PIT TO BE 3 TO 5 TIMES

DEAD AND BROKEN…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .