1 24002 BRCC TEDC Rf CD.pdf

PDF 641 KB Posted

Attached to
Technology Education and Development Center Roof Replacement
Solicitation number
80-80-BRCC202420
Issued by
Hyde County, North Carolina

About this file

The document is a set of architectural drawings for a roof replacement project at Blue Ridge Community College (BRCC) Technical Education Development Center (TEDC) in North Carolina, prepared by Mark Lusk Architecture PLLC. The project involves a comprehensive roof replacement across multiple roof sections (Roofs A, B, C, E, G, H, I, J, and K), with detailed plans for south and north roof configurations. The drawings include specific technical details such as roof drain replacements, scupper installations, mechanical unit curb treatments, and various flashing and membrane specifications. The project includes five bid alternates: replacing the existing roof hatch rail system, removing the existing satellite system, providing metal coping, adding walkway/treads, and providing a performance and payment bond.

The project is designed to comply with the 2009 North Carolina Energy Conservation Code, with specific requirements for existing buildings constructed before 2012. The roof replacement will maintain the existing R-value of R-17.4 and follow guidelines for reroof and replacement that do not require full compliance with current slope requirements or secondary drainage systems. The technical specifications indicate a fully adhered single-ply membrane roofing system, with careful attention to existing infrastructure such as mechanical units, conduits, and structural elements. The drawings provide extensive details on how to handle various roof transitions, penetrations, and edge conditions, suggesting a thorough and methodical approach to the roof replacement that minimizes disruption to the existing building systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER

SHEET

ARCHITECTURAL

T101 COVER SHEET

BRCC TEDC ROOF REPLACEMENT

A201

A202

A301

A302

SOUTH ROOF PLAN

NORTH ROOF PLAN

DETAILS

DETAILS

LIST OF DRAWINGS

MARK LUSK ARCHITECTURE PLLC

128 WOODBURN DR

SWANNANOA, NC 28778

828.808.9757

MLARCHITECTURE@CHARTER.NET

C o p y r i g h t

A l l

R i g h t s

R e s e r v e d

R e p r o d u c t i o n c o p y i n g o r u s e o f t h i s d r a w i n g a n d d e s i g n s s h o w n t h e r e o n w i t h o u t w r i t t e n c o n s e n t o f

M a r k

L u s k

A r c h i t e c t u r e

P L L C i s p r o h i b i t e d a n d a n y i n f r i n g e m e n t i s s u b j e c t t o l e g a l a c t i o n

BRCC TEDC

ROOF

REPLACEMENT

CE

HCRADERET

GER T

IS IT

N OR T H C A R OL I

AN

KSULS.KRAM

S WA N N OA, NC

A N

52786

HCRA

KSUL

KRA

M

CL

LP

E, RUTCETI

CEHCRA

DERET

G E R

YN

AP

MO

C

LARUT

IS

IT

N OR T H C A R OL I

ANS WA N N OA, NC

A N

MARK LUSK ARCHITECTURE PLLC

128 WOODBURN DRIVE

SWANNANOA, NC 28778

828.808.9757

CONTACTS

OWNER REPRESENTATIVE

ARCHITECT

OWNER

MARSHALL MORRIS

CONSTRUCTION PROJECT COORDINATOR

BLUE RIDGE COMMUNITY COLLEGE

HENDERSON COUNTY, NC

BLUE RIDGE COMMUNITY COLLEGE

ALISON ROGNAS

22556 LANYARD STREET

BOCA RATON, FL 33428

954.531.3991

CADD

NORTH CAROLINA BUILDING CODE SUMMARY

1. PER N.C.G.S. 143-138(b15): BUILDINGS CONSTRUCTED BEFORE 2012 ARE EXCLUDED FROM THE CURRENT CODE AND ARE

SUBJECT TO THE 2009 NC ENERGY CONSERVATION CODE. R-VALUE MIN. SHALL BE R-15, FOR CLIMATE ZONE 4 (NON-MARINE)

EXISTING R-VALUE = R17.4

2. NC ENERGY CONSERVATION CODE C503.1 EXCEPTION 2.e: REROOF SHALL NOT BE LESS THAN THE CONDITIONS/DESIGN PRIOR

TO ROOF REPLACEMENT

3. 1511.1 EXCEPTIONS 1&2: REPLACEMENT SHALL NOT BE REQUIRED TO MEET THE SLOPE REQUIREMENT OF

" PER FOOT OR

PROVIDE SECONDARY DRAINS OR SCUPPERS

4. 1511.3.1.1 EXCEPTIONS 3: ROOF RECOVERING SHALL NOT BE PERMITTED OVER WATER SOAKED ROOFING OR OVER 2

ROOF APPLICATIONS

ABBREVIATIONS:

1. REPLACE= REMOVE EXISTING AND PROVIDE AS SHOWN AND SPECIFIED

2. RD= ROOF DRAIN

3. CMU= CONCRETE MASONRY UNITS

4. BOW= BOTTOM OF WALL

5. POLYISO= POLYISOCYANURATE

6. SPM= SINGLE PLY MEMBRANE

7. PSP= POURABLE SEALER POCKET

BID ALTERNATES

ALTERNATE NO. 1 - REPLACE EXISTING ROOF HATCH RAIL SYSTEM

ALTERNATE NO. 2 - REMOVE EXISTING SATELLITE SYSTEM

ALTERNATE NO. 3 - PROVIDE METAL COPING AS MANUFACTURED BY CENTRIA

ALTERNATE NO. 4 - PROVIDE WALKWAY/TREADS

ALTERNATE NO. 5 - PROVIDE PERFORMANCE & PAYMENT BOND

MARK LUSK ARCHITECTURE PLLC

128 WOODBURN DR

SWANNANOA, NC 28778

828.808.9757

MLARCHITECTURE@CHARTER.NET

C o p y r i g h t l

R i g h t s

R e s e r v e p r o d u c t i o n c o p y i n g o r u s e o f t h i s d r a w i n g a n d d e s i g n s s h o w n t h e r e o n w i t h o u t w r i t t e n c o n s e n t o f

M a r k

L u s k

A r c h i t e c t u r e

P L L C i s p r o h i b i t e d a n d a n y i n f r i n g e m e n t i s s u b j e c t t o l e g a l a c t i o n

BRCC TEDC

ROOF

REPLACEMENT

CE

HCRADERET

GER T

IS IT

N OR T H C A R OL I

AN

KSULS.KRAM

S WA N N OA, NC

A N

52786

HCRAKSUL

KRAM

CL

LP

E, RUTCETI

CEHCRA

DERET

G E R

YN

AP

MO

C

LARUT

IS

IT

N OR T H C A R OL I

ANS WA N N OA, NC

A N

SOUTH

ROOF PLAN

ROOF PLAN

SCALE: 1" = 10'-0"

PROJECT NORTH

R I D

G E

ROOF DECK

SLOPE

ROOF DECK

SLOPE

ROOF DECK

SLOPE

ROOF DECK

SLOPE

ROOF DECK

SLOPE

ROOF DECK

SLOPE

T A

P E

R E

D

S L O

P E

T A

P E

R E

D

S L O

P E

T A

P E

R E

D

S L O

P E

T A

P E

R E

D

S L O

P E

13" W

22" H

9" W

16" H

4/A301

5" W CURB

22" H

12" W

SEE 1/A301 INSET

7" H BOW

22" H BOW (TYP)

68" H

9" W

13" W

22" H

9" W

16" H

4/A301

5" W CURB

22" H

13" H

4/A301

5" W CURB

21" H

9" W

16" H

16" H

22" H

EXISTING CRICKET (TYP)

SCUPPER (TYP)

14" H

RD

OD

RD

OD

RD

RD

RD

OD

RD

OD

RD

RD

RD

PV

PV

PV

9" W

GENERAL NOTES

1. EXISTING WOOD NAILER SHALL REMAIN UNLESS DETERMINED TO BE DAMAGED BY ARCHITECT. REMOVAL AND REPLACEMENT SHALL BE PERFORMED AT UNIT PRICE.

2. VERIFY DIMENSIONS, QUANTITIES, SIZES, AND OTHER EXISTING CONDITIONS PRIOR TO DEMOLITION WORK. DISCREPANCIES BETWEEN DOCUMENTS AND EXISTING CONDITIONS SHALL BE REPORTED TO THE ARCHITECT.

3. SITE ACCESS, STAGING AND SCHEDULE SHALL BE COORDINATED WITH OWNER.

4. PROVIDE 18-8 OR 304 STAINLESS STEEL FASTENERS WHERE IN CONTACT WITH PRESSURE TREATED WOOD.

5. CONTRACTOR SHALL PERFORM ALL WORK IN COMPLIANCE WITH THE AHJ. COSTS FOR PERMITS SHALL BE INCLUDED IN WORK. PROVIDE INSPECTION DOCUMENTS TO THE OWNER.

6. BUILDING ELEMENTS ARE EXISTING.

ROOFING NOTES

1. EXISTING ROOFING COMPONENTS:

FULLY ADHERED SPM MEMBRANE

RIGID INSULATION

TAPERED INSULATION (3"-7"± @ RF C,D)

" FIBERGLASS BOARD

METAL ROOF DECK

2. DEMOLITION: REMOVE EXISTING ROOFING SYSTEM COMPONENTS INCLUDING TERMINATION

BARS & FLASHING. EXISTING SPM SHALL REMAIN.

3. PROVIDE FULLY ADHERED 60 MIL TPO MEMBRANE ROOFING SYSTEM, AND

" COVER BOARD

OVER EXISTING SPM ROOFING. ATTACH

" COVER BOARD THROUGH INTO EXISTING METAL

ROOF DECK. CUT OPEN EXISTING SPM.

LEGEND

PARAPET WALLS-

13" WIDE- 2/A301

9" WIDE- 1/A301

12" WIDE- 1/A301 SIM

BASE OF WALL FLASHING 3/A301

ROOF DRAIN

5/A301

OVERFLOW ROOF DRAIN

SCUPPER 6/A301

PLUMBING VENT 2/A302

MECHANICAL UNIT CURB 4/A302

CONDUIT CURB SIM

MECHANICAL SUPPORT CURB 6/A302

ROOF HATCH

3/A302

CONDUIT CURB

CONDUIT CURB

10" H BOW

24" H BOW (TYP)RD

RD

RD

ROOF B

AUDITORIUM LEVEL: ROOF A

ROOF CROOF D

FIRST STORY ROOF LEVEL

PARAPET

BOW

RD

OD

PV

22" H BOW (TYP)

12" W

SEE 1/A301 INSET

SWANNANOA, NC 28778

828.808.9757

MLARCHITECTURE@CHARTER.NET

C o p y r i g h t l

R i g h t s

R e s e r v e p r o d u c t i o n c o p y i n g o r u s e o f t h i s d r a w i n g a n d d e s i g n s s h o w n t h e r e o n w i t h o u t w r i t t e n c o n s e n t o f

M a r k

L u s k

A r c h i t e c t u r e

P L L C i s p r o h i b i t e d a n d a n y i n f r i n g e m e n t i s s u b j e c t t o l e g a l a c t i o n

BRCC TEDC

ROOF

REPLACEMENT

CE

HCRADERET

GER T

IS IT

N OR T H C A R OL I

AN

KSULS.KRAM

S WA N N OA, NC

A N

52786

HCRAKSUL

KRAM

CL

LP

E, RUTCETI

CEHCRA

DERET

G E R

YN

AP

MO

C

LARUT

IS

IT

N OR T H C A R OL I

ANS WA N N OA, NC

A N

NORTH

ROOF PLAN

PROJECT NORTH

ROOF PLAN

SCALE: 1" = 10'-0"

R O

O F

D

E C

K

S L O

P E

R O

C

K

S L O

P E

9" W

34" H

13" W

35" H

13" W

24" H

13" W

30" H

32" H

9" W

34" H

RIDGE

SLOPE DN

SCUPPER (TYP)

CRICKET (TYP)

PSP (TYP)

COLUMN CURB & PSP (TYP)

SCREEN WALL:

20" ABOVE ROOF (TYP)

CONDUIT ON

RUBBER BLOCKS

1" RAISED AREA

STEEL (SATELLITE DISH)

FRAME ON PADS

1" RAISED EDGE

RD

RD

RD

RD

RD

RD

RD

TAPERED

INSULATION

9" W

15" H

9" W

48" H

SCUPPER

(TYP)

9" W

21" H

5" W CURB

21" H

EXPANSION JOINT BELOW ROOFING

20" H BOW

CRICKET

ROOF HATCH

3/A302

CRICKET

MECHANICAL

UNIT ON

CONCRETE

PAD

SEE LEGEND

EXISTING

ROOF

LADDER

REMOVE/

REINSTALL

FASTENERS

FOR

FLASHING

(RFG)

15" H BOW

24" H BOW (TYP)

I N

S U

L A

T I O

N

T

Y P

T A

P E

R E

D

9" W

34" H

9" W

40" H

4/A301

5" W CURB

13" H

MECHANICAL

UNIT CURB (TYP)

RD

SCUPPER (TYP)

13" W13" W

13" W

CRICKET

ROOF HATCH 3/A302

9" W CURB

9" H

4/A301

9" W

40" H

30" H

2" RAISED EDGE

7" RAISED EDGE

1.5" RAISED

EDGE

SLOPE DN (TYP)

PSP

RD

COLUMN CURB & PSP (TYP)

SCREEN WALL

20" ABOVE ROOF

32" H

4" CLEAR

CRICKET

40" H

R I D

G E

ROOF DECK

SLOPE

ROOF DECK

SLOPE

CRICKET

CRICKET

9" W

36" H

30" H

13" W

40" H

13" W

40" H

30" H

38" H

38" H

R O

C

K

S L O

P E

R O

C

K

S L O

P E

" RAISED AREA

34" H

13" H

CCCCC

STEEL FRAME

24" ABOVE ROOF

RIDGE

CONDUIT CURB

PARAPET (TYP)

I N

S U

L A

T I O

N

T A

P E

R E

D

SECOND STORY ROOF LEVEL- ROOF J

FIRST STORY ROOF LEVEL- ROOF E

PARAPET (TYP)

PV

ROOF H

ROOF I

ROOF K

ROOF G

ROOF F

THIRD STORY ROOF LEVEL

A302

TYP

A302

A301

TYP

A302

TYP

A301

TYP

4/A301

GENERAL NOTES

1. EXISTING WOOD NAILER SHALL REMAIN UNLESS DETERMINED TO BE DAMAGED BY ARCHITECT. REMOVAL AND REPLACEMENT SHALL BE PERFORMED AT UNIT PRICE.

2. VERIFY DIMENSIONS, QUANTITIES, SIZES, AND OTHER EXISTING CONDITIONS PRIOR TO DEMOLITION WORK. DISCREPANCIES BETWEEN DOCUMENTS AND EXISTING CONDITIONS SHALL BE REPORTED TO THE ARCHITECT.

3. SITE ACCESS, STAGING AND SCHEDULE SHALL BE COORDINATED WITH OWNER.

4. PROVIDE 18-8 OR 304 STAINLESS STEEL FASTENERS WHERE IN CONTACT WITH PRESSURE TREATED WOOD.

5. CONTRACTOR SHALL PERFORM ALL WORK IN COMPLIANCE WITH THE AHJ. COSTS FOR PERMITS SHALL BE INCLUDED IN WORK. PROVIDE INSPECTION DOCUMENTS TO THE OWNER.

6. BUILDING ELEMENTS ARE EXISTING.

ROOFING NOTES

1. EXISTING ROOFING COMPONENTS:

FULLY ADHERED SPM MEMBRANE

RIGID INSULATION

TAPERED INSULATION

ROOF I 3"-8"±

ROOF J 3"-12"±

ROOF E 3"-15"±

" FIBERGLASS BOARD

METAL ROOF DECK

2. DEMOLITION: REMOVE EXISTING ROOFING SYSTEM COMPONENTS INCLUDING TERMINATION

BARS & FLASHING. EXISTING SPM SHALL REMAIN.

3. PROVIDE FULLY ADHERED 60 MIL TPO MEMBRANE ROOFING SYSTEM, AND

" COVER BOARD

OVER EXISTING SPM ROOFING. ATTACH

" COVER BOARD THROUGH INTO EXISTING METAL

ROOF DECK. CUT OPEN EXISTING SPM.

LEGEND

PARAPET WALLS-

13" WIDE- 2/A301

9" WIDE- 1/A301

POWER CONDUIT 9/A301

BASE OF WALL FLASHING 3/A301

ROOF DRAIN 5/A301

SCUPPER-

13" PARAPET WALL- 7/A301

9" PARAPET WALL- 6/A301

PLUMBING VENT 2/A302

MECHANICAL UNIT CURB 4/A302

CONDUIT CURB SIM

MECHANICAL UNIT ON CONCRETE PAD

W/ CONDUIT PIPE. RAISE UNIT & PAD

FOR SPM WORK. REPLACE CONDUIT

PIPE BOOT.

POURABLE SEALER POCKET 7/A302

COL CURB PSP 8/A302

24"x24" WALKWAY PADS

BOW

RD

PV

C

C C

4/A301

5" W CURB

13" H

LARGE MECH

UNIT 9/A302

LARGE MECH

UNIT 9/A302

PV

ALTERNATE NO. 2-

REMOVE EXISTING SATELLITE SYSTEM.

DISH, BLOCKS, CONDUIT.

SWANNANOA, NC 28778

828.808.9757

MLARCHITECTURE@CHARTER.NET

C o p y r i g h t l

R i g h t s

R e s e r v e p r o d u c t i o n c o p y i n g o r u s e o f t h i s d r a w i n g a n d d e s i g n s s h o w n t h e r e o n w i t h o u t w r i t t e n c o n s e n t o f

M a r k

L u s k

A r c h i t e c t u r e

P L L C i s p r o h i b i t e d a n d a n y i n f r i n g e m e n t i s s u b j e c t t o l e g a l a c t i o n

BRCC TEDC

ROOF

REPLACEMENT

CE

HCRADERET

GER T

IS IT

N OR T H C A R O L I

AN

KSULS.KRAM

SWA N N OA, N C

A N

52786

HCRAKSUL

KRAM

CL

LP

E, RUTCETI

CEHCRA

DERET

GE R

YN

AP

MO

C

LARUT

IS

IT

N OR T H C A R O L I

ANSWA N N OA, N C

A N

DETAILS

DISKS W/ FASTENERS

FULLY ADHERED SINGLE-PLY MEMBRANE

EXISTING METAL DECK

FLASHING- EXTEND OVER PARAPET

EXISTING WOOD NAILERS

REPLACE EXISTING METAL COPING. SEE ROOF PLANS FOR WIDTH.

HEIGHT VARIES- SEE ROOF PLANS

" COVER BOARD- MECHANICALLY ATTACH INTO EXISTING METAL DECK

EXISTING RIGID INSULATION - 3"

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING PARAPET WALL

EXISTING

" FIBERGLASS BOARD

EXISTING METAL STUD WALL

SCALE: 1

" = 1'-0"

PARAPET WALL

SCALE: 1

" = 1'-0"

BASE OF WALL DETAIL

2" DISC W/ FASTENERS

FULLY ADHERED SINGLE-PLY MEMBRANE

" COVER BOARD

MECHANICALLY ATTACH INTO EXISTING METAL ROOF DECK

REMOVE & REINSTALL EXISTING COUNTERFLASHING (RIVETS)

TERMINATION BAR W/ FASTENERS & SEALANT

ADHERE MEMBRANE FLASHING TO WALL

EXISTING METAL SIDING

EXISTING METAL STUD WALL

EXISTING WOOD NAILERS

EXISTING

" SHEATHING

EXISTING METAL DECK

EXISTING RIGID INSULATION - 3"

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING WOOD NAILER

EXISTING METAL FRAMING

HEIGHT VARIES - SEE ROOF PLANS

FLASHING- EXTEND OVER EXISTING CURB WALL

DISKS W/ FASTENERS

FULLY ADHERED SINGLE-PLY MEMBRANE

EXISTING METAL DECK

" COVER BOARD- MECHANICALLY

ATTACH INTO EXIST'G ROOF DECK

SCALE: 1

" = 1'-0"

CURB WALL

EXISTING SPM SHALL REMAIN-

CUT OPEN

EXISTING

" FIBERGLASS BOARD

SCALE: 1

" = 1'-0"

PARAPET WALL

EXISTING METAL STUD WALL

2" DISC W/ FASTENERS

EXISTING METAL SIDING

REPLACE EXISTING METAL COPING

EXISTING

" SHEATHING

FULLY ADHERED SINGLE PLY MEMBRANE

" HD COVERBOARD

MECHANICALLY ATTACH

INTO EXISTING METAL DECK

EXISTING METAL DECK

EXTEND MEMBRANE FLASHING OVER PARAPET

EXISTING RIGID INSULATION - 3"

EXISTING

" FIBERGLASS BOARD

EXISTING SPM SHALL REMAIN-

CUT OPEN

REMOVE/ REINSTALL

EXISTING FASTENERS

H E

I G

H T

V

R

I E

S

S

P

L A

N S

NOTES:

1. MATCH EXISTING COPING PROFILE

2. REMOVE EXISTING MEMBRANE FLASHING

3. INSULATION THICKNESS VARIES AT

CRICKETS & TAPERED INSULATION (RFS E,I,J)

EXISTING

" SHEATHING

REPLACE EXISTING METAL COPING

SCALE: 1

" = 1'-0"

ROOF DRAIN DETAIL

EXISTING ROOF DRAIN STRAINER

EXISTING SLOPE TO ROOF DRAIN

FULLY ADHERED SINGLE PLY MEMBRANE

EXISTING METAL ROOF DECK

REPLACE EXISTING CLAMP RING BOLTS

EXISTING R.D. BOWL

EXISTING R.D.

LEADER PIPE

REMOVE AND REINSTALL EXISTING CLAMP RING

EXISTING RIGID INSULATION - 3"

WATER

CUT-OFF

EXISTING SPM SHALL REMAIN - CUT OPEN

" HD COVERBOARD - MECHANICALLY ATTACH

INTO EXISTING METAL ROOF DECK

SEE ROOF PLANS

EXISTING WOOD NAILER

EXISTING WOOD NAILER

SEE ROOF PLANS

EXISTING

" FIBERGLASS BOARD

NOTE:

1. REMOVE EXISTING MEMBRANE FLASHING

EXISTING CONDITION VARIES

HEIGHT VARIES- SEE ROOF PLANS

SEE ROOF PLANS

NOTE:

1. REMOVE EXISTING MEMBRANE FLASHING

EXISTING WOOD NAILERS

NOTE:

1. REMOVE EXISTING MEMBRANE FLASHING

2" DISC W/

FASTENERS

EXISTING METAL SIDING

EXISTING

" SHEATHING

FULLY ADHERED SINGLE PLY MEMBRANE

" HD COVERBOARD

MECHANICALLY ATTACH INTO EXISTING METAL DECK

EXISTING METAL DECK

EXISTING RIGID INSULATION - 3"

EXISTING

" FIBERGLASS BOARD

EXISTING SPM SHALL REMAIN- CUT OPEN

NOTES:

1. MATCH EXISTING COPING PROFILE

2. REMOVE EXISTING MEMBRANE FLASHING

EXISTING WOOD NAILER

SCALE: 1

" = 1'-0"

OVERFLOW SCUPPER

EXTEND FLASHING IN SCUPPER 3" MIN

FLASHING AT SCUPPER

EXISTING 8"x5" METAL

SCUPPER

SEALANT

SCALE: 1

" = 1'-0"

OVERFLOW SCUPPER

DISKS W/

FASTENERS

FULLY ADHERED SINGLE-PLY MEMBRANE

EXISTING METAL DECK

" COVER BOARD

MECHANICALLY ATTACH INTO

EXISTING METAL DECK

EXISTING RIGID INSULATION - 3"

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING PARAPET WALL

EXISTING

" FIBERGLASS BOARD

EXISTING METAL STUD WALL

EXISTING

" SHEATHING

NOTE:

1. REMOVE EXISTING MEMBRANE FLASHING

EXTEND FLASHING IN SCUPPER 3" MIN

FLASHING AT SCUPPER

EXISTING 8"x5" METAL

SCUPPER

SEALANT

SCALE: 1

" = 1'-0"

TRANSITION - STEP

DISKS W/ FASTENERS

FULLY ADHERED SINGLE-PLY MEMBRANE

EXISTING METAL DECK

" COVER BOARD- MECHANICALLY

ATTACH INTO EXIST'G ROOF DECK

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING

" FIBERGLASS BOARD

EXISTING WOOD NAILERS

MEMBRANE FLASHING

EXISTING 2" CONCRETE

NOTE:

1. REMOVE EXISTING MEMBRANE FLASHING

EXISTING METAL STUD WALL

SCALE: 1

" = 1'-0"

FIELD FLASHING PIPE DETAIL

NOTE:

1. REMOVE EXISTING FIELD FLASHING

FULLY ADHERED SINGLE-PLY MEMBRANE

FIELD FLASHING

" COVER BOARD

MECHANICALLY ATTACH INTO EXISTING METAL ROOF DECK

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING

" FIBERGLASS BOARD

EXISTING RIGID INSULATION - 3"

EXISTING METAL DECK

EXISTING METAL CONDUIT

EXISTING RIGID INSULATION - 3"

STAINLESS STEEL CLAMP

EXISTING

" FIBERGLASS BOARD

NOTES:

1. REMOVE EXISTING MEMBRANE FLASHING

2. INSULATION THICKNESS VARIES AT

CRICKETS & TAPERED INSULATION (RFS C,D)

TOP OF 12" WALL AT ROOF A

12"±

EXISTING METAL SIDING

SHALL REMAIN

EXISTING PARAPET WALL

SWANNANOA, NC 28778

828.808.9757

MLARCHITECTURE@CHARTER.NET

C o p y r i g h t l

R i g h t s

R e s e r v e p r o d u c t i o n c o p y i n g o r u s e o f t h i s d r a w i n g a n d d e s i g n s s h o w n t h e r e o n w i t h o u t w r i t t e n c o n s e n t o f

M a r k

L u s k

A r c h i t e c t u r e

P L L C i s p r o h i b i t e d a n d a n y i n f r i n g e m e n t i s s u b j e c t t o l e g a l a c t i o n

BRCC TEDC

ROOF

REPLACEMENT

CE

HCRADERET

GER T

IS IT

N OR T H C A R O L I

AN

KSULS.KRAM

SWA N N OA, N C

A N

52786

HCRAKSUL

KRAM

CL

LP

E, RUTCETI

CEHCRA

DERET

GE R

YN

AP

MO

C

LARUT

IS

IT

N OR T H C A R O L I

ANSWA N N OA, N C

A N

DETAILS

SCALE: 1

" = 1'-0"

TRANSITION - TAPER

FULLY ADHERED SINGLE-PLY MEMBRANE

EXISTING METAL DECK

" COVER BOARD- MECHANICALLY ATTACH INTO EXIST'G ROOF DECK

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING

" FIBERGLASS BOARD

EXISTING WOOD NAILERS

EXISTING 2" CONCRETE

EXISTING TAPERED RIGID INSULATION

EXISTING RIGID INSULATION - 3"

STAINLESS STEEL CLAMPING

EXISTING VENT THROUGH ROOF

SIZE VARIES

PRE-MOLDED PIPE SEAL

CAULK

FULLY ADHERED SINGLE PLY MEMBRANE

EXISTING METAL ROOF DECK

PLUMBING VENT DETAIL

SCALE: 1

" = 1'-0"

NOTES:

1. RAISE VENT PIPE TO 8" ABOVE ROOFING

2. REMOVE EXISTING PRE-MOLDED PIPE SEAL

" COVER BOARD

MECHANICALLY ATTACH INTO EXISTING METAL ROOF DECK

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING

" FIBERGLASS BOARD

EXISTING RIGID INSULATION - 3"

SCALE: 1

" = 1'-0"

ROOF HATCH

REPLACE NEOPRENE EXPANSION TUBING

SELF FLASHING ROOF HATCH CURB

2" DISC W/ FASTENERS

NOTE:

1. REMOVE EXISTING FLASHING

2. ALT. NO. 1- REPLACE HATCH RAIL SYSTEM

FULLY ADHERED SINGLE PLY MEMBRANE

" COVER BOARD

MECHANICALLY ATTACH INTO EXISTING METAL ROOF DECK

EXISTING METAL DECK

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING

" FIBERGLASS BOARD

EXISTING RIGID INSULATION - 3"

EXTEND FLASHING UNDER EXISTING ROOF HATCH CURB

SCALE: 1

" = 1'-0"

MECHANICAL UNIT CURB

REMOVE AND REINSTALL EXISTING MECHANICAL UNIT

2" DISC W/ FASTENERS

FULLY ADHERED SINGLE PLY MEMBRANE

" COVER BOARD

MECHANICALLY ATTACH INTO EXISTING METAL ROOF DECK

EXISTING METAL DECK

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING

" FIBERGLASS BOARD

EXISTING RIGID INSULATION - 3"

EXTEND FLASHING OVER CURB

NOTES:

1. REMOVE EXISTING FLASHING

2. DISCONNECT/CONNECT EXISTING MECHANICAL UNIT POWER BY LICENSED ELECTRICIAN.

EXISTING PRE FAB. CURB

SCALE: 1

" = 1'-0"

ROOF H

SEALANT

TERMINATION BAR W/ FASTENERS

ADHERE MEMBRANE FLASHING TO WALL

FLASHING

2" DISC W/ FASTENERS

FULLY ADHERED SINGLE-PLY MEMBRANE

" COVER BOARD- MECHANICALLY ATTACH INTO EXISTING METAL ROOF DECK

EXISTING TAPERED RIGID INSULATION- 2" MIN

EXISTING BRICK VENEER WALL

COUNTERFLASHING

EXISTING METAL ROOF DECK

EXISTING

" FIBERGLASS BOARD

8" MIN ABOVE ROOFING

METAL FASCIA

SCALE: 1

" = 1'-0"

MECHANICAL SUPPORT CURB

EXISTING WOOD NAILERS

REMOVE/ REINSTALL EXISTING MECHANICAL UNIT

REPLACE EXISTING METAL COPING

EXISTING METAL DECK

EXISTING

" FIBERGLASS BOARD

NOTE:

1. REMOVE EXISTING MEMBRANE FLASHING

EXISTING WOOD NAILERS

FULLY ADHERED SINGLE-PLY MEMBRANE

" COVER BOARD- MECHANICALLY

ATTACH INTO EXIST'G ROOF DECK

EXISTING SPM SHALL REMAIN-

CUT OPEN

FLASHING- EXTEND OVER EXISTING CURB WALL

DISKS W/ FASTENERS

EXISTING RIGID INSULATION - 3"

SCALE: 1

" = 1'-0"

POURABLE SEALER POCKET

6" SQUARE STEEL COLUMN

METAL DAM

FULLY ADHERED SINGLE PLY MEMBRANE

EXISTING CONCRETE

POURABLE SEALER 2" MIN.

3" MIN

PRESSURE SENSITIVE FLASHING

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING RIGID INSULATION - 3"

" COVER BOARD - MECHANICALLY

ATTACH INTO EXISTING METAL ROOF DECK

SCALE: 1

" = 1'-0"

COLUMN CURB & PSP

DISKS W/ FASTENERS

FULLY ADHERED SINGLE-PLY MEMBRANE

EXISTING METAL DECK

" COVER BOARD- MECHANICALLY

ATTACH INTO EXIST'G ROOF DECK

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING

" FIBERGLASS BOARD

EXISTING WOOD NAILERS

MEMBRANE FLASHING

EXISTING 2" CONCRETE

NOTE:

1. REMOVE EXISTING MEMBRANE FLASHING

EXISTING RIGID INSULATION - 3"

POURABLE SEALER 2" MIN.

PRESSURE SENSITIVE FLASHING

6" SQUARE STEEL COLUMN

METAL DAM

EXISTING BLOCKING

3"

NOTE:

1. REMOVE EXISTING FLASHING, T-BAR, METAL FASCIA

EXISTING PREFAB CURB

EXISTING WOOD NAILERS

EXISTING WOOD NAILERS

EXISTING WOOD NAILERS

SCALE: 1

" = 1'-0"

LARGE MECHANICAL UNIT

2" DISC W/ FASTENERS

NOTE:

1. REMOVE EXISTING FLASHING

FULLY ADHERED SINGLE PLY MEMBRANE

" COVER BOARD

MECHANICALLY ATTACH INTO EXISTING METAL ROOF DECK

EXISTING METAL DECK

EXISTING SPM SHALL REMAIN - CUT OPEN

EXISTING 2" CONCRETE

EXISTING RIGID INSULATION - 3"

ADHERE FLASHING TO EXISTING CURB

EXISTING PREFAB CURB

EXISTING WOOD NAILERS

TERMINATION BAR W/ FASTENERS

SEALANT

EXISTING MECHANICAL UNIT

COUNTERFLASHING (REPOSITION EXISTING FLEXIBLE POWER CONDUIT)

REPLACE EXISTING HATCH RAIL SYSTEM- INSTALL ON ROOF HATCH CURBS