The file's text, extracted by GovTribe without its formatting.
ATTACHMENT C
FUNCTIONAL CAPABILITIES
The terms “System”, “Software”, and “Application” are used throughout this attachment. These terms are meant to represent the Consultant’s proposed software and infrastructure, as applicable.
1. Consultant must respond to each individual line item by entering an ‘X’ in one of the columns provided. Select the appropriate response using the following guidelines below.
| Standard |
| The capability is satisfied by the System proposed. |
· If the System requires specialized configuration, Consultant must enter required configurations in the “Describe” section provided.
· If the capability is satisfied by third-party software, please indicate the third-party product proposed.
| Customization |
| A modification to the System is required to provide the capability. |
· Consultant must provide an explanation of the work required to perform the modification in the “Describe” section provided.
| Not Available |
| The System does not provide the capability as written. |
2. Consultant must provide an explanation of how the line item will be satisfied.
| Describe |
| · If capability is met by more than one module, Consultant must list which module or modules are required to provide the capability. |
· Consultant may also include screen shots, diagrams, samples, and inventories for any capabilities listed.
· If unable to provide the capability as written, Consultant must offer a brief explanation or propose an alternative way to provide it.
| Ref. No |
| Capabilities |
| Standard |
| Customization |
| Not Available |
| Describe |
| 1.1 |
| The system must integrate with the City’s Central Square CAD system. |
1.2
Describe any history of deployments integrating with Central Square CAD environments, including any specific middleware, interface licensing, or partner certifications required from Central Square to achieve end-to-end functionality.
1.3
The system must ingest and interpret CAD incident data in real time without operational delay.
| 1.4 |
| The system must support presenting dispatch notifications using CAD data fields selected and configured by the City, including but not limited to date & time, station(s), rig(s)/unit(s), incident type, and incident address. |
| 1.5 |
| The system must use CAD incident data to determine and initiate the appropriate alerting workflows. |
| 1.6 |
| The system must support alerts directed to single units, multiple units, entire stations, and dispatch groups. |
| 1.7 |
| The system must support simultaneous alerts for multiple concurrent incidents. |
| 1.8 |
| The system must support multiple alert zones and assignment of rigs/units to zones. |
| 1.9 |
| System must be able to assign (and easily reassign) multiple rigs to each zone. |
| 1.10 |
| Describe how the system activates correct zones within each station, since CAD dispatches units but does not identify zones. |
| 1.11 |
| The system must maintain rig identifier mapping, using CAD as authoritative. |
| 1.12 |
| The system should provide manual alerting capability when CAD is unavailable. |
| 1.13 |
| The system must activate the appropriate in‑station alerting components, including lights, speakers, and rig notification interfaces, based on the alert workflow initiated from the CAD incident data. |
| 1.14 |
| The system must send immediate, automated, bidirectional electronic acknowledgments back to Central Square CAD confirming successful alert receipt, populating dispatch console timestamps automatically. |
| 1.15 |
| The system must allow configurable rules that modify alerting tone selection based on incident attributes such as call type, priority, or response mode. |
| 2. |
| All Broadcast – Chatter |
| 2.1 |
| The system must route dispatch audio to the station’s chatter speaker network or to a replacement chatter-capable audio system. |
| 2.2 |
| Describe how dispatch audio is routed to the chatter speaker system. |
| 2.3 |
| Chatter audio must remain continuously available and must continue operating during alerting system downtime, maintenance periods, or controller reboot events. |
| 2.4 |
| Chatter audio must not depend on alert workflows, tone activation, zone activation, or any other alerting behavior. |
| 2.5 |
| Chatter audio must broadcast all dispatch radio traffic so that personnel can monitor activity for all stations and units, not only those assigned to the current incident. |
| 2.6 |
| The system must support delivering chatter audio to station areas designated by the City and must allow the City to control which station areas receive chatter audio. |
| 2.7 |
| The system must allow the City to adjust chatter audio volume for each area and for each individual speaker, including both default volume levels and active operating levels. |
| 2.8 |
| The system must maintain chatter audio with minimal interruptions and must automatically recover from temporary loss of the audio source. |
| 2.9 |
| The system must support receiving audio from multiple dispatch radio channels and must allow the City to choose which of those channels are sent to the chatter audio output. |
| 3.1 |
| The system must deliver automated dispatch audio to the stations assigned to the incident. |
| 3.2 |
| Describe how the new system will support dispatch audio to appropriate station. |
| 3.3 |
| The system must deliver dispatch audio to the correct alerting zones within each station based on unit assignment. |
| 3.4 |
| The system must support delivery of live dispatcher voice messages to the appropriate station zones during an incident. |
| 3.5 |
| The system must support delivery of multiple live dispatcher voice messages to appropriate zones during concurrent incidents. |
| 3.6 |
| The system must allow the City to adjust dispatch audio volume for each zone and each speaker. (Specific to dispatch audio.) |
| 3.7 |
| The system must support simultaneous dispatch audio delivery to multiple stations when multiple incidents occur at the same time. |
| 3.8 |
| The system must recover automatically from temporary loss of dispatch audio delivery caused by network disruptions or delayed CAD messages. |
| 4. |
| Multi-Zone Alerting & Responder Wellness |
| 4.1 |
| The system must support independent zone alerting so that only the zones assigned to the dispatched units receive audio and visual notifications. |
| 4.3 |
| The system must support device-specific or room-specific lighting behaviors to support different area/room needs within the same zone. |
| 4.4 |
| The system must provide visual display boards that show dispatch data, incident location maps, cross‑streets, and turnout timers in areas designated by the City. |
| 4.5 |
| The system should allow the City to configure which visual information elements appear on each display. |
| 4.6 |
| The system must support gradual audio volume increases at the start of an alert to reduce sleep disruption and physiological stress, including alert tones. |
| 4.7 |
| The system must support reduced audio volume profiles specified for each tone/audio type during nighttime periods defined by the City. |
| 4.8 |
| The system must support visual quiet modes on display boards, such as dimmed displays or low brightness indicators, during nighttime or low light conditions. |
| 4.11 |
| The system could support color-coded visual indicators for units or incident types, as configured by the City. |
| 4.12 |
| The system must ensure zoned alerting behavior works correctly when multiple incidents occur simultaneously. |
| 4.13 |
| The system must support the City in setting default and active volume levels for each zone. |
| 4.14 |
| The system must support the City in setting default and active lighting levels for each zone. |
| 4.15 |
| The system must support the City in adjusting ramp-up time for zoned audio based on firefighter wellness needs. |
| 4.16 |
| The system must support the City in adjusting ramp-up time length for zoned lighting based on firefighter wellness needs. |
| 4.17 |
| The system must support routing visual alert information to monitors located in bunkrooms, bays, dayrooms, hallways, and other areas designated by the City. |
| 4.18 |
| The system must support delivery of updated incident information to visual displays during alert progression. |
| 5. |
| Reliability, Redundancy, & Standards Compliance |
| 5.1 |
| The system must provide dispatchers with clear notification when any station fails to receive an alert. |
| 5.2 |
| The system must provide the City with status information showing whether each station is online or offline. |
| 5.3 |
| The system must allow alerts to queue and retry automatically when connectivity to a station is disrupted. |
| 5.4 |
| The system must maintain functional alerting behavior during CAD downtime by supporting a manual entry workflow. |
| 5.5 |
| The system must maintain alerting functionality during local station power interruptions when supported by station backup power. |
| 5.6 |
| MFD has a cooperative mutual aid relationship with the City of St. Paul. Interoperability is not required, but is strongly desired with the new alerting system. |