Sol. 70Z08518PR4526700 Amendment 0005 page of 2
Question 10 regarding D-15 Aircraft Securing Fittings para. 3.8
QUESTION: The KTR is directed by specification paragraph 3.8 to relocate/modify only the 6 specific equipment assemblies that are listed in sub-paragraphs 3.8.1 through 3.8.6. This instruction does not include the 400 Hz rectifier contained in drawing 588-504.
Is the KTR required to relocate this equipment along with those in 3.8.1 through 3.8.6?
Answer to Q #10: Equipment shall be moved as per specification Work Item and IAW drawing 588-504.