This statement of work outlines the requirements for a nonpersonal services contract to provide preventive maintenance and emergency repair services for a Kolene Molten Salt Bath Cleaning System located at Anniston Army Depot in Alabama. The contractor shall provide onsite preventive maintenance services quarterly and respond to emergency repair requests within 48 hours of notification. Services include inspection, adjustments, minor repairs, and reporting on the salt bath condition and chemistry. The contract term is one base year with four one-year options. The contractor must use OEM parts and invoice actual costs for labor, travel expenses including per diem, and parts. Upon emergency repairs, the contractor must report corrective actions taken. The contractor must comply with environmental laws and not use ozone depleting substances. Communications shall be between the contractor and contracting officer at Anniston Army Depot.
The related sole-source federal contract opportunity is for the preventive maintenance and repair services described in the statement of work. The solicitation is issued by the Department of the Army Materiel Command Contracting Command Detroit Arsenal for support of the Kolene Molten Salt Bath Cleaning System at Anniston Army Depot. The acquisition is sole-sourced to Kolene Corporation as the OEM.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK/SPECIFICATION FOR
KOLENE MOLTEN SALT BATH CLEANING SYSTEM PREVENTIVE
MAINTENANCE AND EMERGENCY REPAIR SERVICES
1. SCOPE: The specification establishes the requirements for on-site preventive maintenance and emergency repair services for one (1) each Government owned Kolene Molten Salt Bath Cleaning System, Unit Serial Number 1040, located in building 474 at Anniston Army Depot, Anniston, Alabama. The on-site preventive maintenance and emergency repair support coverage shall be for a one-year base period beginning at contract award, plus four (4) one-year options.
The support shall be renewable yearly on a one-year basis.
2. REQUIREMENTS: The contractor shall provide on-site preventive maintenance and emergency repair services for the Kolene Molten Salt Bath Cleaning System including all labor, equipment, special tools, materials, documentation, transportation, schematics, common tools of the trade, and any other items necessary to provide the required support. The contractor shall provide trained personnel with the necessary expertise to perform all required technical support and on-site preventive and emergency corrective maintenance services on the Kolene Molten Salt Bath Cleaning System. The contractor shall provide necessary repair parts and invoice the Government separately for such repair parts.
3. PRINCIPLE PERIOD OF MAINTENANCE (PPM): The normal period of on-site preventive maintenance and emergency repair services shall be from 7:00 AM -4:30 PM Monday through Thursday and 7:00AM- 3:30PM every other Friday. No hours on Saturday, Sunday or Government observed holidays. The contractor shall make every effort to make all repairs during the scheduled PPM visits. Any circumstances that require an extension of maintenance services beyond the scheduled PPM visit or will result in additional costs to the Government shall be approved by the Contracting Officer or Contracting Officer's Representative (COR) before the services are performed.
4. PREVENTIVE MAINTENANCE SERVICES: The contractor shall perform quarterly preventive maintenance services (4 times per year) on the Kolene Molten Salt Bath Cleaning System. All work shall be performed in accordance with the original equipment manufacturer (OEM) procedures, guidelines, and schedules for quarterly, semi-annual, and annual maintenance service requirements. The contractor shall perform all tasks to properly maintain and service the Kolene Molten Salt Bath Cleaning System to keep it operating at full production level and provide the maximum performance and service life for the equipment. Each scheduled preventive maintenance service shall include but not be limited to the following:
• Complete salt cleaning system inspection with necessary adjustments and minor repairs for optimum equipment performance and safety evaluation.
• Handling system evaluation, adjustment, and minor repairs.
• Pollution abatement system evaluation, adjustment, and minor repairs.
• When performing maintenance on Kolene Molten Salt Bath Cleaning System heaters contractor shall fill out inspection form “Tune Up Procedures for Boilers/Process Heaters” as required by 40 CFR Part 63 Subpart DDDDD. Completed form shall be provided to the COR as part of the preventive maintenance inspection report.
• Provide a detailed written report of the preventive maintenance inspection and recommendations for operation.
• Salt bath and KLC Brightener samples shall be taken for analysis and a report of the salt condition and KLC bath chemistry condition shall be provided to the COR as part of the preventive maintenance inspection report.
5. EMERGENCY REPAIRS: The contractor shall perform on-site emergency repairs for the Kolene Molten Salt Bath Cleaning System on a high priority basis during and outside the PPM (Ref. Para 3). The contractor shall acknowledge the Government's request for on-site emergency repairs or other on-site technical support from the Contracting Officer or COR within twenty-four (24) hours after notification. Contractor personnel shall arrive at Anniston Army Depot, Alabama within forty-eight (48) hours after notification that onsite emergency repair services are needed unless otherwise coordinated with the COR.
The contractor shall have the expertise to provide a timely diagnosis of malfunctions and complete all repairs to return the Kolene Molten Salt Bath Cleaning System to 100% production capable readiness.
There shall be no charge to the Government for the same repair performed within 90 calendar days after the original repair is made.
6. PARTS: Only new OEM repair parts shall be used to repair the Kolene Molten Salt Bath Cleaning System. Replacement parts shall be supplied by the Contractor on a cost reimbursement basis and pricing shall be consistent with the Contractor’s published prices that are in effect at the time of service. All replaced parts or components shall remain the property of the Government.
7. INVOICING: All associated costs including labor, travel, lodging, equipment, repair parts, etc. must be submitted to the Government on an itemized invoices. Travel expenses shall include hourly travel rate plus per diem, airfare and rental vehicle. Airfare and rental vehicle will be reimbursed at actual costs. Anniston Army Depot will not pay more than the per diem for lodging and meals. All other travel expenses (mileage, parking, and per diem) will be reimbursed in accordance with Joint Travel Regulations (JTR) and receipts submitted to the Contracting Officer for actual travel expenses.
8. DOCUMENTATION OF EMERGENCY REPAIR SERVICES: Upon completion of each emergency repair service the contractor shall provide a written report detailing the corrective actions taken to repair the Kolene Molten Salt Bath Cleaning System. The report shall include as minimum the following information:
A. Date and time of notification.
B. Date and time of arrival on-site.
C. Time spent for repair.
D. Description of malfunction(s) and maintenance/corrective actions performed.
E. List and description of parts replaced.
9. ENVIRONMENTAL: The contractor will comply with all relevant and applicable federal state, local and environmental laws and regulations. Disposal of all wastes shall be in compliance with such laws and regulations. The Contractor shall not use any ozone depleting substances (ODS). The contractor shall clean up any spill which occurs during the service event that is a result of contractor operations.
10. CONTRACTOR' S POINT OF CONTACT: The Contractor shall provide the Government the name and telephone number of a designated POC and shall make arrangements that will enable their service personnel to receive notifications of service requests.
11. TECHNICAL/CONTRACT LIAISON: The Contracting Officer Representative (COR) will be responsible for surveying all services of the Contractor. Communications or correspondence of contract matters including invoicing shall be between the Contractor and the Contracting Officer, Anniston Army Depot, ATTN: ACC-ANAD, 7 Frankford Avenue, Bldg.
35, Anniston , AL 36201-4199.
The Contractor shall not proceed with any verbal or written change(s) to the scope of work from sources other than the Contracting Officer, who will provide changes in writing.
Tune Up Procedures for Boilers/Process Heaters
Date: ___________________________________________
Boiler/Process Heater Operator: ______________________
Boiler/Process Heater ID: ___________________________
Tune-Up Conducted By: ____________________________
Meter Reading (1): ___________________________________
Requirement Description Inspector Comments/Corrective Actions Taken
As applicable, inspect burner
Clean or replace any components of the burner as necessary
As applicable, inspect flame pattern
Adjust the burner as necessary to optimize the flame pattern. The adjustment should be consistent with manufacturer’s specifications is available
As applicable, inspect air-to-fuel ratio control system
Ensure system is calibrated and functioning properly
Optimize total emissions of Carbon Monoxide
(CO)
Optimize emissions consistent with the manufacturer’s specifications, if available.
Measure CO and O2 levels in exhaust, before and after tune-up
Parameter Before After Basis (wet or dry)
CO
(PPMV)
O2 (% by Volume)
(1) Write down the type and amount of fuel used over the 12-month period prior to the tune-up, but only if the unit was physically and legally capable of using more than one type of fuel during that period. Units that share a fuel meter may estimate the fuel used by each unit.