About this file

This document contains construction drawings and specifications for a building exterior elevation project. The project involves precast concrete cladding, insulated laminated vision exterior materials, wire mesh fencing, and infill of existing windows with CMU block at the Saint Louis Veterans Hospital located in New Orleans, Louisiana. The drawings provide elevations, sections, and details for the building exterior and identify materials, connectors, and references related to precast concrete cladding. Relevant project information includes the building number, location, drawing title, dates, revisions, agencies involved, and the solicitation number for suicide risk mitigation for parking garages.

View the file

Other files

File Type Posted
Review Screen Example - Image DOC-001.pdf PDF
Review Fence Example - Image DOC-001.pdf PDF
General Decision LA 20200041 10-09-2020.pdf PDF
0250-5AS205.pdf PDF
VA Master Specs Table of Contents.docx DOCX document
0246-5AS201.pdf PDF
36C25621R0029_1.docx DOCX document
0223-4AS205.pdf PDF
ANNOTATED 3D DIM - VISITOR GARAGE 001.pdf PDF
0222-4AS204.pdf PDF
0220-4AS202.pdf PDF
0247-5AS202.pdf PDF
0251-5AS206.pdf PDF
EXHIBIT A CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY.pdf PDF
0219-4AS201.pdf PDF
ANNOTATED 3D DIM - VISITOR GARAGE 002.pdf PDF
0248-5AS203.pdf PDF
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSULATED LAMINATED VISION

EXTERIOR MATERIALS LEGEND

GLASS TYPES

COLOR: CLEAR

PRECAST

PC-3 - SEE STRUCTURAL DRAWINGS

METALS

WWF FENCE

WIRE MESH

04-L1 100' - 0"

04-L2 114' - 8"

04-L3 127' - 4"

04-L4 138' - 0"

04-L5 148' - 8"

04-L6 159' - 4"

04-L7 170' - 0"

04-L8 180' - 0"

'-8

'-8

'-8

'-8

'-8

'-8

'-0

1.4

3.6

CONNECTOR IS FUTURE

WORK PACKAGE

0AS505

E2

D2

0AS601

E2

0AS601

PLEASE REFER TO SUBMITTAL 03 41 33 -

007 FOR INFORMATION ON PRECAST

CONCRETE CLADDING AT STAIR TOWERS

K

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

4AS203

BLDG 4 EXTERIOR ELEVATON EAST

DV MAGJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_04

SCALE: 1/8" = 1'-0"1 BLDG 4 EAST ELEVATION

2 ADDENDUM #2 JULY 29, 2011

4 ADDENDUM #4 AUGUST 5, 2011

6 ADDENDUM #6 - POST BID JANUARY 27, 2012

10 BULLETIN 011D MAY 31, 2013

Pre-Bid RFI-04-050 - Cladding at STK-1 Tower is Perforated Metal Panel.

RFI-04887: Infill windows with 6" CMU block set back 1" from inside face of precast

File details come from the government source that posted it. Updated .