08 1113_Hollow Metal Doors and Frames.pdf

PDF 79 KB Posted

Attached to
511/21103. CAK; Camp Grayling - Components Cleaning Bldg.
Solicitation number
RFQ - 171 - 230000000810
Issued by
Crawford County, Michigan

About this file

This document is a solicitation for a state and local contract opportunity in Michigan for the Camp Grayling - Components Cleaning Building Project #260272, Index #511/21103.CAK. The scope of work includes the provision of non-fire-rated and fire-rated hollow metal doors and frames, thermally insulated hollow metal doors with frames, and hollow metal borrowed lites glazing frames, as well as related accessories such as glazing, louvers, and matching panels. The project is located in Crawford County, Michigan. Bid attachments must be uploaded to the SIGMA VSS system, and questions should be emailed to the designated point of contact, Tim Miller, at tmiller@sidockgroup.com. The bid submission deadline is 2:00 p.m., and emailed proposals may be accepted on a case-by-case basis with prior approval. No additional details are provided regarding pricing terms, set-asides, incumbents, funding, or other salient information.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Mates Components Cleaning Building Project #260272, Index #511/21103.CAK

08 1113 - 1 HOLLOW METAL DOORS and

FRAMES

SECTION 08 1113

HOLLOW METAL DOORS AND FRAMES

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Non-fire-rated hollow metal doors and frames.

B. Fire-rated hollow metal doors and frames.

C. Thermally insulated hollow metal doors with frames.

D. Hollow metal borrowed lites glazing frames.

E. Accessories, including glazing, louvers, and matching panels.

1.02 RELATED REQUIREMENTS

A. Section 08 7100 - Door Hardware.

B. Section 09 9113 - Exterior Painting: Field painting.

C. Section 09 9123 - Interior Painting: Field painting.

D. Section 08 8000 - Glazing

1.03 REFERENCE STANDARDS

A. ADA Standards - Americans with Disabilities Act (ADA) Standards for Accessible Design 2010.

B. ANSI/SDI A250.4 - Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames and Frame Anchors 2011.

C. ANSI/SDI A250.8 - Specifications for Standard Steel Doors and Frames (SDI-100) 2017.

D. ANSI/SDI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and Frames 2011.

E. ASTM A653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process 2019a.

F. ASTM A1008 - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High- Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable 2018.

G. ASTM A1011 - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength 2018a.

H. ASTM E119 – Standard Test Methods for Fire Tests of Building Construction and Materials.

I. ICC A117.1 - Accessible and Usable Buildings and Facilities 2017.

J. ITS (DIR) - Directory of Listed Products current edition.

K. NAAMM HMMA 840 - Guide Specifications For Receipt, Storage and Installation of Hollow Metal Doors and Frames 2007.

L. NAAMM HMMA 861 - Guide Specifications for Commercial Hollow Metal Doors and Frames 2014.

M. NFPA 80 - Standard for Fire Doors and Other Opening Protectives 2019.

N. NFPA 105 – Standard for Smoke Door Assemblies and Other Opening Protectives 2022.

O. NFPA 252 - Standard Methods of Fire Tests of Door Assemblies 2017.

P. NFPA 257 – Standard on Fire Test for Window and Glass Block Assemblies 2022.

Q. SDI 117 - Manufacturing Tolerances for Standard Steel Doors and Frames 2013.

R. UL (DIR) - Online Certifications Directory Current Edition.

S. UL 9 – Standard for Safety Fire Tests of Window Assemblies 2009.

08 1113 - 2 HOLLOW METAL DOORS and

FRAMES

T. UL 10C - Standard for Positive Pressure Fire Tests of Door Assemblies 2016, Including All Revisions.

U. UL 263 – Standard for Safety of Fire Tests of Building Construction Materials.

V. UL 1784 – Standard for Air Leakage Tests of Door Assemblies and Other Opening Protectives 2015.

1.04 SUBMITTALS

A. See Section 01 3000 - Administrative Requirements, for submittal procedures.

B. Product Data: Materials and details of design and construction, hardware locations, reinforcement type and locations, anchorage and fastening methods, and finishes; and one copy of referenced standards/guidelines.

C. Shop Drawings: Details of each opening, showing elevations, glazing, frame profiles, and any indicated finish requirements.

1.05 DELIVERY, STORAGE, AND HANDLING

A. Comply with NAAMM HMMA 840 or ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.

B. Protect with resilient packaging; avoid humidity build-up under coverings; prevent corrosion and adverse effects on factory applied painted finish.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Hollow Metal Doors and Frames:

1. Ceco Door, an Assa Abloy Group: www.assaabloydss.com.

2. Curries, an Assa Abloy Group: www.assaabloydss.com.

3. Fleming Door Products, an Assa Abloy Group: www.assaabloydss.com.

4. Republic Doors, an Allegion brand: www.republicdoor.com.

5. Steelcraft, an Allegion brand: www.allegion.com.

6. Technical Glass Products; SteelBuilt Window & Door Systems: www.tgpamerica.com.

7. Substitutions: See Section 01 6000 - Product Requirements.

2.02 PERFORMANCE REQUIREMENTS

A. Requirements for Hollow Metal Doors and Frames:

1. Steel Sheet: Comply with one or more of the following requirements; galvannealed steel complying with ASTM A653, cold-rolled steel complying with ASTM A1008, or hot-rolled pickled and oiled (HRPO) steel complying with ASTM A101, commercial steel (CS) Type B, for each.

2. Accessibility: Comply with ICC A117.1 and ADA Standards.

3. Door Top Closures: Flush end closure channel, with top and door faces aligned.

4. Door Edge Profile: Manufacturers standard for application indicated.

5. Typical Door Face Sheets: Flush.

6. Glazed Lights: Non-removable stops on non-secure side; sizes and configurations as indicated on drawings. Style: Manufacturers standard.

7. Zinc Coating for Typical Interior and/or Exterior Locations: Provide metal components zinc-coated (galvanized) and/or zinc-iron alloy-coated (galvannealed) by the hot-dip process in accordance with ASTM A653, with manufacturer's standard coating thickness, unless noted otherwise for specific hollow metal doors and frames.

B. Combined Requirements: If a particular door and frame unit is indicated to comply with more than one type of requirement, comply with the specified requirements for each type; for instance, an exterior door that is also indicated as being sound-rated must comply with the requirements specified for exterior doors and for sound-rated doors; where two requirements conflict, comply with the most stringent.

2.03 HOLLOW METAL DOORS

A. Door Finish: Factory primed and field finished.

08 1113 - 3 HOLLOW METAL DOORS and

FRAMES

B. Type 1, Exterior Doors: Thermally insulated.

1. Based on SDI Standards: ANSI/SDI A250.8 (SDI-100).

a. Level 2 - Heavy-duty.

b. Physical Performance Level B, 500 000 cycles; in accordance with ANSI/SDI A250.4.

c. Model 1 - Full Flush.

d. Door Face Metal Thickness: 16 gage, 0.053 inch, minimum.

e. Zinc Coating: A60 galvannealed coating; ASTM A653.

2. Door Core Material: Manufacturers standard core material/construction and in compliance with requirements.

3. Door Thickness: 1-3/4 inch, nominal.

4. Door Face Sheets: Flush.

5. Weatherstripping: Refer to Section 08 7100.

C. Type 2 , Interior Doors, Non-Fire-Rated:

1. Based on SDI Standards: ANSI/SDI A250.8 (SDI-100).

a. Level 2 - Heavy-duty.

b. Physical Performance Level C, 250,000 cycles; in accordance with ANSI/SDI A250.4.

c. Model 1 - Full Flush.

d. Door Face Metal Thickness: 16 gage, 0.053 inch, minimum.

e. Zinc Coating: A60 galvannealed coating; ASTM A653.

2. Door Core Material: Manufacturers standard core material/construction and in compliance with requirements.

3. Door Thickness: 1-3/4 inch, nominal.

4. Door Face Sheets: Flush.

D. Type 3 ,Fire-Rated Doors:

1. Based on SDI Standards: ANSI/SDI A250.8 (SDI-100).

a. Level 2 - Heavy-duty.

b. Physical Performance Level B, 500 000 cycles; in accordance with ANSI/SDI A250.4.

c. Model 1 - Full Flush.

d. Door Face Metal Thickness: 16 gage, 0.053 inch, minimum.

e. Zinc Coating: A60 galvannealed coating; ASTM A653.

2. Fire Rating: As indicated on Door Schedule, tested in accordance with UL 10C and NFPA 252 ("positive pressure fire tests").

3. Provide units listed and labeled by UL (DIR).

a. Attach fire rating label to each fire rated unit.

4. Door Core Material: Manufacturers standard core material/construction in compliance with requirements.

5. Door Thickness: 1-3/4 inch, nominal.

6. Door Face Sheets: Flush.

2.04 HOLLOW METAL FRAMES

A. Comply with standards and/or custom guidelines as indicated for corresponding door in accordance with applicable door frame requirements.

B. Frame Finish: Factory primed and field finished.

C. Exterior Door Frames: Full profile/continuously welded type.

1. Galvanizing: Components hot-dipped zinc-iron alloy-coated (galvannealed) in accordance with ASTM A653, with A60 coating.

2. Frame Metal Thickness: 16 gage, 0.053 inch, minimum.

3. Weatherstripping: Separate, see Section 08 7100.

D. Interior Door Frames, Non-Fire Rated: Full profile/continuously welded type.

1. Frame Metal Thickness: 16 gage, 0.053 inch minimum.

E. Door Frames, Fire-Rated: Full profile/continuously welded type.

1. Fire Rating: Same as door, labeled.

2. Frame Metal Thickness: 16 gage, 0.053 inch, minimum.

F. Mullions for Pairs of Doors: Fixed, with profile similar to jambs.

08 1113 - 4 HOLLOW METAL DOORS and

FRAMES

G. Provide mortar guard boxes for hardware cut-outs in frames to be installed in masonry or to be grouted.

H. Frames in Masonry Walls: Size to suit masonry coursing with head member 4 inch high to fill opening without cutting masonry units.

I. Frames Wider Than 48 inches: Reinforce with steel channel fitted tightly into frame head, flush with top.

2.05 FINISHES

A. Primer: Rust-inhibiting, complying with ANSI/SDI A250.10, door manufacturer's standard.

B. Factory Finish: Complying with ANSI/SDI A250.3, manufacturer's standard coating.

1. Color:

2.06 ACCESSORIES

A. Louvers: Roll formed steel with overlapping frame; finish same as door components; factory-installed.

1. In Fire-Rated Doors: UL (DIR) or ITS (DIR) listed fusible link louver, same rating as door.

2. Style: Standard straight slat blade.

B. Door Window Frames: Door window frames with glazing securely fastened within door opening.

1. Size: As indicated on drawings.

2. Frame Material: 18 gage, 0.0478 inch, galvanized steel.

3. Metal Finish: Match door finish.

4. Glazing: 1/4 inch thick, tempered glass, in compliance with requirements of authorities having jurisdiction.

C. Glazing: insulated, laminated safety glazing, factory installed. Refer to Section 08 8000 for additional information.

D. Removable Stops: Formed sheet steel, shape as indicated on drawings, mitered or butted corners; prepared for countersink style tamper proof screws.

E. Astragals and Edges for Double Doors: Pairs of door astragals, and door edge sealing and protection devices.

1. UL listed products in compliance with requirements of authorities having jurisdiction.

2. Provide surface mounted astragal to cover or fill space for full door height between pair of doors or door and adjacent jamb.

F. Grout for Frames: Portland cement grout with maximum 4 inch slump for hand troweling;

thinner pumpable grout is prohibited.

G. Silencers: Resilient rubber, fitted into drilled hole; provide three on strike side of single door, three on center mullion of pairs, and two on head of pairs without center mullions.

H. Temporary Frame Spreaders: Provide for factory- or shop-assembled frames.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify existing conditions before starting work.

B. Verify that opening sizes and tolerances are acceptable.

C. Verify that finished walls are in plane to ensure proper door alignment.

3.02 PREPARATION

A. Coat inside of frames to be installed in masonry or to be grouted, with bituminous coating, prior to installation.

3.03 INSTALLATION

A. Install doors and frames in accordance with manufacturer's instructions and related requirements of specified door and frame standards or custom guidelines indicated.

08 1113 - 5 HOLLOW METAL DOORS and

FRAMES

B. Install fire rated units in accordance with NFPA 80.

C. Coordinate frame anchor placement with wall construction. All anchors to be concealed.

D. Comply with glazing installation requirements of Section 08 8000.

E. Install door hardware as specified in Section 08 7100.

F. Coordinate installation of electrical connections to electrical hardware items.

G. Touch up damaged factory finishes.

H. Door Bottom Fit:

1. 3/4 inch where no threshold or carpet.

2. 1/8 inch with threshold or carpet.

3.04 TOLERANCES

A. Clearances Between Door and Frame: Comply with related requirements of specified frame standards or custom guidelines indicated in accordance with SDI 117 or NAAMM HMMA 861.

B. Maximum Diagonal Distortion: 1/16 inch measured with straight edge, corner to corner.

3.05 ADJUSTING

A. Adjust for smooth and balanced door movement.

3.06 SCHEDULE

A. Refer to Door and Frame Schedule on the drawings.

END OF SECTION

File details come from the government source that posted it. Updated .