1-260068 Solicitation Document.pdf
PDF 989 KB Posted
- Attached to
- 39, 000 GVWR Dump Trucks
- Solicitation number
- 260068
- Issued by
- Sedgwick County, Kansas
About this file
This is a Request for Bid (RFB) solicitation document issued by the City of Wichita, Kansas, Public Works & Utilities Department, Fleet Division, seeking bids for the procurement of 39,000 GVWR cab and chassis dump trucks with twelve cubic yard dump beds installed. The City is requesting six units of new, unused, current model vehicles that meet detailed specifications including an L9 Cummins Diesel engine (330 horsepower), Allison 3000 RDS transmission, heavy-duty front and rear axles, air-operated disc brakes with ABS, and a comprehensive central hydraulic system capable of operating dump body hoists, material spreaders, and snow plows. Sealed bids must be submitted electronically through the City's Procurement Portal prior to 10:00 a.m. on Friday, April 17, 2026. Questions regarding the solicitation must be submitted via email to Jason Brogden (jbrogden@wichita.gov) no later than 3:00 p.m. on April 10, 2026, with answers provided through an addendum by the week of April 13, 2026. The tentative City Council award date is April 28, 2026. Successful bidders must deliver completed trucks F.O.B. destination to 1801 South McLean Boulevard, Wichita, Kansas, within 270 days of purchase order issuance, with liquidated damages of $100 per calendar day assessed for delays beyond this timeframe.
Award will be made to the lowest and best total net bid with options as selected from a responsible and responsive vendor. The solicitation includes six base bid options for alternative suspension systems (Chalmers or Haul Max rear suspension), wing panel dash, trade-in allowances for six identified 2008 International vehicles, alternative hydraulic systems (Force America), and alternative transmission-mounted PTO pump systems. The successful bidder must provide proof of warranty service capability within 30 miles of Wichita city limits, furnish two complete sets of operator's manuals and service/maintenance repair manuals, provide a minimum of four hours of on-site operator training and four hours of maintenance training at no additional cost to the City, and correct any deficiencies upon delivery at no expense to the City. The bidder must order the truck chassis within ten days of receiving the purchase order and provide the body builder with the chassis within 120 days, with the body builder completing installation within 150 days. All bids must be free of federal, state, and local taxes unless otherwise imposed by a governmental body, and vendor registration with the Kansas Secretary of State's Office is required before contract execution.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The City of Wichita is a leading-edge organization serving a dynamic and inclusive community.
City of Wichita 1 RFB #260068
(______________) Published on the City’s Website wichita.gov/legalnotices, Tuesday, March 24, 2026
REQUEST FOR BID NO. – 260068
Sealed Bids will be submitted electronically in the office of the City Purchasing Manager, 12th Floor, City Hall, 455 North Main, Wichita, Kansas, prior to 10:00 O'CLOCK A.M., FRIDAY, APRIL 17, 2026. “Request for Bid” form MUST be used to submit your bid unless you are submitting your bid on our website (wichita.gov/procurementportal) using your secured login/password to submit a bid for:
PUBLIC WORKS & UTILITIES DEPARTMENT/FLEET DIVISION
39,000 GVWR Cab and Chassis Dump Trucks
AS PER SPECIFICATIONS
F.O.B.: Wichita, KS
Bids will be opened after ten o’clock a.m., in the Board Room, 1st Floor, City Hall, 455 North Main, Wichita, Kansas.
Specifications and bid forms are on file in the office of the City Purchasing Manager, 12th Floor, City Hall, 455 N. Main, Wichita, Kansas 67202, (316) 268-4636. This information may also be obtained on our website above.
Dated at Wichita, Kansas this 24th day of March 2026.
Josh L. Lauber, MBA, CPSM Purchasing Manager https://www.wichita.gov/legalnotices https://wichita.bonfirehub.com/
City of Wichita 2 RFB #260068
CITY OF WICHITA
FINANCE DEPARTMENT/PURCHASING DIVISION
455 N. MAIN ST, 12TH FLOOR, WICHITA, KS 67202
PHONE: (316) 268-4636
WICHITA.GOV/PURCHASING
PURCHASING@WICHITA.GOV
WICHITA.GOV/PROCUREMENTPORTAL
REQUEST FOR BID #260068
39,000 GVWR Cab and Chassis Dump Truck
City of Wichita – Fleet Division
March 24, 2026
PROJECT DEFINITION
The City of Wichita is seeking bids from firm(s) for a 39,000 GVWR Cab and Chassis Dump Trucks with Twelve Cubic Yard Dump Bed Installed.
See Section II. Scope of Services; Meets/Not Meets Response Matrix for 39,000 GVWR Cab & Chassis Dump Trucks specifications.
THE AWARD WILL BE BASED ON THE LOWEST AND BEST TOTAL NET BID WITH OPTIONS AS
SELECTED.
Any questions may be submitted in writing to Jason Brogden (jbrogden@wichita.gov) no later than 3:00 p.m.
April 10, 2026. Questions must be submitted via email, and they will be answered through an addendum made available to all interested parties.
Tentative Schedule of Events Solicitation Advertised March 24, 2026 Questions Due Via Email April 10, 2026, 3:00 p.m.
Questions Answered Via Addendum Week of April 13, 2026 Bids Due April 17, 2026, 10:00 a.m.
City Council (tentative) April 28, 2026 https://www.wichita.gov/PURCHASING mailto:Purchasing@wichita.gov mailto:jbrogden@wichita.gov
City of Wichita 3 RFB #260068
Table of Contents
I. OVERVIEW AND SUMMARY
II. SCOPE OF SERVICES
III. BID TERMS
A. Questions and Contact Information:
B. Bid Submission:
C. Evaluation Criteria:
D. Tentative Schedule:
E. Minimum Respondent Qualifications:
F. Bid Requirements:
G. City of Wichita Responsibilities H. Challenges and Protests
IV. GENERAL SPECIFICATIONS:
City of Wichita 4 RFB #260068
I. OVERVIEW AND SUMMARY
The City of Wichita is the largest city in Kansas with a population of approximately 397,000 and is the seat of Sedgwick County. As of August 2020, the city’s total land area was approximately 165.58 square miles.
Major highways, including the Kansas Turnpike (I-35), Interstate 135 and U.S. 54 (Kellogg Avenue) link the City with a large trade area that encompasses a population of more than 1.1 million people within a 100-mile radius. The City of Wichita employs approximately 3,100 employees providing a full range of municipal services, including police and fire protection, parks and recreation programs, libraries, public housing, municipal transportation, airports, water and sewer utilities, general administration, and other services.
Information regarding the City of Wichita can be found at https://www.wichita.gov. The legislative body of the City consists of a six-member City Council, elected by district, and a full-time Mayor elected from the City-at-large. The Council members and the Mayor serve four-year terms overlapping. The Council and Mayor establish general policies, which are executed by the City Manager.
The City of Wichita is soliciting request for bids from vendors and/or firms for 39,000 GVWR Dump Trucks for the Fleet Division. The City reserves the right to award all, some, or none of the goods/services set forth in this Request for Bid (RFB) to any one proposer based on the City’s review and assessment of the bids meeting the criteria/specifications set forth herein.
II. SCOPE OF SERVICES
The Vehicle supplied to meet these specifications must be current standard production, new, and unused, substantiated by current published literature and price sheets.
The manufacturer must be prepared to prove satisfactory experience in the design and manufacture of the type of vehicle described herein. Service facilities are to be staffed by qualified employees with an adequate inventory of parts for repair and service of the unit must be located in the Wichita, Kansas area.
The unit bid must meet or exceed industry or SAE standards. Standards used by societies that are not members of the American National Standards Institute will not be accepted.
The Following Vehicles are Indicative of the Type Sought in this Bid Invitation:
Freightliner International Kenworth
Other vehicles by other manufacturers that meet the criterion of this specification are also eligible, but at the City’s discretion, other units must be demonstrated and approved by the City prior to award.
Bidders must return the following form below completed for every space requested in, Section II - Bidder’s Proposal column. Bidders shall indicate that the item being bid is exactly as requested or provide a description to indicate any deviation from the specifications of the item being bid meets or exceeds item specifications.
https://www.wichita.gov/
City of Wichita 5 RFB #260068
Meets/Not Meets Response Matrix Section I
City Specifications (Minimum) Section II
Bidder’s Proposal
Specification Meets Not Meets Comments (required if deviation listed)
ENGINE:
Type: L9 Cummins Diesel (Wet Sleeve Only) Horsepower: 330 gross at 2,000 RPM Maximum Engine output: 1,000 lb./ft Torque at 1,400 RPM Maximum Air filtering system: heavy-duty (dry type) with an air filter restriction gauge mounted so it is visible by the operator and a dash-mounted DPF switch Cooling system: heavy-duty, increased capacity with permanent anti-freeze installed and tested to protect to 20 degrees below 0 Fahrenheit. Dex-Cool silicate free extended life coolant (Unless a wet sleeved engine is suppled, documentation warranting the engine against cavitation (pitting in the cooling system) for 7-years or 150,000 mile will be required).
HOUR METER:
Dash-mounted hour meter that records engine operating time.
EXHAUST SYSTEM:
Horizontal muffler with a vertical stack. A heat shield and a turnout shall be included. All components shall be aluminized steel or other corrosion-resistant materials.
TRANSMISSION:
Minimum heavy-duty 5-speed automatic, Allison 3000 RDS with fluid temp gauge mounted in the cab connect to the outlet port of the transmission. The controls shall be dash mounted. The transmission shall be equipped with synthetic fluid.
FRONT AXLE:
Heavy-duty with carrying capacity of not less than 16,000 lbs., SFA
REAR AXLE:
Heavy-duty single speed Hendricks, 23,000 lbs. capacity with axle ratio capable of maintaining normal highway speed (65 mph) fully loaded at a 3% grade.
SPRINGS:
16,000 lbs. front with shocks, 23,000 lbs. rear with 4,500 lbs. auxiliary.
STEERING:
Full power or power assist.
City of Wichita 6 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
ELECTRICAL SYSTEM:
Heavy-duty with 160 amp minimum, high output alternator and two (2) batteries capable of producing 1900 minimum CCA at zero (0) degrees Fahrenheit.
SERVICE BRAKE:
Heavy-duty, air-operated disc type, complete with ABS, gauge, warning light, and buzzer mounted on instrument panel. Meritor WABCO 1200 Series or approved equal, heated air dryer and heated automatic tank drain valves. A quick connection (Milton Model #815 Style L) shall be provided with easy access to allow for charging of the air tanks of downed trucks to release brakes for towing.
PARKING BRAKE:
Air: MGM spring type.
FRAME:
The frame shall have a rating of no less than 2,000,000 RBMs and shall be equipped with 24-inch frame extensions and any necessary hardware required to install a front crankshaft driven hydraulic pump.
WHEEL BASE:
Wheelbase 177-inches, cab to axle 102-inches minimum. This is an approximate measurement. The chassis supplier shall work with the equipment installer to ensure proper fit and finish
WHEELS:
Six (6) aluminum rims to match six (6) 315/80r22, (wheels to be rated to match the GVWR on which they will be installed.
TIRES:
Front: Two (2) 315/80r 22.5 18 ply conventional tread radial tires.
Four (4) 315/80r 22.5, load range L M/S tread rear
(The tires must meet the GVWR and speed rating of the vehicle and shall in no way reduce its carrying capacity)
ACCESSORIES:
Directional signals, front and rear equipped with traffic hazard switch.
Safety glass to be installed in all cab openings, tinted for doors and windshield.
Phillips fender mounted convex mirrors or approved equal on both fenders of the truck
City of Wichita 7 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
ACCESSORIES CONTINUED:
Seats, air ride driver & passenger. Bostrom 910 or approved equal.
Heavy duty fresh air heater, defroster and air conditioning.
Dual electric, 2-speed windshield wiper with intermittent feature.
Heated dual west coast type rear view mirrors 15” x 6” minimum.
Backup warning system, electrical type. Min 97 DBA.
Exterior grab handles one (1) on driver’s side and one on exhaust stack.
Pins for tailgate and plow shall be welded to truck using chain to prevent theft.
Air operated tailgate
Five (5) pound fire extinguisher mounted inside the cab.
Oil pressure, fuel level, water temperature and ampere gauges shall be mounted on instrument panel (lights in lieu of instruments not acceptable). Alarm to sound if low oil pressure or excessive coolant temperature occurs.
45-gallon aluminum fuel tank (minimum)
Aluminum air tanks
Air horn
Front tow hooks and rear d-rings
AM/FM stereo
City of Wichita 8 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
ACCESSORIES CONTINUED:
Heated windshield and mirrors, aftermarket acceptable
Wiring for two way radio hook up
Electric trailer brake controller with six (6) prong plug
Electric trailer plug for air brake trailers
CAB and BODY:
Shall be equipped with a stationary grille, full forward tilt hood, and running boards
EXTERIOR PAINT:
White factory standard with clear cost or approved equal. The top of the hood shall be painted to match Ditzler stock # DQE 9000 with flattener
WIRING:
All wire splices shall be soldered with plastic or resin-type solder (acid not approved) and sealed with dual-wall heat-shrinkable tubing with an inner wall that melts into voids of wire or mechanical connections.
KEYS:
Each unit supplied under this bid shall be delivered with a minimum of four (4) copies of each key required for the vehicle.
LOW VOLTAGE PROTECTION:
The unit shall be equipped with a low voltage protection system that will automatically turn off accessories in the event of low voltage. An aftermarket unit will be acceptable if it has an automatic function that disconnects the batterie and prevents the batteries from becoming discharged automatically. Manual battery disconnects are not acceptable.
AIRLINES AND VALVES:
The unit shall have all valves, airlines, and fittings required to tow a trailer equipped with air brakes.
The airline glad hands shall be mounted in a way to protect them from debris that may damage them while dumping the contents of the bed. (LOCATION TO BE VERIFIED PRIOR TO INSTALLATION WITH MIKE NORDICK AT 316-268-4040 or EMAIL MNORDICK @WICHITA.GOV.)
City of Wichita 9 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
TOOL BOXES:
One (1) aluminum toolboxes 24-inch x 18-inch x 18-inch in size, installed below the bed on each side of the frame rails in front of the rear wheels. Two (2) total toolboxes.
TRAILER LIGHT WIRING:
The trailer light wiring to be Pollak Model 11-720 7 PIN heavy duty plug with a Pollack 11-761 protective wiring boot and a 11-607, 6 Pin heavy-duty socket or approved equal at the rear of the vehicle
TRAILER HITCH:
The trailer hitch shall be connected to the frame rails in such a way as not to reduce the capacity of the frame rails in any way. The coupler shall be a pintle-style coupler with a trailer weight rating no less than 90,000 lbs. There shall be two d-rings mounted beside the coupler for trailer safety chains, which shall meet DOT regulations regarding safety break away chains.
OPTIONS:
Option 1: Chalmers rear suspension system (NO LEAF SPRING TYPE SUSPENSION ALLOWED)
Option 2: : Haul Max rear suspension system (NO LEAF SPRING TYPE SUSPENSION
Option 3: Wing panel type dash.
Option 4: Trade of City owned equipment. The bidder shall indicate the trade-in value for each individual item listed. It is the vendor’s responsibility to fully inspect and evaluate the units. The City of Wichita will make every effort to ensure that the units are in the same general condition as when they are inspected but the units will continue to be used in daily operations until their replacements are delivered. Normal wear and tear will occur and will not be addressed. To inspect contract Mike Frazier at 316-305-3394 City ID # 001663; 2008 International Work Star; Serial # 1HTWDAAR78J691473; 54,895 miles City ID # 001674, 2008 International Work Star, Serial # 1HTWDAAR08J691461, 83,125 miles City ID # 001675, 2008 International 7400, Serial # 1HTWDAAR18J691467, 106,751 miles City ID # 001694, 2008 International 7400, Serial # 1HTWDAAR88J691465, 107,467 miles City ID # 001718, 2008 International 7400, Serial # 1HTWDAAR28J691462, 69,996 miles City ID # 001777, 2008 International Work Star, Serial # 1HTWDAAR08J1047314, 87,801 miles
Option 5: Force America Hydraulic System in lieu of the specified power hydraulic system.
City of Wichita 10 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
OPTIONS CONTINUED:
Option 6: Live gear transmission mounted type PTO pump system in lieu of the specified engine crankshaft driven variable displacement system.
Note: Plows and spreaders attached to the trade0in trucks are not included in the trade-in.
SPECIAL NOTES:
Advertising:
No dealer emblems, decals, or placards are to be on the vehicle.
Deletion:
No factory-installed standard equipment or optional package(s) to be deleted. All options and/or option packages that are factory standard on the model bid must be provided on the vehicle bid Mileage:
Odometer reading at F.O.B. destination must not exceed 50 miles.
WARRANTY SERVICE:
The successful bidder must furnish proof that they will and are capable of providing parts, service, and repair to all items herein specified. The vendor must list contact information and location of the facility providing the warranty work, both body and chassis. The location of the facility providing warranty work must be within 30 miles of the City of Wichita city limits. Bidder shall furnish in writing manufacturer’s standard warranty terms and conditions, which they agree to administer.
MANUALS:
The successful bidder shall deliver to the fleet maintenance supervisor for units furnished under this bid, two sets of the following:
Current edition of the operator’s manual Current edition of the service/maintenance repair manual Current edition of the electrical diagrams Current edition of the emissions diagnoses manual (Where possible, it is preferred that manuals be electronic versions)
OPERATOR TRAINING:
The vendor shall provide a minimum of four (4) hours of on-site interactive “operator training” for City staff. The training shall include all points covered in the operator’s manual. If needed, the vendor shall provide the necessary tools and teaching aids to conduct the on-site training. At the completion of the training, each participant shall understand how the equipment operates and what is necessary to maintain the equipment to the manufacturer’s specifications.
City of Wichita 11 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
MAINTENANCE TRAINING:
The vendor shall provide at no additional cost to the City a minimum of four (4) hours on-site interactive “operation and maintenance” training to fleet division personnel. Training to take place no later than 90 days from delivery of vehicle/equipment. If needed, the vendor shall provide the necessary tools and teaching aids to conduct the on-site training. At the completion of the training, each participant shall understand how the equipment operates and what is necessary to maintain the equipment to the manufacturer’s specifications. At the completion of the training, each participant shall be awarded a certification of completion.
CORRECTION OF DEFICIENCIES:
Should it be determined that upon delivery, the vehicle(s) fail to meet these bid specifications in any respect, the bidder shall, at no expense to the City, correct such deficiencies without delay.
F.O.B. DESTINATION:
The successful bidder shall deliver each item F.O.B. destination to the City of Wichita, 1801 South McLean Blvd., Wichita, KS.
The successful bidder must order the truck chassis within ten (10) days after receiving the purchase order. The successful bidder must provide the City of Wichita purchasing division and fleet maintenance division with a signed and dated order receipt showing that the chassis has been ordered withing the 10-day time period. The successful bidder must provide the body builder with the chassis with 120 days after being ordered. The body builder will have 150 days to complete the installation of the dump body as outlined withing the specifications. The truck shall be delivered to the City of Wichita completed and ready to go in less than 270 days. Liquidated damages of $100.00 per calendar day shall be deducted from the total of the invoice payment to the successful bidder for each day in excess of the required 270 day delivery time frame.
City of Wichita 12 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
SUPPLEMENT A:
New Current twelve (12) cubic yard dump bed to be installed complete General: Bed, hoist, and sub-frames must be new standard production models of the latest design in current production
BED:
Eleven (11) foot crossmember less type dump body with 12 cubic yard capacity. Inside length to be 132-inches, inside width 96-inches minimum to accommodate spreader. Minimum height tailgate to be 52-inches head sheet height to be 52 inches. Bed sides to be 44-inches. Overall dump height 94-inches maximum. Dump body shall be 100% completely welded (no skip welding shall be allowed).
Body must be of dirt-shedding design. Cab to axle shall be 96-inches.
SIDES:
The side walls shall be constructed of ¼ AR400 steel (one piece design from top to bottom, no seams).
At a minimum the sides shall be braced with a top rail, lower rail. The top rail shall be dirt-shedding design, approximately 8.75-inches in height and 4-inches in depth. The top side of the top rail shall be sloped approximately 52 degrees, and the bottom side sloped approximately 55 degrees. The lower rub rail shall be of dirt-shedding design with the top side sloped approximately 56 degrees. The vertical face shall be 3 3/8-inches wide. The lower edge of the rub rail shall extend back approximately 10.75-inches to mate with the dump body floor. The front bolsters shall be constructed of 10-gauge grade 50 steel and extend between the lower rub rail and top rail. The front bolster shall be 9 inches in depth, dirt-shedding design with 60-degree slope on the forward face. The rear bolsters shall be 4 ¾ inches x 12 inches full depth constructed of ¼ inch grade 50 steel. The top portion of the bolster shall be tapered for the flush upper tailgate hardware. The rear bolsters shall have upper and lower chain attachments. They shall be 5/16-inch formed channel with slot for 3/8-inch chain. Attachments shall be 3 ¼ inches wide x 3 ¼ inches tall x 2 inches deep. Chain attachments shall be positioned to allow clearance for Whelen boxes.
FLOOR:
The body floor shall be one piece constructed of ¼ inch AR400 steel with an integral 5-inch radius floor.
Weld-in knee braces will not be accepted. The body long sills shall be constructed of 8-inch I-beam.
The body rear apron shall be a formed channel design. A ¼-inch overlay reinforcement shall tie the rear bolsters into the rear apron to give it structural integrity at the tailgate latch points and prevent flexing.
City of Wichita 13 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
TAILGATE:
The tailgate shall be constructed of ¼-inch AR400 sheet panel and include 10-gauge grade 50 perimeter bracing All bracing shall be dirt-shedding design. The braces shall measure approximately 6.75-inches in height. The tailgate perimeter bracing shall be formed channel design with the upper and lower horizontal braces sloped on their top edge to shed debris. The lower tailgate latching pins shall be integral to the tailgate. The pins shall be 1 ¼-inches in diameter. The upper pivot ears shall be 1 inch thick and cut to accept 1 ¼-inches upper hinge pins. The tailgate shall be air operated. The tailgate latch fingers shall be ¾-inch flame cut. Cast fingers will not be accepted. The tailgate latching mechanism shall utilize stainless bushings to minimize maintenance. The tailgate shall have 4 formed chain attachments with slots for 3/8-inch chain welded to tailgate at upper and lower positions on inside of outer braces. Attachments shall be formed out of 5/16-inch steel with 3-inch legs and approximately 3 ¼ inches tall. The two upper tailgate pins must have 3/16-inch chains welded to pin and then to rear corner post. Chains shall be long enough for removal of pin. Two (2) 3/8 chains, 88-inches long, shall be supplied. The chains shall be running through a protective sheathing to keep them from chipping the body.
CAB SHIELD:
A weld-on cab shield shall be provided with the body. It shall measure approximately 40-inches in depth and 86-inches in width. The main panel shall be constructed of 10-gauge grade 50 steel with the endplates constructed from 7-gauge grade 50 steel. The top panel shall be tapered from front-to-rear. There shall be approximately 2.5-inches drop from front to rear over the 40-inch span to keep water and debris from settling. The cab shield shall be reinforced with 2-inches x 3-inches x ¼-inch rectangular tubing on the underside and down the front face to give it structural integrity. The steel tubing shall be cleaned and primed prior to installing them. The left and right front corners of the cab shield shall be angled at approximately 45 degrees in order to accept an oval-type LED strobe light.
There shall be four (4) Whelen 5G-7 oval type strobe lights mounted on the front of the cab shield, one on each 45-degree front end and two spaced evenly on the front. The wiring for the strobe lights shall run through steel conduit under the cab shield, down the front side of the bed, and under the bed to the back of the chassis frame, then back to the cab and wired to a switch in the cab.
FRONT HEAD and DOGHOUSE:
The head sheet shall be fabricated out of ¼-inch AR400 steel. The top of the sheet shall be welded to a 10-gauge formed C-Channel, full width and fully welded. The doghouse shall be constructed of ¼-inch AR400 steel.
City of Wichita 14 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
FRONT HEAD and DOGHOUSE CONTINUED:
The doghouse shall be 12-inches wide and 12-inches deep. The doghouse shall not protrude any more than 13-inches into the bed area for spreader clearance.
HOIST:
The dump body hoist shall be inverted Trunnion mounted hoist with internal doghouse. Hoist cylinder shall be single-acting with 140 inches of stroke. Must meet class 60 specifications for NTEA hoist classification. Cylinder must be of a bore seal design and be equipped with nitride cylinder tubes.
Cylinder must be equipped with greaseless composite brushings on both upper and lower pins. Hoist shall have a one-piece modular cradle that incorporates the body props, body guides, and blocks for the hoist composite bushings. Cylinder must be installed straight up and down to relieve the stress on the cylinder tubes and on the packing. Cylinder shall have a 2-year warranty.
HINGE:
Rear hinge shall be constructed out of a 6 inches x 8 inches x ½-inch formed angle with hinge ears constructed out of 5 inches x 8 inches x ¼-inch steel. The angle shall be cut below the hinge block area to provide an escape path for debris that might enter the area. The hinge blocks shall be 2.5 inches wide and 7 inches long at the body mounting surface. Hinge blocks shall have greaseless composite bushings. Hinge pins shall be 2-inch stainless steel with a teardrop outer plate that is bolted to hinge ear with a 5/8-inch grade 8 bolt.
LADDERS:
One (1) fold-down ladders shall be installed, on the rear of the driver’s side. The lower portion of the ladder shall fold against the upper portion when stored and shall be held in place by a rubber ball and socket-style latch. The ladder shall hinge at the bottom of the bedside and shall be designed to lock into place when down. The ladder uprights shall be constructed of 1 ½-inches x 3/8-inch steel and shall have rubber end caps at the top of the ladder. The ladder rungs shall be 16-inches wide and constructed of 1 ½-inches wide rung material with button-style traction tread and evenly spaced. The ladders are to be painted to match the dump body.
WALK RAILS:
A 1 ½ inches x ¼-inch walk rail shall be installed on each side just above the lower rub rails of the dump body. The rails shall run full length between the front and rear bolsters, with the curbside stopping approximately 12-inches in front of the rear bolster, allowing room for the spreader quick couplers.
City of Wichita 15 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
CENTRAL HYDRAULIC SYSTEM;
The truck shall be equipped with a complete central hydraulic system that will supply a maximum working pressure of 2500psi. This system shall be used to operate the dump body hoist, hydraulic powered material spreader, and a hydraulically operated snow plow with power up and down functions with a pressure sensing switch. The system shall have electrically actuated valves for the hoist & plow functions and closed loop automatic ground speed oriented valves for the spreader functions. The system shall consist of an engine crankshaft driven variable displacement piston pump, hydraulic oil supply reservoir hydraulic filter, and directional control valve system.
HYDRAULIC PUMP:
The variable displacement piston pump (load sensing type) must be cap able of 48gpm & 3000psi at 2500rpm. The pump shall be a Sauer-Danfoss model JRL075 or approved equal. The pump shall be crankshaft driven using Spicer 1280/1300 driveline components. The pump must have an internal bleed down compensator. The case drain must be positioned as high as possible and be directed back to the reservoir without passing through the return line filter. The pump shall have a 1-1 4" keyed shaft drilled & tapped. A 1-inch split flanged pressure port & a 2-inch split flanged suction port. the pump must have a pressure gauge port integral to the rear cover of the pump. A 1-inch high pressure electric solenoid shall be connected to the output line as close to the pump as possible to allow shutting down the hydraulic system in the event of a catastrophic failure.
HYDRAULIC RESERVOIR/VALVE ENCLOSURE:
the hydraulic valve shall be mounted ln a weather tight enclosure. Enclosure shall be three (3) pieces.
The enclosure body/tank, valve mounting plate & the lid. Reservoir shall be a minimum of 30-gallon capacity. Reservoir shall have a screened filler neck with breather cap installed on a 1-inch riser.
Reservoir shall have a sight/ temp gauge with guard. An in-tank style filter & head assembly, a ¾-inch magnetic drain plug & a 2-inch suction strainer. A 2-inch full flow brass ball valve shall be installed on the strainer. The reservoir shall come with a low oil sending unit, a temp sensor and a pressure switch for the filter condition. The valve shall be bulkhead fitting mounted to valve plate with ports coming out the bottom. Outside lip of enclosure shall have a gasket all the way around to seal from weather when lid is installed. Lid shall be held on with two spring tension latches on each side & it shall have two (2) lifting handles. The tank & valve enclosure shall be of one unit; separate units will not be accepted.
City of Wichita 16 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
HYDRAULIC STACK VALVE:
Hydraulic valve must be capable of a nominal 35gpm & the valve must be pressure compensated, load sensing type with individual flow control compensators on each section. All sections shall have LED indicators on each solenoid. Valve to be arranged as follows:
Single acting cylinder spool for hoist 0-39gpm, proportional 12VDC operated, with spring return to neutral section shall have manual handle overrides with stroke limiters.
Single acting cylinder spool for plow lit, proportional 12VDC operated with spring return to neutral.
pressure compensated 0-15gpm main spool. section shall have manual handle overrides & stroke limiters.
Double acting cylinder spool for plow angle, proportional 12VDC operated with spring return to neutral.
pressure compensated 0-15gpm main spool. section shall have manual overrides and stroke limiters.
Single acting 0-15gpm spool for auger, proportional 12VDC spring to center with manual override.
Single acting 0-7gpm spool for spinner, proportional 12VDC spring to center with manual override.
auger & spinner sections shall be a part of a manifold assembly that has a pressure reducing valve and solenoid drain. Manifold has the ability to add pre-wet & or anti-ice applications.
SPREADER CONTROL PANEL:
Pedestal mounted style freedom MDC two joystick controller with six function switches. one joystick for plow up/down and left/right functions, and one for bed hoist up/down functions. both joysticks shall be capable of variable speed control, (feathering control) meaning the plow shall raise/lower and move left/right at variable speeds depending on the position of the joy stick. The bed hoist joystick shall have the same features. the switches shall operate plow lights, PTO, pre-wet, truck strobe lights, spreader strobe lights, spreader spot light, (switches shall be confirmed prior to build). the spreader and pre-wet operation shall be controlled by a freedom 2.2 touch screen controller mounted to the freedom MDC joystick controller. Pedestal shall be cap able of swinging out of the way and locked in place when necessary.
City of Wichita 17 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
PLUMBING:
Hydraulic hose minimum dimensions as follows:
1. Hi-Pressure 1-inch diameter from pump to valve
2. Hi-Pressure ¾-inch hoist cylinder hose
3. Hi-Pressure 3/8-inch plow hoses & load sense hose
4. Hi-Pressure ½-inch spinner hose
5. Hi-Pressure 5/8-inch auger hose
6. Medium pressure ½-inch case drain hose
7. Medium pressure ¾-inch spreader return hose
8. Medium pressure 1-inch main return hose
9. Low pressure 2-inch suction hose
Note: The spreader hoses shall pass through connectors mounted in the right rear rub rail of the dump body. All hoses shall be secured with rubber hose clamps and ties as needed. All hoses shall be protected if ran through or next to any sharp areas. Flat faced connections shall be used as much as possible
ACCESSORIES:
Roll-up electrically opera ted tarp, Rollrite brand or approved equal, with a steel, tarp roller protector, 18 oz. vinyl mesh tarp fabric, and shall have aluminum tarp arms with a minimum four spring system that will lift the tarp over heaped loads. The units shall be equipped with an aluminum tension bow to help prevent billowing. The tarp assembly shall be mounted on the back of and just below the top of the cab shield, and be supported by mounting brackets on the ends and one in the center. location of brackets and cab shield shall be confirmed prior to mounting. The tarp assembly arms shall be l shaped as much as possible so that they are not protruding past the front of the bed area when in the rolled up position. The control for the tarp shall be a momentary switch factory mounted in the dash and clearly marked tarp retract/cover. The dual 6ga cable shall be ran through EMT conduit in the following areas, on the underside of the cab shield, down the front face, & on underside of dump body. Any exposed wiring shall be encased in automotive split loom. Mud flaps behind the rear wheels and in front of the intermediate axle. All aftermarket hoses and wiring shall be running along the top center of the frame and secured with clamps to a minimum of a¼ in. by 2 in. metal strap. All hydraulic hoses shall run in conjunction with tank side and wiring will be on opposite side. Aftermarket hoses and wiring will not be running in a single bundle and running. Aftermarket hoses and wiring through the frame rail shall be avoided whenever possible.
City of Wichita 18 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
WIRING AND SAFETY CONSTRAINTS:
The indicators are as follows:
Low hydraulic oil light, Hydraulic oil temperature light, Hydraulic oil filter condition light, body-up light, and low liquid light.
The wiring for the warning light system shall be wired to a battery feed source and protected by a circuit breaker of the appropriate rating. All wiring that passes through any metal bulkhead shall use a pass-through connector or be protected by a grommet.
The low hydraulic oil, hydraulic oil temperature, bed up indicator and filter restriction sensors shall have some type of weather pack end to add in replacement of sensor.
All electrical components such as the tarp relay, vibrator solenoid, air tailgate solenoid, and all other electrical components shall be mounted in the valve enclosure on the back wall. All of the wiring for the low oil, oil temp, filter condition, & body raise shall also be taken into the valve enclosure. All wiring, solenoid's valves etc. shall be clearly labeled. The 12 volt cables that go to the tarp motor & to the vibrator shall be grommet protected. All wiring that exits the valve enclosure shall be through sealed cables. A 75amp ignition relay shall also be installed in the enclosure. All electrical components requiring 12 volt shall come from the ignition relay. Ignition must be in the on position for any of the components to operate.
A pre-wet harness shall be installed and wired complete. T0he spreader work light circuit & spreader strobe light circuit shall be included in the harness. The harness shall be sealed, no exposed wiring will be allowed except where it plugs into the chassis module.
A six prong water proof military plug-in shall be recessed into the front side of the rear corner post above the quick couplers. The spreader work light, spreader strobe lights, pre-wet low liquid, pre-wet ground and accessory ground shall be wired into the plug-in thru a sealed wiring harness. The harness shall be wired into the OEM supplied wiring. The military plugin shall come with a sealed plug with chain, connector, & wiring must match up to existing city of Wichita pre-wet systems.
City of Wichita 19 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
SAFETY CONSTRAINTS:
If the hydraulic oil falls below approximately 50% of capacity, the indicator light which will be marked low hydraulic oil, will illuminate. An audible alarm will sound, and the pump will shut down.
If the hydraulic oil temperature exceeds 170 degrees, the indicator light which will be marked hydraulic oil temperature will illuminate, an audible alarm will sound, and the pump will shut down.
If the filter becomes restricted beyond an acceptable level, an indicator light will illuminate.
A bed-up switch shall be installed at the rear of the bed and there shall be an indicator light marked (Bed-Up) that will illuminate.
If the pre-wet tanks get too low, there shall be a light that will be marked (low liquid) that will illuminate.
There shall be an over-ride switch which will allow the operator to override the pump switch to momentarily operate the unit (lower bed) so as to get it back to the shop.
The wiring for the bed lift solenoid shall be configured in such a way that it will not function if the unit is moving faster than 10-mph.
WARNING LIGHT SYSTEM:
A DOT3405D Whelen light system shall be furnished & to include: 400 series LED Stop/Turn/Tail, LED back-up & strobe lights shall be installed in stainless steel light boxes recessed into the rear corner posts of the dump body.
Two PN: 2EAOOZCR 4" Whelen strobes shall be installed as low as possible in the front corner posts of the dump body.
All wiring and wiring connections exposed to the weather shall be in waterproof connectors and/or convoluted tubing. All lighting components shall carry a 5-year manufacturers warranty. THERE WILL
BE NO EXCEPTIONS.
City of Wichita 20 RFB #260068
Section I City Specifications (Minimum)
Section II Bidder’s Proposal
Specification Meets Not Meets
Comments (required if deviation listed)
PLOW LIGHTS:
Plow lights shall be mounted on the fender section of the hood using appropriate pedestal mounting so light housing is a minimum of 75" from the ground. Plow lights shall be mounted in a way that they tilt forward with hood of vehicle without unplugging. The wiring harness. (mounting brackets shall be stainless steel).
Plow lights shall be Truck-Lite Model DRL snow plow/ATL lights part number 80900 or approved equal.
Can be purchased at www.truck-lite.com
There shall be a two position, rocker switch mounted in dash which shall be marked plow lights. When the plow light switch is activated the factory headlights will become disabled and the factory installed dimmer switch shall control the low/high beam functions of the plow lights.
All wiring for the plow lights including marker lights, turn signals & headlights shall be ran to the driver’s side of the front bumper ending with a sealed connector. the add-on plow light harness shall plug into the factory connector.
PLOW FRAME:
Plow frame shall be Flink brand, model number PF 91-QL2 or approved equal, and shall be mounted on truck in accordance with Flink specifications to include special heavy duty bumper made with channel iron 12 x 30.9. Samples can be seen at 1801 S. Mclean Blvd. Wichita KS.
All pins on the plow shall have a 3/16 -inch chain welded to it. The chains will be long enough so pins can be removed. the chains shall be welded to the plow frame.
PAINTING:
After dump body is factory assembled it must be completely sandblasted. Dump body shall be cleaned with Neutra Care 5175 or approved equal & completely rinsed. Dump body must then have a phosphate solution applied & rinsed again. Unit must then be placed in dry oven for 30 minutes @200 degrees. Unit must be primed complete with a Tritech High Solids Gray (PN: 924-201) or approved equal. Underside of dump body must be painted black. Atter all accessories such as ladders, cab shield, light boxes, etc. have been welded on, the entire unit must be sanded. All welded areas must be feathered out & sealed. dump body must be painted with acrylic urethane with hardeners. body shall be painted a medium grey.
http://www.truck-lite.com/
City of Wichita 21 RFB #260049
III. BID TERMS
A. Questions and Contact Information:
Any questions regarding this document must be submitted via email to Tracy Jordan, tjordan@wichita.gov in accordance with the dates and times stipulated for questions. Any questions of a substantive nature will be addressed in written form as a posted addendum on the City’s Procurement Portal (https://wichita.gov/procurementportal). Respondents are responsible for checking the City’s Procurement Portal and acknowledging any addenda electronically as a part of the Procurement Portal submission’s electronic acknowledgment for all stipulated response forms and addendum acknowledgments.
To ensure interested parties receive notification of any published addendum by the City, respondents need to verify the selection of “Real Time” on their Procurement Portal - Notification Center settings:
• Accept Invites from Agencies (to receive invitations for new solicitation opportunities)
• Accept Messages (to receive notifications for any published addendum)
Failure to select “Real Time” notification settings will impact your Procurement Portal profile’s ability to receive notifications and messages by the City of Wichita Purchasing Division.
To view your Procurement Portal’s Notification Center settings, log into your account and select Settings, Global Vendor Record, Manage my Organization, and Notifications to view this settings screen. If further assistance is needed, please contact the Purchasing Office directly at purchasing@wichita.gov or by phone at (316) 268-4636
B. Bid Submission:
Sealed Request for Bid will be received in the office of the City Purchasing Manager, 12th Floor, City Hall, 455 North Main, Wichita, Kansas, prior to 10:00 O'CLOCK A.M., FRIDAY, APRIL 17, 2026, Bids are to be submitted through the City’s Procurement Portal (https://wichita.gov/procurementportal) using a secure login/password.
If a Bonfire registration for system access has not been completed, please visit https://www.wichita.gov/purchasing for assistance. On the Purchasing website page, a video tutorial (Bonfire Registration Video) walkthrough and registration resources are available to help in the completion of the registration process. If further assistance is needed, please contact the Purchasing Office directly at purchasing@wichita.gov or by phone at (316) 268-4636.
All bids, including supporting documentation/manuals, shall become the property of the City
C. Evaluation Criteria:
Bid Award will be based on Lowest and Best Total Net Bid with Options as Selected from a Responsible and Responsive vendor.
The City, through its Board of Bids and Contracts, reserves the right to accept or reject any or all bids and any part or parts of any bid and to waive formalities therein to determine which is lowest and best bid. Any bid which is incomplete, conditional, obscure, or which contains additions not called for or irregularities of any kind, may be cause for rejection of the bid. All bids are awarded subject to a check of the computations shown on the "Request For Formal Bid" form. In the event of a discrepancy in the extension(s) or total for the item(s), the unit cost shall prevail.
mailto:tjordan@wichita.gov mailto:purchasing@wichita.gov https://wichita.bonfirehub.com/ https://www.wichita.gov/purchasing mailto:purchasing@wichita.gov
City of Wichita 22 RFB #260068
The City, through its Purchasing Manager, reserves the right to accept or reject any or all submittals and any part or parts of any submittal, and to waive formalities therein to determine which is the most beneficial bid.
D. Tentative Schedule:
The tentative schedule will apply to this Request for Bid (RFB) and may change according to with the City’s needs or unforeseen circumstances. All dates and times will be in Central Standard Time (CST;
CDT) and can be confirmed through the Purchasing Office located at 455 N. Main 12th Floor Wichita, KS 67202, calling (316) 268-4636, or by contacting the buyer listed on the solicitation document.
Questions of a substantive nature will be reviewed and answered in written form as an addendum and posted to the City’s Bonfire portal at https://wichita.gov/procurementportal.
Vendors are encouraged to complete bidder registration by visiting the City of Wichita’s eProcurement Portal at https://wichita.gov/procurementportal, then follow the link to the Bonfire vendor registration page to register your company. Please check our website, https://www.wichita.gov/purchasing for upcoming registration opportunities, training dates & locations, and information as it is updated in the near future.
E. Minimum Respondent Qualifications:
This section lists the criteria to be considered in evaluating the responsiveness of firms interested in providing the goods and/or service(s) specified in this Request for Bid. Firms should meet or exceed these qualifications to be considered for award. Any exceptions to the requirements listed should be clearly detailed in the proposer’s response. Bidders shall:
1. Understanding of industry standards and best practices.
2. Have experience in providing goods and/or services of comparable size and complexity to that being requested.
3. Have knowledge of and comply with all currently applicable, and as they become enacted during the contract term, federal, state and local laws, statutes, ordinances, rules and regulations. All laws of the State of Kansas, whether substantive or procedural, shall apply to the contract, and all statutory, charter, and ordinance provisions that are applicable to public contracts in the city shall be followed with respect to the contract.
4. Registration with the Kanas Secretary of State’s Office before contract execution.
5. Having Municipal government experience is preferable; however, the City will make the final determination based on responses received and the evaluation process.
6. Have the capacity to acquire all bonds, escrows or insurances as outlined in the terms of this
RFB.
7. Provide project supervision (as required) and quality control procedures.
8. Have appropriate material, equipment and labor to perform specified services.
9. Ensure parking occurs only in designated areas and parking permits are displayed (if provided).
10. Wear company uniform or ID badge for identification purposes.
Tentative Schedule of Events Solicitation Advertised March 24, 2026 Questions Due Via Email April 10, 2026, 3:00 p.m.
Questions Answered Via Addendum Week of April 13, 2026 Bids Due April 17, 2026, 10:00 a.m.
City Council (tentative) April 28, 2026 https://wichita.bonfirehub.com/ https://wichita.gov/procurementportal https://www.wichita.gov/purchasing
City of Wichita 23 RFB #260068
11. Meet local, state, and federal guidelines as applicable.
F. Bid Requirements:
1. Completed Bonfire Portal (https://wichita.gov/procurementportal) submission (or Request for Bid
Form signed and dated if submitted via paper).
2. Bids submitted may not be withdrawn for a period of 60 days following the opening of this Request for Bid. Prices MUST also be free of duties, federal, state, and local taxes unless otherwise imposed by a governmental body, and applicable to the material on the proposal.
3. Pricing for all stipulated Item(s) and/or Group(s) requirements. Bidders who do not submit pricing for all items when stipulated may be deemed nonresponsive when not adhering to:
a. Lowest and Best Total Net Bid with Options as Selected when requested will be calculated by aggregate total. No other pricing or miscellaneous charges will be submitted.
4. Timeline of substantial (habitable; usable as intended), and final completion (all work 100% completed; no additional work).
5. Exceptions to any part of this document clearly delineated and detailed.
6. Responses that do not include all required forms/items may be deemed non-responsive.
G. City of Wichita Responsibilities
1. Designate a department contact person for any daily communication(s) required to ensure goods and/or services delivery.
2. Provide Contractor with appropriate facility access for completion of awarded goods and/or services.
3. Provide Contractor with Contact Information for key City staff who will manage the contract.
H. Challenges and Protests
Challenges A challenge is defined as a written objection by any party interested in responding to either a bid or proposal (collectively referred to as solicitations), when that party wishes to have the City consider an addition, substitution or modification to the specifications stated in the outstanding solicitation.
The written challenge of the solicitation specifications must be filed with the Purchasing Manager located on the 12th Floor, Finance Department at City Hall, 455 N Main, Wichita, KS 67202, telephone number
(316) 268-4636, at least five (5) business days before the solicitation opening due date and time as listed on the solicitation documents. Any challenge to solicitation specifications received after the five (5) business days deadline will not be considered by the City. The Purchasing Manager will acknowledge receipt of the challenge.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .