This is a submittal schedule for the MAF Lagoon Electrical project at Malmstrom AFB, Montana, detailing required documentation and materials that must be submitted by the contractor. The schedule is organized into multiple divisions including General Requirements, Site Security, Environmental, Electrical, Cast-in-Place Concrete, Earthwork, and Exterior Improvements.
Key submittals include project schedules, quality control plans, environmental protection documents, electrical components (conductors, cables, conduits, panels, receptacles), concrete specifications, and seeding requirements. Most technical submittals require approval 30 days prior to start of work (PTSW). The contractor must provide various ongoing submittals throughout the project, such as weekly work schedules, daily quality control records, and bi-monthly progress reports. Environmental requirements include hazardous materials documentation and waste disposal reporting. The electrical scope encompasses low-voltage power conductors, raceways, boxes, identification systems, and panelboards for the lagoon electrical installation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 04_24-6000 Project Drawings.pdf | ||
| 01_MAF Lagoon Electrical Specificaitons.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MALMSTROM AFB, MONTANA
SCHEDULE OF MATERIALS SUBMITTALS Project Number Project Title: Solicitation/Contract No.
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE,
TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
R 'S
E C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
W
A R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
IN
G
ST
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
D
SU
B
M
IS
SI
O
N D
A T
(B Y
C
O N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
IV
IL
N
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
SE
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
L
FI
A L
A
PP
R O
V A
L
REMARKS
APPROVED
DIS-
APPRO
VED
DIVISION 01 - GENERAL
REQUIREMENTS
1 01 00 00 General Requirements - 3.6.2 Overall Project Schedule X 30D
PTSW
2 01 00 00 General Requirements - 3.6.3 Weekly Schedule of Work X Weekly
3 01 00 00 General Requirements - 3.8 Start of Work Notification X 5D PTE
4 01 00 00 General Requirements - 3.11 Utility Outages X 10D
PTE
5 01 00 00 General Requirements - 3.13.2 Quality Control Plan X 10D
ANP
6 01 00 00 General Requirements - 3.13.5 Quality Control Records X Daily
7 01 00 00 General Requirements - 3.16 Operating and Maintenance Instructions X 10D
PTFI
8 01 00 00 General Requirements - 3.16.5 As-Built Field Drawings and Data X 10D
PTFI
9 01 00 00 General Requirements - 3.16 Operating and Maintenance Instructions X 20D AFI
10 01 00 00 General Requirements - 3.16.5 As-Built Field Drawings and Data X 20D AFI
11 01 00 00 General Requirements - 3.22.1 Work Clearance Request X 30D
PTSW
Number of Copies Required
NZAS 24-6000 MAF Lagoon Electrical
DATE CONTRACTOR
NOTIFIED
AF Form 66 02_24-6000 Submittal Schedule-1/15/2025
01330a-1
REQUIRED TECHNICAL SUBMITTALS
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE,
TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
APPROVED
DIS-
APPRO
VED
Number of Copies Required
NZAS 24-6000 MAF Lagoon Electrical
DATE CONTRACTOR
NOTIFIED
12 01 00 00 General Requirements - 3.25 Nuclear Densometers Information X 1W PTE
13 01 00 00 General Requirements - 3.26 Notice of Final Inspection and Acceptance X 7D PTE
14 01 00 00 General Requirements - 3.27 Progress Schedule Form 3064 X Bi-monthly
15 01 00 00 General Requirements - 3.27 Progress Report Form 3065 X Bi-monthly
SECTION 01 10 00 - SITE
SECURITY
16 01 10 00 Site Security - 1.4 Contractor Entry Authorization List (CEAL) X 30D
PTSW
17 01 10 00 Site Security - 1.9.3 Entry and Exit Times X 1W AE
SECTION 01 36 00 -
ENVIRONMENTAL
18 01 36 00 Environmental Protection - 2.3 Environmental Deliverables X 5D
PTSW
19 01 36 00 Environmental Protection - 4.2.2.1 Notice of Intent Package X 10D
PTSW
20 01 36 00 Environmental Protection - 8.2.1 List of Hazardous Materials (1360-5) with SDS X 30D
PTSW
AF Form 66 02_24-6000 Submittal Schedule-1/15/2025
01330a-2
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE,
TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
APPROVED
DIS-
APPRO
VED
Number of Copies Required
NZAS 24-6000 MAF Lagoon Electrical
DATE CONTRACTOR
NOTIFIED
21 01 36 00 Environmental Protection - 8.5 HAZMART Account Close-out Report X 10D
PTFI
22 01 36 00 Environmental Protection - 8.5 HAZMART Account Close-out Report X 10D
PTFI
01 36 00 Environmental Protection - 11.5.2 "Monthly Report of Solid Waste Disposal and Diversion" (1360-4)
X 10D
PTFI
DIVISION 26 - ELECTRICAL
24 26 05 19 Low-Voltage Eletrical Power Conductors and Cables - 2.1 Conductors and Cables X 30D
PTSW
25 26 05 19 Low-Voltage Eletrical Power Conductors and Cables - 2.2 Connectors and Splices X 30D
PTSW
26 26 05 33 Raceways/Boxes/Wiring Devices for Electrical Systems - 2.1 Metal Conduits and Fittings X 30D
PTSW
26 05 33 Raceways/Boxes/Wiring Devices for Electrical Systems - 2.2 Nonmetalic Conduits and Fittings
X 30D
PTSW
26 05 33 Raceways/Boxes/Wiring Devices for Electrical Systems - 2.3 Handholes and Boxes for Exterior Underground Wiring
X 30D
PTSW
AF Form 66 02_24-6000 Submittal Schedule-1/15/2025
01330a-3
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE,
TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
APPROVED
DIS-
APPRO
VED
Number of Copies Required
NZAS 24-6000 MAF Lagoon Electrical
DATE CONTRACTOR
NOTIFIED
26 05 33 Raceways/Boxes/Wiring Devices for Electrical Systems - 2.3 Handholes and Boxes for Exterior Underground Wiring
X 30D
PTSW
30 26 05 33 Raceways/Boxes/Wiring Devices for Electrical Systems - 2.5 Receptacles X 30D
PTSW
31 26 05 53 Identification for Electrical Systems - 2.1 Power and Control Cable Identification Materials X 30D
PTSW
32 26 05 53 Identification for Electrical Systems - 2.2 Conductor Identification Materials X 30D
PTSW
33 26 05 53 Identification for Electrical Systems - 2.3 Underground-Line Warning Tape X 30D
PTSW
34 26 05 53 Identification for Electrical Systems - 2.4 Equipment Identification Labels X 30D
PTSW
35 26 05 53 Identification for Electrical Systems - 2.5 Cable Ties X 30D
PTSW
36 26 24 16 Panelboards - 1.3, 2.1, 2.2 Panel Board Product Data X 30D
PTSW
37 26 24 16 Panelboards - 2.2.D Branch Overcurrent Protecive Devices: Breaker Product Data X 30D
PTSW
38 26 24 16 Panelboards - 2.3 Disconnecting and Overcurrent Prootecive Devices X 30D
PTSW
DIVISION 03 - CAST-IN-PLACE
CONCRETE
39 03 30 00 CAST-IN-PLACE CONCRETE - 2.1
Formwork X X 30D
PTSW
AF Form 66 02_24-6000 Submittal Schedule-1/15/2025
01330a-4
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE,
TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
APPROVED
DIS-
APPRO
VED
Number of Copies Required
NZAS 24-6000 MAF Lagoon Electrical
DATE CONTRACTOR
NOTIFIED
40 03 30 00 CAST-IN-PLACE CONCRETE - 2.6
Concrete Mix Design X X 30D
PTSW
DIVISION 31 - EARTHWORK
31 23 33 Trench Excavation and Backfill for Pipelines & Appurtenant Structures - 1.3 Material Submittals
X 30D
PTSW
31 23 33 Trench Excavation and Backfill for Pipelines & Appurtenant Structures - 3.1.F Exploritory Excavation Method
X 30D
PTSW
DIVISION 32 - EXTERIOR
IMPROVEMENTS
43 32 92 19 - Seeding - 1.2.A, 2.1 - Seed Mixture X 30D
PTSW
44 32 92 19 - Seeding - 1.2.B - Seeding Application and Application Rate X 30D
PTSW
45 32 92 19 - Seeding - 2.3 - Fertilizer X 30D
PTSW
AFI = After Final Inspection BD= Before Delivery
ANP= After Notice to Proceed PTB= Prior To Bid
ATT= After Test Taken PTE=Prior to Event
AE= After Event PTFI= Prior to Final Inspection
BBCW=Before Beginning Concrete Work PTSW= Prior to Start of Work
Schedule of Abbreviations:
AF Form 66 02_24-6000 Submittal Schedule-1/15/2025
01330a-5
Text1: FA4626-XX-X-XXXX
File details come from the government source that posted it. Updated .