1-072426 2024-1034 RR CROSSING PLAN.pdf
PDF 3 MB Posted
- Attached to
- Oliver Township Municipal Authority - North Front Street Sanitary Sewer Railroad Crossing Replacement
- Solicitation number
- Not on record
- Issued by
- Pennsylvania
About this file
This is a railroad crossing replacement plan prepared by JHA Companies for Oliver Township Municipal Authority in Perry County, Pennsylvania, involving the replacement of an underground sanitary sewer main that crosses Norfolk Southern Railroad right-of-way. The project, identified as 2024-1034, involves the replacement of approximately 90 linear feet of gravity wastewater carrier pipe currently housed within an existing 16-inch steel casing, replacement of precast manhole risers as necessary to accommodate the new carrier pipe, and all related construction work as detailed in the contract drawings and specifications. The project is located in Oliver Township on North Front Street, with two railroad grade crossings identified as 506595J and 506596R at milepost NS 132. The plan was dated May 15, 2026, with a revision issued June 4, 2026, per RailPros specifications. The crossing agreement references Norfolk Southern Railroad, Inc., with agreement designation and valuation mapping information provided for Oliver Township, Perry County, Pennsylvania.
The project must comply with Norfolk Southern's NSCE specifications and American Railway Engineering and Maintenance of Way Association standards for pipeline installations. Excavation work is shown outside all theoretical embankment zones with specific shoring requirements identified in three zones, prohibiting blasting operations. Two sanitary manhole structures (MH#114 and MH#115) require replacement in kind, with excavation pits measuring 10 feet by 30 feet established for construction access. The design includes 8-inch truss pipe for the sanitary main with stainless steel spacers and end wraps, and a 4-inch PVC cleanout positioned 2.5 feet above ground. Engineering and design oversight was provided by JHA Companies, with professional engineer certification and signature requirements documented on the plans.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-Specifications - N Front St Sanitary Sewer RR Crossing Replacement.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE LOCATION
1" = XX'
JHA
2026-02-19
2024-1034
844-542-4757
MD NY OH PA VA WV
www.jhacompanies.com
CAMP HILL, PA 17001
3705 E TRINDLE ROAD #100
LOCATED IN
OLIVER TOWNSHIP, PERRY COUNTY,PA. 17074
OLIVER TWP. MUNICIPAL AUTH.
FOR
N. FRONT ST. SAN. SEWER
RAILROAD CROSSING
REPLACEMENT
LOCATION PLAN
LP-1
400 400 800
GRAPHIC SCALE: 1" =
400'
717-567-7098
615 S. THIRD ST., P.O. BOX 126
NEWPORT, PA 17074
SS
S S S S S S
S
S
S
S
S S
NORFOLK SOUTHERN
RAILROAD
MA
LLA
RD
DR
IVE
(P
AV
E)
85'
SAN. MH 114
RIM = 394.49'
(REPLACE IN KIND)
EDGE OF WOODS
LAWN
AREA
DITCH
CENTERLINE
#780
CANVASBACK DR.
LAWN
AREA
LAWN
AREA
PR. 8" PVC
C-900 DR 14,
CCI STAINLESS
STEEL SPACERS
W/ END WRAPS
GRAVEL DRIVE
SHED
RAILROAD R.O.W. (195' WIDTH)
N/F
BRIDGEWAY MHP LLC
200,46.2-254
N/F
CONRAIL PROPERTY TAX
200,46.2-281
N/F
CONRAIL PROPERTY TAX
200,60-12.1
N/F
BRIDGEWAY MHP LLC
200,46.2-254
90.3°
PIPE CROSSING LOCATION
40.587583° N, 77.136185° W
T
O
G
R A
D E
C R
O S
S I N
G
J
0+00
0+50 1+00
1+501 +53
4" PVC CLEANOUT
(2.5' ABOVE GROUND)
FLOW
EX. 8" TP*
SAN. MAIN
EX. 16" STEEL CASING
(85 LF)
SAN. MH 115
RIM = 393.76'
(REPLACE IN KIND)
OFFSET MANHOLE
EX. 8" TP* SAN. MAIN
FLOW
10' x 30' EXCAVATION PIT
10' x 30'
EXCAVATION PIT
EX. 8" CAST IRON PIPE (CIP)
SANITARY SEWER
EX. SAN. LATERAL
EX. SAN.
LATERAL
T
O
G
R A
D E
C R
O S
S I N
G
R
S S S S
*TP = TRUSS PIPE
RAILROAD R.O.W. (66' WIDTH)
ROW WIDENS
40.587569° N, 77.136063° W
12'
36'
37'
21'
33'
EXIHIBIT
OLIVER TOWNSHIP,
PERRY COUNTY,
PENNSYLVANIA 17074
717-567-7098
615 S. THIRD ST., PO BOX 126
NEWPORT, PA 17074
1" = 20' CK
PF
JDK
05/15/2026
2024-1034
OLIVER TWP. MUN. AUTH.
FOR
MD NY OH PA VA WV
844-542-4757 www.jhacompanies.com
3705 E TRINDLE RD # 100
CAMP HILL, PA 17001
N. FRONT ST.
SAN. SEWER
RAILROAD CROSSING
REPLACEMENT
LOCATED IN
C-1
NORTH
Exhibit A Norfolk Southern Railroad, INC.
Underground Sanitary Main Crossing Agreement with
Oliver Twp. Municipal Authority
Agreement No. _ _ _ _ _
Milepost: NS 132
Valuation Station: 97
Valuation Map: 210213210
Oliver Township
Perry County, Pennsylvania
Exhibit Date: 05/15/2026
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
PLAN STATUS:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT ID:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DESIGN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
INT.
AutoCAD SHX Text
AutoCAD SHX Text 2026-05-15
AutoCAD SHX Text
ORIGINAL
AutoCAD SHX Text
JDK
AutoCAD SHX Text
PROFESSIONAL ENGINEERS SEAL AND SIGNATURE
AutoCAD SHX Text
AutoCAD SHX Text 2026-06-04
AutoCAD SHX Text
REV. PER RAILPROS
AutoCAD SHX Text
ERB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRAPHIC SCALE: 1" =
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 20'
GENERAL NOTES Exhibit A Norfolk Southern Railroad, INC.
1. CONTRACTOR SHALL FOLLOW AL REQUIREMENTS OF NORFOLK SOUTHERN'S NSCE� SPECIFICATIONS
2. PIPELINE AND CROSSING TO BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH LAST APPROVED AMERICAN RAILWAY ENGINEERING & MAINTENANCE OF WAY ASSOCIATION SPECIFK:ATIONS FOR
PIPELINES CONVEYING FLAMMABLE AND NON-FLAME SUBSTANCES
3. BIASTING NOT PERMITTEO
ROADBED PROFILE - SHORING REQUIREMENTS:
1. EXCAVATION OUTSIDE OF ZONE 1 MAY REQUIRE SHORING FOR SAFETY. LATERAL PRESSURES DUE TO TRAIN LOADING 00 AFFECT SHORING DESIGN OUTSlOE OF ZONE 1
2. REFER TO PUBLIC PROJECT MANUAL APPENDIX H, SECTION H.1.6.A. (OVERHEAD BRIDGE) OR SECTION H.2.BA (UNDERPASS BRIDGE) ANO APPENDIX H FOR ADOmONAL SHORING REQUIREMENTS
3. ALL EXCAVATION FOR THIS PROJECT IS OUTSIDE OF ALL ZONES OF THE THEORETICAL EMBANKMENT LINE.
ZONE 1: EXCAVATION WITHIN ZONE 1 WILL REQUIRE SHORING FOR THE PROTECTION OF THE RAILROAD.
ZONE 2: EXCAVATION WITHIN ZONE 2 WILL REQUIRE SHORING CONSISTING OF INTERLOCKING SHEETING FOR THE PROTECTION Of THE RAILROAD
ZONE 3: NO EXCAVATION WILL ALLOWED IN ZONE 3
RAILROAD ROW RAILROAD CENTERLINE
Elev=396 32 \ Elev=396 16 \ r BOTTOM OF RAIL / Elev=396.21'
RAILROAD ROW
r Elev=394 89 398
\ 21'vj· 12'...,_1--,,..../--33' I n -
'iJ / 14\
396 SAN. M!V#115 / I
v
I ,� f-li1-10' - SAN. MH#114 396 tam- �:to).//:) - / /B _,_ n .. ·--- - -
,,.._ \ � llf(tm.;;.;:,,;,,;:, '"ln
{�EPLACE I� KIND) '1--r11-/+----+--
_,:37 ., --+---t \ i----+---+-"-+- 36, ____,.,,._, {REPLACE IN �IND)
�j"-f'.:: ..... �·-.�==:===:tr---1:....:-+-.::::.f-l/-++- --+-+--+-+--+- -+---41-....:....__ EXCAVATl�N PIT 'r- - 394 I / I {10'x30')
��� I
EX 8" CAST ----------.. I •
--192 , IRON PIPE (CIP) \. - STONf BA�E I
' \,, �I I 39 1--�t-------,t----+-t---+---+"-=-+--+----+J++_SAN SEVVER w+--+-it-------t-t--'+---+----+--+H----t-+----+-+--------1
' --<"' I I
� I / [�o&"t:f4 � 1 J ' 1 1 I '° / CCI STAINLESS THEORETICAL R.R \ I 390 , STEEL SPACERS EMBANKMENT L:NE 1\ N � 39d
I� I n-
--+--W/ END WRAPS) ,_ 2 (H\ TO 1 (V) SLOPE---✓-,,.....,4.
---++-+-,--+-oo�----- -""',_'-+-+- --4-1, Joo t / /----66"R.R R.6.w. I I I \ I I I
'-fO"' !CLOW --'r-t ,--.++--+-----+-+-3_8_8.....--1
�1;::::==��=i:=l:=:lt"'>,. I ,' ' I I
I
-486- - - ,_ - - �r-,· r---t-7�==�7�1 +:t===�' �I --r--- I ".>8
J .J - .' EX.16" STEEL I ---- FLo--,.i,....;i_ IQ
TP = TRUSS PIPE
I
1./ \ ----!.---CASING PIPE 1r , 8" TP (/NV � l I I J �•---ZONE 3 ·,--, >, ,.. ) g��86.43 384
"----ZONE 1 _/ \_ ZONE 2 ZO E 2 ___J '-ZONE 1 _/ I
PROFILE VIEW
(ELEVATION LOOKING NORTH WEST)
SCALE 1' = 20' (HORIZONTAL), 1" = 4' (VERTICAL)
GRAPHIC SCALE: 1" = 20'- --
Underground Sa,itary Main Crossing Agreement with
Oliver Twp. Municipal Authority
Agreement No. ____ _
Milepost: NS 132
Valuation Station: 97
Valuation Map: 210213210
Oliver Township
Perry County, Pennsylvania
Exhibit Date: 05/15/2026
2024-1034 - JDK
05/15/2026 - PF
91112
1" = 20' -CK
717-567-7098
615 S. THIRD ST., PO BOX 126
NEWPORT, PA 17074
llit.JHASIJR\/E'11MG .11111111111111 ■ OJCi!NU:RJ.NG
■ � EN\llRONr--:FNTAL
� ARa-lITECllJRE
-.jhii1XN'npf"'1IM.1XN'11, M4-512◄757
3705 E TRINDLE RD# 100
CAMP HILL, PA 17001
MO• NY• OH• PA• VA• WV
N. FRONT ST.
SAN. SEWER
RAILROAD CROSSI NG
REPLACEMENT
FOR
OLIVER TWP. MUN. AUTH.
LOCATED IN
OLIVER TOWNSHIP,
PERRY COUNTY,
PEN NSYLV/>NIA 17074
1'1111 Slll!US: HD'ID.
20 0 20 40 EXIHIBIT C-2
| Sheets and Views |
| RR CROSSING PLAN (OLIVER TWP MUN AUTH) 8.5X11 LANDSCAPE-C-1 |
| RR CROSSING PLAN (OLIVER TWP MUN AUTH) 8.5X11 LANDSCAPE-C-2 |
File details come from the government source that posted it. Updated .