1-Drawings - Gage Elementary Resource Room Remodel.pdf
PDF 9 MB Posted
- Attached to
- Gage Elementary School Community Room Remodel
- Solicitation number
- Bid 033126
- Issued by
- Olmsted County, Minnesota
About this file
This is a construction drawing set for the Gage Elementary School Community Resource Room Remodel project in Rochester, Minnesota, prepared by CRW Architecture + Design Group in collaboration with Dunham Engineering, Inc. (mechanical and electrical) and SEH, Inc. (structural). The project involves remodeling approximately 1,700 square feet of interior space to convert an existing resource room into a Family and Consumer Sciences (FACS) room with teaching kitchen stations, along with creating a new resource room and modifying the media center layout. The scope of work includes selective demolition, concrete slab cutting and patching, underground plumbing installation, light gauge metal wall framing with gypsum board, new flooring (LVT and carpet), casework with stainless steel countertops, suspended acoustical tile ceilings, and modifications to HVAC, plumbing, fire suppression, electrical, and low voltage systems. The FACS room will feature three fully built-out student stations and one teacher station, with two additional student stations roughed-in with plumbing and electrical for future expansion. The construction documents are dated March 10, 2026, and prepared at 100% design development stage, incorporating 2024 International Building Code, 2020 Minnesota State Building Code, and 2020 Minnesota Accessibility Code requirements.
The project specifications and general conditions reference AIA Document A-201 (2007 Edition) and detailed specifications prepared by CRW Architecture + Design Group. The contractor is responsible for all permits, including demolition, building, zoning, utility connections, and site work permits, as well as coordination with local fire prevention authorities regarding key box installation and placement. The drawings specify material finishes including Formica plastic laminate base cabinets, Wilsonart countertops with optional Corian surfaces, LVT flooring (Artisan Oak pattern), resilient base materials, and paint specifications from Sherwin Williams. Mechanical work includes new exhaust fans, relocation of existing HVAC components including radiant ceiling panels, VAV boxes, and thermostats, with ventilation requirements based on 2020 Minnesota Mechanical Code calculations. The project requires coordination among general, mechanical, electrical, plumbing, and fire protection contractors, with the owner responsible for removing and relocating existing furniture and equipment prior to construction commencement.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OWNER
ARCHITECT
ELECTRICAL ENGINEER
MECHANICAL ENGINEER
ROCHESTER PUBLIC SCHOOLS
615 7TH ST SW
ROCHESTER, MINNESOTA 55902
CONTACT: BILL BURT
PHONE NUMBER: (507) 993-2968
EMAIL: william.burt@rochesterpublicschools.org
CRW ARCHITECTURE + DESIGN GROUP
211 ELEVENTH AVENUE NORTHWEST
ROCHESTER, MINNESOTA 55901
CONTACT: VERONICA KINGSTON
PHONE NUMBER: (507) 206-6201
EMAIL: vkingston@crwarchitecture.com
DUNHAM ENGINEERING, INC
421 FIRST AVE SW SUITE 201W
ROCHESTER, MN 55902
CONTACT: STEVE HARMON, PE.
PHONE NUMBER: (507) 424-3350
EMAIL: steve.harmon@dunhameng.com
DUNHAM ENGINEERING, INC
421 FIRST AVE SW SUITE 201W
ROCHESTER, MN 55902
CONTACT: OWEN NORD
PHONE NUMBER: (507) 424-6851
EMAIL: owen.nord@dunhameng.com
STUCTURAL ENGINEER
SEH, INC
3428 LAKERIDGE PL NW STE 100
ROCHESTER, MN 55901
CONTACT: BENJAMIN WOLFE
PHONE NUMBER: (507) 316-6648
EMAIL: bwolf@sehinc.com
N O
R T
H
SITE
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
NOT
FOR
CONSTRUCTION
© 2026 CRW architecture + design group
CONSTRUCTION DOCUMENT SET
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/10/26
KEY PLAN
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry C o m m u n it y R e s o u rc e R o o m R e m o d e l/
-0
R P
S G a g e E le m e n ta ry R e s o u rc e R o o m
R e m o d e l.
rv t
/1
/2
:2
:3
A
M
G0.00
03/10/26
COVER SHEET
R O
C H
E S
T E
R
M
IN
N
E S
O T
A
R P
S G
A G
E E
L E
M E
N T
A R
Y S
C H
O O
L R
E S
O U
R C
E R
O O
M R
E M
O D
E L
25-018
03/10/26
VLK/ERS
JW
RPS GAGE ELEMENTARY
SCHOOL RESOURCE ROOM
REMODEL
ROCHESTER MINNESOTA
PLANS ISSUED:03/10/26
1-GENERAL INFORMATION
G0.00 COVER SHEET
G0.01 GENERAL INFORMATION SHEET
2-ARCHITECTURAL DEMO
AD1.01 LEVEL 1 - DEMO PLAN
AD1.21 LEVEL 1 - DEMO REFLECTED CEILING PLAN
3-ARCHITECTURAL
A1.00 LEVEL 1 - FLOOR PLAN
A1.21 LEVEL 1 - REFLECTED CEILING PLAN
A2.00 INTERIOR ELEVATIONS, DETAILS &
SCHEDULES
4-STRUCTURAL
S1.00 STRUCTURAL PLAN
5- MECHANICAL
M000 MECHANICAL SYMBOLS AND
ABBREVIATIONS
xM880 VENTILATION MATRIX AND DAMPER MATRIX
MD100 PARTIAL MAIN LEVEL MECHANICAL
DEMOLITION PLAN
M100 PARTIAL MAIN LEVEL MECHANICAL PLAN
ME100 MECHANICAL AND ELECTRICAL SCHEDULES
FD100 PARTIAL MAIN LEVEL FIRE PROTECTION
DEMOLITION PLAN
F100 PARTIAL MAIN LEVEL FIRE PROTECTION
PLAN
P100 PARTIAL UNDERFLOOR PLUMBING PLAN
P101 PARTIAL MAIN LEVEL PLUMBING PLAN
P200 PLUMBING RISERS
6-ELECTRICAL
E100 ELECTRICAL DEMOLITION PLAN
E200 ELECTRICAL LIGHTING PLAN
E300 ELECTRICAL POWER AND SIGNAL PLAN
E500 ELECTRICAL DETAILS AND SCHEDULES
CODE INFORMATION: SHEET INDEXSITE LOCATION MAP
BUILDING LEGEND
AREA OF WORK
*****(update per specific project)*****
2024 INTERNATIONAL BUILDING CODE
2020 MINNESOTA STATE BUILDING CODE
2020 MINNESOTA ACCESSIBILITY CODE
2020 MINNESOTA CONSERVATION CODE FOR EXISTING BUILDINGS
PROPOSED PROJECT SUMMARY:
THIS PROJECT WILL EXPAND THE CURRENT RESOURCE ROOM AND CHANGE THE USE INTO A
FACS ROOM WITH 3 STUDENT STATIONS AND 1 TEACHER STATION BUILT OUT AND 2 STUDENT
STATIONS WITH PLUMBING AND ELECTRIC ROUGHED IN FOR FUTURE EXPANSION OPTIONS.
THIS PROJECT WILL ALSO CREATE A NEW RESOURCE ROOM AND INCLUDE MODIFICATIONS TO
THE MEDIA CENTER LAYOUT.
OCCUPANCY CLASSIFICATION (CHAPTER 3):
GROUP xx - xxxxxxxxxx
- GROUP xx OCCUPANCY OCCURS ON THE xxxxxxxx LEVEL
TYPE OF CONSTRUCTION (CHAPTER 6):
GROUP xx - xxxxxxxxxx IS PROTECTED BY TYPE xx CONSTRUCTION
- BUILDING IS x STORIES, (sprinklered or non-sprinklered)
TABLE 601 ~ FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS:
TYPE xx CONSTRUCTION
BUILDING ELEMENT: TYPE xx CONSTRUCTION HOURS:
STRUCTURAL FRAME x BEARING WALL - EXTERIOR x BEARING WALL - INTERIOR x NONBEARING WALLS - EXTERIOR x NONBEARING WALLS - INTERIOR x FLOOR CONSTRUCTION x ROOF CONSTRUCTION x
TABLE 504.3 ~ ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
OCCUPANCY xx, (sprinklered or non-sprinklered), TYPE xx CONSTRUCTION = xx FEET
PROPOSED BUILDING HEIGHT: xx' - x" = OK
TABLE 504.4 ~ ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
OCCUPANCY x, (sprinklered or non-sprinklered), TYPE xx CONSTRUCTION = xx STORIES
PROPOSED BUILDING STORIES: xx = OK
TABLE 506.2 ~ ALLOWABLE AREA FACTOR
OCCUPANCY x, (sprinklered or non-sprinklered), TYPE xx CONSTRUCTION = xx SF AREA
PROPOSED BUILDING AREA: xx = OK
TABLE 508.2.4 ~ ACCESSORY OCCUPANCY SEPARATIONS
NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIES AND MAIN
OCCUPANCIES.
*(look at section 508.2.4 exceptions to see if they apply to the specific project)*
N O
R T
H
NO. REVISIONS DATE
SCHEDULE OF REQUIRED PERMITS
DESCRIPTION OF PERMIT TYPE
PERMIT ARRANGED FOR AND
PAID FOR BY:
= NOT APPLICABLE= BY OWNER= BY CONTRACTOR
12. SIGNAGE PERMIT
11. FOOTING & FOUNDATION PERMIT
(IF PHASED PERMIT REQUESTED)
10. ZONING & BUILDING REVIEW & PERMIT
9. SITE GRADING PERMIT
8. SEWER & WATER CONNECTION PERMIT
7. TELEPHONE PERMIT
6. CABLE TELEVISION PERMIT
5. GAS UTILITY PERMIT
4. ELECTRICAL UTILITY PERMIT
3. DRIVEWAY APPROACH PERMIT
2. SIDEWALK PERMIT (IF APPLICABLE)
1. DEMOLITION PERMIT
A
B
C
D
E
F
P
O
N
M
L
K
J
H
G
R
S
T
U
V
W I
STANDARD ABBREVIATIONS
W/O.
W.C.
WD.
WDW.
WT.
W.W.F.
W.W.M.
VAR.
V.C.T.
U.L.
UNFIN.
U.N.O.
T.&G.
TEMP.
THK.
T.O.
T.V.
TYP.
SCHD.
SECT.
S.F.
SHT.
SHTG.
SIM.
SIM.REV.
SPEC.
STD.
STL.
STOR.
STRUCT.
SUSP.
SYM.
R.D.
REBAR
REF.
REINF.
REQ.
REV.
RM.
R.O.
PC.
PERF.
P.LAM.
PLYW.
O.C.
OF.D.
O.H.D.
OPNG.
OPP.
O.S.B.
N.I.C.
NO. / #
NOM.
N.T.S.
MAINT.
MATL.
MAX.
MECH.
MEMB.
MEZZ.
MFR.
MIN.
MIR.
MISC.
M.O.
MTD.
MTL.
LAM.
LAV.
L.F.
KIT.
JAN.
I.D.
IN.
INFO.
INSUL.
INT.
H.C.
HCP.
HDR.
HDWD
HDWR.
H.M.
HORIZ
HR.
HT./HGT.
GA
GALV.
G.C.
GYP. BD.
F.D.
FDN.
F.E.
F.E.CAB.
F.F.E.
FLR.
F.O.
F.R.P.
FT.
FTG.
FURN.
F.V.
DBL.
DEPT.
DET.
D.F.
DIA./ Ø
DIAG.
DIM.
DISP.
DN.
DR.
DS.
DWG.
C.I.P.
C.J.
C/L / ℄
CLG.
CLR.
C.M.U.
COL.
COMP.
CONC.
CONST.
CONT.
COORD.
CORR.
CPT.
CT.
BD.
BLDG.
BM.
B.O
BRG.
ACC.
A.C.T.
ADD.
ADJ.
A.F.F.
ALT.
APPROX.
ARCH.
AVG.
EA.
E.I.F.S.
E.J.
ELEC.
ELEV.
ENTR.
EQ.
EQUIP.
EXP.
EXIST.
ACCORDING/ACCORDION
ACOUSTICAL CEILING TILE
ADDENDUM
ADJUSTABLE/ADJACENT
ABOVE FINISHED FLOOR
ALTERNATE/ALTERATION
APPROXIMATE
ARCHITECT/ARCHITECTURAL
AVERAGE
BOARD
BUILDING
BEAM
BOTTOM OF
BEARING
DOUBLE
DEPARTMENT
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DISPOSAL
DOWN
DOOR
DOWNSPOUT
DRAWING
EACH
EXTERIOR INSUL. FINISH SYSTEM
EXPANSION JOINT
ELECTRICAL
ELEVATOR / ELEVATION
ENTRANCE
EQUAL
EQUIPMENT
EXPANSION
EXISTING
CAST IRON PIPE/CAST IN PLACE
CONTROL JOINT
CENTER-LINE
CEILING
CLEAR
CONCRETE MASONRY UNITS
COLUMN
COMPOSITE/COMPOSITION
CONCRETE
CONSTRUCTION
CONTINUOUS
COORDINATE
CORRIDOR
CARPET
CERAMIC TILE
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FLOOR ELEVATION
FLOOR
FACE OF
FIBERGLASS REINFORCED PANEL
FOOT OR FEET
FOOTING
FURNACE/FURNISH
FIELD VERIFY
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GYPSUM BOARD
HOLLOW CORE
HANDICAP
HEADER
HARDWOOD
HARDWARE
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
INSIDE DIMENSION
INCHES
INFORMATION
INSULATION
INTERIOR
LAMINATED
LAVATORY
LINEAL FOOT
KITCHEN
JANITOR
MAINTENANCE/MAINTAIN
MATERIAL
MAXIMUM
MECHANICAL
MEMBRANE
MEZZANINE
MANUFACTURER
MINIMUM/MINUTE
MIRROR
MISCELLANEOUS
MASONRY OPENING
MOUNTED
METAL
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OVERFLOW DRAIN
OVERHEAD DOOR
OPENING
OPPOSITE
ORIENTED STRAND BOARD
PRECAST
PERFORATED
PLASTIC LAMINATE
PLYWOOD
ROOF DRAIN
REINFORCING BAR
REFERENCE/REFRIGERATOR
REINFORCED
REQUIRED
REVISION/REVERSE
ROOM
ROUGH OPENING
SCHEDULE
SECTION
SQUARE FEET
SHEET
SHEATHING
SIMILAR
SIMILAR REVERSE
SPECIFICATION
STANDARD
STEEL
STORAGE
STRUCTURE/STRUCTURAL
SUSPENDED
SYMBOL
TONGUE AND GROOVE
TEMPERED/TEMPORARY/TEMPERATURE
THICK
TOP OF
TELEVISION
TYPICAL
UNDERWRITERS LABORATORIES, INC.
UNFINISHED
UNLESS NOTED OTHERWISE
VARIES
VINYL-COMPOSITION TILE
WITHOUT
WATER CLOSET
WOOD
WINDOW
WEIGHT
WELDED WIRE FABRIC
WELDED WIRE MESH
O.F.C.I. OWNER FURNISHED
CONTRACTOR INSTALLED
GRAPHIC SYMBOLS
100A
ROOM TAG
Room Name
DOOR TAG
WINDOW TAG1t
WALL PARTITION TYPE
FIRE EXTINGUISHER CABINET
A101
SIM
F.E.C
F.E
ELEVATION NUMBER
SHEET NUMBER
BUILDING SECTION NUMBER
SHEET NUMBER
FIRE EXTINGUISHER CABINET
INTERIOR ELEVATION MARK
ELEVATION MARKER
A1.100
Ref
Ref
R e fR e f
XX
2h
A101
Ref
1Ref 1 Ref
Ref
Name Elevation
WALL TYPE PATTERNS
EXISTING WALL CONSTRUCTION
EXIST. WALL TO BE REMOVED
SOUND BATT INSULATION
NEW MASONARY WALL
NEW POUR CONCRETE WALL
CONCRETE
MASONARY UNIT
BRICK MASONARY
TYPICAL FILL PATTERN
PLYWOOD
CONTINIUS WOOD
FRAMING
CONCRETE
SAND
INTERRUPED
WOOD FRAMING
FINISHED WOOD
EARTH
RIGID INSULATION
GRAVEL FILL
BATT INSULATION
STEEL
MOUNTING NOTES:
ADA COMPLIANT
ADA COMPLIANT
STD. ADA COMPLIANT (DUAL)
ADA COMPLIANT
ADA COMPLIANTTYPICAL MOUNTING HEIGHTS FORTYPICAL
MOUNTING HT. FOR
ADA COMPLIANT
FRONT APPROACH ADA COMPLIANT
ADA COMPLIANT
ADA COMPLIANT
TYPICAL LOCATION FOR
ADA COMPLIANT
TYPICAL SIZE, SPACING &
MOUNTING OF
SIDEWALL
VERTICAL AND
HORIZONTAL
GRAB BARS
PER 2/A0.1
30" CLEAR
S
T D
. M T
G . H
G H
T
DIRECTION OF
APPROACH
PLAN VIEW FRONT ELEVATION SIDE ELEVATION
FRONT ELEVATION SECTION
FRONT ELEVATION SIDE ELEVATION
FRONT ELEVATION SIDE ELEVATION
SIDE VIEW
'PUSH' SIDE
OF DOOR
'PULL' SIDE
OF DOOR
FRONT VIEW PLAN VIEW
PROTRUDING DISPENSER
BELOW GRAB BAR
RECESSED DISPENSER
TOILET
MOUNT
TYP. TOILET PARTITION
TYPICAL
URINAL
SCREEN
COAT HOOK(S)
TOILET PAPER
DISPENSER - SEE
DETAILS TO
RIGHT
GRAB BARS GRAB BARS
PAPER
TOWEL
DISPENSER
PAPER
TOWEL
DISPENSER
SOAP
DISP.
CLEAR FLOOR AREA TO REMAIN
CLEAR OF OBSTRUCTIONS FOR
WHEELCHAIR TO FIXTURE
ACCESS
30"x48" MIN. CLEAR FLOOR SPACE
REQUIRED (ANY ORIENTATION) FOR
ACCESSIBLE STALL ENTRY/EXITING,
ADJACENT TO DOOR
ALWAYS REQUIRED
FRONT VIEW ADA
COMPLIANT ELEVATOR
BUTTONS & SIGNALS
ELEVATOR
DOORS
*-54" MAX. FOR EXISTING
BUTTONS
OUTLETS
CLEAR
FLOOR
AREA
CLEAR
FLOOR
AREA
SEE 7/A0.1 FOR KNEE
& TOE CLEARANCE
INFO.
ADA COMPLIANT PIPE
WRAP AT EXPOSED
PIPES -TYP.
URINAL
FIXTURE
(T R
A S
H
48"
CLEAR
LAVATORY PROVIDED W/
INSULATED EXPOSED
PLUMBING PIPE COVERS (NOT
SHOWN)
BRACKETCABINET
MOUNT
30"x48" CLEAR FLOOR
SPACE (ADA MINIMUM)
ROOM SIGNAGE, SEE SPEC
FOR DESCRIPTION AND SIZE
DOOR FRAME
HAND
DRYER
REQUIRED ONLY WHEN BOTH A
LATCHSET AND CLOSER IS USED
COUNTER TOP &
SINK TO BE
ACCESSIBLE
BABY
CHANGING
TO TOP OF DECK
WHEN OPEN
CONTROLS/
SWITCHES
ACCESSIBLE
TOILET
FIXTURE
NOTE:
G.C. TO PROVIDE ANCHORAGE TO
WALL W/ ADEQUATE BLOCKING
- ADA DESIGN HEIGHT TO BE
PROVIDED AS REQUIRED
1" CLOSET
ROD
(SEE SPEC.)
3/4" P.LAM SHELF W/
P.LAM WALL
SUPPORTS
MIRROR TO
MATCH VANITY
LENGTH
2'-0"x3'-0" MIRROR
CENTERED ON LAV.
ACCESSIBLE
C U
P S
HANDRAIL HANDRAIL (GRAB
BAR)
1. THIS SHEET IS FOR GENERAL INFORMATION AND REFERENCE ONLY. ANY JOB
SPECIFICDRAWINGS IN THESE CONTRACT DOCUMENTS ARE TO TAKE PRECEDENCE
OVER SIMILAR DRAWINGS SHOWN ON THIS SHEET.
2. IF DISCREPANCIES ARE FOUND BETWEEN STANDARD OR GENERAL DETAILS AND JOB
SPECIFIC DETAILS INCLUDED IN THIS SET, PLEASE CONTACT THE ARCHITECT FOR
CLARIFICATION.
3. ALL CONDITIONS SHOWN ON THIS SHEET MAY NOT BE PRESENT WITHIN THESE
CONTRACT DOCUMENTS
4. ALL CLEARANCES AND MOUNTING HEIGHTS ARE INTENDED TO COMPLY WITH CURRENT
ACCESSIBILITY CODE.
END PANEL (WHERE
APPLICABLE)
PER MN. CODE SECTION 1012 -
HANDRAILS SHALL RETURN TO A
WALL, GUARD OR THE WALKING
SURFACE OR SHALL BE CONTINUOUS
TO THE HANDRAIL OF AN ADJACENT
STAIR FLIGHT OR RAMP RUN OR SHALL
COMPLY WITH THE DIAGRAM AT RIGHT.
ROUND-OVER CONC.
TOP (SMOOTH FINISH)
6" DIA. STEEL PIPE BOLLARD
FILL PIPE SOLID W/ CONC.
PRIME AND PAINT PIPE,
COLOR TO BE SELECTED BY
ARCHITECT FROM STANDARD
FINISHES GRADE
18" DIA. CONC. PIER
6" CLEAN GRANULAR
MATERIAL AT BASE
ACCESSIBLE TOILET ELEVATIONS
7 LAVATORY PLAN & ELEVATION
DRINKING FOUNTAIN
AMBULATORY TOILET STALL
LATCH SIDE DOOR CLEARANCES
COAT ROD & SHELF/ COAT HOOKS
BOLLARD DETAIL
ELEVATOR SIGNALS
8 FIRE EXTINGUISHER
VANITY ELEVATION & SECTION
ACCESSIBLE REACH LIMITATIONS
ACCESSIBLE TOILET PLAN
6 URINAL PLAN & ELEVATION
RESTROOM SIGNAGE
STAIR TREAD/RISERS & HANDRAILS
DISPENSER INSTALLATION LOCATIONS
60"
WALL SPACE
42" MIN. CLEAR 16"-18"
M
IN
C
L E
A R
O R
M
IN
C
L E
A R
60" CLEAR
36" MIN. 6"
MIN.
24"
MIN.
12"
16''-18"
T O
S E
A T
M
IN
MAX
12" 42" MIN.
54"
39"-41"
M
IN
MIN.
24"
42" MAX.
1- 1/
M
IN
P
E R
.3
M
IN
MIN.
24"
42" MAX.
36"
M
IN
M A
X
M
IN
MIN.
32"
17"-19"
36" CLEAR
M A
X
M A
X
O F
C A
L L B
U T
T O
N S
M A
X H
E
IG
H T
H E
IG
H
T O
F S
IG
N
A L S
M
IN
A D
A M
T G
H
G H
T T
O L
IP
CLEAR
30"
M A
X
U .N
.O
C L E
A R
M
IN
48" MIN. CLEAR
MAX.
17" - 25"
M A
X
M
IN
MIN.
8"
18"
M
IN
M
IN
M
IN
M
IN
M
IN
6"
M A
X
T O
P O
F E
X T
IN
G
U
IS
H E
R
M A
X
TOIL
M
IN
M A
X
M A
X T
O S
P O
U T
T
O S
P O
U T
FLOOR SPACE
30" CLR 2
M
IN
M A
X T
O S
P O
U T
8" MIN.
M
IN
FLOOR SPACE
48" MIN.CLR
MAX
6"
1 1/4"-2"
1 1/2" MIN
1 1/4"-2"
1 1/2" MIN
M A
X
11" MIN.
1 1/2" MAX.
30° MAX.
MIN.
12"
A D
A M
A X
T O
C E
N T
E R
O F
R O
D
12"
14"
T O
T H
E T
O P
O F
S H
E L F
SEE PLAN
MIN.
12"
CLEAR
18" MIN.
CLEAR
32" MIN.
M
IN
M A
X
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/10/26
KEY PLAN
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry C o m m u n it y R e s o u rc e R o o m R e m o d e l/
-0
R P
S G a g e E le m e n ta ry R e s o u rc e R o o m
R e m o d e l.
rv t
/9 /2
:4
:4
P M
G0.01
JASON WOODHOUSE
44421 03/10/26
GENERAL INFORMATION
SHEET
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S G
A G
E E
LE
M
E N
T A
R Y
S C
H O
O L
R E
S O
U R
C E
R O
O M
R E
M O
D E
L
25-018
03/10/26
VLK/ERS
JW
1. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL DETAILS, SECTIONS, NOTES, ETC. ARE
TO BE CONSIDERED AS BEING TYPICAL AT ALL SIMILAR LOCATIONS OR CONDITIONS. IN
THESE DOCUMENTS, DETAILS, NOTES, ETC. ARE NOT INDICATED OR REFERENCED AT ALL
POSSIBLE APPLICABLE LOCATIONS.
2. THE SPECIFICATIONS AS PREPARED BY CRW ARCHITECTURE + DESIGN GROUP SHALL
BE CONSIDERED A PART OF THESE DOCUMENTS AS IF BOUND HEREIN.
3. A.I.A. DOCUMENT A-201, GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION,
2007 EDITION, SHALL BE CONSIDERED AS PART OF THESE DOCUMENTS AS IF BOUND
HEREIN. REFER TO THE SPECIFICATIONS FOR ADDITIONAL SUPPLEMENTAL CONDITIONS.
4. THE CONTRACTOR SHALL NOTIFY ALL APPROPRIATE ENGINEERING DEPARTMENTS AND
UTILITY COMPANIES 72 HOURS PRIOR TO CONSTRUCTION. ALL NECESSARY PRECAUTIONS
SHALL BE TAKEN TO AVOID DAMAGE TO ANY EXISTING UTILITY.
5. BEFORE BIDDING, FABRICATION OR BEGINNING WORK, CONTRACTOR SHALL VISIT
PROJECT SITE, REVIEW ALL CONSTRUCTION DOCUMENTS AND UNDERSTAND THEM IN THEIR
ENTIRETY. THE CONSTRUCTION DOCUMENTS MUST BE VIEWED IN THEIR ENTIRETY AS
COMPLETE SETS.
6. BEFORE BIDDING, FABRICATION OR BEGINNING WORK, CONTRACTOR SHALL VISIT
PROJECT SITE AND FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ETC.
7. CONTRACTOR SHALL IMMEDIATELY REPORT ANY DISCREPANCIES, CONTRADICTIONS OR
QUESTIONS REGARDING THE CONTRACT DOCUMENTS OR EXISTING CONDITIONS TO THE
ARCHITECT IMMEDIATELY FOR RESOLUTION.
8. CONTRACTOR SHALL IMMEDIATELY REPORT ANY CODE VIOLATIONS IN THE CONTRACT
DOCUMENTS TO THE ARCHITECT FOR RESOLUTION.
9. DO NOT SCALE DRAWINGS. IN ALL CASES STATED DIMENSIONS TAKE PRECEDENCE.
CONTACT ARCHITECT IMMEDIATELY FOR ADDITIONAL REQUIRED DIMENSIONS. GENERAL
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, VERIFY AND COORDINATE WITH EXISTING
CONDITIONS AND COORDINATE THE WORK, TIMING AND PHASING OF ALL TRADES.
10. ALL DEMOLITION, NEW CONSTRUCTION, SITE WORK AT INTERIOR AND EXTERIOR OF
BUILDING SHALL BE IN CONFORMANCE WITH ALL APPLICABLE CODE REQUIREMENTS,
INCLUDING BUT NOT LIMITED TO, CURRENT BUILDING CODE
11. ALL FINISH MATERIALS SHALL CONFORM TO APPLICABLE FLAME SPREAD AND SMOKE
GENERATED REQUIREMENTS.
12. ALL FIRE RATED WALLS SHALL BE CONSTRUCTED PER APPROVED U.L. OR OTHER
ACCEPTABLE TESTING AGENCY REQUIREMENTS TO MEET OR EXCEED STATED FIRE
RATINGS. ALL PENETRATIONS OF FIRE RATED BUILDING ELEMENTS SHALL BE SIMILARLY
CONSTRUCTED PER LOCAL BUILDING CODE TO MAINTAIN REQUIRED FIRE RATINGS.
13. IF AT ANY TIME THE CONTRACTOR ENCOUNTERS OR UNCOVERS ASBESTOS
CONTAINING BUILDING MATERIALS OR OTHER POSSIBLE HAZARDOUS OR TOXIC MATERIALS,
IT'S PRESENCE SHALL BE IMMEDIATELY REPORTED TO ARCHITECT AND BUILDING OWNER.
14. CONTRACTOR SHALL FOLLOW OSHA AND OTHER APPLICABLE SAFETY REQUIREMENTS
DURING ALL WORK INCLUDING BUT NOT LIMITED TO DEMOLITION, REPAIR AND
CONSTRUCTION.
15. ALL EXISTING MATERIALS TO REMAIN WHICH ARE DISTURBED OR DAMAGED AND ALL
OTHER CUTTING SHALL BE PATCHED BACK AS REQUIRED TO LIKE NEW CONDITION, TO
MATCH ADJACENT SURFACES AND TO MAKE SUCH REPAIR IMPERCEPTIBLE.
16. BEFORE DEMOLITION, FABRICATION OR CONSTRUCTION, CONTRACTOR SHALL VERIFY
THAT NO CONFLICTS EXIST IN LOCATIONS OR CLEARANCE REQUIREMENTS OF
STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, TELECOMMUNICATIONS, TELEPHONE,
DATA OR FIRE PROTECTION SYSTEMS AND THEIR ELEMENTS.
17. FIREBLOCKING, FIRESTOPS, DRAFTSTOPPING SHALL BE INSTALLED AS REQUIRED BY
CURRENT LOCAL BUILDING CODE REQUIREMENTS. TYPICAL AS REQUIRED AT PARTITIONS,
CONCEALED COMBUSTIBLE SPACES, CONCEALED COMBUSTIBLE ATTIC SPACES, FLOOR
PENETRATIONS, PENETRATIONS THROUGH FIRE RATED PARTITIONS OR OTHER
STRUCTURES AS REQUIRED BY CURRENT CODE.
18. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL TEMPORARY SHORING OR BRACING
AND FOR THE DESIGN, CONSTRUCTION, STABILITY AND SAFETY OF ALL TEMPORARY
STRUCTURES, ENCLOSURES AND SCAFFOLDING.
19. CONTRACTOR SHALL COORDINATE THE TIMING, PHASING AND EXECUTION OF ALL
CUTTING AND PATCHING FOR THE EFFICIENT AND TIMELY COMPLETION OF WORK.
20. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR TEMPORARY PROTECTION AT ANY
OPENINGS IN FLOORS, ROOFS, WALLS, ETC.
21. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR DETERMINING ERECTION
PROCEDURE AND CONSTRUCTION SEQUENCE IN ORDER TO ENSURE THE SAFETY OF THE
BUILDING, WORKMEN AND VISITORS.
22. CONTRACTOR SHALL SAFELY AND LEGALLY REMOVE AND DISPOSE OF ALL MATERIALS
NOT SCHEDULED TO BE SALVAGED OR RE-INSTALLED.
23. CONTRACTOR SHALL MAINTAIN A STAMPED, APPROVED SET OF CONSTRUCTION
DOCUMENTS WITH APPROVAL LETTER AND CURRENT SHOP DRAWINGS. DOCUMENTS ON
SITE SHALL BE KEPT UP TO DATE.
24. MATERIAL OR PRODUCT SUBSTITUTIONS SHALL FOLLOW THE SUBSTITUTION
REQUIREMENTS OF DIVISION 01 OF THE PROJECT SPECIFICATIONS DOCUMENT.
25. SHOP DRAWINGS OR OTHER SUBMITTALS SHALL FOLLOW THE SUBMITTAL
REQUIREMENTS OF DIVISION 01 OF THE PROJECT SPECIFICATIONS DOCUMENT.
26. THE FIRE PROTECTION CONTRACTOR AND PLUMBING CONTRACTOR SHALL CONFIRM
ALL FLOW TEST INFORMATION WITH THE LOCAL FIRE DEPARTMENT AND WATER
DEPARTMENT AS REQUIRED.
27. GENERAL CONTRACTOR SHALL PROVIDE APPROVED KEY BOXES AS REQUIRED BY
LOCAL FIRE MARSHALL. INSTALL AT LOCATIONS AS REQUIRED BY THE FIRE MARSHALL.
28. VERIFY MINIMUM SLOPES TO DRAIN AS INDICATED ON THE DRAWINGS PRIOR TO THE
START OF CONSTRUCTION. NOTIFY THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF
ANY DISCREPANCIES.
29. FIELD VERIFY ELEVATIONS, FLOW LINES, EXISTING CONDITIONS, AND POINTS OF
CONNECTION OF SITE IMPROVEMENTS WITH EXISTING UTILITIES PRIOR TO THE START OF
CONSTRUCTION. ANY DISCREPANCIES ARE TO BE IMMEDIATELY CALLED TO THE ATTENTION
OF THE ARCHITECT AND CIVIL ENGINEER.
30. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM THE BUILDING AT ALL
LOCATIONS TO AVOID PONDING OF WATER AT BUILDING OR ON PAVEMENT. DRAINAGE
SLOPE FOR ALL PAVED SURFACES SHALL BE 1% MINIMUM. MAXIMUM ALLOWABLE CROSS
SLOPE AT ALL WALKS AND HANDICAP ACCESSIBLE WALKS AND RAMPS SHALL BE 2%.
31. REPAIR EXISTING PUBLICLY OWNED FACILITIES OR STRUCTURES DAMAGED OR
ALTERED DURING DEMOLITION OR CONSTRUCTION TO THE SATISFACTION OF THE LOCAL
MUNICIPALITY.
32. EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE, CONTRACTOR SHALL ENSURE THAT
ALL FINISH MATERIALS SHALL BE APPLIED TO BE FLUSH WITH ADJACENT SURFACES AND
JOINTS.
33. CONTRACTOR TO PROVIDE AND INSTALL BLOCKING, DOUBLE STUDS, AND/OR ANCHOR
PLATES AS NECESSARY TO SUPPORT EQUIPMENT, PLUMBING FIXTURES, CASEWORK,
CABINETS, GRAB BARS, TOILET ROOM ACCESSORIES, SIGNAGE, HANDRAILS, ETC.
34. CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS, DIMENSIONS, AND ALL
REQUIRED CLEARANCES OF ALL EQUIPMENT. COORDINATE WITH DRAWINGS,
SPECIFICATIONS, EQUIPMENT MANUALS AND CUT SHEETS. VERIFY THAT STRUCTURAL
LOADS ARE ACCEPTABLE.
35. GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION AND LOCATION OF THE FIRE
DEPARTMENT KEY BOX W/ THE ROCHESTER FIRE PREVENTION BUREAU.
GENERAL NOTES
IC
DEMOLITION NOTES:
GENERAL DEMOLITION NOTES:
1. DASHED LINES REPRESENT EXISTING ITEMS TO BE REMOVED, U.N.O.
2. PROVIDE ALL WORK TO COMPLETE DEMOLITION AS MAY BE REQUIRED
TO ACCOMPLISH WORK AS SHOWN ON THE DRAWINGS UNLESS
NOTED OTHERWISE. ALL AS INDICATED OR REQUIRED RELATING TO
THE EXISTING BUILDING AND NOT OTHERWISE ASSIGNED IS INCLUDED
UNDER THE RESPONSIBILITY OF THE CONTRACTOR.
3. CONTRACTOR TO VERIFY EXISTING ELECTRICAL & PLUMBING
LOCATIONS PRIOR TO DEMOLITION. EXISTING PLUMBING AND
ELECTRICAL MAY REQUIRE MODIFICATION TO ACCOMPLISH THE NEW
DESIGN AS SHOWN ON THESE PLANS.
4. MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS SHALL
TERMINATE ALL APPROPRIATE SERVICES TO EXISTING CONSTRUCTION
WHICH ARE TO BE PERMANENTLY DISCONNECTED. THEY SHALL
FURTHER MAKE ALL TEMPORARY SERVICE TERMINATIONS INDICATED
OR REQUIRED TO ACCOMPLISH THE DEMOLITION AND/OR NEW
REVISED OR REPLACED SERVICES AS PART OF WORK UNDER ALL
CONTRACTS. ALL PERMANENT TERMINATIONS SHALL BE REMOVED
BACK TO THE SOURCE. NO VACANT SERVICES SHALL BE LEFT IN
PLACE.
5. CONTRACTORS ARE TO BE RESPONSIBLE FOR REMOVING AND
HAULING OF ALL DEMOLITION DEBRIS.
6. AT CONCLUSION OF DEMOLITION, ALL SURFACES SHALL BE READY TO
RECEIVE NEW FINISHES.
7. OWNER TO REMOVE/ RELOCATE ALL FURNITURE, FIXTURES AND
EQUIPMENT PRIOR TO START OF CONSTRUCTION, COORDINATE
PROJECT SCHEDULE WITH GENERAL CONTRACTOR.
1 REMOVE AND DISPOSE OF EXISTING DEMOUNTABLE PARTITIONS
IN THEIR ENTIRETY.
2 REMOVE AND DISPOSE OF EXISTING DOOR, FRAME, AND
HARDWARE IN IT'S ENTIRETY.
(NOT ALL DEMOLITION NOTES APPEAR ON EVERY SHEET)
3 REMOVE AND DISPOSE OF EXISTING MASONRY WALL PARTITION
FOR NEW DOOR. SEE STRUCT FOR NEW LINTEL.
4 REMOVE AND SALVAGE MEDIA CENTER SHELVING TO OWNER.
5 DEMO EXISTING LVT AND BASE TYP. THROUGHOUT SPACE.
6 REMOVE AND DISPOSE OF EXISTING PROJECTOR SCREEN AND
TACKBOARDS.
7 MODIFY EXISTING TACK STRIP FOR NEW DOOR.
8 DEMO AND SALVAGE EXISTING CARPET FOR PATCH WORK.
9 REMOVE CONCRETE SLB TO ALLOW FOR PLUMBING WORK.
EXISTING SANITARY SEWER IS APPROX. 7'-0" BELOW SLAB. SEE
MECH.
10 EXISTING COLUMN TO REMAIN - TYP.
11 EXISTING SHELVING AND CASEWORK TO REMAIN U.N.O. - TYP.
12 EXISTING FLOOR DRAIN TO REMAIN.
13 EXIST. WASHER/DRYER TO BE TEMPORARILY REMOVED AND
STORED.
4 4
FACS ROOM
RESOURCE
ROOM
214C
CLASSROOM
MEDIA CENTER
AD1.01
3' - 4" 2' - 2"
1' - 2 3/8"
EXIST EXIST
EXIST EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXISTEXIST
SPEECH
SPEECH
PSYCH.
215A
FOCUS ROOM
FERNBROOK
214B
BEHAVIOR
SUPPORT
214A
EXIST EXIST
EXISTING COURTYARD
EXISTING COURTYARD
11' - 8" 3' - 7"
12' - 5"
4' - 4"5' - 8"
FACS ROOM
MEDIA CENTER
3' - 9" 4' - 11" 4' - 8"
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/10/26
KEY PLAN
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry C o m m u n it y R e s o u rc e R o o m R e m o d e l/
-0
R P
S G a g e E le m e n ta ry R e s o u rc e R o o m
R e m o d e l.
rv t
/9 /2
:4
:4
P M
AD1.01
JASON WOODHOUSE
44421 03/10/26
LEVEL 1 - DEMO PLAN
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S G
A G
E E
LE
M
E N
T A
R Y
S C
H O
O L
R E
S O
U R
C E
R O
O M
R E
M O
D E
L
25-018
03/10/26
VLK/ERS
JW
1/4" = 1'-0"
LEVEL 1 DEMO PLAN
1/4" = 1'-0"
LEVEL 1 SLAB CUTTING PLAN
NO. REVISIONS DATE
N O
R T
H
N O
R
F
A
A
S F
A A
OPEN TO DECK
FACS ROOM
RESOURCE
ROOM
214C
CLASSROOM
MEDIA CENTER
SPEECH
SPEECH
PSYCH.
215A
FOCUS ROOM
FERNBROOK
214B
BEHAVIOR
SUPPORT
214A
A.F.F.9' - 0"
A.F.F.9' - 0"
A.F.F.9' - 0"
A.F.F.12' - 0"
A.F.F.12' - 0"
A.F.F.9' - 0"
A.F.F.12' - 0"
A.F.F.12' - 0"
A.F.F.9' - 0"
1. MECHANICAL AND ELECTRICAL INFORMATION SHOWN IS INTENDED ONLY TO
COMMUNICATE DESIGN INTENT. REFER TO MECHANICAL AND ELECTRICAL
DRAWINGS FOR DETAILED INFORMATION. NOTIFY ARCHITECT/ENGINEER OF ANY
DISCREPANCIES NOTED PRIOR TO COMMENCEMENT OF WORK.
2. COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORTS, DEVICE LOCATIONS,
CLEARANCES, ETC. WITH EQUIPMENT INSTALLERS AND SUPPLIERS PRIOR TO
INSTALLATION.
3. ACOUSTICAL PANEL CEILING GRIDS OR PANELS SHALL BE CENTERED IN ROOMS
UNLESS OTHERWISE NOTED OR DIMENSIONED.
4. ALL CEILING MOUNTED ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS,
ETC.) SHALL BE CENTERED IN ACOUSTICAL CEILING PANELS OR GYPSUM BOARD
SOFFITS UNLESS OTHERWISE NOTED OR DIMENSIONED.
5. SPACE LIGHT FIXTURES EVENLY IN ROOMS, BAYS, SPACES, ETC. AND CENTER
BETWEEN EXPOSED STRUCTURAL ELEMENTS WHERE APPROPRIATE.
6. DIMENSIONS TO CEILING-INSTALLED ITEMS ARE TO CENTERLINE OF FIXTURE OR
EQUIPMENT UNLESS NOTED OTHERWISE.
7. LOCATE CONTROL JOINTS IN GYPSUM BOARD CEILINGS, SOFFITS, BULKHEADS,
AND FASCIAS AS INDICATED ON DRAWINGS OR AS SPECIFIED AND TO ALIGN WITH
THOSE IN WALLS BELOW. VERIFY PROPOSED LAYOUT WITH ARCHITECT PRIOR TO
INSTALLATION.
8. PAINT ALL CONDUITS, DUCTWORK, SUPPORTS, HANGERS, ETC. THAT WILL REMAIN
EXPOSED TO VIEW. MATCH COLOR INDICATED FOR STRUCTURE UNLESS NOTED
OTHERWISE.
GENERAL CEILING NOTES:
ACOUSTICAL CEILING TILE (ACT-1)
CEILING TYPES LEGEND
GYPSUM BOARD TO BE PAINTED (PT-6)
CEILING PLAN DEMO NOTES:
ACOUSTICAL CEILING TILE (ACT-2)
1 REMOVE AND SALVAGE EXISTING CEILING TILES. REMOVE AND
DISPOSE OF EXISTING GRID.
2 REMOVE EXISTING FASCIA AND FRAMING.
3 REMOVE AND SALVAGE EXISTING CEILING TILES. REMOVE
EXISTING SUSPENDED ACT CEILING IN THIS AREA TO
ACCOMMODATE NEW WORK.
4 REMOVE AND/OR MODIFY EXISTING SUSPENDED ACT CEILING TO
ACCOMMODATE NEW WALLS. SALVAGE EXISTING CEILING TILES.
5 LT GA METAL FRAMING AND FASCIA TO REMAIN
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/10/26
KEY PLAN
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry C o m m u n it y R e s o u rc e R o o m R e m o d e l/
-0
R P
S G a g e E le m e n ta ry R e s o u rc e R o o m
R e m o d e l.
rv t
/9 /2
:4
:4
P M
AD1.21
JASON WOODHOUSE
44421 03/10/26
LEVEL 1 - DEMO REFLECTED
CEILING PLAN
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S G
A G
E E
LE
M
E N
T A
R Y
S C
H O
O L
R E
S O
U R
C E
R O
O M
R E
M O
D E
L
25-018
03/10/26
VLK/ERS
JW
1/4" = 1'-0"
LEVEL 1 - DEMO REFLECTED CEILING PLAN
NO. REVISIONS DATE
N O
R
1. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL
REQUIREMENTS OF THE OWNER. EACH TRADE CONTRACTOR SHALL BE
RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL
SAFETY PROCEDURES, PRECAUTIONS AND PROGRAMS IN CONNECTION
WITH THEIR WORK.
2. THE GENERAL CONTRACTOR SHALL FILE FOR AND OBTAIN ALL REQUIRED
PERMITS, LETTERS OF SATISFACTORY COMPLETION AND CERTIFICATES
OF OCCUPANCY FROM THE LOCAL BUILDING OFFICIALS.
3. ALL EQUIPMENT SHOWN AS DASHED IS BY THE OWNER. ELECTRICAL
CONTRACTOR TO VERIFY POWER REQUIREMENTS FOR OWNER'S
EQUIPMENT. MECHANICAL CONTRACTOR TO VERIFY PLUMBING AND
HVAC REQUIREMENTS OF OWNER'S EQUIP.
4. REFER TO THE MECHANICAL, ELECTRICAL DRAWINGS FOR ADDITIONAL
WORK REQUIRED UNDER THIS CONTRACT.
5. THE GENERAL CONTRACTOR AND/OR MECHANICAL CONTRACTOR SHALL
COORDINATE ALL MECHANICAL WORK WITH THE OWNER'S
REPRESENTATIVE AND ALL OTHER TRADES.
6. THE GENERAL CONTRACTOR AND/OR ELECTRICAL CONTRACTOR SHALL
COORDINATE ALL ELECTRICAL WORK WITH THE OWNER'S
REPRESENTATIVE AND ALL OTHER TRADES.
GENERAL NOTES:
FLOOR PLAN NOTES:
1 BASE BID: FUTURE KITCHENETTES TO BE ROUGHED IN
WITH PLUMBING AND ELECTRIC, TO BE BUILT OUT AT A
LATER DATE. SEE MEP PLANS.
ALTERNATE A-1: STATIONS 4 & 5 TO BE BUILT OUT
COMPLETELY.
2 INSTALL NEW 4' x 8' MARKERBOARDS PROVIDE BACKING AS
NEEDED.
3 FUTURE MONITOR LOCATION (BY OWNER).
4 INSTALL EXISTING RESOURCE ROOM STORAGE FURNITURE
IN NEW ROOM LOCATION, COORDINATE WITH OWNER FOR
LOCATION.
5 INSTALL NEW FLOORING AND WALL BASE. SEE FINISH
SCHEDULE.
6 INSTALL NEW LVT FLOORING WHERE CARPET TILES WERE
REMOVED, MATCH EXISTING LVT.
7 REFILL, INFILL CONCRETE SLAB AS NEEDED TO MATCH
EXISTING CONSTRUCTION, AND PREPARE FOR NEW LVT.
8 PATCH CARPET AS NEEDED WHERE BOOKCASES AND
WALLS HAVE BEEN MOVED. MATCH EXISTING PATTERN.
9 RESILIENT RANSITION STRIP AT FLOORING CHANGE.
10 4'-0" HIGH STAINLESS STEEL CORNER GUARD.
11 9'-0" HIGH STAINLESS STEEL CORNER GUARD.
12 EXISTING COLUMN TO REMAIN.
13 ENCLOSE EXISTING COLUMN IN NEW FRAMING.
A2.00
17' - 3"
V .I
.F
210A
210B
FACS ROOM
RESOURCE
ROOM
214C
CLASSROOM
MEDIA CENTER
A2.004
6' - 6" 19' - 11" 1" 3' - 4"
A2.00
A2.00 7
A2.003
A1.00
2' - 2"
MIN.
12"
J4.f
J6f
J6f
J4
J4
J4
J4
J4
J4
EXIST
CPT
LVT-1
LVT-1
EXIST
LVT
LV
T-1
E
XIS
T
LV
T
L V
T -1
E X
IS
T
L V
T
STATION 1 STATION 2
STATION 3 STATION 4
STATION 5
SPEECH
SPEECH
PSYCH.
215A
FOCUS ROOM
FERNBROOK
214B
BEHAVIOR
SUPPORT
214A
A2.00
9' - 10" 10' - 8"
16' - 3" 14' - 9"
8' - 6"
A2.00
A2.004
A2.00
A2.00 7
A2.003
FACS ROOM
210A
210B
J6f
EMBED
3"
EPOXY DOWEL INTO EXIST. SLAB
AT 3' - 0" O.C. - MIN. 1 PER SIDE
COMPACTED GRANULAR FILL TO
DEPTH OF EXIST GRANULAR
NEW CONC. SLAB
EXIST. SLAB ON GRADE
EXIST COMPACTED
GRANULAR FILL
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/10/26
KEY PLAN
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry C o m m u n it y R e s o u rc e R o o m R e m o d e l/
-0
R P
S G a g e E le m e n ta ry R e s o u rc e R o o m
R e m o d e l.
rv t
/9 /2
:4
:4
P M
A1.00
JASON WOODHOUSE
44421 03/10/26
LEVEL 1 - FLOOR PLAN
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S G
A G
E E
LE
M
E N
T A
R Y
S C
H O
O L
R E
S O
U R
C E
R O
O M
R E
M O
D E
L
25-018
03/10/26
VLK/ERS
JW
1/4" = 1'-0"
LEVEL 1 PLAN
1/4" = 1'-0"
FACS 210 FLOOR PLAN
N O
R T
H
N O
R T
H
NO. REVISIONS DATE
1" = 1'-0"
SLAB ON GRADE INFILL DETAIL
1. MECHANICAL AND ELECTRICAL INFORMATION SHOWN IS INTENDED ONLY TO
COMMUNICATE DESIGN INTENT. REFER TO MECHANICAL AND ELECTRICAL
DRAWINGS FOR DETAILED INFORMATION. NOTIFY ARCHITECT/ENGINEER OF ANY
DISCREPANCIES NOTED PRIOR TO COMMENCEMENT OF WORK.
2. COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORTS, DEVICE LOCATIONS,
CLEARANCES, ETC. WITH EQUIPMENT INSTALLERS AND SUPPLIERS PRIOR TO
INSTALLATION.
3. ACOUSTICAL PANEL CEILING GRIDS OR PANELS SHALL BE CENTERED IN ROOMS
UNLESS OTHERWISE NOTED OR DIMENSIONED.
4. ALL CEILING MOUNTED ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS,
ETC.) SHALL BE CENTERED IN ACOUSTICAL CEILING PANELS OR GYPSUM BOARD
SOFFITS UNLESS OTHERWISE NOTED OR DIMENSIONED.
5. SPACE LIGHT FIXTURES EVENLY IN ROOMS, BAYS, SPACES, ETC. AND CENTER
BETWEEN EXPOSED STRUCTURAL ELEMENTS WHERE APPROPRIATE.
6. DIMENSIONS TO CEILING-INSTALLED ITEMS ARE TO CENTERLINE OF FIXTURE OR
EQUIPMENT UNLESS NOTED OTHERWISE.
7. LOCATE CONTROL JOINTS IN GYPSUM BOARD CEILINGS, SOFFITS, BULKHEADS,
AND FASCIAS AS INDICATED ON DRAWINGS OR AS SPECIFIED AND TO ALIGN WITH
THOSE IN WALLS BELOW. VERIFY PROPOSED LAYOUT WITH ARCHITECT PRIOR TO
INSTALLATION.
8. PAINT ALL CONDUITS, DUCTWORK, SUPPORTS, HANGERS, ETC. THAT WILL REMAIN
EXPOSED TO VIEW. MATCH COLOR INDICATED FOR STRUCTURE UNLESS NOTED
OTHERWISE.
9. NO WORK IN SHADED GRAY AREA.
GENERAL CEILING NOTES:
ACOUSTICAL CEILING TILE (ACT-1)
CEILING TYPES LEGEND
CEILING PLAN NOTES:
1 MODIFY EXISTING ACT CEILING TO ACCOMMODATE NEW WALL
A.F.F.9' - 0"
A.F.F.9' - 0"
A.F.F.9' - 0"
A.F.F.12' - 0"
A.F.F.12' - 0"
A.F.F.9' - 0" A.F.F.9' - 0"
A.F.F.9' - 0"
A.F.F.9' - 0"
A.F.F.9' - 0"
A.F.F.12' - 0"
A.F.F.9' - 0"
A.F.F.9' - 0"
A.F.F.9' - 0"
A2.00
FACS ROOM
RESOURCE
ROOM
214C
CLASSROOM
MEDIA CENTER
SPEECH
SPEECH
PSYCH.
215A
FOCUS ROOM
FERNBROOK
214B
BEHAVIOR
SUPPORT
214A
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/10/26
KEY PLAN
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry C o m m u n it y R e s o u rc e R o o m R e m o d e l/
-0
R P
S G a g e E le m e n ta ry R e s o u rc e R o o m
R e m o d e l.
rv t
/9 /2
:4
:4
P M
A1.21
JASON WOODHOUSE
44421 03/10/26
LEVEL 1 - REFLECTED
CEILING PLAN
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S G
A G
E E
LE
M
E N
T A
R Y
S C
H O
O L
R E
S O
U R
C E
R O
O M
R E
M O
D E
L
25-018
03/10/26
VLK/ERS
JW
1/4" = 1'-0"
LEVEL 1 - REFLECTED CEILING PLAN
NO. REVISIONS DATE
N O
R
IC
GENERAL INTERIOR ELEVATION NOTES:
1. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL
REQUIREMENTS OF THE OWNER. EACH TRADE CONTRACTOR SHALL BE
RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL
SAFETY PROCEDURES, PRECAUTIONS AND PROGRAMS IN CONNECTION
WITH THEIR WORK.
2. REFERANCE TMI SYSTEMS FOR CASEWORK SPECIFICATIONS.
INTERIOR ELEVATION NOTES:
1 PLAM-1 BASE CABINETS AND FILLER WITH RB-1 INSTALLED
AT BASE
2 COUNTERTOP WITH 4" HIGH BACKSPLASH
3 PLAM-1 FINISHES END PANEL
4 SS-2 WALL CAP WITH 1/2" OVERHANG
5 4'X8' MARKERBOARD
2' - 8" 1' - 3" 2' - 7" 1' - 0"
3"
4' - 5"
3"
1' - 0" 2' - 7" 1' - 3"
1' - 3" 2' - 7" 6' - 11" 2' - 7" 1' - 3"
3 3
2' - 0"
3"
2' - 0" 3' - 0"
3/4"
2' - 0 1/4"
3/4"
2' - 6"
/2
2' - 0" 9' - 11"
DW
/2
12' - 2"
2' - 0"
3"
1' - 3"
CLEAR
2' - 7" 1' - 3"
/2
2' - 7" 1' - 3"
2' - 0" 5' - 4"
/2
1' - 3" 3' - 0" 1' - 3"
3"
2' - 0"
8' - 0"
5' - 9" 2' - 0"
/2
/2
DW
MIC.
CLEAR
2' - 6"
3/4"
2' - 0 1/4"
3/4"
CLEAR
3' - 0" 2' - 0"
3"
2' - 0"
/2
/2
9' - 11" 2' - 0"
12' - 2"
C L E
A R
C L E
A R
1' - 3" 3' - 0" 2' - 6" 2' - 6" 1' - 3"
10' - 6"
10' - 8"
3' - 6"
1' - 0"
5"
2' - 0"
J4
FINISH MATERIAL INDEX:
ACOUSTICAL MATERIALS
ACT-1 USG, RADAR EDUCATION HIGH-NRC, HIGH-NRC/HIGH-CAC
CEILING, PROFILE: SQUARE, SIZE: 24" X 24", COLOR:
WHITE, GRID: PRELUDE, SIZE: 15"/16", COLOR: WHITE
*CONTRACTOR TO CONFIRM THIS IS THE EXISTING CEILING TILE
WITH OWNER
RESILIENT FLOORING
RB-1 FLEXCO, PROFILE: COVE, HEIGHT: 4", COLOR: UMBER 78,
INSTALL AT WALL AND AT CASEWORK BASE
LVT-1 MIDWEST ELEVATED, SIZE: 7"X48", PATTERN: ARTISAN OAK 303
*ONLY AVAILABLE THROUGH HILLER'S FLOORING AMERICA
CARPET
CPT-1 MILLIKEN, PATTERN: EDGE LIT, COLOR: ATMOSPHERE, SIZE: 1M X
1M, INSTALL: QUARTER TURN (INFILL IN MEDIA CENTER AS
REQUIRED).
MANUFACTURED CABINETS/CUSTOM CABINETS
PLAM-1 FORMICA, HARD ROCK MAPLE 86992 (BASE CABINETS)
PLAM-2 WILSONART, CRISP LINEN 4942-38 (COUNTERTOP)
SS-1 FORMICA, SCIENTIFIC SURFACE, TRESPA TOPLAB PLUS, VP122,
THICKNESS: 3/4", COLOR: PURE WHITE (ALTERNATE #2
COUNTERTOP SELECTION)
SS-2 CORIAN, SOLID SURFACE, COLOR: ANTARTICA (WALL CAPS AND
ALTERNATE #3 COUNTERTOP SELECTION)
PAINTS AND COATING
PT-1 SHERWIN WILLIAMS, PURE WHITE SW 7005 (GENERAL WALL FIELD)
PT-2 SHERWIN WILLIAMS, RAINDROP SW 6485 (TEACHING WALL
ACCENT)
PT-3 SHERWIN WILLIAMS, PEPPERCORN SW 7674 (H.M. DOOR FRAMES)
WOOD STAINING
WD-1 ARCHITECTURAL WOOD DOORS, SPECIES: WHITE OAK, STAIN:
SERENGETI SE18 (INTERIOR DOOR PANELS)
HARDWARE GROUPS:
GROUP 1: LOCKED CLASSROOM FUNCTION
EACH DOOR SHALL HAVE:
• HINGES
• ONE LOCKSET D70PD
• FUNCTION: OUTSIDE LEVER LOCKED AND UNLOCKED BY KEY. INSIDE
LEVER ALWAYS UNLOCKED.
• ONE STOP
D-1 D-2
FLUSH HALF LITE
SCHEDULE
SEE
SCHEDULE
SEE
E
E S
C H
E D
U L
E S
C H
E D
U L E
EQ. 20" EQ.
8" 8"
F-1 F-2
2" 2"
WIDTH
DOOR
D O
O R
H E
IG
H
T
2" 2"
WIDTH
DOOR
D O
O R
H E
IG
H
T
TYPICAL TYPICAL MASONRY
J4
J-BEAD
BLOCKING
GYP. BD. TO BE FLUSH
WITH FACE OF PANEL
NEOPRENE GASKET
EXIST. DE-MOUNTABLE
PARTITION
J4
• 5/8" GYPSUM BOARD
• 3-5/8" STUDS AT 24" o.c.
• 5/8" GYPSUM BOARD
WALL
TYPE
'AS INDICATED IN DIAGRAM ABOVE'
TYPICAL INTERIOR PARTITION, METAL FRAMED
PROPRIETARY DESIGN FIRE RATING/TEST:(WHERE APPLICABLE)
1/2 HOUR RATING - GA FILE NO. WP 0703
TEST: UL R3501, 12CA09542, 03-28-12,
UL Design W411
GYPSUM WALLBOARD, METAL STUDS
Fire Design:
One layer 5/8” proprietary gypsum wallboard applied parallel or at right angles to each side of 3-5/8", 15 mil steel studs 24" o.c. iwth 1" Type S screws 8" o.c.
Vertical joints centered over studs and staggered one stud cavity each side. Horizontal joints need not be staggered or backed. (NLB)
Thickness: 4-7/8” (Fire and Sound)
Approx. Weight:
Fire Test: UL R3501, 12CA09542, 03-28-12, UL Design W411
5 psf (Fire and Sound)
STC SOUND RATING/TEST:
STC: 45 - 49
SOUNT TEST: NGC 2014005, 02-18-14
J4 A
J4
4 7/8"
'J4' PARTITIONS TO RECEIVE
SOUND BATT INSULATION NOTED
J4 A
GA FILE NO.
WP 0703
PROPRIETARY 1/2 HOUR FIRE
J6 'AS INDICATED IN DIAGRAM ABOVE W/ 2x6 STUDS IN LIEU OF 2x4 STUDS' (SEE EXPLANATORY NOTE 17 OF GA-600-2024)
J4.f 'AS INDICATED IN DIAGRAM ABOVE MINUS 5/8" GYPSUM BOARD ON ONE SIDE' J6.f 'AS INDICATED IN DIAGRAM ABOVE MINUS 5/8" GYPSUM BOARD ON ONE SIDE AND W/ 2x6 STUDS IN LIEU OF 2x4 STUDS'
(SEE EXPLANATORY NOTE 17 OF GA-600-2024)
45 TO 49 STC
SOUND
Sound Design:
Sound tested with 3-1/2" glass fiber insulation friction fit into stud cavity.
PROPRIETARY GYPSUM PANEL PRODUCTS
National Gypsum Company
- 5/8" Gold Bond® High Strength Fire-Shield 30® Gypsum Board
Sound Test: NGC 2014005, 02-18-14
EXIST. LIGHT GAGE METAL
BRACING - PROVIDE ADD.
BRACING @ 32" O.C.
EXIST. GYP. BD
EXIST. FRAMING AND
BATT INSUL.
NEW REVEAL CHANNEL
ATTACH SLIP TRACK TO
EXIST. FRAMING.
NEW SUSPENDED ACT CEILING
8' - 0" 11' - 4"
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/10/26
KEY PLAN
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry C o m m u n it y R e s o u rc e R o o m R e m o d e l/
-0
R P
S G a g e E le m e n ta ry R e s o u rc e R o o m
R e m o d e l.
rv t
/1
/2
:1
:0
A
M
A2.00
JASON WOODHOUSE
44421 03/10/26
INTERIOR ELEVATIONS,
DETAILS & SCHEDULES
R O
C H
E S
T E
R
M
IN
N
E S
O T
A
R P
S G
A G
E E
L E
M E
N T
A R
Y S
C H
O O
L R
E S
O U
R C
E R
O O
M R
E M
O D
E L
25-018
03/10/26
VLK/ERS
JW
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
DOOR FRAME TYPE
COMMON DOOR SCHEDULE
D o o r
N u m b e r
R o o m
N a m e
L e a f Q ua n tit y
Door Frame
S id e lig h t W id th
F ir e R a tin g
G la ss F ir e
R a tin g
H a rd w a re
G ro u p
In su l D o o r
T h re sh ol d
W 'S tr ip pi n g
C o m m e n ts
W id th
H e ig h t
T h ic kn es s
T yp e
M a te ria l
F in is h
T yp e
M a te ria l
F in is h
210A FACS ROOM 1 3' - 2" 7' - 0" 1 3/8" D-1 WD F-2 H.M. 1 CONTRACTOR TO CONFIRM DOOR HEIGHT
MATCHES EXISTING DOORS HEIGHTS IN FACILITY
210B FACS ROOM 1 3' - 0" 7' - 0" 1 3/8" D-2 WD F-1 H.M. 1 CONTRACTOR TO CONFIRM DOOR HEIGHT
MATCHES EXISTING DOORS HEIGHTS IN FACILITY
214 RESOURCE
ROOM
1 3' - 0" 7' - 0" 1 3/8" D-2 WD F-1 H.M. 1 CONTRACTOR TO CONFIRM DOOR HEIGHT
MATCHES EXISTING DOORS HEIGHTS IN FACILITY
1/4" = 1'-0"
DOUBLE STATION ELEVATION #1
1/4" = 1'-0"
DOUBLE STATION ELEVATION #2
1/4" = 1'-0"
SINGLE STATION ELEVATION #1
1/4" = 1'-0"
SINGLE STATION ELEVATION #2
1/4" = 1'-0"
DOUBLE STATION ADA SIDE
1/4" = 1'-0"
TEACHING STATION
1/4" = 1'-0"
TEACHING STATION END
ROOM FINISH SCHEDULE
ROOM # ROOM TITLE FLOOR BASE
WALLS CEILINGS (SEE R.C.P.)
COMMENTS
NORTH SOUTH EAST WEST TYPE CLG. HT.
210 FACS ROOM LVT-1 RB-1 PT-1 PT-2 PT-1 PT-1 ACT-1 9' - 0"
212 CLASSROOM EXIST./LVT-1 RB-1 PT-1 EXIST. PT-1/EXIST. EXIST. EXIST./ACT-1 9' - 0" PAINT NEW WALLS PT-1 AND INSTALL RB-1 BASE.
214 MEDIA CENTER EXIST./CPT-1 EXIST./RB-1 EXIST. EXIST. EXIST. PT-1 EXIST. VARIES PAINT NEW WALLS PT-1 AND INSTALL RB-1 BASE.
214C RESOURCE ROOM EXIST./LVT-1 EXIST./RB-1 PT-1 PT-1 PT-1 - EXIST./ACT-1 9' - 0"
NO. REVISIONS DATE
3" = 1'-0"
PLAN DETAIL @ NEW STUD WALL TO DE-MOUNTABLE
PARTITION
3" = 1'-0"
NEW STUD WALL TO EXIST. SOFFIT FRAMING
1/4" = 1'-0"
TEACHING WALL
DESIGNATIONSSYMBOLDESIGNATIONSSYMBOLDESIGNATIONSSYMBOL DESIGNATIONSSYMBOL
PLUMBING
ACID VENT
ACID WASTE
DEIONIZED WATER SUPPLY
FILTERED WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER (TEMP. INDICATED)
DOMESTIC RECIRC. HOT WATER
HARD COLD WATER
OVERFLOW STORM DRAIN
REVERSE OSMOSIS WATER
SANITARY VENT
SANITARY WASTE
SOIL DRAINAGE TILE
SOFTENED COLD WATER
SOFTENED HOT WATER
TEMPERED WATER
STORM DRAIN
WELL WATER
AV
AW
DIS
HARD
SDT
RO
V
W
SOFT
SHW
TW
OSD
SD
WW
NPCW NON-POTABLE COLD WATER
NPHW NON-POTABLE HOT WATER
FW
HW
RHW
GW GREASE WASTE
DOMESTIC COLD WATERCW
CLEAR WATER VENTCWV
CLEAR WATER WASTECWW
DOM. RECIRC. HOT WATER (TEMP. INDICATED)140 RHW
PUMPED ACID WASTEPAW
PUMPED STORMPSD
PUMPED WASTEPW
COMPRESSED AIR (PSI INDICATED)10#A
MECHANICAL PIPING
BOILER FEED
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSATE DRAIN
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL VENT
FUEL OIL FILL
GLYCOL SUPPLY
GLYCOL RETURN
HEAT RECOVERY SUPPLY
HEAT RECOVERY RETURN
HEATING WATER SUPPLY
HEATING WATER RETURN
LIQUIFIED PETROLEUM GAS
NATURAL GAS (PSI INDICATED)
PUMPED CONDENSATE
RADIATION WATER SUPPLY
RADIATION WATER RETURN
REFRIGERANT LIQUID
BF
CWS
CWR
CD
FOS
GS
GR
HRS
HRR
HWR
HWS
LPG
2#G
FOF
PC
RADS
CS
CR
FOR
FOV
RADR
RL
REFRIGERANT SUCTION
REFRIGERANT HOT GAS BYPASS
REHEAT WATER SUPPLY
REHEAT WATER RETURN
REMOTE RADIATOR SUPPLY
REMOTE RADIATOR RETURN
SECONDARY HEATING WATER SUPPLY
SECONDARY HEATING WATER RETURN
SNOW MELT SUPPLY
SNOW MELT RETURN
STEAM SUPPLY (PSI INDICATED)
STEAM CONDENSATE (PSI INDICATED)
RRS
RS
RHG
RHR
RHS
RRR
SHWS
SHWR
SMS
SMR
10#STM
10#SC
PIPE FITTINGS
ELBOW DOWN
PIPE CAP
ELBOW UP
TEE, OUTLET UP
TEE, OUTLET DOWN
CONNECTION, TOP
ECCENTRIC REDUCER
CONCENTRIC REDUCER
PIPE UNION
PIPE FLANGE
ELBOW
TEE
FIRE PROTECTION
DFP
F FIRE PROTECTION
FIRE PROTECTION (DRY SYSTEM)
POST INDICATOR VALVE (PIV)
RECESSED FIRE DEPT CABINET
SURFACE MOUNTED FIRE DEPT CABINET
FIRE PROTECTION RISER
UPRIGHT SPRINKLER HEAD W/GUARD
PENDANT SPRINKLER HEAD
UPRIGHT SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
BUTTERFLY VALVE W/TAMPER SWITCH
DETECTOR CHECK W/BYPASS METER
GRADE FIRE DEPT CONNECTION
FLUSH FIRE DEPT CONNECTION
FIRE DEPT VALVE W/CAP AND CHAIN
O.S. & Y. VALVE W/TAMPER SWITCH
DRY PIPE VALVE
PREACTION VALVE
TS
FDVC
FDVC
FDV
TS
ANNOTATION
(4)A-12"ø
GRILLE, REGISTER, &
DIFFUSER IDENTIFICATION
QUANTITY
CFM
TYPE
SIZE
X X
X X
X X
X X
DETAIL NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
EQUIP DESIGNATION
EQUIP NUMBER
POINT OF CONNECTION, NEW TO EXISTING
POINT OF DISCONNECTION
FTR/RP 01
6'-5"
0.5
HYDRONIC FINNED TUBE
RADIATION & RADIANT
PANEL IDENTIFICATION
TYPE ACTIVE
ELEMENT
LENGTHGPM
EBR 01
6'-5"
ELECTRIC BASEBOARD
RADIATION
IDENTIFICATION
ACTIVE
ELEMENT
LENGTH
TYPE
INTERRUPTIBLE GASIG
ATMOSPHERIC STEAM SUPPLY
ATMOSPHERIC STEAM CONDENSATE
ATM STM
ATM SC
CONNECTION, BOTTOM
DARK DASHED LINE WEIGHT INDICATES
EXISTING ITEM TO BE DEMOLISHED.
GENERAL
LIGHT SOLID LINE WEIGHT INDICATES
EXISTING ITEM TO REMAIN.
DARK SOLID LINE WEIGHT INDICATES
NEW ITEM OR NEW LOCATION.
ROUND
12x12
12ø 12/12
RECTANGULAR (WxH)
FLAT-OVAL (W/H)
DUCT
DIMENSIONS
GENERAL DUTY VALVES
CHECK VALVE
SHUTOFF VALVE
PLUG VALVE
BALL VALVE
BUTTERFLY VALVE
GLOBE ANGLE VALVE
O. S. & Y. VALVE
SOLENOID VALVE
FLOW LIMITING VALVE
GLOBE VALVE
S
OR
OR
OR
OR
OR
GATE VALVE
DESIGNATIONSSYMBOL
MECHANICAL SYMBOLS LEGEND
XXXX #-## EXISTING EQUIP NUMBER
EXISTING EQUIP DESIGNATION
DEIONIZED WATER RETURNDIR
AUTOMATIC AIR VENT
AUTOMATIC CONTROL VALVE, 2-WAY
AUTOMATIC CONTROL VALVE, 3-WAY
STRAINER W/BLOWDOWN
CAP AND VALVE
PIPE SPECIALTIES
FLEXIBLE CONNECTION
PIPE ANCHOR
ALIGNMENT GUIDE
STRAINER
PRESSURE REDUCING VALVE
(SETTING AS NOTED, PSI)
EXPANSION JOINT
MANUAL AIR VENT
PRESSURE RELIEF/SAFETY
VALVES(SETTING AS NOTED, PSI)
DRAIN VALVE
REDUCED PRESSURE ZONE BACK
FLOW PREVENTER
DIAPHRAGM
REFRIGERANT SIGHT GLASS
GAS PRESSURE REGULATOR VALVE
BACKWATER VALVE
REFRIGERANT DRYER
FLOW DIRECTION
FLOW DIRECTION W/PITCH
DUPLEX STRAINER
PUMP
THERMOMETER
PRESSURE/TEMPERATURE TEST PORT
STEAM TRAP (TYPE INDICATED)
FLOW SWITCH
PRESSURE GAUGE W/PIGTAIL &
PETCOCK
PRESSURE SWITCH
FLOOR DRAIN
DRAIN ABOVE
FLOOR SINK
WALL HYDRANT
HOSE BIBB
WALL CLEANOUT
ROOF DRAIN
MANHOLE
HB
A
M
FS
PS
GAS COCK VALVE
WH
WATER HAMMER ARRESTOR
CATCH BASIN
DUCTWORK
SUPPLY AIR OR OUTDOOR AIR
RETURN AIR
EXHAUST AIR
STANDARD BRANCH, NO SPLITTER -
SUPPLY FLOW TO RIGHT -
RETURN/EXHAUST FLOW TO LEFT
BELLMOUTH WITH BALANCING
DAMPER
FLEXIBLE DUCT
TURNING VANES
FLEXIBLE CONNECTION
MANUAL VOLUME DAMPER
MOTORIZED DAMPER
TYPE:
FD = FIRE DAMPER
SD = SMOKE DAMPER
FSD = COMBINATION FIRE/SMOKE
DAMPER
CRD = CEILING RADIATION DAMPER
ORIENTATION:
SUPPLY GRILLE OR REGISTER
RETURN DUCT UP, NEGATIVE
PRESSURE
SUPPLY DIFFUSER/REGISTER
BLANKOFF INDICATED
RETURN OR EXHAUST GRILLE OR
REGISTER
SUPPLY DUCT UP, POSITIVE
PRESSURE
EXHAUST DUCT UP, NEGATIVE
PRESSURE
RETURN GRILLE/REGISTER
EXHAUST GRILLE/REGISTER
LINEAR DIFFUSER
CONCENTRIC DUCT TRANSITION
ECCENTRIC DUCT TRANSITION
RECTANGULAR-TO-ROUND DUCT
TRANSITION
VAV BOX
REHEAT COIL
VAV BOX W/ REHEAT COIL
DUCT OFFSETS
DUCT CUTLINE
M
XXX
RETURN DUCT DN, NEGATIVE
PRESSURE
SUPPLY DUCT DN, POSITIVE
PRESSURE
EXHAUST DUCT DN, NEGATIVE
PRESSURE
DROPRISE
VERTICAL
XXX
XXX
XXX
ACTUATOR (AS
APPLICABLE)
HORIZONTAL
BLADE/CURTAIN
FIRE, SMOKE, AND
COMBINATION
FIRE/SMOKE DAMPERS
TYPE
ORIENTATION
AIRFLOW MEASURING STATIONAFMS
VAV BOX W/ DUCT SILENCER
VENTURI TYPE AIR VALVE
VAV BOX W/ DUCT SILENCER
& REHEAT COIL
VAV BOX W/ ELECTRIC REHEAT
CONTROLS
AQUA STAT
TAMPERPROOF THERMOSTAT
HUMIDISTAT OR R.H. SENSOR
REFRIGERANT SENSOR
SMOKE DETECTOR
SPACE TEMPERATURE SENSOR
STATIC PRESSURE SENSOR
ROOM PRESSURE MONITOR
THERMOSTAT
THERMOSTAT W/GUARD
CARBON MONOXIDE SENSOR
CARBON DIOXIDE SENSOR
DIFFERENTIAL PRESSURE SENSOR
TEMPERATURE SENSOR
A
CO2
CO
H
R
P
SD
TS
SP
PS
T
T
T
DP
TS
P
ENERGY METER
FLOW METER
GPM
EM
MECHANICAL ABBREVIATIONS
AD AREA DRAIN
A.F.F. ABOVE FINISHED FLOOR
AFMS AIR FLOW MEASURING STATION
AHU AIR HANDLING UNIT
ANB ACID NEUTRALIZING BASIN
AP ACCESS PANEL
ARCH ARCHITECT
AS AIR SEPARATOR
BD BUTTERFLY DAMPER
B/G BELOW GRADE
BTU BRITISH THERMAL UNIT
BWV BACKWATER VALVE
CCF HUNDRED CUBIC FEET
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CL CENTER LINE
CLG CEILING
CO CLEAN OUT
CONTR CONTRACTOR
CONV CONVECTOR
CUH CABINET UNIT HEATER
CW COLD WATER
DB DECIBEL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIFF DIFFUSER
DISCH DISCHARGE
DMPR DAMPER
DN DOWN
DR DRAIN
DSN DOWNSPOUT NOZZLE
DWG DRAWING
EAT ENTERING AIR TEMPERATURE
EDR EQUIVALENT DIRECT RADIATION
EP ELECTRIC-PNEUMATIC
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EXP EXPANSION
F FAHRENHEIT
FC FAN COIL
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FHC FIRE HOSE CABINET
FHR FIRE HOSE RACK
FLR FLOOR
FLEX FLEXIBLE
FM FIRE MAIN
FPM FEET PER MINUTE
FPS FEET PER SECOND
FT FEET OR FOOT
F&T FLOAT AND THERMOSTATIC
FTG FOOTING
FTR FINNED TUBE RADIATION
FV FACE VELOCITY
GA GAUGE
GAL GALLON
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HB HOSE BIBB
HD HEAD
HOA HANDS-OFF-AUTOMATIC
HTG HEATING
HTR HEATER
HVAC
HEATING, VENTILATION,
AND AIR CONDITIONING
HYD HYDRANT
HW HOT WATER
GCO GRADE CLEANOUT
INSUL INSULATION
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
LWT LEAVING WATER TEMPERATURE
MBH BTU PER HOUR (THOUSANDS)
MCF THOUSAND CUBIC FEET
MH MANHOLE
NC NOISE CRITERIA OR
NORMALLY CLOSED
NEG NEGATIVE
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
ORD OVERFLOW ROOF DRAIN
PD PRESSURE DROP OR DIFFERENCE
PE PNEUMATIC-ELECTRIC
PLBG PLUMBING
PRV PRESSURE REDUCING VALVE
OR POWER ROOF VENTILATOR
PSIA POUNDS/SQ INCH ABSOLUTE
PSIG POUNDS/SQ INCH GAUGE
PVC POLY VINYL CHLORIDE
RA RETURN AIR
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RECIRC RECIRCULATING
REG REGISTER
RET RETURN
RH RELATIVE HUMIDITY
RHT REHEAT
RHC REHEAT COIL
RHW RECIRCULATED HOT WATER
RM ROOM
RPM REVOLUTIONS PER MINUTE
RPZ REDUCED ZONE BACKFLOW
PREVENTER
SA SUPPLY AIR
SAN SANITARY
SCFM CFM, STANDARD CONDITIONS
SD SMOKE DAMPER
SP STATIC PRESSURE
SPECS SPECIFICATIONS
SUP SUPPLY
SQ SQUARE
STM STEAM
TD TEMPERATURE DIFFERENCE
TEMP TEMPERATURE
TONS TONS OF REFRIGERATION
T-STAT THERMOSTAT
TYP TYPICAL
UB UP-BLAST
UG UNDERGROUND
UH UNIT HEATER
UR URINAL
V SANITARY VENT
VD VOLUME DAMPER
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W SANITARY WASTE
W/ WITH
WC WATER CLOSET
WCO WALL CLEANOUT
WH WALL HYDRANT
W/O WITHOUT
WTR WATER
GR GRILLE
VAV VARIABLE AIR VOLUME
VTR VENT THROUGH ROOF
INV INVERT
RLF RELIEF
ISO ISOLATION EXHAUST
GEXH GREASE EXHAUST
RH ROOF HYDRANT
YCO YARD CLEANOUT
ZDL ZERO DEADLEG VALVE
BALANCE VALVE
NITROGEN OXIDE SENSORNOX
I HEREBY CERTIFY THAT THIS
PLAN, SPECIFICATION, OR
REPORT WAS PREPARED BY ME
OR UNDER MY DIRECT
SUPERVISION AND THAT I AM A
DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE
OF MINNESOTA.
NUMBER DATE
Steve C. Harmon
23501
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
OF SHEETS
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CD ISSUE 03/10/26
KEY PLAN
03/10/2026
421 First Avenue SW / Suite 201W Rochester, MN 55902 Phone: 507.424.6850 www.dunhameng.com
Dunham Proj. 1225052-000-00
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry
C o m m u n it y R e s o u rc e R o o m
R e m o d e l/ M
E P
G a g e
E le m e n ta ry R e s o u rc e R o o m
R e m o d e l_ o w e n
.n o rd
.r v t
/9
/2
:1
:4
P M
M000
MECHANICAL SYMBOLS AND
ABBREVIATIONS
R O
C H
E S
T
R
M
IN
N E
S O
T A
R o ch e st e r P u b lic S ch o o ls
G a g e
E le m e n ta ry R e so u rc e R o o m R e m o d e l
1225052-000-00
03/10/2026
MJS
SCH
MECHANICAL SHEET LIST
SHEET
NUMBER SHEET NAME
M000 MECHANICAL SYMBOLS AND ABBREVIATIONS
xM880 VENTILATION MATRIX AND DAMPER MATRIX
MD100 LEVEL 1 - MECHANICAL DEMOLITION PLAN
M100 LEVEL 1 - MECHANICAL PLAN
ME100 MECHANICAL AND ELECTRICAL SCHEDULES
FD100 LEVEL 1 - FIRE PROTECTION DEMOLITION PLAN
F100 LEVEL 1 - FIRE PROTECTION PLAN
P100 UNDERFLOOR PLUMBING PLAN
P101 LEVEL 1 - PLUMBING PLAN
P200 PLUMBING RISERS, DETAILS AND SCHEDULES
SHEET TOTAL: 10
KEY NOTES:
1 1
1 1
1 1
3 3
EDGE OF SOFFIT
EDGE OF SOFFIT
/2
F
/2
F
CLASSROOM
MEDIA
CENTER
RESOURCE
ROOM
PENDANT SPRINKLER HEAD TO REMAIN.
SIDEWALL SPRINKLER HEAD TO REMAIN.
DEMOLISH PENDANT SPRINKLER HEAD AND BRANCH PIPING BACK TO
MAIN AND CAP.
DEMOLISH SIDEWALL SPRINKLER HEAD AND BRANCH PIPING BACK TO
MAIN AND CAP.
DEMOLISH SECTION OF PIPE AS SHOWN.
I HEREBY CERTIFY THAT THIS
PLAN, SPECIFICATION, OR
REPORT WAS PREPARED BY ME
OR UNDER MY DIRECT
SUPERVISION AND THAT I AM A
DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE
OF MINNESOTA.
NUMBER DATE
Steve C. Harmon
23501
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
OF SHEETS
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CD ISSUE 03/10/26
KEY PLAN
03/10/2026
421 First Avenue SW / Suite 201W Rochester, MN 55902 Phone: 507.424.6850 www.dunhameng.com
Dunham Proj. 1225052-000-00
A u to d e s k D o c s /R
P S
G a g e E le m e n ta ry
C o m m u n it y R e s o u rc e R o o m
R e m o d e l/ M
E P
G a g e
E le m e n ta ry R e s o u rc e R o o m
R e m o d e l_ o w e n
.n o rd
.r v t
/9
/2
:1
:4
P M
FD100
LEVEL 1 - FIRE PROTECTION
DEMOLITION PLAN
R O
C H
E S
T
N E
S O
T A
R o ch e st e r P u b lic S ch o o ls
G a g e
E le m e n ta ry R e so u rc e R o o m R e m o d e l
1225052-000-00
03/10/2026
MJS
SCH
1/4" = 1'-0"
LEVEL 1 - FIRE PROTECTION DEMOLITION PLAN
1 1
1 1
1 1
EDGE OF SOFFIT
3 5
3 3
CLASSROOM
RESOURCE
ROOM
214C
MEDIA
CENTER
FACS ROOM
PENDANT SPRINKLER HEAD TO REMAIN.
SIDEWALL SPRINKLER HEAD TO REMAIN.
PROVIDE SEMI-RECESSED SPRINKLER HEAD TO MATCH EXISTING.
PROVIDE BRANCH PIPING CONNECTED TO EXISTING MAIN.
OFFSET PIPE OVER NEW EXHAUST DUCT. PROVIDE AUXILIARY DRAIN.
PROVIDE 212F SPRINKLER HEAD.
I HEREBY CERTIFY THAT THIS
PLAN, SPECIFICATION, OR
REPORT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .