0901_SHAFT SEAL INSPECTION.pdf

PDF 98 KB Posted

Attached to
SSU25-013 USNS MATTHEW PERRY SHAFT SEAL INSPECTION
Solicitation number
N4044625Q0006
Issued by

About this file

This is a Statement of Work detailing requirements for shaft seal inspection services aboard the USNS Matthew Perry (TAKE 9) at Tango Pier in Guam. The work involves inspecting the ship's shaft seal closed loop system, including examination of external piping, fittings, pipe hangers exterior of the hull aft of shaft alley Frame 85 to the stern tube, as well as inspection of all welds, the Stern Tube Aft Seal Adapter Plate, and protective covering of the STFW system aft seal supply piping.

The work is scheduled for February 22-24, 2025 and requires coordination with ship's force for equipment lockout/tagout procedures. A Pre-Dive Planning Meeting must be conducted with key stakeholders to discuss communications, emergency procedures, vessel drafts, clearances, and tides/currents. The contractor must submit inspection reports electronically in PDF format with photographs. Special safety considerations include high voltage electrical systems with non-standard color coding. The point of contact is Ed Madrelino at the provided Navy email and phone numbers. No government furnished equipment is provided, and there are no additional quality assurance requirements beyond those specified in the General Technical Requirements.

View the file

Other files

File Type Posted
N4044625Q0006 Amendment 3.pdf PDF
N4044625Q0006 Amendment 2.pdf PDF
0901_SHAFT SEAL INSPECTION - Rev 1.pdf PDF
N4044624Q0011 Amendment 1.pdf PDF
N4044625Q0006.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USNS Matthew Perry

( TAKE 9 )

SSU25-013

ITEM NO. 0901 CATEGORY "A" 0202-02-20

SHAFT SEAL INSPECTION MH-GUAM

0958 - 1

1.0 ABSTRACT

The purpose of this item is to inspect the ship’s shaft seal closed loop system.

2.0 REFERENCES/ENCLOSURES

2.1 Available onboard

3.0 ITEM LOCATION/DESCRIPTION

3.1 Location/Quantity

3.1.1 Location: Underwater Hull

4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICE: None

5.0 NOTES

5.1 The contractor and all subcontractors, regardless of

tier must consult the General Technical Requirements (GTR) to determine applicability to this work item. In performance of this work item, the contractor and all subcontractors regardless of tier must comply with the requirements of all applicable GTRs including but not limited to GTRs 1 through 7, 22, 23, 24, 28, and 29.

5.2 The contractor and all subcontractors regardless of

tier are advised to review other work items under this contract, Many of the definitions relating to performance of this work item are found in Work Item 001.

SSU25-013

0958 - 2

5.3 THIS SHIP CONTAINS HIGH VOLTAGE (HV) ELECTRICAL

SYSTEMS. OBEY ALL POSTED AND VERBAL INSTRUCTIONS REGARDING

SAFETY AND EXCLUSION FROM HIGH VOLTAGE AREAS. AT NO TIME

APPROACH, WORK ON, OR ENTER A HIGH VOLTAGE AREA WITHOUT PROPER

AUTHORIZATION.

5.4 THE T-AKE CLASS ELECTRICAL COLOR CODING DOES NOT

FOLLOW CONSISTENT COLOR SCHEME. THE SHIP IS KNOWN TO HAVE

CURRENT CARRYING CONDUCTORS COLORED GREEN, BLUE, BLACK, AND

WHITE. ASSUME ALL ELECTRICAL CABLES ARE ENERGIZED UNTIL TESTED

AND PROVEN OTHERWISE. TEST ALL ELECTRICAL CABLES TO ENSURE THEY

ARE DE-ENERGIZED PRIOR TO WORKING ON THE ITEM.

6.0 QUALITY ASSURANCE REQUIREMENTS: None additional

7.0 STATEMENT OF WORK REQUIRED

7.1 Coordinate with ship’s force to have associated

equipment locked and/or tagged out per ship’s lock out/tag out policy. When the maintenance is complete, coordinate with ship’s force to have associated equipment unlocked and/or tagged in per ship’s lock out/tag out policy.

7.2 Conduct a Pre-Dive Planning Meeting with the Diver’s

Representative, Master, Chief Engineer and OMT REP. The meeting agenda and discussion covers, at a minimum:

7.2.1 Discuss means of communication between the

Bridge, Dive Team, and Engine Room.

7.2.2 Discuss procedures/plans for emergencies.

7.2.3 Discuss the vessel’s anticipated drafts, pier-

side clearance, and under-keel clearance at the time of the cleaning.

7.2.4 Discuss impact of the tides and currents on

divers and the examination.

7.2.5 Discuss anticipated duration of the underwater

SSU25-013

0958 - 3 work.

7.3 Inspect the ship's shaft seal closed loop system.

Inspect the external piping, fittings, and pipe hangers exterior of the hull aft of shaft alley Frame 85 to the stern tube.

7.4 Contractor will inspect all welds, check for cracks in

all piping sections.

7.5 Inspect the Stern Tube Aft Seal Adapter Plate exterior

of ship at stern tube for any damage to welds.

7.6 Report material condition of ship's Stern Tube System

for leaks and overall material condition.

7.7 Inspect protective covering of the STFW system aft

seal supply piping external to the hull for damage.

7.8 Maintain workspaces in a clean condition during and

upon completion of the work requirements. Prevent contamination of any adjacent equipment and spaces.

7.9 Reports

7.9.1 Submit one (1) electronic copy in Portable

Document Format (PDF) and photographs.

8.0 GENERAL REQUIREMENTS:

8.1 Location: Tango Pier

8.2 POP: 22 – 24 Feb 2025

8.3 POC: Ed Madrelino edwin.s.madrelino.civ@us.navy.mil

Tel: (671)339-6040/(671)480-8085 mailto:edwin.s.madrelino.civ@us.navy.mil

1.0 ABSTRACT
The purpose of this item is to inspect the ship’s shaft seal closed loop system.
2.0 REFERENCES/ENCLOSURES
2.1 Available onboard
3.0 ITEM LOCATION/DESCRIPTION
3.1 Location/Quantity
3.1.1 Location: Underwater Hull
4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICE: None
5.0 NOTES
5.1 The contractor and all subcontractors, regardless of tier must consult the General Technical Requirements (GTR) to determine applicability to this work item. In performance of this work item, the contractor and all subcontractors regardless of tie...
5.2 The contractor and all subcontractors regardless of tier are advised to review other work items under this contract, Many of the definitions relating to performance of this work item are found in Work Item 001.
5.3 THIS SHIP CONTAINS HIGH VOLTAGE (HV) ELECTRICAL SYSTEMS. OBEY ALL POSTED AND VERBAL INSTRUCTIONS REGARDING SAFETY AND EXCLUSION FROM HIGH VOLTAGE AREAS. AT NO TIME APPROACH, WORK ON, OR ENTER A HIGH VOLTAGE AREA WITHOUT PROPER AUTHORIZATION.
5.4 THE T-AKE CLASS ELECTRICAL COLOR CODING DOES NOT FOLLOW CONSISTENT COLOR SCHEME. THE SHIP IS KNOWN TO HAVE CURRENT CARRYING CONDUCTORS COLORED GREEN, BLUE, BLACK, AND WHITE. ASSUME ALL ELECTRICAL CABLES ARE ENERGIZED UNTIL TESTED AND PROVEN OTHERW...
6.0 QUALITY ASSURANCE REQUIREMENTS: None additional
7.0 STATEMENT OF WORK REQUIRED
7.1 Coordinate with ship’s force to have associated equipment locked and/or tagged out per ship’s lock out/tag out policy. When the maintenance is complete, coordinate with ship’s force to have associated equipment unlocked and/or tagged in per ship’s...
7.2 Conduct a Pre-Dive Planning Meeting with the Diver’s Representative, Master, Chief Engineer and OMT REP. The meeting agenda and discussion covers, at a minimum:
7.2.1 Discuss means of communication between the Bridge, Dive Team, and Engine Room.
7.2.2 Discuss procedures/plans for emergencies.
7.2.3 Discuss the vessel’s anticipated drafts, pier-side clearance, and under-keel clearance at the time of the cleaning.
7.2.4 Discuss impact of the tides and currents on divers and the examination.
7.2.5 Discuss anticipated duration of the underwater work.
7.3 Inspect the ship's shaft seal closed loop system. Inspect the external piping, fittings, and pipe hangers exterior of the hull aft of shaft alley Frame 85 to the stern tube.
7.4 Contractor will inspect all welds, check for cracks in all piping sections.
7.5 Inspect the Stern Tube Aft Seal Adapter Plate exterior of ship at stern tube for any damage to welds.
7.6 Report material condition of ship's Stern Tube System for leaks and overall material condition.
7.7 Inspect protective covering of the STFW system aft seal supply piping external to the hull for damage.
7.8 Maintain workspaces in a clean condition during and upon completion of the work requirements. Prevent contamination of any adjacent equipment and spaces.
7.9 Reports
7.9.1 Submit one (1) electronic copy in Portable Document Format (PDF) and photographs.
8.0 GENERAL REQUIREMENTS:
8.1 Location: Tango Pier
8.2 POP: 22 – 24 Feb 2025
8.3 POC: Ed Madrelino edwin.s.madrelino.civ@us.navy.mil