This document is a Contract Repair Screening Analysis Worksheet related to a federal contract opportunity for the repair of circuit card assemblies, power supply, and electronic components for the JETCAL® Analyzer and Environmental Control System Tester.
The key details are:
- NSN 5998-01-300-9618 circuit card assembly, part number BH26573-1, with an annual repair quantity of 1 and latest repair cost of $3,788.00
- The government does not own the data or rights to the data needed to contract repair from additional sources, and it has been determined uneconomical to buy the data or reverse engineer the part
- Howell Instruments, Inc. is the approved/potential source for this item, with a CAGE code of 98869
- The solicitation number is FA8517 and the government agency is the Department of the Air Force Materiel Command Air Force Sustainment Center
- The government is conducting market research to identify potential sources with the necessary data to repair the listed components.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CDRL Package 24-00039 appr2.pdf | ||
| 010877775 - 762.pdf | ||
| 012761968 - 762.pdf | ||
| RFI PR FD20602400039.pdf | ||
| 015866003 762.pdf | ||
| 010722441 - 762.pdf | ||
| 013656058 - 762.pdf | ||
| 010722412 - 762.pdf | ||
| PWS.pdf | ||
| 013009619 - 762.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
PART I (To be completed by PMS Seller)
1. FORM INITIATION DATE
06 MAR 2024
2. FORM PRIORITY
3. NSN
5998013009618JX
4. PART NUMBER
BH26573-1
5. PART NUMBER CAGE CODE
98869
6. NOUN
CIRCUIT CARD ASSEMB
7. ANNUAL REPAIR
QUANTITY
8. LATEST REPAIR COST
$3,788.0000
9. ANNUAL REPAIR
BUDGET VALUE
$3,788.00
10. FORECAST UNIT
PRICE
$9,728.3400
11. ERRC
T
12. WEAPON SYSTEM
Jet Engine Test Cell, various models
13. END ITEM APPLICATION
JETCAL Analyzer
14. HISTORY
DOES ORGANIC REPAIR OR DMISA REPAIR CAPABILITY CURRENTLY EXIST? X NO YES (if yes, specify SOR)
HAS THE ITEM PREVIOUSLY BEEN CONTRACT REPAIRED?
IF YES, COMPLETE TABLE BELOW FOR LAST 5 YEARS (not to exceed last 3 contracts)
NO X YES
SOURCE NAME CAGE CONTRACT NUMBER AWARD DATE
HOWELL INSTRUMENTS, INC. 28 JUN 202198869 FA851721F0037
HOWELL INSTRUMENTS, INC. 19 MAY 201498869 FA851714D00030001
HOWELL INSTRUMENTS, INC. 17 JUN 201198869 FA851711D00060001
15. PMS SELLER NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART II (To be completed by Equipment Specialist)
16. TECHNICAL ORDERS REQUIRED X NO YES (annotate required data and availability on RDL) UNKNOWN
17. OTHER SPECIFICATIONS / SPECIAL REPAIR CRITERIA REQUIRED NO YES (annotate required data and availability on RDL) X UNKNOWN
18. X THE DATA LISTED IN RDL COMPLETED SPECIFIES THE REPAIR REQUIREMENTS OR
ADDITIONAL DATA IS REQUIRED (Coordinate with the engineer and screening office to determine information required. Document in Block 33)
19. SPECIAL TOOL / SPECIAL TEST EQUIPMENT IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE
SPECIAL FACILITIES ARE X NOT REQUIRED REQUIRED
GOVERNMENT FURNISHED MATERIAL IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE
20. EQUIPMENT SPECIALIST NAME
King, Oscar L
CODE
OC
OFFICE SYMBOL
410 SCMS / GULB
PHONE
478-222-1393
COMPLETION DATE
08 MAR 2024
PART III (To be completed by Screening Technician if applicable)
21. REQUESTED ENGINEERING DATA
LISTED AND ANNOTATED ON RDL NO DATA
22. SCREENING TECHNICIAN REMARKS
23. SCREENING TECHNICIAN NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART IV (To be completed by the Engineer)
24. CRITICAL SAFETY ITEM
X NO YES
25. CAN THIS ITEM BE COMMERCIALLY
OVERHAULED / REPAIRED (FAR Part 12)
NO X YES
26. PRECONTRACT QUALIFICATION
REQUIRED
X NO YES (JQR/QR, SQS, Waiver)
27. RDL REQUIRED FOR
SOLICITATION
X NO YES
28. RMC / RMSC CODE
R3 / R
29. RMC / RMSC EXPIRATION DATE
07 MAR 2030
30. REASON FOR OTHER THAN G CODE AND ACTION TO REMEDY
The Government does not own the data or the rights to the data needed to contract repair of this part from additional sources. It has been determined to be uneconomical to buy the data or rights to the data. It is uneconomical to reverse engineer the part.
31. APPROVED / POTENTIAL SOURCES
CAGE
CODE DATE APPROVED
HOWELL INSTRUMENTS, INC. 98869
Page 1 of 2AFMC FORM 762, 20060201, V1 Version 8Generated by PRPS using Jasper Reports on 12 Mar 2024
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
32. ENGINEER NAME
Tobias, Mario A
CODE
N/A
OFFICE SYMBOL
410 SCMS / GUEA
PHONE
478-222-0023
COMPLETION DATE
08 MAR 2024
PART V (Miscellaneous, if needed)
33. REMARKS (Remarks require Functional Responsibility / Name / Office Symbol / Phone)
Page 2 of 2AFMC FORM 762, 20060201, V1 Version 8Generated by PRPS using Jasper Reports on 12 Mar 2024
File details come from the government source that posted it. Updated .