1 BDoc Civil Drawings pgs 1-10.pdf
PDF 15 MB Posted
- Solicitation number
- 36C24822R0026
About this file
This federal contract opportunity notice seeks construction services for a water main upgrade project at the Miami VA Healthcare System. The Department of Veterans Affairs Network Contracting Office 8 is seeking sources to award a fixed-price contract to replace and upgrade the water mains to Building 1, which were installed in 1967 and are in poor condition. The project scope includes analyzing the need to replace isolation valves and addressing leaks that have developed in water mains running in building crawl spaces and chases. The solicitation number is 36C24822R0026 and proposals are due by January 6, 2022 at 10:00 AM. The related file contains civil drawings pages 1 through 10 to support the project description.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24822R0026 0001.pdf | ||
| 3 BDoc Structural Draw.pdf | ||
| 1 BDoc Civil Drawings pgs 11-15.pdf | ||
| 5 BDoc Plumbing Drawing.pdf | ||
| 4 BDocs Architectural .pdf | ||
| 0 BDocs General Drawings.pdf | ||
| 2 BDoc Abatement Drawi.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10.0'+/-
6.0'+/-
30.0' EASEMENT FOR
WAGNER CREEK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth,MN55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
REMOVE EXISTING 8"
TRANSITE (DOMESTIC)
WATERMAIN - MINIMUM
COVER OF 4 FEET
DEMOLITION AND REMOVALS PLAN
- WEST
D-1
PROTECT AND
MAINTAIN EXISTING 8"
(FIRE) WATERMAIN
REMOVE AND REPLACE EXISTING
CONCRETE CURB AND GUTTER.
FULL DEPTH SAWCUT TO NEAREST
JOINT LINE - FIELD LOCATE.
REMOVE AND REPLACE EXISTING
BITUMINOUS PAVEMENT - FIELD
VERIFY AND LOCATE
PROTECT AND MAINTAIN
CONCRETE SIDEWALK
AND CURB AND GUTTER
LEGEND
M
ATC
H
LIN
E A-A
PROTECT AND MAINTAIN EXISTING
STANDING VALVE RACK (TYP.) - SEE
SHEET C-7 - SITE PHOTOGRAPHS 1
PROTECT AND MAINTAIN EXISTING
STANDING VALVE RACK (TYP.) - SEE
SHEET C-7 - SITE PHOTOGRAPHS 1
FULL DEPTH SAWCUT FOR
PROPOSED IMPROVEMENTS
- FIELD LOCATE
REMOVE EXISTING 4"
(DOMESTIC/FIRE) WATER
SERVICE TO EXISTING VALVE
REMOVE,SALVAGE, AND
REPLACE EXISTING PARKING
BUMPERS/STOPS (TYP.)
PROPERTY LIMITS
FULL DEPTH SAWCUT
CONSTRUCTION LIMITS
EXISTING WATERMAIN
EXISTING STORM SEWER
EXISTING FENCE
EXISTING UNKNOWN UTILITY
EXISTING COMMUNICATION
EXISTING UNDERGROUND
ELECTRIC
EXISTING HYDRANT AND GV
EXISTING SANITARY MANHOLE
EXISTING STORM SEWER INLET
EXISTING TRAFFIC SIGNAL PULL
BOX
EXISTING TRANSFORMER
REMOVE EXISTING UTILITY LINE
REMOVE EXISTING ASPHALT
PAVEMENT
REMOVE EXISTING CONCRETE
WALK
REMOVE EXISTING VEGETATION
FILL AND ABANDON-IN-PLACE
EXISTING WATERMAIN
REMOVE EXISTING CONCRETE
C&G
FISHER HOUSE
BUILDING 41
WATER TOWER
BUILDING 1
PROTECT AND MAINTAIN LINES,
VALVES, ETC. TO/FROM WATER
TOWER - SEE SHEETS C-11 AND C-12
PROPERTY BOUNDARY (TYP.)
PROPERTY BOUNDARY (TYP.)
SEE MEP PLANS FOR
ADDITIONAL WORK
INSIDE THE BUILDING
CONTRACTOR SHALL MAINTAIN
A MINIMUM OF TWO (2) DRIVE
AISLES OPEN AT ALL TIMES TO
MAINTAIN THE MAJORITY OF
PARKING STALLS -
COORDINATE WITH VAs COR
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
AND APPROVED IN WRITING BY THE ENGINEER OF RECORD.
5.PRESERVE AND PROTECT ALL EXISTING TREES AND TURF.
6.DUST CONTROL SHALL BE REQUIRED DURING ALL CUTTING ACTIVITIES -
PAVEMENT, PIPE, ETC.
8.3'+/-
Project Number
Building Number
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth,MN55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
FILL AND ABANDON-IN-PLACE
EXISTING 8" TRANSITE
(DOMESTIC) WATERMAIN.
CONTRACTOR SHALL PROVIDE
LOCATION INFORMATION.
DEMOLITION AND REMOVALS PLAN
- CENTER
D-2
LEGEND
M
ATC
H
LIN
E A-A
M
ATC
H
LIN
E B-B
PROTECT AND MAINTAIN EXISTING
STANDING VALVE RACK (TYP.) - SEE
SHEET C-8 - SITE PHOTOGRAPHS 2
FILL AND ABANDON-IN-PLACE
EXISTING (DOMESTIC) WATER
SERVICE. CONTRACTOR
SHALL PROVIDE LOCATION
INFORMATION.
PROTECT AND MAINTAIN EXISTING
(DOMESTIC) WATER SERVICE -
FIELD VERIFY SIZE
FILL AND ABANDON-IN-PLACE
EXISTING 8" TRANSITE
(DOMESTIC) WATERMAIN
REMOVE EXISTING 8"
TRANSITE (DOMESTIC)
WATERMAIN - MINIMUM
COVER OF 4 FEET
PROTECT AND MAINTAIN CONTINUOUS
ACCESS TO LOADING DOCK AREA
THROUGHOUT CONSTRUCTION
REMOVE AND REPLACE EXISTING
CONCRETE LOADING DOCK
PAVEMENT. FULL DEPTH SAWCUT TO
NEAREST JOINT LINE - FIELD LOCATE.
PROPERTY LIMITS
FULL DEPTH SAWCUT
CONSTRUCTION LIMITS
EXISTING WATERMAIN
EXISTING STORM SEWER
EXISTING FENCE
EXISTING UNKNOWN UTILITY
EXISTING COMMUNICATION
EXISTING UNDERGROUND
ELECTRIC
EXISTING HYDRANT AND GV
EXISTING SANITARY MANHOLE
EXISTING STORM SEWER INLET
EXISTING TRAFFIC SIGNAL PULL
BOX
EXISTING TRANSFORMER
REMOVE EXISTING UTILITY LINE
REMOVE EXISTING ASPHALT
PAVEMENT
REMOVE EXISTING CONCRETE
WALK
REMOVE EXISTING VEGETATION
FILL AND ABANDON-IN-PLACE
EXISTING WATERMAIN
REMOVE EXISTING CONCRETE
C&G
BUILDING 7
BUILDING 1
BUILDING 41
SEE MEP PLANS FOR
ADDITIONAL WORK
INSIDE THE BUILDING
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
AND APPROVED IN WRITING BY THE ENGINEER OF RECORD.
5.PRESERVE AND PROTECT ALL EXISTING TREES AND TURF.
6.DUST CONTROL SHALL BE REQUIRED DURING ALL CUTTING ACTIVITIES -
PAVEMENT, PIPE, ETC.
DURING CONSTRUCTION, DUST
PROTECTION IS RECOMMENDED
IN THIS AREA DUE TO A SLIGHT
CHEMICAL CONTAMINATION;
WITH REMEDIATION TO AN
APPROXIMATE 5 FOOT DEPTH
REMOVE EXISTING
8" WATER VALVE.
CAP END.
PROTECT AND MAINTAIN EXISTING
MONITORING WELL (TYP.)
PROTECT AND MAINTAIN EXISTING
MONITORING WELL (TYP.)
PROTECT AND MAINTAIN EXISTING
ELECTRICAL LINE (TYP.)
Building Number
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth,MN55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
DEMOLITION AND REMOVALS PLAN
- EAST
D-3
REMOVE AND REPLACE EXISTING 8'
WIDE CONCRETE SIDEWALK. FULL
DEPTH SAWCUT TO NEAREST
JOINT LINE - FIELD VERIFY.
REMOVE AND REPLACE EXISTING
HEDGES, EDGING, AND
LANDSCAPING - FIELD VERIFY
REMOVE AND REPLACE EXISTING
BITUMINOUS PAVEMENT - FIELD
VERIFY AND LOCATE
LEGEND
PROPERTY LIMITS
FULL DEPTH SAWCUT
CONSTRUCTION LIMITS
EXISTING WATERMAIN
EXISTING STORM SEWER
EXISTING FENCE
EXISTING UNKNOWN UTILITY
EXISTING COMMUNICATION
EXISTING UNDERGROUND
ELECTRIC
EXISTING HYDRANT AND GV
EXISTING SANITARY MANHOLE
EXISTING STORM SEWER INLET
EXISTING TRAFFIC SIGNAL PULL
BOX
EXISTING TRANSFORMER
REMOVE EXISTING UTILITY LINE
REMOVE EXISTING ASPHALT
PAVEMENT
REMOVE EXISTING CONCRETE
WALK
REMOVE EXISTING VEGETATION
FILL AND ABANDON-IN-PLACE
EXISTING WATERMAIN
REMOVE EXISTING CONCRETE
C&G
6.0'+/-
10.0'+/-
M
ATC
H
LIN
E B-B
32.0'+/-
5.5'+/-
8.0'+/-
PROTECT AND MAINTAIN EXISTING
STANDING VALVE RACK (TYP.) - SEE
SHEET C-8 - SITE PHOTOGRAPHS 2
FULL DEPTH SAWCUT FOR
PROPOSED IMPROVEMENTS
- FIELD LOCATE
REMOVE AND REPLACE EXISTING
CONCRETE CURB AND GUTTER.
FULL DEPTH SAWCUT TO NEAREST
JOINT LINE - FIELD LOCATE.
REMOVE AND REPLACE EXISTING
CONCRETE CURB AND GUTTER.
FULL DEPTH SAWCUT TO NEAREST
JOINT LINE - FIELD LOCATE.
REMOVE, SALVAGE, AND
REPLACE EXISTING PARKING
BUMPERS/STOPS. (TYP.)
PROTECT AND MAINTAIN EXISTING
8" FIRE LINE AND VALVE
PROPERTY BOUNDARY
PROPERTY BOUNDARY
CONTRACTOR SHALL MAINTAIN
ACCESS TO SPINAL CORD
INJURY CENTER
BUILDING 1
FILL AND ABANDON-IN-PLACE
EXISTING 8" TRANSITE
(DOMESTIC) WATERMAIN.
CONTRACTOR SHALL PROVIDE
LOCATION INFORMATION.
REMOVE EXISTING 8"
TRANSITE (DOMESTIC)
WATERMAIN - MINIMUM
COVER OF 4 FEET
SEE MEP PLANS FOR
ADDITIONAL WORK
INSIDE THE BUILDING
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
REMOVE EXISTING
8" WATER VALVE
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
AND APPROVED IN WRITING BY THE ENGINEER OF RECORD.
5.PRESERVE AND PROTECT ALL EXISTING TREES AND TURF.
6.DUST CONTROL SHALL BE REQUIRED DURING ALL CUTTING ACTIVITIES -
PAVEMENT, PIPE, ETC.
30.0' EASEMENT FOR
WAGNER CREEK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
GRADING AND EROSION CONTROL
PLANS - WEST
C-1
LEGEND
PROPERTY LIMITS
FULL DEPTH SAWCUT
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTROUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
CONSTRUCTION LIMITS
EXISTING WATERMAIN
EXISTING STORM SEWER
EXISTING FENCE
EXISTING UNKNOWN UTILITY
EXISTING COMMUNICATION
EXISTING UNDERGROUND
ELECTRIC
EXISTING HYDRANT AND GV
EXISTING SANITARY MANHOLE
EXISTING STORM SEWER INLET
EXISTING TRAFFIC SIGNAL PULL
BOX
EXISTING TRANSFORMER
INLET PROTECTION
BIO-ROLL
EXISTING SPOT ELEVATION
MATCH EXISTING ELEVATION
M
ATC
H
LIN
E A-A
PROPERTY BOUNDARY (TYP.)
PROPERTY BOUNDARY (TYP.)
CONTRACTOR SHALL MAINTAIN
A MINIMUM OF TWO (2) DRIVE
AISLES OPEN AT ALL TIMES TO
MAINTAIN THE MAJORITY OF
PARKING STALLS -
COORDINATE WITH VAs COR
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
AND APPROVED IN WRITING BY THE ENGINEER OF RECORD.
5.PRESERVE AND PROTECT ALL EXISTING TREES AND TURF.
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
GRADING AND EROSION CONTROL
PLANS - CENTER
C-2
LEGEND
PROPERTY LIMITS
FULL DEPTH SAWCUT
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTROUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
CONSTRUCTION LIMITS
EXISTING WATERMAIN
EXISTING STORM SEWER
EXISTING FENCE
EXISTING UNKNOWN UTILITY
EXISTING COMMUNICATION
EXISTING UNDERGROUND
ELECTRIC
EXISTING HYDRANT AND GV
EXISTING SANITARY MANHOLE
EXISTING STORM SEWER INLET
EXISTING TRAFFIC SIGNAL PULL
BOX
EXISTING TRANSFORMER
INLET PROTECTION
BIO-ROLL
EXISTING SPOT ELEVATION
MATCH EXISTING ELEVATION
M
ATC
H
LIN
E A-A
M
ATC
H
LIN
E B-B
PROTECT AND MAINTAIN CONTINUOUS
ACCESS TO LOADING DOCK AREA
THROUGHOUT CONSTRUCTION
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
AND APPROVED IN WRITING BY THE ENGINEER OF RECORD.
5.PRESERVE AND PROTECT ALL EXISTING TREES AND TURF.
DURING CONSTRUCTION, DUST
PROTECTION IS RECOMMENDED
IN THIS AREA DUE TO A SLIGHT
CHEMICAL CONTAMINATION;
WITH REMEDIATION TO AN
APPROXIMATE 5 FOOT DEPTH
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
GRADING AND EROSION CONTROL
PLANS - EAST
C-3
LEGEND
PROPERTY LIMITS
FULL DEPTH SAWCUT
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTROUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
CONSTRUCTION LIMITS
EXISTING WATERMAIN
EXISTING STORM SEWER
EXISTING FENCE
EXISTING UNKNOWN UTILITY
EXISTING COMMUNICATION
EXISTING UNDERGROUND
ELECTRIC
EXISTING HYDRANT AND GV
EXISTING SANITARY MANHOLE
EXISTING STORM SEWER INLET
EXISTING TRAFFIC SIGNAL PULL
BOX
EXISTING TRANSFORMER
INLET PROTECTION
BIO-ROLL
EXISTING SPOT ELEVATION
MATCH EXISTING ELEVATION
M
ATC
H
LIN
E B-B
CONTRACTOR SHALL MAINTAIN
ACCESS TO SPINAL
CORD INJURY CENTER
PROPERTY BOUNDARY (TYP.)
PROPERTY BOUNDARY (TYP.)
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
30.0' EASEMENT FOR
WAGNER CREEK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
SITE AND UTILITY PLANS - WEST
C-4
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
ADJACENT PROPERTY
BUILDING SETBACKS
PARKING SETBACK
DRAINAGE AND UTILITY
EASEMENT
PROPOSED CONCRETE C&G
PROPOSED BITUMINOUS
PAVEMENT
PROPOSED CONCRETE
PAVEMENT
NO PARKING ZONE
HANDICAP STALL DESIGNATION
NUMBER OF PARKING STALL IN
SECTION
406 LF 10" WM *
REPLACE CONCRETE
CURB AND GUTTER
- MATCH EXISTING
417.9'+/-
16.0'+/-
REPLACE PAVEMENT
STRIPING - MATCH
EXISTING (TYP.)
PROTECT AND MAINTAIN EXISTING
STANDING VALVE RACK (TYP.) - SEE
SHEET C-7 - SITE PHOTOGRAPHS 1
PROTECT AND MAINTAIN EXISTING
STANDING VALVE RACK (TYP.) - SEE
SHEET C-7 - SITE PHOTOGRAPHS 1
M
ATC
H
LIN
E A-A
REPLACE ASPHALT PAVING IN
KIND - MATCH EXISTING
STRUCTURE AND SEE DETAIL
ON SHEET C-6
REPLACE SALAVGED PARKING
BUMPERS/STOPS (TYP.) CONNECT TO EXISTING
8" VALVE w/ 8" TO 10" EXPANDER
- AS LIMIT OF CONSTRUCTION
PROTECT AND MAINTAIN
EXISTING 8" FIRE
WATERMAIN
CONNECT TO EXISTING
4" VALVE - AS LIMIT
OF CONSTRUCTION
CONNECT TO EXISTING
8" VALVE w/ 10" TO 8"
REDUCER - AS LIMIT
OF CONSTRUCTION
PROPERTY BOUNDARY (TYP.)
PROPERTY BOUNDARY (TYP.)
PROTECT AND MAINTAIN LINES,
VALVES, ETC. TO/FROM WATER
TOWER - SEE SHEETS C-11 AND C-12
* MINIMUM FOUR (4') FOOT COVER TO TOP OF PIPE
INSTALL 10"x10"x10" TEE
AND 10" TO 4" REDUCER -
FIELD VERIFY REDUCER
SEE MEP PLANS FOR
ADDITIONAL WORK
INSIDE THE BUILDING
CONTRACTOR SHALL
DETERMINE AND PROVIDE ALL
BENDS, FITTINGS, ETC. (TYP.)
CONTRACTOR SHALL
DETERMINE AND PROVIDE ALL
BENDS, FITTINGS, ETC. (TYP.)
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
AND APPROVED IN WRITING BY THE ENGINEER OF RECORD.
5.PRESERVE AND PROTECT ALL EXISTING TREES AND TURF.
CONTRACTOR SHALL MAINTAIN
A MINIMUM OF TWO (2) DRIVE
AISLES OPEN AT ALL TIMES TO
MAINTAIN THE MAJORITY OF
PARKING STALLS -
COORDINATE WITH VAs COR
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
SITE AND UTILITY PLANS - CENTER
C-5
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
ADJACENT PROPERTY
BUILDING SETBACKS
PARKING SETBACK
DRAINAGE AND UTILITY
EASEMENT
PROPOSED CONCRETE C&G
PROPOSED BITUMINOUS
PAVEMENT
PROPOSED CONCRETE
PAVEMENT
NO PARKING ZONE
HANDICAP STALL DESIGNATION
NUMBER OF PARKING STALL IN
SECTION
17.5'+/-
13.4'+/-
PROTECT AND MAINTAIN EXISTING
STANDING VALVE RACK (TYP.) - SEE
SHEET C-8 - SITE PHOTOGRAPHS 2
M
ATC
H
LIN
E A-A
M
ATC
H
LIN
E B-B
CONNECT TO EXISTING 8" DIP
WATER LINE AT EXISTING
COUPLING - FIELD LOCATE
PROTECT AND MAINTAIN CONTINUOUS
ACCESS TO LOADING DOCK AREA
THROUGHOUT CONSTRUCTION
INSTALL 24" LONG x 1" DIA.
DOWELS AT 18" O.C.;
REPLACE CONCRETE PAVING
IN KIND - MATCH EXISTING
STRUCTURE
CONNECT TO EXISTING 3"
UNDERGROUND ELBOW (+/- 6 LF) - AS
LIMIT OF CONSTRUCTION - SEE DETAIL
ON SHEET C-8 - SITE PHOTOGRAPHS 2
CONNECT TO EXISTING 4"
UNDERGROUND ELBOW (+/- 4 LF) - AS
LIMIT OF CONSTRUCTION - SEE DETAIL
ON SHEET C-8 - SITE PHOTOGRAPHS 2
* MINIMUM FOUR (4') FOOT COVER TO TOP OF
PIPE; AND INCLUDES LENGTH TO BUILDING FACE.
SEE MEP PLANS FOR
ADDITIONAL WORK
INSIDE THE BUILDING
+/- 20 LF 10" WM *
CONTRACTOR SHALL
DETERMINE AND PROVIDE ALL
BENDS, FITTINGS, ETC. (TYP.)
CONNECT TO EXISTING 6" VALVE - AS
LIMIT OF CONSTRUCTION - SEE DETAIL
ON SHEET C-8 - SITE PHOTOGRAPHS 2
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
AND APPROVED IN WRITING BY THE ENGINEER OF RECORD.
5.PRESERVE AND PROTECT ALL EXISTING TREES AND TURF.
DURING CONSTRUCTION, DUST
PROTECTION IS RECOMMENDED
IN THIS AREA DUE TO A SLIGHT
CHEMICAL CONTAMINATION;
WITH REMEDIATION TO AN
APPROXIMATE 5 FOOT DEPTH
+/- 49 LF 10" WM *
INSTALL BENEATH THE SHOWN
EXISTING ELECTRICAL LINE
CONTRACTOR SHALL
DETERMINE AND PROVIDE ALL
BENDS, FITTINGS, ETC. (TYP.)
CAP END AT TEE
26.4'+/-
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
020'40'
N
SITE AND UTILITY PLANS - EAST
C-6
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
ADJACENT PROPERTY
BUILDING SETBACKS
PARKING SETBACK
DRAINAGE AND UTILITY
EASEMENT
PROPOSED CONCRETE C&G
PROPOSED BITUMINOUS
PAVEMENT
PROPOSED CONCRETE
PAVEMENT
NO PARKING ZONE
HANDICAP STALL DESIGNATION
NUMBER OF PARKING STALL IN
SECTION
63.7'+/-
32.0'+/-
REPLACE PAVEMENT
STRIPING - MATCH
EXISTING (TYP.)
PROTECT AND MAINTAIN EXISTING
STANDING VALVE RACK (TYP.) - SEE
SHEET C-8 - SITE PHOTOGRAPHS 2
PAVEMENT PATCHING DETAIL
N.T.S.
EXISTING HMA OVERLAY
AND/OR SURFACE COURSE
- MATCH EXISTING (TYP.).
1 1/2" MINIMUM
EXISTING PAVEMENT MATCH EXISTING
PAVEMENT TYPE
- ADD DOWELS
AS NECESSARY
PER PLAN AND/OR AS
NEEDED (MINIMUM) -
TO NEAREST JOINT LINE
T
T + 2" (M
IN
FULL-DEPTH SAWCUT (TYP.)
12"
(MIN.)
12"
(MIN.)
IF SUBGRADE OR SUBBASE MATERIAL IS
REQUIRED BELOW PATCH, BRING MATERIAL TO
A LEVEL TWO (2") INCHES BELOW BOTTOM OF
EXISTING PAVEMENT (TYP.)
M
ATC
H
LIN
E B-B
REPLACE CONCRETE
SIDEWALK - MATCH EXISTING
REPLACE CONCRETE
CURB AND GUTTER
- MATCH EXISTING
REPLACE HEDGES,
EDGING, AND
LANDSCAPING (TYP.)
REPLACE SALVAGED PARKING
BUMPERS/STOPS (TYP.)
REPLACE ASPHALT PAVING IN
KIND - MATCH EXISTING
STRUCTURE AND SEE DETAIL
ON THIS SHEET
83 LF 10" WM *
PROPERTY BOUNDARY (TYP.)
PROPERTY BOUNDARY (TYP.)
CONTRACTOR SHALL
MAINTAIN ACCESS TO
SPINAL INJURY CENTER
PROTECT AND
MAINTAIN EXISTING 8"
FIRE LINE AND VALVE
SEE MEP PLANS FOR
BUILDING FOUNDATION
PENETRATION INFORMATION
10" VALVE IN PAVMENT -
12" +/- FROM CURBING
CONNECT TO EXISTING 8"
UNDERGROUND ELBOW w/
8" TO 10" EXPANDER - AS
LIMIT OF CONSTRUCTION
* MINIMUM FOUR (4') FOOT COVER TO TOP OF
PIPE; AND INCLUDES LENGTH TO BUILDING FACE.
SEE MEP PLANS FOR
ADDITIONAL WORK
INSIDE THE BUILDING
CONTRACTOR SHALL
DETERMINE AND PROVIDE ALL
BENDS, FITTINGS, ETC. (TYP.)
SURVEY NOTES:
1.FIELD TOPOGRAPHIC SURVEY, UTILITY LOCATES, ETC. HAVE BEEN COMPLETED
(SHOWN 'BLACK') BY MILLER LEGG. ADDITIONAL UTILITY LOCATION(S) ARE
FROM VA SUPPLIED CAD FILES (SHOWN 'GRAY SCALE').
2.THE LOCATION AND EXTENT OF UNDERGROUND UTILITIES, IF SHOWN, ARE
BASED UPON ABOVE GROUND EVIDENCE, A PRIVATE UTILITY LOCATE, AND
UTILITY DRAWINGS PROVIDED BY THE VA. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR THE COMPLETENESS OF THIS INFORMATION. THE SIZE AND
LOCATION SHOULD BE CONSIDERED APPROXIMATE. ADDITIONAL
UNDERGROUND UTILITIES MAY BE PRESENT. VERIFICATION OF THE EXISTENCE
AND LOCATION OF ALL UTILITIES SHOULD BE OBTAINED FROM THE UTILITY
OWNERS PRIOR TO ANY PLANNING OR DESIGN. THE LOCATION OF THE
UTILITIES SHALL BE CONFIRMED PRIOR TO ANY DEMOLITION OR
CONSTRUCTION.
3.IRRIGATION HEADS, LINES, ETC. MAY BE FOUND THROUGHOUT THE VAMC
CAMPUS; AND ARE NOT SHOWN HEREIN FOR CLARITY.
4.CONTRACTOR(S) SHALL VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO
PERFORMING ANY ACTIVITIES AND/OR OPERATIONS. PRESERVE AND PROTECT
ALL EXISTING TREES AND TURF.
GENERAL NOTES:
1.COORDINATE WITH VAs COR FOR PROJECT PHASING; AND FOR PROJECT
WORK, STAGING, STORAGE, ETC. AREAS.
2.SHORING FOR BUILDING AND/OR UTILITY EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR; AND AS APPROVED IN WRITING BY THE
OWNER'S REPRESENTATIVE AND THE ENGINEER PRIOR TO CONSTRUCTION
ACTIVITIES.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT
CONSTRUCTION AND SHALL SUBMIT THESE AS-BUILT PLANS TO THE ENGINEER
UPON COMPLETION OF WORK.
4.SUBSTITUTIONS FROM INFORMATION SHOWN HEREIN SHALL BE REVIEWED
Drawing Number
Project Title
Location
Issue DateCheckedDrawn
Drawing Title
Approved:
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
2 145678910
Phase
ARCHITECT/ENGINEER OF RECORDSTAMP CONSULTANT
3 2 145678910
UPGRADE WATER MAINS TO
BUILDING 1 FCA-D
MIAMI VAMC, FL
546-19-102
Project Director
07-08-2020JRKMLT Revisions:Date:
13605 1st Ave. N. #100 Plymouth, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj #
JAY
RONALD KOESTER LICENSE
FLORIDA
SITE PHOTOGRAPHS 1
C-7
1WEST STANDING VALVE RACK @ NW 14TH AVENUE - LOOKING WESTERLY
NO SCALE3VALVE CONNECTION - LOOKING NORTHEASTERLY
NO SCALE
4VALVE CONNECTION - LOOKING EASTERLY
NO SCALE5STANDING VALVE RACKS WEST OF BUILDING 41 - LOOKING EASTERLY
NO SCALE6STANDING VALVE RACKS WEST OF BUILDING 41 - LOOKING EASTERLY
NO SCALE
2FISHER HOUSE SERVICE VALVE - LOOKING SOUTHERLY
NO SCALE
EXISTING VALVE IS LIMIT
OF CONSTRUCTION
EXISTING VALVE IS LIMIT
OF CONSTRUCTION
EXISTING VALVE IS LIMIT
OF CONSTRUCTION
EXISTING VALVE (FOR
FISHER HOUSE) IS LIMIT
OF CONSTRUCTION
EXISTING STANDING VALVE
RACKS ON OPPOSITE SIDE
OF WALL
NW 14TH AVENUE
(BEYOND FENCE)
FISHER HOUSE
EXISTING VALVE TO/FROM
EXISTING WATER TOWER
WATER TOWER
EXISTING VALVE TO/FROM
EXISTING WATER TOWER
NOTES:
1.PHOTOGRAPHS WERE TAKEN BY ANDERSON ENGINEERING OF MN, LLC ON
FEBRUARY 19TH AND 20TH, 2020.
EXISTING TRENCH CUT
BETWEEN STANDING VALVE
RACK AND BUILDING 41
File details come from the government source that posted it. Updated .