AREASFINISH

FLOOR PLAN

OF WORK

2 2

NOTES:

GENERAL NOTES

1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. ALL

DIMENSIONS AND CONDITIONS ARE TO BE VERIFIED IN FIELD BY

THE CONTRACTOR.

2. CONTRACTOR SHALL PHASE INSTALLATION OF EPOXY FLOOR. IN

ADVANCE OF INSTALLATION, CONTRACTOR SHALL COORDINATE

WITH USG FOR THE TEMPORARY RELOCATION OF ITEMS AND

EQUIPMENT HELD IN AREAS OF WORK.

A-602

HANGAR 7 - FINISH FLOOR PLAN

SCALE: 3/32" = 1'-0"

A-102

KEY NOTES

A. FLOOR MOUNTED EQUIPMENT TO REMAIN IN PLACE THROUGHOUT

DURATION OF WORK. CONTRACTOR SHALL PROTECT EQUIPMENT

AND INSTALL EPOXY FLOOR SYSTEM UP TO EQUIPMENT (TYP)

B. APPROXIMATE LOCATION OF 5" WIDE NOMINAL SAFETY YELLOW

EPOXY STRIP.

C. SEAMLESS EPOXY COVE BASE

D. RESILIENT BASE

E. NO BASE MOLDING

KEY NOTES (CONTINUED)

F. RELOCATE EQUIPMENT AND REINSTALL FOLLOWING INSTALLATION

AND CURING OF EPOXY FLOOR.

G. THIS AREA NOT IN CONTRACT..

B126 & H7

EPOXY FLOOR

G

G

G

G

G

E

TYP

E

TYP

E

TYP

AutoCAD SHX Text 31,515 S.F.

AutoCAD SHX Text

780 SF

AutoCAD SHX Text

EPOXY FLR

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text 127th WING/CIVIL ENGINEER

AutoCAD SHX Text Engineer/Consultants

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text

SELFRIDGE AIR

AutoCAD SHX Text

NATIONAL GUARD

AutoCAD SHX Text

BASE, MICHIGAN

AutoCAD SHX Text

REVISIONS:

AutoCAD SHX Text Project Number:

AutoCAD SHX Text File:

AutoCAD SHX Text Drawn By:

AutoCAD SHX Text Designed By:

AutoCAD SHX Text Checked By:

AutoCAD SHX Text A. Vermeersch

AutoCAD SHX Text A. Vermeersch

AutoCAD SHX Text

AutoCAD SHX Text Mark

AutoCAD SHX Text Date

AutoCAD SHX Text Description

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text Scale:

AutoCAD SHX Text Date:

AutoCAD SHX Text

15 APR 2020

AutoCAD SHX Text

1. THE PLAN AND UNDERGROUND THE PLAN AND UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE GOVERNMENT MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN-SERVICE OR ABANDONED. THE GOVERNMENT FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION.

AutoCAD SHX Text NOTE: FOR INFORMATION PURPOSES ONLY. NOT FOR DESIGN OR CONSTRUCTION. FIELD VERIFY DIMENSIONS PRIOR TO DESIGN AND PRIOR TO CONSTRUCTION.

AutoCAD SHX Text A. Vermeersch

AutoCAD SHX Text

VGLZ202023

AutoCAD SHX Text 3/32" = 1'-0"

Sheets and Views
H7 - Areas of work

File details come from the government source that posted it. Updated .