This is a Storm Sewer Repair General Notes attachment for the City of Wichita, Kansas, detailing construction specifications and requirements for SWS #774 Repairs at 13th Street North & I-135 and 13th Street North & Pennsylvania. The document outlines that contractors must field-verify all existing elevations, depths, lengths, sizes, materials, and utility locations prior to construction, with any conflicting utilities to be adjusted by utility owners unless otherwise specified. The project encompasses storm sewer pipe installation and repair work, including connections to existing storm structures, new storm sewer pipe installation, structure backfill, lids, saw cutting, pipe bends, connections, fittings, grouting, and compaction for pipes of varying sizes (54" Cured-In-Place and 15"-18" Reinforced Concrete Pipe). All work, materials, and necessary repairs or relocations must be approved by the field engineer prior to construction and paid under designated bid items including "Pipe, SWS 54" Cured-In-Place," "Pipe, SWS 15" RCP," and "Pipe, SWS 18" RCP."

The contractor is responsible for site restoration as a lump sum bid item, which includes repair or replacement of any existing features damaged during construction, such as drainage structures, utility lines, driveways, pavement, striping, landscaping, sod, irrigation systems, and lighting conduits. Traffic flow must be maintained throughout the project, requiring the contractor to develop a traffic control plan for approval by the City Traffic Engineer and ensure compliance with the Manual of Uniform Traffic Control Devices. The document includes sidewalk and curb and gutter remove-and-replace calculations, indicating that these site restoration elements are components of the overall project scope.

View the file

Other files

File Type Posted
2-BP 458-2022-085515.pdf PDF
3-260017 Bid Table.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Storm Sewer Repair General Notes

1. All existing elevations, depths, lengths, sizes, materials, and descriptions shown on plan sheets are for information only. The Contractor will field verify these items prior to construction.

2. The Contractor will field verify horizontal and vertical locations of all existing utilities prior to construction. Any conflicting utilities will be adjusted prior to construction by the utility owners, unless otherwise stated on the plans.

3. Any existing features that are damaged by construction including existing drainage structures or pipes, roof drains, utility lines, utility service lines, driveways, pavement, pavement striping, landscaping, sod, irrigation systems and lighting conduits will be repaired or replaced and paid for as lump sum bid item ‘Site Restoration’.

4. Any necessary work and materials needed to complete the project including connections to existing storm structures, new storm sewer pipe, storm sewer structure backfill, storm sewer structure lid, saw cutting, pipe bends, pipe connections and fittings, grouting, and pipe compaction will be paid for as bid item ‘Pipe, SWS 54” Cured-In-Place’, ‘Pipe, SWS 15” RCP’ or ‘Pipe, SWS 18” RCP’. Any items that need repairs or relocation will be approved by the field engineer prior to construction.

5. The flow of traffic must be maintained in all instances. The Contractor will be required to develop a traffic control plan and receive approval by the City Traffic Engineer prior to construction. Additionally, all work in the right-of-way or near expected traffic shall conform to the guidelines and rules of the “Manual of Uniform Traffic Control Devices”.

Sidewalk Remove and Replace Calculations

Curb & Gutter Remove and Replace Calculations

Sidewalk Remove and Replace Calculations

KFleming Text Box 6'

KFleming Text Box or existing joint (Typ)

KFleming