0305-05 - Chamber Retrofit - Drawings.pdf
PDF 255 KB Posted
- Attached to
- Chamber Retrofit Federal contract opportunity
- Solicitation number
- N0017824Q6400
About this file
This document is a combined synopsis/solicitation for a chamber retrofit contract opportunity issued by the Naval Sea Systems Command (NAVSEA). The requirement is to upgrade current capabilities by procuring dry air purge systems to be retrofitted to existing Thermotron environmental test chambers. Thermotron Industries, located in Holland, MI, is the sole source provider for the required proprietary hardware and supporting services.
The solicitation is issued as a Request for Quotation (RFQ) with a closing date of June 26, 2024 and an anticipated award by June 28, 2024. This is a firm fixed-price contract to be awarded on a lowest price technically acceptable basis. The government estimates the total contract value at over $92,000. Offerors must be registered in the System for Award Management (SAM) to be eligible. Historical pricing and capability statements are requested to be submitted with offers.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 0305-05 - Chamber Retrofit - SOW.pdf | ||
| 0305-05 - Chamber Retrofit - CDRL A001 Signed_Redacted.pdf | ||
| SF1449 N0017824Q6400 Draft.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
102.88
484.00
3X76.88
HIGH
DOOR
58.00 58.00 58.00
6X 6.00 PORT
8.00
8.00 3X59.88
78.13 78.13 78.13 43.00 85.88 79.88
5.50IN
DEEP PIT
CHAMBERS
CHAMBER
A
CHAMBER
B
CHAMBER
C
CONTROL
STATION
SIDE DOOR
A DOOR
B
DOOR
C
DOOR
BLOWERS
AB
PARTITION
DOOR
CONDITIONERS
76.88
56.00 116.00
91.00
A A
B B
9462 TRIPLE
CHAMBER
DO NOT SCALE DRAWING SHEET 1 OF 4
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:80 WEIGHT:
REVDWG. NO.
B
SIZE
TITLE:
NAME DATE
COMMENTS:
REFER TO "CHAMBER MODELS.DOCX"
FOR NOTES ON MODEL AND DRAWING.
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ONNEXT ASSY
PROPRIETARY AND CONFIDENTIAL
77.00
58.00
108.38
103.00
A
A
BB
85.87 98.00
80.75
77.00
108.00 59.88
91.00
SECTION A-A
154.50
80.75 70.00
142.00
78.13
59.88
SECTION B-B
58.00
77.00
59.88
91.00
FLOOR OF B9462 AND PIT
HIDDEN FOR INDIVIDUAL
CHAMBER DRAWINGS.
TOTAL INTERNAL DIMENSIONS
L: 154.50 " W: 108.00 " H: 98.00 "
USABLE INTERNAL SPACE
L: 154.50 " W: 80.75 " H: 85.87 "
USABLE INTERNAL SPACE IS
DEFINED AS LARGEST SPACE
WITHIN CHAMBER WITHOUT
INTERFERING WITH CHAMBER
COMPONENTS INCLUDING
PLENUM AND BLOWER.
A A
B B
9462 TRIPLE
CHAMBER
DO NOT SCALE DRAWING SHEET 2 OF 4
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:60 WEIGHT:
REV
B
SIZE
TITLE:
NAME DATE
COMMENTS:
REFER TO "CHAMBER MODELS.DOCX"
FOR NOTES ON MODEL AND DRAWING.
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ONNEXT ASSY
CHAMBER A
58.00 161.00
108.38
103.00
CC
D
D
60.00
78.00 91.00
59.88
59.88
78.13
80.75
155.00
108.00
SECTION C-C
80.75 108.00
85.87
78.00
60.00
59.88
88.00 98.00
SECTION D-D
FLOOR OF B9462 AND PIT
HIDDEN FOR INDIVIDUAL
CHAMBER DRAWINGS.
TOTAL INTERNAL DIMENSIONS
L: 155.00 " W: 108.00 " H: 98.00 "
USABLE INTERNAL SPACE
L: 155.00 " W: 80.75 " H: 85.87 "
USABLE INTERNAL SPACE IS
DEFINED AS LARGEST SPACE
WITHIN CHAMBER WITHOUT
INTERFERING WITH CHAMBER
COMPONENTS INCLUDING
PLENUM AND BLOWER.
A A
B B
9462 TRIPLE
CHAMBER
DO NOT SCALE DRAWING SHEET 3 OF 4
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:60 WEIGHT:
REV
B
SIZE
TITLE:
NAME DATE
COMMENTS:
REFER TO "CHAMBER MODELS.DOCX"
FOR NOTES ON MODEL AND DRAWING.
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ONNEXT ASSY
CHAMBER B
161.50
103.00
58.00 F
F
EE
91.00
59.88
108.00 80.75
85.87
59.88
98.00
SECTION F-F
154.50
108.00 80.75
SECTION E-E
FLOOR OF B9462 AND PIT
HIDDEN FOR INDIVIDUAL
CHAMBER DRAWINGS.
TOTAL INTERNAL DIMENSIONS
L: 155.00 " W: 108.00 " H: 98.00 "
USABLE INTERNAL SPACE
L: 155.00 " W: 80.75 " H: 85.87 "
USABLE INTERNAL SPACE IS
DEFINED AS LARGEST SPACE
WITHIN CHAMBER WITHOUT
INTERFERING WITH CHAMBER
COMPONENTS INCLUDING
PLENUM AND BLOWER.
A A
B B
9462 TRIPLE
CHAMBER
DO NOT SCALE DRAWING SHEET 4 OF 4
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:60 WEIGHT:
REV
B
SIZE
TITLE:
NAME DATE
COMMENTS:
REFER TO "CHAMBER MODELS.DOCX"
FOR NOTES ON MODEL AND DRAWING.
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ONNEXT ASSY
CHAMBER C
| OUTSIDE |
| Drawing View1 |
| Drawing View2 |
| Drawing View4 |
| Drawing View5 |
| CHAMBER A |
| Drawing View6 |
| Section View A-A |
| Section View B-B |
| Drawing View12 |
| CHAMBER B |
| Drawing View13 |
| Drawing View16 |
| Section View C-C |
| Section View D-D |
| CHAMBER C |
| Drawing View19 |
| Drawing View22 |
| Section View F-F |
| Section View E-E |
File details come from the government source that posted it. Updated .