About this file

This document provides specifications for a federal construction project to modernize finishes at a Veterans Affairs medical center in Columbus, Ohio. The project scope includes replacing flooring and resilient base in public areas of the first floor, and will take place at the Chalmers P. Wylie VA Ambulatory Care Center. The solicitation number is 36C25021B0029 and it is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses, who must be small under NAICS code 238330 with a size standard of $16.5 million. The SDVOSB is required to perform a minimum of 25% of the construction work. Bid, payment and performance bonds will be required. The estimated value is between $250,000 and $500,000. A pre-bid site visit will be scheduled and the solicitation will be posted on SAM.gov on or around March 22nd 2021 with bids due approximately 30 days later. Questions are due in writing to the contracting officer by the specified deadline.

View the file

Other files

File Type Posted
36C25021B0029 0001.docx DOCX document
Drawings - Combined.pdf PDF
096800 Capreting Specs - UPDATED.docx DOCX document
36C25021B0029_1.docx DOCX document
VAACC Health Requirements FINAL.docx DOCX document
VHA Directive 1192.01, Seasonal Influenza Prevention Program for VHA Health Care Personnel.pdf PDF
096519 Resilient Tile Flooring Specs.docx DOCX document
Franklin WD 02.26.2021.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

01-01-21

SECTION 09 65 13

RESILIENT BASE AND ACCESSORIES

GENERAL

SUMMARY

Section Includes:

Resilient base (RB) adhered to interior walls and partitions.

RELATED REQUIREMENTS

Sheet Flooring Integral Base: Section 09 65 16, RESILIENT SHEET FLOORING.

APPLICABLE PUBLICATIONS

Comply with references to extent specified in this section.

ASTM International (ASTM):

F134415Rubber Floor Tile.
F185914e1Rubber Sheet Floor Covering without Backing.
F186014e1Rubber Sheet Floor Covering with Backing.
F186116Resilient Wall Base.
D425918Preparation of Concrete by Abrasion Prior to Coating Application.

Federal Specifications (Fed. Spec.):

RRT650E (1994) Treads, Metallic and NonMetallic, SkidResistant.

International Concrete Repair Institute (ICRI):

310.2R2013 Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, Polymer Overlays, and Concrete Repair.

SUBMITTALS

Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

Manufacturer's Literature and Data:

Description of each product.

Adhesives and primers indicating manufacturer's recommendation for each application.

Installation instructions.

Samples:

Resilient Base: 150 mm (6 inches) long, each type and color.

Operation and Maintenance Data:

Care instructions for each exposed finish product.

DELIVERY

Deliver products in manufacturer's original sealed packaging.

Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date.

Before installation, return or dispose of products within distorted, damaged, or opened packaging.

STORAGE AND HANDLING

Store products indoors in dry, weathertight facility.

Protect products from damage when handling and during construction operations.

FIELD CONDITIONS

Environment:

Product Temperature: Minimum 21 degrees C (70 degrees F) for minimum 48 hours before installation.

Work Area Ambient Temperature Range: 21 to 27 degrees C (70 to 80 degrees F) continuously, beginning 48 hours before installation.

Install products when building is permanently enclosed and when wet construction is completed, dried, and cured.

WARRANTY

Construction Warranty: FAR clause 52.24621, "Warranty of Construction."

PRODUCTS

PRODUCTS

Johnsonite/Tarkett Millwork Resilient Wall Base, Inflection Profile, 5.25”H, .375”D, Color: 11 Canvas Basis of Design: Section 09 06 00, SCHEDULE FOR FINISHES.

Provide each product from one manufacturer and from one production run.

Sustainable Construction Requirements:

Low PollutantEmitting Materials: Comply with VOC limits specified in Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS for the following products:

Flooring Adhesives and Sealants.

RESILIENT BASE

Resilient Base: .375” thick, 5.25” high.

Type: Rubber or vinyl; use one type throughout.

ASTM F1861, Type TP thermoplastic rubber or Type TV thermoplastic vinyl, Group 2 - layered.

PRIMER (FOR CONCRETE FLOORS)

Primer: Type recommended by adhesive manufacturer.

LEVELING COMPOUND (FOR CONCRETE FLOORS)

Leveling Compound: Provide products mixed with latex or polyvinyl acetate resins.

ADHESIVES

Adhesives: Low pollutantemitting, water based type recommended by adhered product manufacturer for each application.

EXECUTION

PREPARATION

Examine and verify substrate suitability for product installation.

Protect existing construction and completed work from damage.

Remove existing base to permit new installation.

Dispose of removed materials.

Correct substrate deficiencies.

Fill cracks, pits, and depressions with leveling compound.

Remove protrusions; grind high spots.

Apply leveling compound to achieve 3 mm (1/8 inch) in 3 m (10 feet) maximum surface variation.

Clean substrates. Remove contaminants capable of affecting subsequently installed product's performance.

Mechanically clean concrete floor substrate according to ASTM D4259.

Surface Profile: ICRI Guideline No. 310.2R.

Allow substrate to dry and cure.

Perform flooring manufacturer’s recommended bond, substrate moisture content, and pH tests.

INSTALLATION GENERAL

Install products according to manufacturer's instructions.

When instructions deviate from specifications, submit proposed resolution for Contracting Officer consideration.

RESILIENT BASE INSTALLATION

Applications:

Install resilient base in rooms scheduled on Drawings.

Install resilient base on casework and other curb supported fixed equipment.

Extend resilient base into closets, alcoves, and cabinet knee spaces, and around columns within scheduled room.

Lay out resilient base with minimum number of joints.

Length: 600 mm (24 inches) minimum, each piece.

Locate joints 150 mm (6 inches) minimum from corners and intersection of adjacent materials.

Installation:

Apply adhesive uniformly for full contact between resilient base and substrate.

Set resilient base with hairline butted joints aligned along top edge.

// Field // Factory // form corners and end stops.

Vgroove back of outside corner.

Vgroove face of inside corner and notch cove for miter joint.

Roll resilient base ensuring complete adhesion.

- E N D -