02.0 Attachment 02 - Price Schedule of Hazardous Waste Services for Barstow_062121.xlsx
XLSX spreadsheet 130 KB Posted
- Solicitation number
- SP450022R0002
- Issued by
-
Defense Logistics Agency
About this file
This price schedule attachment outlines pricing for hazardous waste services for a base contract at Barstow, California. The contractor shall provide rental and transportation services for roll-off boxes, vacuum boxes, and frac tanks of various sizes on a daily, weekly, and monthly basis. Additional services include sampling and analysis, industrial cleaning crews, overpacking, lab packing of chemicals, and recycling of antifreeze and used oil. Pricing is to be provided for over 100 different service line items to support the removal, transportation, and disposal of hazardous, non-hazardous, universal, and other regulated wastes from military installations within 50 miles of Barstow over a 30 month period.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Base Leach Master HW Disposal Contract - IGE Barstow/China Lake Price Schedule - Base (30 Months)
| Base | ||||||
| CLIN | Description | CLIN | Est. Qty (30 Months) | U/I | Price | Extended Cost |
| SERVICE CLINs | ||||||
| 1001SA | Perform sampling and analysis to determine Waste Characteristics (D001-D0043) using current SW-846 Methods. Provide Hazardous Waste Profile Sheet (HWPS) (See 3.26). | 1001SA | 25 | EA | $ - 0 | |
| 1020RE | Daily Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2). | 1020RE | 20 | EA | $ - 0 | |
| 1021RE | Weekly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3). | 1021RE | 50 | EA | $ - 0 | |
| 1022RE | Monthly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4). | 1022RE | 50 | EA | $ - 0 | |
| 1030RE | Daily Rental of a 30-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2). | 1030RE | 20 | EA | $ - 0 | |
| 1031RE | Weekly Rental of a 30-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3). | 1031RE | 20 | EA | $ - 0 | |
| 1032RE | Monthly Rental of a 30-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4). | 1032RE | 20 | EA | $ - 0 | |
| 1040RE | Daily Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2). | 1040RE | 10 | EA | $ - 0 | |
| 1041RE | Weekly Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3). | 1041RE | 15 | EA | $ - 0 | |
| 1042RE | Monthly Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4). | 1042RE | 15 | EA | $ - 0 | |
| 1060RE | Daily Rental of a 20- or 25-yd3 Vacuum Box (See 3.6). | 1060RE | 1 | EA | $ - 0 | |
| 1061RE | Weekly Rental of a 20- or 25-yd3 Vacuum Box (See 3.7). | 1061RE | 1 | EA | $ - 0 | |
| 1071RE | Weekly Rental of a FRAC Tank with Containment (See 3.8). | 1071RE | 10 | EA | $ - 0 | |
| 1072RE | Monthly Rental of a FRAC Tank with Containment (See 3.9). | 1072RE | 10 | EA | $ - 0 | |
| 1095SV | 1-Business Day Expedited Service/Performance | |||||
| (See 1.2.11). | 1095SV | 12 | EA | $ - 0 | ||
| 1096SV | 3-Business Day Expedited Service/Performance | |||||
| (See 1.2.11). | 1096SV | 36 | EA | $ - 0 | ||
| 1097SV | 5-Business Day Expedited Service/Performance | |||||
| (See 1.2.11). | 1097SV | 21 | EA | $ - 0 | ||
| 1098SV | 10-Business Day Expedited Service/Performance | |||||
| (See 1.2.11). | 1098SV | 46 | EA | $ - 0 | ||
| 1200RE | Initial Placement or Removal of Empty Rented Rolloff Box or Vacuum Box (See 3.10). | 1200RE | 40 | EA | $ - 0 | |
| 1002SV | Industrial Cleaning Services, Daily, Crew of Two (2) (See 3.11). | 1002SV | 5 | EA | $ - 0 | |
| 1003SV | Industrial Cleaning Services, Weekly, Crew of Two (2) (See 3.12). | 1003SV | 5 | EA | $ - 0 | |
| 1007SV | Industrial Cleaning Services, Daily, Crew of Three (3) (See 3.14). | 1007SV | 5 | EA | $ - 0 | |
| 1008SV | Industrial Cleaning Services, Weekly, Crew of Three (3) (See 3.15). | 1008SV | 5 | EA | $ - 0 | |
| 1080SV | Surcharge for Weekend Work, Daily, Crew of Two (2) (See 3.17). | 1080SV | 5 | EA | $ - 0 | |
| 1081SV | Surcharge for Weekend Work, Daily, Crew of Three (3) (See 3.18). | 1081SV | 5 | EA | $ - 0 | |
| 1082SV | Surcharge for Hydro/Water Blasting Work, Daily, Crew of Three (3) (See 3.19). | 1082SV | 5 | EA | $ - 0 | |
| 1083SV | Surcharge for Permit-Required Confined Space Work, Daily, Crew of Three (3) (See 3.20). | 1083SV | 3 | EA | $ - 0 | |
| 1099SV | Surcharge for Expedited Commencement of ICS Work, Crew of Two-Three (2-3) (See 3.22). | 1099SV | 1 | EA | $ - 0 | |
| 1900 | Test for PFAS in Drinking Water, EPA Method 537.1, or update thereto. | 1900SA | 5 | EA | $ - 0 | |
| 1901SA | Test for PFAS in Non-Potable Water, EPA SW-846 Method 8327, or update thereto. | 1901SA | 10 | EA | $ - 0 | |
| 1902SA | Test for PFAS in Solids, Sludges, Liquid. USEPA Method SPE-ID, or update thereto. | 1902SA | 10 | EA | $ - 0 | |
| 1903SA | Test for Total Organic Fluoride (TOF), EPA Method for TOF, or update thereto. | 1903SA | 10 | EA | $ - 0 | |
| 6310 | Overpack for Compliance (85- to 110-GL container) (See 1.2.12). | 6310 | 10 | EA | $ - 0 | |
| 6311 | Overpack for Compliance (5-, 15-, 30-, or 55-GL container) (See 1.2.12). | 6311 | 5 | EA | $ - 0 | |
| 6311AA | Provide service to place waste in containers - up to one 5 gallon container (See 1.2.13 and 3.27). | 6311AA | 5 | EA | $ - 0 | |
| 6311BB | Provide service to place waste in containers - one container 6- to 15-gallon (See 1.2.13 and 3.27). | 6311BB | 5 | EA | $ - 0 | |
| 6311CC | Provide service to place waste in containers - one 16- to 30-gallon (See 1.2.13 and 3.27). | 6311CC | 5 | EA | $ - 0 | |
| 6311DD | Provide service to place waste in containers - one 31- to 55-gallon (See 1.2.13 and 3.27). | 6311DD | 5 | EA | $ - 0 | |
| 6320 | Provide and prepare lab packs, consisting of small quantity chemicals (56-85 gal) (See 3.27). | 6320 | 100 | EA | $ - 0 | |
| 6321 | Provide and prepare lab packs, consisting of small quantity chemicals (55 gal) (See 3.27). | 6321 | 100 | EA | $ - 0 | |
| 6322 | Provide and prepare lab packs, consisting of small quantity chemicals (20-30 gal) (See 3.27). | 6322 | 100 | EA | $ - 0 | |
| 6323 | Provide and prepare lab packs, consisting of small quantity chemicals (5-15 gal) (See 3.27). | 6323 | 100 | EA | $ - 0 | |
| 6324 | Provide and prepare lab packs, consisting of small quantity chemicals (<5 gal) (See 3.27). | 6324 | 5 | EA | $ - 0 | |
| 6350B1 | Tank Decommission Cleaning - Above Ground, ≤500 GL (See 3.34). | 6350B1 | 3 | EA | $ - 0 | |
| 6350B2 | Tank Decommission Cleaning - Below Ground, ≤500 GL (See 3.34). | 6350B2 | 3 | EA | $ - 0 | |
| 6350B3 | Tank Decommission Cleaning - Above Ground, 501 GL - 2500 GL (See 3.34). | 6350B3 | 3 | EA | $ - 0 | |
| 6350B4 | Tank Decommission Cleaning - Below Ground, 501 GL - 2500 GL (See 3.34). | 6350B4 | 3 | EA | $ - 0 | |
| 6350B5 | Tank Decommission Cleaning - Above Ground, 2,501 GL - 5,000 GL (See 3.34). | 6350B5 | 3 | EA | $ - 0 | |
| 6350B6 | Tank Decommission Cleaning - Below Ground, 2,501 GL - 5,000 GL (See 3.34). | 6350B6 | 3 | EA | $ - 0 | |
| 6350B7 | Tank Decommission Cleaning - Above Ground, 5,001 GL - 30,000 GL (See 3.34). | 6350B7 | 3 | EA | $ - 0 | |
| 6350B8 | Tank Decommission Cleaning - Below Ground, 5,001 GL - 30,000 GL (See 3.34). | 6350B8 | 3 | EA | $ - 0 | |
| 6350B9 | Tank Decommission Cleaning - Above Ground, 20,001 GL - 30,000 GL (See 3.34). | 6350B9 | 2 | EA | $ - 0 | |
| 6350BB | Tank Decommission Cleaning - Below Ground, 20,001 GL - 30,000 GL (See 3.34). | 6350BB | 2 | EA | $ - 0 | |
| 6396TD | Transportation Demurrage, Active Ranges (See 3.35). | 6396TD | 60 | EA | $ - 0 | |
| 6396TR | Transportation on Government Premises (3.18). | 6396TR | 30 | EA | $ - 0 | |
| 6400AA | Prepare Waste Profile Sheet/Form (See 3.25). | 6400AA | 25 | EA | $ - 0 | |
| 6401 | Perform hazardous waste characteristics analysis to determine ignitability (D001), corrosivity (D002), & reactivity (D003) (See 3.24). | 6401 | 25 | EA | $ - 0 | |
| 6402 | Perform TTLC Analysis - All Metals per 22 CCR (EPA 6010) | 6402 | 20 | EA | $ - 0 | |
| 6403 | Perform TCLP metals analysis to determine 8 RCRA metals (D004-D011) (See 3.24). | 6403 | 25 | EA | $ - 0 | |
| 6403BB | Perform STLC Analysis - All Metals 22 CCR WET. | 6403BB | 5 | EA | $ - 0 | |
| 6405 | Perform TCLP analyses to determine volatile and semivolatile organics (D018-D043) (See 3.24). | 6405 | 10 | EA | $ - 0 | |
| 6406 | Perform F-series solvent analyses to determine EPA waste codes F001-F005 (See 3.24). | 6406 | 5 | EA | $ - 0 | |
| 6409 | Perform TPH Analysis - C4-C44 By Range (EPA 8015B). | 6409 | 10 | EA | $ - 0 | |
| 6410 | Testing unknown compressed gas cylinders. | 6410 | 1 | EA | $ - 0 | |
| 6411 | Perform VOC Analysis Analysis (EPA 8260) (See 3.24). | 6411 | 15 | EA | $ - 0 | |
| 6417 | Perform SVOC Analysis (EPA 8270) (See 3.24). | 6417 | 10 | EA | $ - 0 | |
| 6421 | Perform test for asbestos (See 3.24). | 6421 | 21 | EA | $ - 0 | |
| 6422 | Perform analysis to determine benzene, toluene, ethylbenzene, and xylene (See 3.24). | 6422 | 5 | EA | $ - 0 | |
| 6423 | Perform to determine cresol. (See 3.24) | 6423 | 10 | EA | $ - 0 | |
| 6424 | Perform PCB Analysis (EPA 8082C) (See 3.24). | 6424 | 100 | EA | $ - 0 | |
| 6426 | Perform Dioxins and PCDFs Analysis (EPA 8280) (See 3.24). | 6426 | 2 | EA | $ - 0 | |
| 6427 | Perform Fuel Fingerprint of Product Analysis (EPA 8015B) (See 3.24). | 6427 | 10 | EA | $ - 0 | |
| 6425 | Perform Acute Bioassy Analysis - LC50 < 500 mg/L (22 CCR) (See 3.24). | 6425 | 5 | EA | $ - 0 | |
| 6430 | Provide Hazardous Categorization | |||||
| (HazCat) Identification Services (See 3.36). | 6430 | 50 | EA | $ - 0 | ||
| 6502A1 | Tank Cutting Services (3.34). | 6502A1 | 3 | EA | $ - 0 | |
| 6503 | Provide certificate of disposal (See 2.6). | 6503 | 5 | EA | $ - 0 | |
| 6601 | Evaluate unknown compressed gas cylinder (See 2.5.1). | 6601 | 10 | EA | $ - 0 | |
| 6608 | Perform appropriate sampling and analysis to properly identify the gas and complete the waste profile form (See 2.5.2). | 6608 | 10 | EA | $ - 0 | |
| 6610PA | Surcharge for Zone "A" Poison Gases (See 2.5.4). | 6610PA | 5 | EA | $ - 0 | |
| 6631 | Stabilization of MEKP and/or Peroxides (See 3.32). | 6631 | 5 | EA | $ - 0 | |
| PROFILE BASED CLINs | $ - 0 | |||||
| BA01 | Alkaline Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Various Permissible Waste Codes: UW, D002, D004-11.
| BA01C7 | 10,400 | LB | $ - 0 |
| BA02 | Calcium Chromate (CaCrO4) Thermal Batteries, Intact & Deactivated, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D001 (OX), D002-11. | BA02C7 | 250 | LB | $ - 0 |
| BA03 | Carbon-Zinc (CZn) Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002, D004-11. | BA03C7 | 10 | LB | $ - 0 |
| BA04 | Lead Acid Batteries, Wet, Dry, or Gel Pack may be managed as UW/HW under 40 CFR Part 266, Subpart G or as Recycling/Recovery Only. |
Physical State: Various
| Permissible Waste Codes: UW, D002, D004-11. | BA04C7 | 9,950 | LB | $ - 0 |
| BA05 | Lithium Ion (Li-Ion) Batteries, for mandatory recycling. |
Physical State: Solid
| Permissible Waste Codes: UW, D002-11. | BA05C7 | 6,200 | LB | $ - 0 |
| BA06 | Lithium Iron Disulfide (Li2FeS2) Thermal Batteries, including fully discharged Lithium Alloy Thermal Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002-11. | BA06C7 | 50 | LB | $ - 0 |
| BA07 | Lithium Manganese (LiMn and Oxides thereof) Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002-11. | BA07C7 | 1,100 | LB | $ - 0 |
| BA08 | Lithium Sulfur Dioxide (LiSO2) Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002-11. | BA08C7 | 1,700 | LB | $ - 0 |
| BA09 | Lithium Thionyl Chloride (LiSCl) Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002-11. | BA09C7 | 150 | LB | $ - 0 |
| BA10 | Lithium Batteries, Mixed Types, deactivated if applicable, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002-11. | BA10C7 | 4,700 | LB | $ - 0 |
| BA12 | Mercury (Hg) Batteries, for mandatory recycling. |
Physical State: Solid
| Permissible Waste Codes: UW, D002, D004-11. | BA12C7 | 50 | LB | $ - 0 |
| BA13 | Nickel Metal Hydride (NiMh) Batteries, Wet and Dry, for mandatory recycling. |
Physical State: Various
| Permissible Waste Codes: UW, D002, D004-11. | BA13C7 | 3,800 | LB | $ - 0 |
| BA14 | Nickel-Cadmium (NiCd) Batteries, Wet and Dry, for mandatory recycling. |
Physical State: Various
| Permissible Waste Codes: UW, D002, D004-11. | BA14C7 | 3,900 | LB | $ - 0 |
| BA15 | Silver-Zinc (AgZn) and Zinc Silver Oxide (ZnAgO) Batteries, for mandatory recycling. |
Physical State: Solid
| Permissible Waste Codes: UW, D002, D004-11. | BA15C7 | 50 | LB | $ - 0 |
| BA77 | Mixed Alkaline, Carbon-Zinc, Nickel-Metal-Hydride, & Titanium Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002. | BA77C7 | 2,500 | LB | $ - 0 |
| BA79 | Lithium Batteries, Mixed Types, including Lithium Aluminum Sulfide Thermal, deactivated if applicable, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002-11. | BA79C7 | 2,000 | LB | $ - 0 |
| BA97 | Alkaline Batteries, managed as Universal Waste (UW) for mandatory recycling. |
Physical State: Solid
| Permissible Waste Codes: UW. | BA97C7 | 10,000 | LB | $ - 0 |
| CS01 | Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm. |
Physical State: Liquid
| Permissible Waste Codes: D002, D004-11, Listed Inorganics. | CS01C1 | 23 | EA | $ - 0 | ||
| CS01C2 | 10 | EA | $ - 0 | |||
| CS01C3 | 6 | EA | $ - 0 | |||
| CS01C4 | 10 | EA | $ - 0 | |||
| CS01C5 | 1 | EA | $ - 0 | |||
| CS01B5 | 5,000 | GL | $ - 0 | |||
| CS02 | Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, >1% Total Metals, Cr+6 <100 ppm. |
Physical State: Liquid
| Permissible Waste Codes: D002, D004-11, Listed Inorganics. | CS02C1 | 10 | EA | $ - 0 | ||
| CS02C2 | 5 | EA | $ - 0 | |||
| CS02C3 | 3 | EA | $ - 0 | |||
| CS02C4 | 5 | EA | $ - 0 | |||
| CS02C5 | 1 | EA | $ - 0 | |||
| CS02B5 | 5,000 | GL | $ - 0 | |||
| CS03 | Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm. |
Physical State: Liquid
| Permissible Waste Codes: D002, D004-11, Listed Inorganics. | CS03C1 | 5 | EA | $ - 0 | ||
| CS03C2 | 5 | EA | $ - 0 | |||
| CS03C3 | 5 | EA | $ - 0 | |||
| CS03C4 | 5 | EA | $ - 0 | |||
| CS03C5 | 1 | EA | $ - 0 | |||
| CS04 | Corrosive Acids, Chromic (H2Cr04 ), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris. |
Physical State: Various
| Permissible Waste Codes: D001 (OX), D002, D004-11. | CS04C1 | 5 | EA | $ - 0 | ||
| CS04C2 | 5 | EA | $ - 0 | |||
| CS04C3 | 5 | EA | $ - 0 | |||
| CS04C4 | 13 | EA | $ - 0 | |||
| CS04C5 | 1 | EA | $ - 0 | |||
| CS07 | Corrosive Acids, Chromic (H2CrO4), >100 ppm Cr+6, Listed Liquids, Solids, Sludges, Debris. |
Physical State: Various
| Permissible Waste Codes: D001 (OX), D002, D004-11, F-Listed, U032. | CS07C1 | 5 | EA | $ - 0 | ||
| CS07C2 | 5 | EA | $ - 0 | |||
| CS07C3 | 5 | EA | $ - 0 | |||
| CS07C4 | 5 | EA | $ - 0 | |||
| CS07C5 | 1 | EA | $ - 0 | |||
| CS08 | Corrosive Acids, Non-Fuming, Hydrofluoric (HF) <40% and/or Nitric (HNO3), <25% in Water. |
Physical State: Liquid
| Permissible Waste Codes: D001 (OX), D002, D004-11, Listed Inorganics. | CS08C1 | 5 | EA | $ - 0 | ||
| CS08C2 | 5 | EA | $ - 0 | |||
| CS08C3 | 5 | EA | $ - 0 | |||
| CS08C4 | 5 | EA | $ - 0 | |||
| CS08C5 | 1 | EA | $ - 0 | |||
| CS09 | Corrosive Acids, Fuming, Hydrofluoric (HF) >40% and/or Nitric (HNO3), ≥25% in Water, may include Red Fuming Nitric Acid (RFNA). |
Physical State: Liquid
| Permissible Waste Codes: D001 (OX), D002, D004-11, Listed Inorganics. | CS09C1 | 5 | EA | $ - 0 | ||
| CS09C2 | 5 | EA | $ - 0 | |||
| CS09C3 | 5 | EA | $ - 0 | |||
| CS09C4 | 5 | EA | $ - 0 | |||
| CS09C5 | 1 | EA | $ - 0 | |||
| CS10 | Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines. |
Physical State: Liquid
| Permissible Waste Codes: D002, D004-11, Listed Inorganics. | CS10C1 | 10 | EA | $ - 0 | ||
| CS10C2 | 5 | EA | $ - 0 | |||
| CS10C3 | 5 | EA | $ - 0 | |||
| CS10C4 | 5 | EA | $ - 0 | |||
| CS10C5 | 2 | EA | $ - 0 | |||
| CS10B5 | 10,000 | GL | $ - 0 | |||
| CS11 | Corrosive Alkalines, Inorganic, <50% in Water, >1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines. |
Physical State: Liquid
| Permissible Waste Codes: D002, D004-11, Listed Inorganics. | CS11C1 | 3 | EA | $ - 0 | ||
| CS11C2 | 3 | EA | $ - 0 | |||
| CS11C3 | 3 | EA | $ - 0 | |||
| CS11C4 | 3 | EA | $ - 0 | |||
| CS11C5 | 1 | EA | $ - 0 | |||
| CS12 | Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint ≥140◦F. |
Physical State: Various
| Permissible Waste Codes: D002, D004-43, Listed. | CS12C1 | 5 | EA | $ - 0 | ||
| CS12C2 | 5 | EA | $ - 0 | |||
| CS12C3 | 5 | EA | $ - 0 | |||
| CS12C4 | 5 | EA | $ - 0 | |||
| CS13 | Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Flashpoint ≥140◦F. |
Physical State: Various
| Permissible Waste Codes: D002, D004-43, Listed. | CS13C1 | 5 | EA | $ - 0 | ||
| CS13C2 | 5 | EA | $ - 0 | |||
| CS13C3 | 5 | EA | $ - 0 | |||
| CS13C4 | 25 | EA | $ - 0 | |||
| CS13C5 | 1 | EA | $ - 0 | |||
| CS14 | Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries. |
Physical State: Various
| Permissible Waste Codes: D002, D004-11, Listed. | CS14C1 | 25 | EA | $ - 0 | ||
| CS14C2 | 5 | EA | $ - 0 | |||
| CS14C3 | 25 | EA | $ - 0 | |||
| CS14C4 | 5 | EA | $ - 0 | |||
| CS15 | Corrosive Aerosols, Non-Ignitable and Non-Reactive, even when managed as UW. |
Physical State: Various
| Permissible Waste Codes: UW, D002, D004-11, Listed. | CS15C7 | 500 | LB | $ - 0 |
| CS99 | Military Items, Demil-required, Corrosive Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. CD Required. |
Physical State: Various
| Permissible Waste Codes: D002, D004-11, Listed. | CS99C4 | 5 | EA | $ - 0 | ||
| CS99C6 | 5 | EA | $ - 0 | |||
| CY01 | Category 1 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases. | CY01ME | 50 | EA | $ - 0 | ||
| CY01M1 | 205 | EA | $ - 0 | |||
| CY01M2 | 5 | EA | $ - 0 | |||
| CY01M3 | 5 | EA | $ - 0 | |||
| CY02 | Category 2 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases. | CY02ME | 370 | EA | $ - 0 | ||
| CY02M1 | 150 | EA | $ - 0 | |||
| CY02M2 | 30 | EA | $ - 0 | |||
| CY03 | Category 3 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases. | CY03ME | 2 | EA | $ - 0 | ||
| CY03M1 | 2 | EA | $ - 0 | |||
| CY03M2 | 2 | EA | $ - 0 | |||
| CY03M3 | 2 | EA | $ - 0 | |||
| CY05 | Category 5 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases. | CY05ME | 20 | EA | $ - 0 | ||
| CY05M1 | 15 | EA | $ - 0 | |||
| CY06 | Category 6 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases. | CY06M1 | 3 | EA | $ - 0 | ||
| CY06M2 | 3 | EA | $ - 0 | |||
| CY06M3 | 3 | EA | $ - 0 | |||
| CY07 | Category 7 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases. | CY07ME | 3 | EA | $ - 0 | ||
| CY07M1 | 3 | EA | $ - 0 | |||
| CY07M2 | 3 | EA | $ - 0 | |||
| CY08 | Category 8 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases. | CY08M2 | 50 | EA | $ - 0 |
| CY09 | Cylinders, Acetylene, Contains Asbestos, for Purge and Landfill. |
Physical State: Comp. Gas
| Permissible Waste Codes: D001. | CY09M1 | 30 | EA | $ - 0 |
| CY10 | Cylinders, Acetylene, No Asbestos, for Recycle/Reuse. |
Physical State: Comp. Gas
| Permissible Waste Codes: D001. | CY10M2 | 180 | EA | $ - 0 |
| CY11 | Cylinders, Propane, 20-Lb "Grill Size", for Disposal, Recycle, or Reuse. Typically 13" x 17". "ME" = 1 EA Grill-Size Cylinder. |
Physical State: Comp. Gas
| Permissible Waste Codes: D001. | CY11ME | 5 | EA | $ - 0 |
| CY12 | Cylinders, Flammable, AVGAS, Ether Gas/Diesel Starting, for Disposal or Recycle. Diameter up to 3", Length up to 12". "ME" = 1 EA Cylinder. |
Physical State: Comp. Gas
| Permissible Waste Codes: D001. | CY12ME | 500 | EA | $ - 0 |
| CY13 | Cartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6". "ME" = 1 EA Cartridge |
Physical State: Comp. Gas
| Permissible Waste Codes: N/A. | CY13ME | 35 | EA | $ - 0 |
| FL01 | Aerosols, Flammable/Combustible/Ignitable, Non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW. |
Physical State: Various Permissible Waste Codes: Universal Waste, D001 (IGN), D004-43, Listed.
| FL01C7 | 10,700 | LB | $ - 0 |
| FL02 | Flammable Debris contaminated with common solvents, shreddable, no free liquids, no large metal, rock, or masonry components. |
Physical State: Solid
| Permissible Waste Codes: D001, D004-43, Listed. | FL02C1 | 5 | EA | $ - 0 | ||
| FL02C2 | 5 | EA | $ - 0 | |||
| FL02C3 | 5 | EA | $ - 0 | |||
| FL02C4 | 70 | EA | $ - 0 | |||
| FL03 | Flammable Liquids/Solids/Sludges/Debris, e.g., tank sludge, lubricants, adhesives, miscellaneous debris, non-reactive paint waste with isocyanates, primarily consists of incinerable, non-fuels-blendable materials. Use LP03 for loose packs. |
Physical State: Various
| Permissible Waste Codes: D001-2, D004-43, Listed. | FL03C1 | 40 | EA | $ - 0 | ||
| FL03C2 | 10 | EA | $ - 0 | |||
| FL03C3 | 100 | EA | $ - 0 | |||
| FL03C4 | 940 | EA | $ - 0 | |||
| FL03C5 | 6 | EA | $ - 0 | |||
| FL03C6 | 6 | EA | $ - 0 | |||
| FL04 | Flammable Corrosive Liquids/Solids/Sludges/Debris/Aerosols. Use LP03 for loose packs other than aerosols. FL04C7 for use with flammable corrosive aerosols only. |
Physical State: Various
| Permissible Waste Codes: UW (Aerosols Only), D001 (IGN), D002, D004-43, Listed. | FL04C1 | 5 | EA | $ - 0 | ||
| FL04C2 | 5 | EA | $ - 0 | |||
| FL04C3 | 5 | EA | $ - 0 | |||
| FL04C4 | 5 | EA | $ - 0 | |||
| FL05 | Flammable Liquids, Pumpable, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates. |
Physical State: Liquid
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL05C1 | 55 | EA | $ - 0 | ||
| FL05C2 | 20 | EA | $ - 0 | |||
| FL05C3 | 50 | EA | $ - 0 | |||
| FL05C4 | 240 | EA | $ - 0 | |||
| FL05C5 | 2 | EA | $ - 0 | |||
| FL05B5 | 70,000 | GL | $ - 0 | |||
| FL06 | Flammable Liquids, Pumpable, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates. |
Physical State: Liquid
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL06C2 | 3 | EA | $ - 0 | ||
| FL06C4 | 16 | EA | $ - 0 | |||
| FL07 | Flammable Liquids, Pumpable, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates. |
Physical State: Liquid
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL07C2 | 3 | EA | $ - 0 | ||
| FL07C3 | 3 | EA | $ - 0 | |||
| FL07C4 | 5 | EA | $ - 0 | |||
| FL07B5 | 5,000 | GL | $ - 0 | |||
| FL09 | Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates. |
Physical State: Various
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL09C2 | 3 | EA | $ - 0 | ||
| FL09C3 | 3 | EA | $ - 0 | |||
| FL09C4 | 3 | EA | $ - 0 | |||
| FL10 | Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates |
Physical State: Various
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL10C2 | 5 | EA | $ - 0 | ||
| FL10C3 | 5 | EA | $ - 0 | |||
| FL11 | Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors. |
Physical State: Liquid
| Permissible Waste Codes: D001 (IGN), D004-43, Listed, UW (Pesticides Only). | FL11C2 | 5 | EA | $ - 0 | ||
| FL11C3 | 5 | EA | $ - 0 | |||
| FL12 | Flammable Solids/Sludges, Highly Chlorinated (>10%), Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors. |
Physical State: Various
| Permissible Waste Codes: D001 (IGN), D004-43, Listed, UW (Pesticides Only). | FL12C1 | 15 | EA | $ - 0 |
| FL13 | Oxidizers, Non-Reactive, Liquids/Sludges/Solids/Debris, other than chromic acid (see Corrosives). |
Physical State: Various
| Permissible Waste Codes: D001(OX), D002, D004-43, Listed. | FL13C1 | 10 | EA | $ - 0 | ||
| FL13C2 | 7 | EA | $ - 0 | |||
| FL13C3 | 15 | EA | $ - 0 | |||
| FL13C4 | 5 | EA | $ - 0 | |||
| FL13C5 | 1 | EA | $ - 0 | |||
| FL15 | Water Contaminated with Common Solvents, pumpable if bulk, <2,500 BTU/Lb. |
Physical State: Liquid
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL15C4 | 5 | EA | $ - 0 | ||
| FL15B5 | 5,000 | GL | $ - 0 | |||
| FL99 | Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for conventional RCRA treatment, disposal. CD required. |
Physical State: Various
| Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed. | FL99C1 | 110 | EA | $ - 0 | ||
| FL99C2 | 10 | EA | $ - 0 | |||
| FL99C3 | 10 | EA | $ - 0 | |||
| FL99C4 | 50 | EA | $ - 0 | |||
| LP01 | Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable. |
Physical State: Various
| Permissible Waste Codes: D002, D004-8, D010-11, Listed Corrosives. | LP01C1 | 110 | EA | $ - 0 | ||
| LP01C2 | 20 | EA | $ - 0 | |||
| LP01C3 | 32 | EA | $ - 0 | |||
| LP01C4 | 11 | EA | $ - 0 | |||
| LP02 | Lab Packs/Loose Packs, Mercury, Elemental Liquid, for mandatory recycling in U.S. |
Physical State: Various
| Permissible Waste Codes: D004-11, Listed Inorganics. | LP02C1 | 5 | EA | $ - 0 | ||
| LP02C2 | 5 | EA | $ - 0 | |||
| LP02C3 | 5 | EA | $ - 0 | |||
| LP03 | Lap Packs/Loose Packs, Flammables and Flammable Corrosives, other than paints and paint-related materials eligible for LP14, for mandatroy RCRA incineration |
Physical State: Various Permissible Waste Codes: D001-2, D004-8, D010-43, Listed Flammables.
| LP03C1 | 332 | EA | $ - 0 | ||
| LP03C2 | 55 | EA | $ - 0 | ||
| LP03C3 | 41 | EA | $ - 0 | ||
| LP03C4 | 30 | EA | $ - 0 | ||
| LP03C6 | 5 | EA | $ - 0 | ||
| LP04 | Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints eligible for LP15, includes pharmaceuticals. |
Physical State: Various
| Permissible Waste Codes: N/A. | LP04C1 | 235 | EA | $ - 0 | ||
| LP04C2 | 35 | EA | $ - 0 | |||
| LP04C3 | 25 | EA | $ - 0 | |||
| LP04C4 | 50 | EA | $ - 0 | |||
| LP04C6 | 1 | EA | $ - 0 | |||
| LP05 | Lab Packs/Loose Packs, Non-Reactive Oxidizers, for mandatory RCRA incineration. |
Physical State: Various
| Permissible Waste Codes: D001 (OX), D002, D004-8, D010-11, Listed. | LP05C1 | 10 | EA | $ - 0 | ||
| LP05C2 | 5 | EA | $ - 0 | |||
| LP05C3 | 5 | EA | $ - 0 | |||
| LP05C4 | 5 | EA | $ - 0 | |||
| LP05C5 | 5 | EA | $ - 0 | |||
| LP06 | Lab Packs/Loose Packs, Reactive Oxidizers, including Organic Peroxides, for mandatory RCRA incineration. Special packaging may be required. |
Physical State: Various
| Permissible Waste Codes: D001 (OX), D002-8, D011-12, Listed. | LP06C1 | 5 | EA | $ - 0 | ||
| LP06C2 | 3 | EA | $ - 0 | |||
| LP06C3 | 3 | EA | $ - 0 | |||
| LP06C4 | 3 | EA | $ - 0 | |||
| LP07 | Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, includes Broken Sodium Lamps, MRE heaters, E-cigarettes and associated components and residues. Special packaging may be required (included in unit price). |
Physical State: Various
| Permissible Waste Codes: D001, D003-8, D010-11, Listed. | LP07C1 | 10 | EA | $ - 0 | ||
| LP07C2 | 10 | EA | $ - 0 | |||
| LP07C3 | 10 | EA | $ - 0 | |||
| LP07C4 | 10 | EA | $ - 0 | |||
| LP07C6 | 5 | EA | $ - 0 | |||
| LP08 | Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, for mandatory RCRA incineration. Special packaging may be required (included in unit price). |
Physical State: Various
| Permissible Waste Codes: D001-8, D010-43, Listed. | LP08C1 | 30 | EA | $ - 0 | ||
| LP08C2 | 5 | EA | $ - 0 | |||
| LP08C3 | 10 | EA | $ - 0 | |||
| LP08C4 | 1 | EA | $ - 0 | |||
| LP08C5 | 2 | EA | $ - 0 | |||
| LP08C6 | 10 | EA | $ - 0 | |||
| LP09 | Lab Packs/Loose Packs, Toxic Metals. |
Physical State: Various
| Permissible Waste Codes: D004-8, D010-11, Listed Inorganic. | LP09C1 | 80 | EA | $ - 0 | ||
| LP09C2 | 15 | EA | $ - 0 | |||
| LP09C3 | 6 | EA | $ - 0 | |||
| LP09C4 | 10 | EA | $ - 0 | |||
| LP10 | Lab Packs/Loose Packs, Toxic Organics, for mandatory RCRA incineration |
Physical State: Various
| Permissible Waste Codes: D004-8, D011-43, Listed. | LP10C1 | 25 | EA | $ - 0 | ||
| LP10C2 | 5 | EA | $ - 0 | |||
| LP10C3 | 5 | EA | $ - 0 | |||
| LP10C4 | 1 | EA | $ - 0 | |||
| LP11 | Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, for mandatory RCRA incineration. Includes pharmaceuticals. May be packaged with U-Listed waste. |
Physical State: Various
| Permissible Waste Codes: D004-8, D010-43, P-Listed, U-Listed, UW (as applicable). | LP11C1 | 15 | EA | $ - 0 | ||
| LP11C2 | 5 | EA | $ - 0 | |||
| LP11C3 | 5 | EA | $ - 0 | |||
| LP11C4 | 5 | EA | $ - 0 | |||
| LP12 | Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory RCRA incineration. |
Physical State: Various
| Permissible Waste Codes: D004-8, D010-43, U-Listed, UW (as applicable). | LP12C1 | 10 | EA | $ - 0 | ||
| LP12C2 | 15 | EA | $ - 0 | |||
| LP12C3 | 190 | EA | $ - 0 | |||
| LP12C4 | 27 | EA | $ - 0 | |||
| LP13 | Lab Packs/Loose Packs, Pesticides, for mandatory RCRA incineration. See CLIN LP77 for management as UW. |
Physical State: Various
| Permissible Waste Codes: D004-8, D010-43, U-Listed. | LP13C1 | 3 | EA | $ - 0 | ||
| LP13C2 | 3 | EA | $ - 0 | |||
| LP13C3 | 3 | EA | $ - 0 | |||
| LP14 | Loose-Packed Paints and Paint-Related Materials, Primarily Oil/Petroleum-Based, >7,000 BTU/Lb, No Isocyanates. May contain <50% Latex paints. Formerly CLIN FL14. |
Physical State: Various
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | LP14C1 | 85 | EA | $ - 0 | ||
| LP14C2 | 35 | EA | $ - 0 | |||
| LP14C3 | 35 | EA | $ - 0 | |||
| LP14C4 | 450 | EA | $ - 0 | |||
| LP14C5 | 2 | EA | $ - 0 | |||
| LP14C6 | 30 | EA | $ - 0 | |||
| LP15 | Loose-Packed Paints and Paint-Related Materials, Water-Based/Latex, Non-RCRA, for solidification and disposal at a RCRA Subtitle D landfill, or equivalent. Formerly CLIN NR06. |
Physical State: Various
| Permissible Waste Codes: N/A. | LP15C1 | 7 | EA | $ - 0 | ||
| LP15C2 | 30 | EA | $ - 0 | |||
| LP15C3 | 6 | EA | $ - 0 | |||
| LP15C4 | 25 | EA | $ - 0 | |||
| LP15C6 | 10 | EA | $ - 0 | |||
| LP77 | Lab Packs/Loose Packs, Pesticides, Managed as UW per 40 CFR 273.3. |
Physical State: Various
| Permissible Waste Codes: U/W. | LP77C1 | 3 | EA | $ - 0 | ||
| LP77C2 | 3 | EA | $ - 0 | |||
| LP77C3 | 3 | EA | $ - 0 | |||
| LP77C4 | 3 | EA | $ - 0 | |||
| LP78 | Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, including pharmaceuticals, for mandatory RCRA Incineration. CD required. |
Physical State: Various
| Permissible Waste Codes: N/A. | LP78C1 | 3 | EA | $ - 0 | ||
| LP78C2 | 3 | EA | $ - 0 | |||
| LP78C3 | 3 | EA | $ - 0 | |||
| LP78C4 | 3 | EA | $ - 0 | |||
| LP79 | Lab Packs/Loose Packs, Miscellaneous laboratory-related wastes including preserved specimens, microscope slides, etc. No infectious or biohazardous wastes. May require a Non-Biohazardous or Non-Infectious Certificate. |
Physical State: Various
| Permissible Waste Codes: N/A. | LP79C1 | 2 | EA | $ - 0 | ||
| LP79C2 | 2 | EA | $ - 0 | |||
| LP79C3 | 2 | EA | $ - 0 | |||
| LP79C4 | 2 | EA | $ - 0 | |||
| NR01 | Non-RCRA Solids/Debris, for direct disposal at a RCRA Subtitle D landfill, or equivalent. Passes paint filter test. No asbestos. May include drained/dry non-PCB transformers, ballasts, capacitors, and related equipment. |
Physical State: Solid
| Permissible Waste Codes: N/A. | NR01C1 | 85 | EA | $ - 0 | ||
| NR01C2 | 13 | EA | $ - 0 | |||
| NR01C3 | 110 | EA | $ - 0 | |||
| NR01C4 | 2,600 | EA | $ - 0 | |||
| NR01C5 | 13 | EA | $ - 0 | |||
| NR01C6 | 20 | EA | $ - 0 | |||
| NR01B1 | 33,000 | LB | $ - 0 | |||
| NR01B2 | 385,800 | LB | $ - 0 | |||
| NR01B3 | 205,500 | LB | $ - 0 | |||
| NR01B4 | 980,000 | LB | $ - 0 | |||
| NR01B6 | 3,380 | CD | $ - 0 | |||
| NR02 | Non-RCRA Solids/Debris with Asbestos, for direct disposal at a TSCA/RCRA Subtitle D landfill, or equivalent. Passes paint filter test. Special packaging may be required. |
Physical State: Solid
| Permissible Waste Codes: N/A. | NR02C1 | 5 | EA | $ - 0 | ||
| NR02C3 | 5 | EA | $ - 0 | |||
| NR02C4 | 250 | EA | $ - 0 | |||
| NR02C6 | 5 | EA | $ - 0 | |||
| NR02B6 | 15 | CD | $ - 0 | |||
| NR03 | Non-RCRA Liquids, Water-Based, pumpable. NR03B5 must meet acceptance criteria for wastewater treatment (WWT) and discharge to POTW, per Section 3.29. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | NR03C1 | 630 | EA | $ - 0 | ||
| NR03C2 | 5 | EA | $ - 0 | |||
| NR03C3 | 20 | EA | $ - 0 | |||
| NR03C4 | 130 | EA | $ - 0 | |||
| NR03C5 | 1 | EA | $ - 0 | |||
| NR03B5 | 10,000 | GL | $ - 0 | |||
| NR04 | Non-RCRA Liquids, Organic-Based, pumpable, primarily consisting of wastes containing hydrocarbons. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | NR04C1 | 21 | EA | $ - 0 | ||
| NR04C2 | 3 | EA | $ - 0 | |||
| NR04C3 | 5 | EA | $ - 0 | |||
| NR04C4 | 35 | EA | $ - 0 | |||
| NR04T1 | 5 | EA | $ - 0 | |||
| NR04T2 | 5 | EA | $ - 0 | |||
| NR04T3 | 5 | EA | $ - 0 | |||
| NR05 | Non-RCRA Liquids/Sludges/Solids/Debris, requiring solidification prior to disposal at a RCRA Subtitle D landfill, or equivalent. Includes bulk liquids not meeting acceptance criteria for wastewater treatment (WWT). May include non-PCB oil-filled transformers, ballasts, capacitors and related equipment, per Section 3.29 |
Physical State: Various
| Permissible Waste Codes: N/A. | NR05C1 | 150 | EA | $ - 0 | ||
| NR05C2 | 30 | EA | $ - 0 | |||
| NR05C3 | 90 | EA | $ - 0 | |||
| NR05C4 | 715 | EA | $ - 0 | |||
| NR05C5 | 1 | EA | $ - 0 | |||
| NR05B1 | 10,000 | LB | $ - 0 | |||
| NR05B5 | 815,000 | GL | $ - 0 | |||
| NR07 | Non-RCRA Pharmaceuticals for Thermal Destruction, Prescription and Non-Prescription. No DEA Restricted Meds. Certificate of Destruction Required. |
Physical State: Various
| Permissible Waste Codes: N/A. | NR07C4 | 27 | EA | $ - 0 |
| NR09 | Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Metal and/or Plastic/Poly, crushed or damaged, for Contractor's choice of Recycle or Disposal. |
Physical State: Solid
| Permissible Waste Codes: N/A. | NR09C4 | 1,790 | EA | $ - 0 | ||
| NR09T1 | 10 | EA | $ - 0 | |||
| NR09T2 | 10 | EA | $ - 0 | |||
| NR09T3 | 10 | EA | $ - 0 | |||
| NR10 | Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Plastic/Poly Only, Intact, for Contractor's choice of Recycle or Disposal. Totes (T1-T3) may have metal components. |
Physical State: Solid
| Permissible Waste Codes: N/A. | NR10C2 | 7 | EA | $ - 0 | ||
| NR10C3 | 10 | EA | $ - 0 | |||
| NR10C4 | 137 | EA | $ - 0 | |||
| NR10T1 | 5 | EA | $ - 0 | |||
| NR10T2 | 5 | EA | $ - 0 | |||
| NR10T3 | 5 | EA | $ - 0 | |||
| NR79 | Non-RCRA Solids @ Barstow, POL-Contaminated Items, e.g., pads, rags, booms, sweepables, etc. for mandatory recycling or WTE. Contractor returns empty containers to Generator for reuse. Physical State: Solid | |||||
| Permissible Waste Codes: N/A. | NR79C4 | 1,445 | EA | $ - 0 | ||
| NR90 | Non-RCRA AFFF-Related Solids/Sludges/Debris for RCRA Incineration, e.g., soil, gravel, filter media, tank bladders, etc. May contain some free liquids. CD required. |
Physical State: Various
| Permissible Waste Codes: N/A. | NR90C1 | 5 | EA | $ - 0 | ||
| NR90C2 | 5 | EA | $ - 0 | |||
| NR90C3 | 5 | EA | $ - 0 | |||
| NR90C4 | 5 | EA | $ - 0 | |||
| NR90B1 | 15,000 | LB | $ - 0 | |||
| NR90B2 | 15,000 | LB | $ - 0 | |||
| NR90B3 | 15,000 | LB | $ - 0 | |||
| NR93 | Non-RCRA AFFF Concentrate Liquids for RCRA Incineration, pumpable, unused or >10% AFFF product by volume. CD required. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | NR93C1 | 5 | EA | $ - 0 | ||
| NR93C2 | 5 | EA | $ - 0 | |||
| NR93C3 | 5 | EA | $ - 0 | |||
| NR93C4 | 5 | EA | $ - 0 | |||
| NR93C5 | 1 | EA | $ - 0 | |||
| NR94 | Non-RCRA AFFF Rinsates and other impacted waters for RCRA Incineration, Pumpable, Used or >90% water by volume. Bulk removals may be from storage tanks, containment, storm sewer, ground and surface waters. CD required. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | NR94C1 | 5 | EA | $ - 0 | ||
| NR94C2 | 5 | EA | $ - 0 | |||
| NR94C3 | 5 | EA | $ - 0 | |||
| NR94C4 | 5 | EA | $ - 0 | |||
| NR94C5 | 1 | EA | $ - 0 | |||
| NR94T1 | 20 | EA | $ - 0 | |||
| NR94T2 | 20 | EA | $ - 0 | |||
| NR94T3 | 20 | EA | $ - 0 | |||
| NR94B5 | 25,000 | GL | $ - 0 | |||
| NR95 | Non-Regulated Electron Tubes, Demil-Required, for direct disposal at a RCRA Subtitle D landfill, or equivalent. CD required. |
Physical State: Solid
| Permissible Waste Codes: N/A. | NR95C1 | 5 | EA | $ - 0 | ||
| NR95C2 | 5 | EA | $ - 0 | |||
| NR95C3 | 5 | EA | $ - 0 | |||
| NR95C4 | 5 | EA | $ - 0 | |||
| NR96 | Non-RCRA Liquids for RCRA Incineration, pumpable. Not used for AFFF or other PFAS-related wastes. CD required. Physical State: Liquid | |||||
| Permissible Waste Codes: N/A. | NR96C1 | 5 | EA | $ - 0 | ||
| NR96C2 | 5 | EA | $ - 0 | |||
| NR96C3 | 5 | EA | $ - 0 | |||
| NR96C4 | 5 | EA | $ - 0 | |||
| NR96T1 | 5 | EA | $ - 0 | |||
| NR96T2 | 5 | EA | $ - 0 | |||
| NR96T3 | 5 | EA | $ - 0 | |||
| NR97 | Non-RCRA Solids/Sludges/Debris for RCRA Incineration. May contain some free liquids. Not used for AFFF or other PFAS-related wastes. CD required. |
Physical State: Various
| Permissible Waste Codes: N/A. | NR97C3 | 10 | EA | $ - 0 | ||
| NR97C4 | 10 | EA | $ - 0 | |||
| NR98 | Non-RCRA Military Articles, Demil-Required, e.g., boots, gloves, CDE kits, filters, masks, MOPP suits, etc. for direct disposal at a RCRA Subtitle D landfill, or equivalent. CD required. No uniforms (NR99) or submarine tiles (TX99). |
Physical State: Various
| Permissible Waste Codes: N/A. | NR98C4 | 1 | EA | $ - 0 |
| PC01 | PCB wastes containing or contaminated with a ≥50 ppm PCB Source (≥5 ppm in CA), RCRA or Non-RCRA, e.g., fluids, soil, sludge, debris, leaking capacitors. CD required. |
Physical State: Various
| Permissible Waste Codes: D001-43, Listed. | PC01C7 | 500 | LB | $ - 0 |
| PC02 | PCB Mineral Oil from Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | PC02C7 | 800 | LB | $ - 0 |
| PC03 | PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs (5-4,000 ppm in CA). Non-RCRA, CD or Cert of Recycling required. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | PC03C7 | 800 | LB | $ - 0 |
| PC04 | PCB Mineral Oil, Water, Other Fluids, >4,000 ppm PCBs. RCRA or Non-RCRA. CD required. |
Physical State: Liquid
| Permissible Waste Codes: D001-43, Listed. | PC04C7 | 2,000 | LB | $ - 0 |
| PC05 | PCB Oil-Filled Capacitors/Equipment other than Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA. |
Physical State: Various
| Permissible Waste Codes: N/A. | PC05C7 | 800 | LB | $ - 0 |
| PC06 | PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, ≥50 ppm PCBs (≥5 ppm in CA), Non-RCRA, CD or Cert of Recycling required. |
Physical State: Various
| Permissible Waste Codes: N/A. | PC06C7 | 400 | LB | $ - 0 |
| PC07 | PCB Oil-Filled Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA. |
Physical State: Various
| Permissible Waste Codes: N/A. | PC07C7 | 800 | LB | $ - 0 |
| PC08 | PCB Oil-Filled Transformers, ≥50 ppm PCBs (≥5 ppm in CA). CD or Cert of Recycling required. |
Physical State: Various
| Permissible Waste Codes: N/A. | PC08C7 | 500 | LB | $ - 0 |
| PC09 | PCB Solids/Debris Contaminated with <50 ppm Source (<5 ppm in CA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. |
Physical State: Solid
| Permissible Waste Codes: N/A. | PC09C7 | 2,400 | LB | $ - 0 |
| PC10 | PCB Solids/Debris Contaminated with ≥50 ppm Source (≥5 ppm in CA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. CD or Cert of Recycling require. |
Physical State: Solid
| Permissible Waste Codes: N/A. | PC10C7 | 2,400 | LB | $ - 0 |
| PC11 | PCB and Non-PCB Related ballasts and other devices containing <50 ppm (<5 ppm in CA) for Mandatory Recycling of recyclable components. Cert of Recycling required. |
Physical State: Various
| Permissible Waste Codes: N/A. | PC11C7 | 5,000 | LB | $ - 0 |
| PC12 | PCB Related ballasts and other devices containing ≥50 ppm (≥5 ppm in CA) for Mandatory Recycling of recyclable components. Cert of Recycling required. |
Physical State: Various
| Permissible Waste Codes: N/A. | PC12C7 | 1,200 | LB | $ - 0 |
| PF03 | AFFF and other PFAS-related Liquids/Waters, Non-RCRA, >100 ppm PFAS, for treatment and disposal at RCRA Subtitle C Landfill or equivalent. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates & Concentrates. CD Required. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | PF03C1 | 1 | EA | $ - 0 | ||
| PF03C4 | 1 | EA | $ - 0 | |||
| PF03C5 | 1 | EA | $ - 0 | |||
| PF03T2 | 1 | EA | $ - 0 | |||
| PF03B5 | 1,500 | GL | $ - 0 | |||
| PF31 | AFFF and other PFAS-related Liquids/Waters, Non-RCRA, <1.0 ppm PFAS, for treatment and disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates. CD Required. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | PF31C1 | 1 | EA | $ - 0 | ||
| PF31C4 | 1 | EA | $ - 0 | |||
| PF31T2 | 1 | EA | $ - 0 | |||
| PF31B5 | 5,000 | GL | $ - 0 | |||
| PF32 | AFFF and other PFAS-related Liquids/Waters, Non-RCRA, 1-100 ppm PFAS, for treatment and disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates. CD Required. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | PF32C1 | 1 | EA | $ - 0 | ||
| PF32C4 | 1 | EA | $ - 0 | |||
| PF32C5 | 1 | EA | $ - 0 | |||
| PF32T2 | 1 | EA | $ - 0 | |||
| PF32B5 | 5,000 | GL | $ - 0 | |||
| PF33 | AFFF and other PFAS-related Liquids/Waters, Non-RCRA, 100-1,000 ppm PFAS, for treatment and disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates. CD Required. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | PF33C1 | 1 | EA | $ - 0 | ||
| PF33C4 | 1 | EA | $ - 0 | |||
| PF33C5 | 1 | EA | $ - 0 | |||
| PF33T2 | 1 | EA | $ - 0 | |||
| PF33B5 | 5,000 | GL | $ - 0 | |||
| PF34 | AFFF and other PFAS-related Solids/Debris, Non-RCRA, <1.0 ppm PFAS, for direct disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. Passes Paint Filter Test. No Cylinders. CD Required. |
Physical State: Solid
| Permissible Waste Codes: N/A. | PF34C1 | 1 | EA | $ - 0 | ||
| PF34C4 | 1 | EA | $ - 0 | |||
| PF34B1 | 7,500 | LB | $ - 0 | |||
| PF34B2 | 15,000 | LB | $ - 0 | |||
| PF34B3 | 25,000 | LB | $ - 0 | |||
| PF34B4 | 35,000 | LB | $ - 0 | |||
| PF34B6 | 15 | CD | $ - 0 | |||
| PF35 | AFFF and other PFAS-related Solids/Debris, Non-RCRA, 1-100 ppm PFAS, for direct disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. Passes Paint Filter Test. No Cylinders. CD Required. |
Physical State: Solid
| Permissible Waste Codes: N/A. | PF35C1 | 1 | EA | $ - 0 | ||
| PF35C4 | 1 | EA | $ - 0 | |||
| PF35C6 | 1 | EA | $ - 0 | |||
| PF35B1 | 7,500 | LB | $ - 0 | |||
| PF35B2 | 15,000 | LB | $ - 0 | |||
| PF35B3 | 25,000 | LB | $ - 0 | |||
| PF35B4 | 35,000 | LB | $ - 0 | |||
| PF35B6 | 15 | CD | $ - 0 | |||
| PF36 | AFFF and other PFAS-related Solids/Debris, Non-RCRA, >100 ppm PFAS, for direct disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. Passes Paint Filter Test. No Cylinders. CD Required. |
Physical State: Solid
| Permissible Waste Codes: N/A. | PF36C1 | 1 | EA | $ - 0 | ||
| PF36C4 | 1 | EA | $ - 0 | |||
| PF36C6 | 1 | EA | $ - 0 | |||
| PF36B1 | 7,500 | LB | $ - 0 | |||
| PF36B2 | 15,000 | LB | $ - 0 | |||
| PF36B3 | 25,000 | LB | $ - 0 | |||
| PF36B4 | 35,000 | LB | $ - 0 | |||
| PF36B6 | 15 | CD | $ - 0 | |||
| PF37 | AFFF and other PFAS-related Solids/Sludges/Debris with Free Liquids, Non-RCRA, <1.0 ppm PFAS, for treatment and disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. No Cylinders. CD Required. |
Physical State: Various
| Permissible Waste Codes: N/A. | PF37C1 | 1 | EA | $ - 0 | ||
| PF37C4 | 1 | EA | $ - 0 | |||
| PF37C5 | 1 | EA | $ - 0 | |||
| PF37B1 | 7,500 | LB | $ - 0 | |||
| PF37B2 | 15,000 | LB | $ - 0 | |||
| PF37B3 | 25,000 | LB | $ - 0 | |||
| PF37B4 | 35,000 | LB | $ - 0 | |||
| PF37B6 | 15 | CD | $ - 0 | |||
| PF38 | AFFF and other PFAS-related Solids/Sludges/Debris with Free Liquids, Non-RCRA, 1-100 ppm PFAS, for treatment and disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. No Cylinders. CD Required. |
Physical State: Various
| Permissible Waste Codes: N/A. | PF38C1 | 1 | EA | $ - 0 | ||
| PF38C4 | 1 | EA | $ - 0 | |||
| PF38C5 | 1 | EA | $ - 0 | |||
| PF38B1 | 7,500 | LB | $ - 0 | |||
| PF38B2 | 15,000 | LB | $ - 0 | |||
| PF38B3 | 25,000 | LB | $ - 0 | |||
| PF38B4 | 35,000 | LB | $ - 0 | |||
| PF38B6 | 15 | CD | $ - 0 | |||
| PF39 | AFFF and other PFAS-related Solids/Sludges/Debris with Free Liquids, Non-RCRA, >100 ppm PFAS, for treatment and disposal at Contractor's choice of RCRA Subtitle D or Subtitle C Landfill, or equivalent. No Cylinders. CD Required. |
Physical State: Various
| Permissible Waste Codes: N/A. | PF39C1 | 1 | EA | $ - 0 | ||
| PF39C4 | 1 | EA | $ - 0 | |||
| PF39C5 | 1 | EA | $ - 0 | |||
| PF39B1 | 75,000 | LB | $ - 0 | |||
| PF39B2 | 15,000 | LB | $ - 0 | |||
| PF39B3 | 25,000 | LB | $ - 0 | |||
| PF39B4 | 35,000 | LB | $ - 0 | |||
| PF39B6 | 15 | CD | $ - 0 | |||
| RE01 | Lamps, Fluorescent, Intact, CFLs, U-Bent, Circulars. |
Physical State: Solid
| Permissible Waste Codes: Universal Waste, D004-11. | RE01C7 | 45,000 | LB | $ - 0 |
| RE02 | Lamps, Fluorescent, Crushed/Broken, may contain filters |
Physical State: Solid
| Permissible Waste Codes: Universal Waste, D004-11. | RE02C1 | 30 | EA | $ - 0 | ||
| RE02C4 | 15 | EA | $ - 0 | |||
| RE03 | Lamps, Halogen. |
Physical State: Solid
| Permissible Waste Codes: Universal Waste, D004-11. | RE03C7 | 3,000 | LB | $ - 0 |
| RE04 | Lamps, High Intensity Discharge (HID) and/or Light Emitting Diode (LED), Incandescent. |
Physical State: Solid
| Permissible Waste Codes: Universal Waste D004-11. | RE04C7 | 3,000 | LB | $ - 0 |
| RE05 | Lamps, Mercury/Mercury Vapor. |
Physical State: Solid
| Permissible Waste Codes: Universal Waste D004-11. | RE05C7 | 1,100 | LB | $ - 0 |
| RE06 | Lamps, Metal Halide and Metal Hydride, including Sodium. |
Physical State: Solid
| Permissible Waste Codes: Universal Waste D003-11. | RE06C7 | 1,100 | LB | $ - 0 |
| RE08 | Mercury, High, Dental Amalgams & Residues, Hg >260 mg/Kg. |
Physical State: Various
| Permissible Waste Codes: UW, D004-11. | RE08C1 | 1 | EA | $ - 0 | ||
| RE08C4 | 5 | EA | $ - 0 | |||
| RE09 | Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg. |
Physical State: Various
| Permissible Waste Codes: UW, D004-11. | RE09C1 | 17 | EA | $ - 0 | ||
| RE09C4 | 3 | EA | $ - 0 | |||
| RE10 | Antifreeze, Used and Unused for Recycling or Fuels Blending. RE10ME refers to 55-gal containers (Min: 30 EA) pumped or vacuumed onsite, includes recycling and service. Empty containers are left with Generator. |
Physical State: Liquid
| Permissible Waste Codes: UW. | RE10C1 | 25 | EA | $ - 0 | ||
| RE10C2 | 5 | EA | $ - 0 | |||
| RE10C3 | 5 | EA | $ - 0 | |||
| RE10C4 | 65 | EA | $ - 0 | |||
| RE10T1 | 5 | EA | $ - 0 | |||
| RE10T2 | 5 | EA | $ - 0 | |||
| RE10T3 | 5 | EA | $ - 0 | |||
| RE10B5 | 10,000 | GL | $ - 0 | |||
| RE11 | Used Oil, <10% Water, <1,000 ppm Total Organic Halides. RE11ME refers to 55-gal containers (Min: 30 EA) pumped or vacuumed onsite, includes recycling and service. Empty containers are left with Generator. |
Physical State: Liquid
| Permissible Waste Codes: UW. | RE11C4 | 13 | EA | $ - 0 | ||
| RE11B5 | 5,000 | GL | $ - 0 | |||
| RE11ME | 2,400 | EA | $ - 0 | |||
| RE12 | Used Oil, >10% Water, <1,000 ppm Total Organic Halides. RE12ME refers to 55-gal containers (Min: 30 EA) pumped or vacuumed onsite, includes recycling and service. Empty containers are left with Generator. |
Physical State: Liquid
| Permissible Waste Codes: UW. | RE12C4 | 1 | EA | $ - 0 | ||
| RE12B5 | 20,000 | GL | $ - 0 | |||
| RE12ME | 30 | EA | $ - 0 | |||
| RE13 | Used Oil Filters, Drained and Undrained, and/or Fully Drained Fuel Filters. |
Physical State: Various
| Permissible Waste Codes: UW, D004-11. | RE13C1 | 16 | EA | $ - 0 | ||
| RE13C2 | 7 | EA | $ - 0 | |||
| RE13C3 | 6 | EA | $ - 0 | |||
| RE13C4 | 365 | EA | $ - 0 | |||
| RE14 | Lead Articles and Spent Ammunitions Meeting Specs for Recovery. |
Physical State: Solid
| Permissible Waste Codes: UW, D004-11. | RE14C1 | 5 | EA | $ - 0 | ||
| RE14C4 | 5 | EA | $ - 0 | |||
| RE15 | Non-PCB Ballasts, Capacitors, Equipment for Recycling. Drained and Undrained. Non-TSCA, Non-RCRA. |
Physical State: Various.
| Permissible Waste Codes: N/A. | RE15C7 | 185,200 | LB | $ - 0 |
| RE75 | Spent Solvents, not eligible for Fuels Blending. Contractor must use Management Method Code H010, H020, and/or H039 for treatment. |
Physical State: Various
| Permissible Waste Codes: D001, D004-43, Listed. | RE75C1 | 5 | EA | $ - 0 | ||
| RE75C2 | 5 | EA | $ - 0 | |||
| RE75C3 | 5 | EA | $ - 0 | |||
| RE75C4 | 5 | EA | $ - 0 | |||
| RE76 | Mixed Lamps for recycling. |
Physical State: Solid
| Permissible Waste Codes: UW, D004-11. | RE76C7 | 3,000 | LB | $ - 0 |
| RE78 | Aerosols, California UW for recycling. No Corrosives or Reactives. |
Physical State: Various
| Permissible Waste Codes: UW. | RE78C7 | 81,400 | LB | $ - 0 |
| RX01 | Aerosols, Foaming, Isocyanates or other reactives. |
Physical State: Various Permissible Waste Codes: UW, D001-43, Listed.
| RX01C7 | 550 | LB | $ - 0 |
| RX05 | Cyanide Liquids, Solids, <50% Debris, >10% Total CN. |
Physical State: Various
| Permissible Waste Codes: D002-11, Listed. | RX05C1 | 1 | EA | $ - 0 | ||
| RX06 | Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic Peroxides. | |||||
| Physical State: Various Permissible Waste Codes: D001-11, Listed. | RX06C1 | 3 | EA | $ - 0 | ||
| RX06C2 | 3 | EA | $ - 0 | |||
| RX06C3 | 3 | EA | $ - 0 | |||
| RX06C4 | 3 | EA | $ - 0 | |||
| RX08 | Reactive Metals, e.g., powders, dusts, fines. Air/Water Reactive. Shipped under oil and/or other special packaging may be required. |
Physical State: Solid
| Permissible Waste Codes: D001, D003, D004-11, Listed. | RX08C1 | 10 | EA | $ - 0 | ||
| RX08C2 | 10 | EA | $ - 0 | |||
| RX08C3 | 17 | EA | $ - 0 | |||
| RX08C4 | 115 | EA | $ - 0 | |||
| RX09 | Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or Special Packaging may be required. |
Physical State: Solid
| Permissible Waste Codes: D001, D003, D004-11, Listed. | RX09C4 | 5 | EA | $ - 0 |
| RX10 | Reactive Non-Metals, e.g., P-Coded, Temperature Sensitive, PIHs, Air and/or Water Reactive. |
Physical State: Various
| Permissible Waste Codes: D001-11, Listed. | RX10C1 | 5 | EA | $ - 0 |
| RX98 | OBA Canisters, EEBDs and Oxygen Candles, Potentially Reactive, Spent and/or Unspent. Special packaging may be required. |
Physical State: Solid
| Permissible Waste Codes: D001, D003, D004-11. | RX98C4 | 37 | EA | $ - 0 |
| RX99 | Military Items, Demil-Required, Reactive, Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. (No Batteries) for Conventional RCRA Treatment and Disposal. Must Carry D003. CD required. |
Physical State: Various
| Permissible Waste Codes: D001-D043, Listed. | RX99C1 | 5 | EA | $ - 0 | ||
| RX99C4 | 5 | EA | $ - 0 | |||
| RX99C6 | 5 | EA | $ - 0 | |||
| TX06 | Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater/condensation (See TX20). |
Physical State: Debris
| Permissible Waste Codes: D004-11, Listed Inorganics. | TX06C1 | 10 | EA | $ - 0 | ||
| TX06C4 | 60 | EA | $ - 0 | |||
| TX06C6 | 40 | EA | $ - 0 | |||
| TX06B1 | 10,000 | LB | $ - 0 | |||
| TX06B6 | 85 | CD | $ - 0 | |||
| TX07 | Debris, Organic Constituents. >50% Debris by volume, >60 mm (~2.5") particle size. Total VOCs <500 ppm. No free liquids unless incidental rainwater or condensation (see TX20). May include inorganic Waste Code(s) and/or RCRA hazardous asbestos. |
Physical State: Debris
| Permissible Waste Codes: D004-43, Listed, but no F020-32. | TX07C1 | 35 | EA | $ - 0 | ||
| TX07C2 | 20 | EA | $ - 0 | |||
| TX07C3 | 30 | EA | $ - 0 | |||
| TX07C4 | 1,015 | EA | $ - 0 | |||
| TX07C6 | 20 | EA | $ - 0 | |||
| TX07B1 | 10,000 | LB | $ - 0 | |||
| TX07B6 | 660 | CD | $ - 0 | |||
| TX09 | High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides. |
Physical State: Various
| Permissible Waste Codes: UW, D004-43, Listed. | TX09C1 | 19 | EA | $ - 0 | ||
| TX09C3 | 36 | EA | $ - 0 | |||
| TX09C4 | 150 | EA | $ - 0 | |||
| TX10 | Metals in Wastewater, <5% Suspended Solids, <1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. |
Physical State: Liquid
| Permissible Waste Codes: D004-11, Listed Inorganics. | TX10C1 | 1 | EA | $ - 0 | ||
| TX10C4 | 60 | EA | $ - 0 | |||
| TX10B5 | 50,000 | GL | $ - 0 | |||
| TX12 | Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Characteristic only. |
Physical State: Liquid
| Permissible Waste Codes: D004-11. | TX12C1 | 10 | EA | $ - 0 | ||
| TX12C2 | 5 | EA | $ - 0 | |||
| TX12C3 | 6 | EA | $ - 0 | |||
| TX12C4 | 200 | EA | $ - 0 | |||
| TX12T1 | 3 | EA | $ - 0 | |||
| TX12T2 | 3 | EA | $ - 0 | |||
| TX12T3 | 3 | EA | $ - 0 | |||
| TX12B5 | 10,000 | GL | $ - 0 | |||
| TX13 | Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Listed, or Listed + Characteristic. |
Physical State: Liquid
| Permissible Waste Codes: D004-11, Listed. | TX13C2 | 5 | EA | $ - 0 |
| TX16 | Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. Characteristic only. |
Physical State: Various
| Permissible Waste Codes: D004-11. | TX16C1 | 14 | EA | $ - 0 | ||
| TX16C3 | 3 | EA | $ - 0 | |||
| TX16C4 | 310 | EA | $ - 0 | |||
| TX16C6 | 86 | EA | $ - 0 | |||
| TX16B1 | 20,000 | LB | $ - 0 | |||
| TX16B2 | 40,000 | LB | $ - 0 | |||
| TX16B3 | 60,000 | LB | $ - 0 | |||
| TX17 | Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. Listed, or Listed + Characteristic. |
Physical State: Various
| Permissible Waste Codes: D004-11, Listed Inorganics. | TX17C1 | 5 | EA | $ - 0 | ||
| TX17C2 | 5 | EA | $ - 0 | |||
| TX17C3 | 5 | EA | $ - 0 | |||
| TX17C4 | 60 | EA | $ - 0 | |||
| TX21 | Organics Contaminated Water, Pumpable, <10% Suspended Solids, <10% Organics, e.g., Toluene, Phenol in water. Not more toxic than common solvents. |
Physical State: Liquid
| Permissible Waste Codes: D004-43, Listed. | TX21B5 | 15,000 | GL | $ - 0 |
| TX22 | Organics in Solids/Sludges/Debris, i.e. soil, tank & still bottoms, adhesives, filtercake. Not more toxic than common solvents. |
Physical State: Various
| Permissible Waste Codes: D004-43, Listed. | TX22C1 | 5 | EA | $ - 0 | ||
| TX22C2 | 5 | EA | $ - 0 | |||
| TX22C3 | 5 | EA | $ - 0 | |||
| TX22C4 | 66 | EA | $ - 0 | |||
| TX23 | Toxic/Hazardous Solids and Debris meeting Universal Treatment Standards (UTS). Subtitle C (or equivalent) landfill-ready. Passes paint filter test. No PCBs. |
Physical State: Solid
| Permissible Waste Codes: Listed. | TX23C1 | 5 | EA | $ - 0 | ||
| TX23C2 | 5 | EA | $ - 0 | |||
| TX23C3 | 5 | EA | $ - 0 | |||
| TX23C4 | 5 | EA | $ - 0 | |||
| TX24 | Organic Solvents, Technical Grade, pure or mixed solutions, with or without water and/or metals, pumpable if bulk, Flashpoint ≥140°F. |
Physical State: Liquid
| Permissible Waste Codes: D004-43, Listed. | TX24C1 | 3 | EA | $ - 0 | ||
| TX24C2 | 3 | EA | $ - 0 | |||
| TX24C3 | 3 | EA | $ - 0 | |||
| TX24C4 | 3 | EA | $ - 0 | |||
| TX97 | Toxic Electron Tubes, intact, Demil-required. CD required. |
Physical State: Solid
| Permissible Waste Codes: D004-11. | TX97C4 | 5 | EA | $ - 0 | ||
| TX98 | Military Items, Demil-required, RCRA Toxic, e.g., CDE Kits, Tents, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. CD required. Physical State: Various Permissible Waste Codes: D004-D011, Listed. | TX98C4 | 5 | EA | $ - 0 | |
| TX98C6 | 5 | EA | $ - 0 |
Total: $ - 0
Option Leach Master HW Disposal Contract - IGE Barstow/China Lake Price Schedule - Option (30 Months)
| Base | ||||||
| CLIN | Description | CLIN | Est. Qty (30 Months) | U/I | Price | Extended Cost |
| SERVICE CLINs | ||||||
| 1001SA | Perform sampling and analysis to determine Waste Characteristics (D001-D0043) using current SW-846 Methods. Provide Hazardous Waste Profile Sheet (HWPS) (See 3.26). | 1001SA | 25 | EA | $ - 0 | |
| 1020RE | Daily Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2). | 1020RE | 20 | EA | $ - 0 | |
| 1021RE | Weekly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3). | 1021RE | 50 | EA | $ - 0 | |
| 1022RE | Monthly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4). | 1022RE | 50 | EA | $ - 0 |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .