1 3-4 Collar Tech Data.pdf

PDF 84 KB Posted

Attached to
Men's Marine Corps Dress Blue Coat and Collars
Solicitation number
SPE1C1-23-R-0058
Issued by

View the file

Other files

File Type Posted
2 Inch Collar Tech Data.pdf PDF
Mens Marine Corps Blue Coat Tech Data.pdf PDF
MILC19516gAMEND1.pdf PDF
PGC02045__MIL-DTL-23486C.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PGC002045 CONTAINS REQUIREMENTS FOR THE FOLLOWING COLLAR, COAT IN ACCORDANCE TO THE

FOLLOWING DOCUMENTS:

MIL-C-23486 dated 30 MAY 2018 MIL-C-19516G dated 6 MARCH 1991 AND INTERIM AMENDMENT 1 dated 14 MAY 1992 PD-FBDCE dated 12 October 2016

COLLAR, COAT: POLY/WOOL, GABARDINE, DARK

BLUE SHADE 2312, 1-3/4 INCHES

PATTERN DATE: MIL-C-19516 dated 5 June 1989

PD-FBDCE dated 26 October 2017

INTERIM SPECIFICATION CHANGES TO MIL-C-23486, MIL-C-19516, AND PD-FBDCE:

PAGE 2 PARAGRAPH 2.3, NON-GOVERNMENT DOCUMENTS AFTER “(…ONLINE AT WWW.ASTM.ORG.)

SDL ATLAS

PART NUMBER 402985 – SLUB/KNOT REPLICA SET

(REPLICA SET IS AVAILABLE FOR PURCHASE FROM SDL ATLAS CUSTOMER SERVICE, 1-803-329-2110.)

PAGE 7 PARAGRAPH 3.3.9.2 AT THE END OF THE PARAGRAPH ADD

“NOTE: UNIVERSAL PRODUCT CODE INFORMATION THE GOVERMENT ASSIGNED UNIVERSAL PRODUCT CODE

(UPC) MUST BE PLACED ON ALL SHIPPING CARTONS ON WHICH THE NSN APPEARS.

THE FOLLOWING DEFECTS APPLY FOR BARCODE LABELS/TAGS:

BAR CODE OMITTED OR NOT READABLE BY SCANNER

HUMAN-READABLE INTERPRETATION (HRI) OMITTED OR ILLEGIBLE

NOT VISIBLE ON FOLDED, PACKAGED ITEM CAUSES DAMAGE TO THE ITEM

PAGE 23 AFTER PARAGRAPH 6.9 ADD THE FOLLOWING:

“PARAGRAPH 6.10 REPLICA SET. THE SDL ATLAS SLUB/KNOT REPLICA SET IS NOT AVAILABLE FROM THEIR

WEBSITE AT THIS TIME. RECOMMEND CALLING CUSTOMER SERVICE, 1-803-329-2110.

ADDITIONAL INFORMATION FOR A-A-52094A:

NO ADDITIONAL INFORMATION

(ref. T1481)

ADDITIONAL INFORMATION FOR A-A-50196:

(NO CURRENT CHANGES TO A-A-50196B)

ADDITIONAL INFORMATION FOR NN-P-71:

NO ADDITIONAL INFORMATION FOLLOWS..

ADDITIONAL INFO FOR UU-P-268: UU-P-268 IS CANCELLED.

USE A-A-203C DATED 1/3/96 AND A-A-1894A DATED 5/27/93.

(ref. T0688 - 9/11/06)

MIL-DTL-32075: LABEL FOR CLOTHING, EQUIPAGE,

AND TENTAGE, GENERAL USE REPLACES DDD-L-20

(Ref. T0451 - June 19, 2007)

INTERIM SPECIFICATION CHANGES TO MIL-DTL-32075:

PAGE 4, PARA. 3.3.5, AFTER "TYPE III OR IV, CLASS 4 OF" DELETE "DDD-L-20" AND REPLACE "MIL-DTL-32075,".

PAGE 6, TABLE I, "PHYSICAL REQUIREMENTS OF THE

TYPE VI FINISHED LABEL". UNDER "TEARING

STRENGTH" DELETE: "(LB.) MINIMUM" AND

SUBSTITUTE: "(GNS) MINIMUM".

PAGE 12, PARA 3.3.2.17, AFTER "NSN" ADD

"AND THE UNIVERSAL PRODUCT CODE (UPC)

SUPPLIED BY THE GOVERNMENT, FOR ALL NSN"s."

ADDITIONAL INFORMATION FOR MIL-C-368:

(USE OF IMPORTED YARN AUTHORIZED FOR

CLASS 1 CLOTH)

INTERIM CHANGES TO MIL-C-368J:

PAGE 2, PARA. 1.2, ADD THE FOLLOWING:

"CLASS 4 - TWILL, 3.7 OUNCE, RELAXED FINISH.".

PAGE 3, PARA. 2.2, ADD THE FOLLOWING:

"AATCC 20 - FIBER ANALYSIS: QUALITATIVE"

PAGE 4, TABLE I, UNDER "CLASS" COLUMN, DELETE

"1" AND SUBSTITUTE "1 AND 4".

PAGE 8, ADD THE FOLLOWING NEW SUBPARAGRAPH:

"3.8.1 RELAXED FINISH. CLASS 4 CLOTH SHALL HAVE

A RELAXED FINISH APPLIED ON A TENTER FRAME

DURING THE FINISHING PROCESS.".

PAGE 8, TABLE II, UNDER TEST METHOD COLUMN,

LINE 1, DELETE "1600" AND SUBSTITUTE "AATCC 20".

PAGE 8, TABLE II, ADD THE FOLLOWING:

"SHRINKAGE (CLASS 4) 3.8, 3.8.1 5580".

ADDITIONAL INFORMATION FOR MIL-F-495:

NO ADDITIONAL INFORMATION FOLLOWS.

ADDITIONAL INFORMATION FOR MIL-DTL-10176:

INTERIM SPECIFICATION CHANGES TO MIL-DTL-10176K:

3.7.3, LINE 2: DELETE "5.5" AND SUBSTITUTE "5.0"

ADD THE FOLLOWING PARAGRAPHS:

"3.7.4 WATER REPELLENT TREATMENT. WHEN SPECIFIED

, THE CLOTH SHALL BE GIVEN AN APPROVED DURABLE

FLUOROCHEMICAL TYPE WATER REPELLENT TREATMENT

AND SHALL CONFORM TO THE REQUIREMENTS

SPECIFIED IN 3.7.2 WHEN TESTED AS SPECIFIED IN

4.4.4.

3.7.4.1 SPRAY RATING. THE RESULTS OF THE THREE

INDIVIDUAL DETERMINATIONS ON THE SAMPLE UNIT FOR

SPRAY RATING SHALL BE EQUAL TO OR BETTER THAN

RATINGS OF 90,90,80 INITIALLY AND 80,80,70 AFTER

ONE DRYCLEANING WHEN TESTED AS SPECIFIED IN

4.4.4."

PAGE 9, PARAGRAPH 4.3.3.1 YARD-BY-YARD

EXAMINATION, LINE 3, DELETE "10" AND SUBSTITUTE

"7", LINE 4, DELETE "12" AND SUBSTITUTE "8"

TABLE II, BELOW "PH": ADD THE FOLLOWING UNDER

THEIR RESPECTIVE COLUMNS:

"WATER REPELLENCY:

SPRAY RATING:

INITIAL--------3.7.3.1---------5526

AFTER 1 DRYCLEANING----3.7.3.1---5508 AND 5526

SPONGING:

COLD WATER SPONGING IS REQUIRED. A PROPER

ALCOHOL WETTING AGENT SHALL BE USED TO INSURE

SHRINKAGE IS ACCOMPLISHED AND WATER RESISTANT

FINISH IS NOT RELEASED.

THE WATER REPELLANT TREATMENT MUST BE

APPLIED BEFORE THE SPONGING OPERATION.

ALL THE SPECIFICATION REQUIREMENTS MUST BE MET.

CODE OF FEDERAL REGULATIONS

16 CFR PART 1500- FEDERAL HAZARDOUS SUBSTANCES

ACT REGULATIONS.

29 CFR PART 1910- OCCUPATIONAL SAFETY AND HEALTH

STANDARDS.

(APPLICATIONS FOR COPIES OF REFERENCED

DOCUMENTS SHOULD BE ADDRESSED TO U.S

GOVERNMENT PRINTING OFFICE, SUPERINTENT OF

DOCUMENTS, MAIL STOP: SSOP, WASHINGTON, DC

20402-9328.)

PRINCIPLES AND METHODS OF TOXICOLOGY,

A. WALLACE HAYES (EDITOR), 1989, PP 394-396.

(APPLICATIONS FOR COPIES OF REFERENCED

DOCUMENTS SHOULD BE ADDRESSED TO RAVEN

PRESS,1185 AVENUE OF THE AMERICAS, NEW YORK,

NY 10036.)

TOXICITY. THE FINISHED CLOTH SHALL NOT

PRESENT A DERMAL HEALTH HAZARD WHEN USED

AS INTENDED.

TOXICITY ASSESSMENT. THE CONTRACTOR MUST

FURNISH INFORMATION WHICH CERTIFIES THAT

THE FINISHED PRODUCT IS COMPOSED OF MATERIALS

WHICH HAVE BEEN SAFELY USED COMMERCIALLY OR

PROVIDE SUFFICIENT TOXICITY DATA TO SHOW

COMPATIBILITY WITH PROLONGED, DIRECT SKIN

CONTACT. AT A MINIMUM, TOXICITY DATA SHOULD

INCLUDE RESULTS FROM A PRIMARY DERMAL IRRITATION

STUDY IN LABORATORY ANIMALS AND A REPEATED

INSULT HUMAN PATCH TEST (MODIFIED DRAIZE

PROCEDURE). THE LATTER MUST BE CONDUCTED UNDER

THE SUPERVISION OF A QUALIFIED DERMATOLOGIST

USING AT LEAST 100 FREE LIVING INDIVIDUALS.

File details come from the government source that posted it. Updated .