This document is a draft Attachment A - Schedule of Supplies for a Western Area Power Administration (WAPA) contract for disconnect switches across multiple voltage ranges (15.5-kV to 245-kV). The schedule details specific technical requirements for vertical break disconnecting switches, grounding air switches, and disconnect/grounding switch combinations, with detailed specifications for each voltage class including amperage ratings, Basic Impulse Level (BIL), phase configurations, operator types, and seismic qualification levels (moderate and high).
The contract includes line items for switches ranging from 15.5-kV to 245-kV, with each voltage class having multiple configuration options such as 1200A, 2000A, 3000A, and 4000A ratings. Additional line items cover cost adders for grounding blades, operator upgrades (manual worm-gear or motor-operated), auxiliary switches, spare parts, and high contamination creepage requirements. Key technical characteristics include group-operated switches, swing handle operators, minimum elevation ratings of 3,300 feet, and compliance with IEEE-693 seismic standards. Shipping is noted as FOB Destination, with WAPA handling unloading, and unit prices explicitly stated as not including shipping, delivery, or unloading costs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 004. DRAFT Attachment B - Technical Specifications.docx | DOCX document | |
| 004. DRAFT Attachment D - Regional Coverage Map.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRICE_SCHED
Moderate and High Seismic Disconnect Switches Schedule of Supplies
| CLIN | |
| Sub-Category | Disconnect Switch Sub-Category |
| 11000 | 15.5-kV Disconnect Switch, Grounding Air Switch, and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 11001 | Vertical Break Disconnecting Switch, Aluminum, 15.5-kV, 1200A, 110-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation. | EA | ||
| 11002 | Vertical Break Disconnecting Switch, Aluminum, 15.5-kV, 2000A, 110-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation. | EA | ||
| 11003 | Vertical Break Disconnecting Switch, Aluminum, 15.5-kV, 3000A, 110-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation. | EA | ||
| 11004 | This PSIN reserved for future use | |||
| 11005 | This PSIN reserved for future use | |||
| 11006 | Low Bus Support Structure, Horizontal Mounting, | |||
| High Seismic-IEEE-693 | EA | |||
| 11007 | High Bus Support Structure, Horizontal Mounting, | |||
| High Seismic-IEEE-693 | EA | |||
| 11008 | This PSIN reserved for future use | |||
| 11009 | Cost adder to include Grounding Blades to PSINs 11001, 3-Phase, Group Operated, 99-kA Peak Withstand Current, 110-kV BIL, Swing Handle Operator. | EA | ||
| 11010 | Cost adder to include Grounding Blades to PSINs 11002, 11003, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 110-kV BIL, Swing Handle Operator. | EA | ||
| 11011 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect Switch) | SET | ||
| 11012 | This PSIN reserved for future use | |||
| 11013 | Cost adder to upgrade to Manual Worm-Gear operator for PSINs 11001, 11002, 11003, 11009, 11010 | EA | ||
| 11014 | Cost adder to upgrade to Motor-Operator for PSINs 11001, 11002, 11003, 11009, 11010 | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 11015 | External Auxiliary Switch | EA | ||
| 11016 | This PSIN reserved for future use | |||
| 11017 | Spare Insulator, 110-kV, for use with 11001, 11002, 11003 | EA | ||
| 11018 | Basic Spare Parts set for PSIN 11001 | SET | ||
| 11019 | Basic Spare Parts set for PSIN 11002 | SET | ||
| 11020 | Basic Spare Parts set for PSIN 11003 | SET | ||
| 11021 | Motor Operator Spare Parts for PSIN 11014 | SET | ||
| 11023 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| Note: WAPA Will Unload. Shipping is FOB Destination. | ||||
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
| 12000 | 27-kV Disconnect Switch and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 12001 | Vertical Break Disconnecting Switch, Aluminum, 27-kV, 1200A, 150-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation. | EA | ||
| 12002 | Vertical Break Disconnecting Switch, Aluminum, 27-kV, 2000A, 150-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation. | EA | ||
| 12003 | Vertical Break Disconnecting Switch, Aluminum, 27-kV, 3000A, 150-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation. | EA | ||
| 12004 | Vertical Break Disconnecting Switch, Aluminum, 27-kV, 4000A, 150-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation. | EA | ||
| 12005 | This PSIN reserved for future use | |||
| 12006 | Low Bus Support Structure, Horizontal Mounting, High Seismic-IEEE-693 | EA | ||
| 12007 | High Bus Support Structure, Horizontal Mounting, High Seismic-IEEE-693 | EA | ||
| 12008 | This PSIN reserved for future use | |||
| 12009 | Cost adder to include Grounding Blades to PSINs 12001, 3-Phase, Group Operated, 99-kA Peak Withstand Current, 150-kV BIL, Swing Handle Operator. | EA | ||
| 12010 | Cost adder to include Grounding Blades to PSINs 12002, 12003, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 150-kV BIL, Swing Handle Operator. | EA | ||
| 12011 | Cost adder to include Grounding Blades to PSINs 12004, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 150-kV BIL, Swing Handle Operator. | EA | ||
| 12012 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect switch) | SET | ||
| 12013 | This PSIN reserved for future use | |||
| 12014 | Cost adder to upgrade to Manual Worm-Gear operator for PSINs 12001, 12002, 12003, 12004, 12009, 12010, 12011 | EA | ||
| 12015 | Cost adder to upgrade to Motor-Operator for PSINs 12001, 12002, 12003, 12004, 12009, 12010, 12011 | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 12016 | External Auxiliary Switch | EA | ||
| 12017 | This PSIN reserved for future use | |||
| 12018 | This PSIN reserved for future use | |||
| 12019 | Spare Insulator, 150-kV, for use with 12001, 12002, 12003, 12004 | EA | ||
| 12020 | Basic Spare Parts set for PSIN 12001 | SET | ||
| 12021 | Basic Spare Parts set for PSIN 12002 | SET | ||
| 12022 | Basic Spare Parts set for PSIN 12003 | SET | ||
| 12023 | Basic Spare Parts set for PSIN 12004 | SET | ||
| 12024 | Motor Operator Spare Parts for PSIN 12015 | SET | ||
| 12025 | This PSIN reserved for future use | |||
| 12026 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| 12027 | This PSIN reserved for future use | |||
| 12028 | This PSIN reserved for future use | |||
| 12029 | This PSIN reserved for future use | |||
| 12030 | This PSIN reserved for future use |
| Note: WAPA Will Unload. Shipping is FOB Destination. |
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
| 13000 | 38-kV Disconnect Switch and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 13001 | Vertical Break Disconnecting Switch, Aluminum, 38-kV, 1200A, 200-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693 | EA | ||
| 13002 | Vertical Break Disconnecting Switch, Aluminum, 38-kV, 2000A, 200-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693 | EA | ||
| 13003 | Vertical Break Disconnecting Switch, Aluminum, 38-kV, 3000A, 200-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693 | EA | ||
| 13004 | Vertical Break Disconnecting Switch, Aluminum, 38-kV, 4000A, 200-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693 | EA | ||
| 13005 | This PSIN reserved for future use | |||
| 13006 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSINs 13001, 13002, 13003, 13004 | EA | ||
| 13007 | This PSIN reserved for future use | |||
| 13008 | Low Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 13009 | High Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 13010 | Low Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 13011 | High Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 13012 | This PSIN reserved for future use | |||
| 13013 | Cost adder to include Grounding Blades to PSINs 13001, 3-Phase, Group Operated, 99-kA Peak Withstand Current, 200-kV BIL, Swing Handle Operator, Moderate Seismic-IEEE 693. | EA | ||
| 13014 | Cost adder to include Grounding Blades to PSINs 13002, 13003, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 200-kV BIL, Swing Handle Operator, Moderate Seismic-IEEE 693. | EA | ||
| 13015 | Cost adder to include Grounding Blades to PSINs 13004, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 200-kV BIL, Swing Handle Operator, Moderate Seismic-IEEE 693. | EA | ||
| 13016 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect switch) | SET | ||
| 13017 | This PSIN reserved for future use | |||
| 13018 | Cost adder to upgrade grounding switch to High Seismic-IEEE 693 for PSINs 13013, 13014, 13015 | EA | ||
| 13019 | This PSIN reserved for future use | |||
| 13020 | Cost adder to upgrade to Manual Worm-Gear operator for PSINs 13001, 13002, 13003, 13004, 13013, 13014, 13015 | EA | ||
| 13021 | Cost adder to upgrade to Motor-Operator for PSINs 13001, 13002, 13003, 13004, 13013, 13014, 13015 | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 13022 | External Auxiliary Switch | EA | ||
| 13023 | This PSIN reserved for future use | |||
| 13024 | This PSIN reserved for future use | |||
| 13025 | Spare Insulator, 200-kV, for use with 13001, 13002, 13003, 13004 | EA | ||
| 13026 | Basic Spare Parts set for PSIN 13001 | SET | ||
| 13027 | Basic Spare Parts set for PSIN 13002 | SET | ||
| 13028 | Basic Spare Parts set for PSIN 13003 | SET | ||
| 13029 | Basic Spare Parts set for PSIN 13004 | SET | ||
| 13030 | Motor Operator Spare Parts for PSIN 13021 | SET | ||
| 13031 | This PSIN reserved for future use | |||
| 13032 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| 13033 | This PSIN reserved for future use | |||
| Note: WAPA Will Unload. Shipping is FOB Destination. | ||||
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
| 14000 | 48.3-kV Disconnect Switch, and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 14001 | Vertical Break Disconnecting Switch, Aluminum, 48.3-kV, 1200A, 250-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 14002 | Vertical Break Disconnecting Switch, Aluminum, 48.3-kV, 2000A, 250-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 14003 | Vertical Break Disconnecting Switch, Aluminum, 48.3-kV, 3000A, 250-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 14004 | Vertical Break Disconnecting Switch, Aluminum, 48.3-kV, 4000A, 250-kV BIL, 3-Phase, Group Operated, Swing Handle Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 14005 | This PSIN reserved for future use | |||
| 14006 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSINs 14001, 14002, 14003, 14004 | EA | ||
| 14007 | This PSIN reserved for future use | |||
| 14008 | Low Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 14009 | High Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 14010 | Low Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 14011 | High Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 14012 | This PSIN reserved for future use | |||
| 14013 | Cost adder to include Grounding Blades to PSINs 14001, 3-Phase, Group Operated, 99-kA Peak Withstand Current, 250-kV BIL, Swing Handle Operator. | EA | ||
| 14014 | Cost adder to include Grounding Blades to PSINs 14002, 14003, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 250-kV BIL, Swing Handle Operator. | EA | ||
| 14015 | Cost adder to include Grounding Blades to PSINs 14004, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 250-kV BIL, Swing Handle Operator. | EA | ||
| 14016 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect switch) | SET | ||
| 14017 | This PSIN reserved for future use | |||
| 14018 | Cost adder to upgrade grounding switch to High Seismic-IEEE 693 for PSINs 14013, 14014, 14015 | EA | ||
| 14019 | This PSIN reserved for future use | |||
| 14020 | Cost adder to upgrade to Manual Worm-Gear operator for PSINs 14001, 14002, 14003, 14004, 14013, 14014, 14015 | EA | ||
| 14021 | Cost adder to upgrade to Motor-Operator for PSINs 14001, 14002, 14003, 14004, 14013, 14014, 14015 | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 14022 | External Auxiliary Switch | EA | ||
| 14023 | This PSIN reserved for future use | |||
| 14024 | This PSIN reserved for future use | |||
| 14025 | Spare Insulator, 250-kV, for use with 14001, 14002, 14003, 14004 | EA | ||
| 14026 | Basic Spare Parts set for PSIN 14001 | SET | ||
| 14027 | Basic Spare Parts set for PSIN 14002 | SET | ||
| 14028 | Basic Spare Parts set for PSIN 14003 | SET | ||
| 14029 | Basic Spare Parts set for PSIN 14004 | SET | ||
| 14030 | Motor Operator Spare Parts for PSIN 14021 | SET | ||
| 14031 | This PSIN reserved for future use | |||
| 14032 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| Note: WAPA Will Unload. Shipping is FOB Destination. | ||||
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
| 15000 | 72.5-kV Disconnect Switch, Grounding Air Switch, and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 15001 | Vertical Break Disconnecting Switch, Aluminum, 72.5-kV, 2000A, 350-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 15002 | Vertical Break Disconnecting Switch, Aluminum, 72.5-kV, 3000A, 350-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 15003 | Vertical Break Disconnecting Switch, Aluminum, 72.5-kV, 4000A, 350-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 15004 | Vertical Break Disconnecting Switch, Aluminum, 72.5-kV, 2000A, 350-kV BIL, 1-Phase, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 15005 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSINs 15001, 15002, 15003 | EA | ||
| 15006 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSIN 15004 | EA | ||
| 15007 | Low Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 15008 | High Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 15009 | Low Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 15010 | High Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 15011 | This PSIN reserved for future use | |||
| 15012 | Cost adder to include Grounding Blades to PSINs 15001, 15002, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 350-kV BIL, Manual Worm-Gear Operator, Moderate Seismic-IEEE 693. | EA | ||
| 15013 | Cost adder to include Grounding Blades to PSINs 15003, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 350-kV BIL, Manual Worm-Gear Operator, Moderate Seismic-IEEE 693. | EA | ||
| 15014 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 72.5-kV, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 15015 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 72.5-kV, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, minimum 3,300 feet elevation, High Seismic-IEEE 693. | EA | ||
| 15016 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect switch) | SET | ||
| 15017 | This PSIN reserved for future use | |||
| 15018 | Cost adder to upgrade grounding switch to High Seismic-IEEE 693 for PSINs 15012, 15013 | EA | ||
| 15019 | This PSIN reserved for future use | |||
| 15020 | Cost adder to upgrade to Motor-Operator for PSINs 15001, 15002, 15003, 15012, 15013, 15014, 15015. | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 15021 | External Auxiliary Switch | EA | ||
| 15022 | This PSIN reserved for future use | |||
| 15023 | This PSIN reserved for future use | |||
| 15024 | Spare Insulator, 350-kV, for use with 15001, 15002, 15003 | EA | ||
| 15025 | Basic Spare Parts set for PSIN 15001 | SET | ||
| 15026 | Basic Spare Parts set for PSIN 15002 | SET | ||
| 15027 | Basic Spare Parts set for PSIN 15003 | SET | ||
| 15028 | Spare Worm Gear Operator for use with PSINs 15001, 15002, 15003, 15004, 15012, 15013, 15014, 15015 | EA | ||
| 15029 | Motor Operator Spare Parts for PSIN 15020 | SET | ||
| 15030 | This PSIN reserved for future use | |||
| 15031 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| 15032 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 15033 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 15034 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 15035 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 15036 | This PSIN reserved for future use | EA | ||
| 15037 | This PSIN reserved for future use | EA | ||
| 15038 | This PSIN reserved for future use | EA | ||
| 15039 | This PSIN reserved for future use | EA | ||
| 15040 | Interrupter, Vacuum, Three-Phase, 2,000A, for use with PSIN 15001 | SET | ||
| 15041 | Interrupter, Vacuum, Three-Phase, 3,000A, for use with PSIN 15002 | SET | ||
| 15042 | Interrupter, Vacuum, Single-Phase, 2,000A, for use with PSIN 15004 | EA | ||
| 15043 | Interrupter, SF6, Three-Phase, 2,000A, for use with PSIN 15001 | SET | ||
| 15044 | Interrupter, SF6, Three-Phase, 3,000A, for use with PSIN 15002 | SET | ||
| 15045 | Interrupter, SF6, Single-Phase, 2,000A, for use with PSIN 15004 | EA | ||
| 15046 | This PSIN reserved for future use | EA | ||
| 15047 | This PSIN reserved for future use | EA | ||
| 15048 | This PSIN reserved for future use | EA | ||
| 15049 | This PSIN reserved for future use | EA | ||
| 15050 | This PSIN reserved for future use | EA | ||
| 15051 | This PSIN reserved for future use | EA | ||
| 15052 | This PSIN reserved for future use | EA | ||
| 15053 | This PSIN reserved for future use | EA | ||
| 15054 | This PSIN reserved for future use | EA | ||
| 15055 | This PSIN reserved for future use | EA | ||
| 15056 | This PSIN reserved for future use | EA | ||
| 15057 | This PSIN reserved for future use | EA | ||
| 15058 | This PSIN reserved for future use | EA | ||
| 15059 | This PSIN reserved for future use | EA | ||
| 15060 | This PSIN reserved for future use | EA | ||
| Note: WAPA Will Unload. Shipping is FOB Destination. | ||||
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
| 16000 | 123-kV Disconnect Switch, Grounding Air Switch, and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 16001 | Vertical Break Disconnecting Switch, Aluminum, 123-kV, 2000A, 550-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 16002 | Vertical Break Disconnecting Switch, Aluminum, 123-kV, 3000A, 550-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 16003 | Vertical Break Disconnecting Switch, Aluminum, 123-kV, 4000A, 550-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 16004 | Vertical Break Disconnecting Switch, Aluminum, 123-kV, 2000A, 550-kV BIL, 1-Phase, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 16005 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSINs 16001, 16002, 16003 | EA | ||
| 16006 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSIN 16004 | EA | ||
| 16007 | Low Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 16008 | High Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 16009 | Low Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 16010 | High Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 16011 | This PSIN reserved for future use | |||
| 16012 | Cost adder to include Grounding Blades to PSINs 16001, 16002, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 550-kV BIL, Manual Worm-Gear Operator. | EA | ||
| 16013 | Cost adder to include Grounding Blades to PSINs 16003, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 550-kV BIL, Manual Worm-Gear Operator. | EA | ||
| 16014 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 123-kV, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 16015 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 123-kV, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, minimum 3,300 feet elevation, High Seismic-IEEE 693. | EA | ||
| 16016 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect switch) | SET | ||
| 16017 | This PSIN reserved for future use | |||
| 16018 | Cost adder to upgrade grounding switch to High Seismic-IEEE 693 for PSINs 16012, 16013 | EA | ||
| 16019 | This PSIN reserved for future use | |||
| 16020 | Cost adder to upgrade to Motor-Operator for PSINs 16001, 16002, 16003, 16012, 16013, 16014, 16015 | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 16021 | External Auxiliary Switch | EA | ||
| 16022 | This PSIN reserved for future use | |||
| 16023 | This PSIN reserved for future use | |||
| 16024 | Spare Insulator, 550-kV, for use with 16001, 16002, 16003, | EA | ||
| 16025 | Basic Spare Parts set for PSIN 16001 | SET | ||
| 16026 | Basic Spare Parts set for PSIN 16002 | SET | ||
| 16027 | Basic Spare Parts set for PSIN 16003 | SET | ||
| 16028 | Spare Worm Gear Operator for use with PSINs 16001, 16002, 16003, 16004, 16012, 16013, 16014, 16015 | EA | ||
| 16029 | Motor Operator Spare Parts for PSIN 16020 | SET | ||
| 16030 | This PSIN reserved for future use | |||
| 16031 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| 16032 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 16033 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 16034 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 16035 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 16036 | This PSIN reserved for future use | |||
| 16037 | This PSIN reserved for future use | |||
| 16038 | This PSIN reserved for future use | |||
| 16039 | This PSIN reserved for future use | |||
| 16040 | Interrupter, Vacuum, Three-Phase, 2,000A, for use with PSIN 16001 | SET | ||
| 16041 | Interrupter, Vacuum, Three-Phase, 3,000A, for use with PSIN 16002 | SET | ||
| 16042 | Interrupter, Vacuum, Single-Phase, 2,000A, for use with PSIN 16004 | EA | ||
| 16043 | Interrupter, SF6, Three-Phase, 2,000A, for use with PSIN 16001 | SET | ||
| 16044 | Interrupter, SF6, Three-Phase, 3,000A, for use with PSIN 16002 | SET | ||
| 16045 | Interrupter, SF6, Single-Phase, 2,000A, for use with PSIN 16004 | EA | ||
| 16046 | This PSIN reserved for future use | |||
| 16047 | This PSIN reserved for future use | |||
| 16048 | This PSIN reserved for future use | |||
| 16049 | This PSIN reserved for future use | |||
| 16050 | This PSIN reserved for future use | |||
| 16051 | This PSIN reserved for future use | |||
| 16052 | This PSIN reserved for future use | |||
| Note: WAPA Will Unload. Shipping is FOB Destination. | ||||
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
| 17000 | 145-kV Disconnect Switch, Grounding Air Switch, and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 17001 | Vertical Break Disconnecting Switch, Aluminum, 145-kV, 2000A, 650-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 17002 | Vertical Break Disconnecting Switch, Aluminum, 145-kV, 3000A, 650-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 17003 | Vertical Break Disconnecting Switch, Aluminum, 145-kV, 4000A, 650-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 17004 | Vertical Break Disconnecting Switch, Aluminum, 145-kV, 2000A, 650-kV BIL, 1-Phase, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 17005 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSINs 17001, 17002, 17003 | EA | ||
| 17006 | This PSIN reserved for future use | |||
| 17007 | Low Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 17008 | High Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 17009 | Low Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 17010 | High Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 17011 | This PSIN reserved for future use | |||
| 17012 | Cost adder to include Grounding Blades to PSINs 17001, 17002, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 650-kV BIL, Manual Worm-Gear Operator. | EA | ||
| 17013 | Cost adder to include Grounding Blades to PSINs 17003, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 650-kV BIL, Manual Worm-Gear Operator. | EA | ||
| 17014 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 145-kV, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 17015 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 145-kV, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, minimum 3,300 feet elevation, High Seismic-IEEE 693. | EA | ||
| 17016 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect switch) | SET | ||
| 17017 | This PSIN reserved for future use | |||
| 17018 | Cost adder to upgrade grounding switch to High Seismic-IEEE 693 for PSINs 17012, 17013 | EA | ||
| 17019 | This PSIN reserved for future use | |||
| 17020 | Cost adder to upgrade to Motor-Operator for PSINs 17001, 17002, 17003, 17012, 17013, 17014, 17015 | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 17021 | External Auxiliary Switch | EA | ||
| 17022 | This PSIN reserved for future use | |||
| 17023 | This PSIN reserved for future use | |||
| 17024 | Spare Insulator, 650-kV, for use with 17001, 17002, 17003 | EA | ||
| 17025 | Basic Spare Parts set for PSIN 17001 | SET | ||
| 17026 | Basic Spare Parts set for PSIN 17002 | SET | ||
| 17027 | Basic Spare Parts set for PSIN 17003 | SET | ||
| 17028 | Spare Worm Gear Operator for use with PSINs 17001, 17002, 17003, 17012, 17013, 17014, 17015 | EA | ||
| 17029 | Motor Operator Spare Parts for PSIN 17020 | SET | ||
| 17030 | This PSIN reserved for future use | |||
| 17031 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| 17032 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 17033 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 17034 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 17035 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 17036 | This PSIN reserved for future use | |||
| 17037 | This PSIN reserved for future use | |||
| 17038 | This PSIN reserved for future use | |||
| 17039 | This PSIN reserved for future use | |||
| 17040 | Interrupter, Vacuum, Three-Phase, 2,000A, for use with PSIN 17001 | SET | ||
| 17041 | Interrupter, Vacuum, Three-Phase, 3,000A, for use with PSIN 17002 | SET | ||
| 17042 | This PSIN reserved for future use | |||
| 17043 | Interrupter, SF6, Three-Phase, 2,000A, for use with PSIN 17001 | SET | ||
| 17044 | Interrupter, SF6, Three-Phase, 3,000A, for use with PSIN 17002 | SET | ||
| 17045 | This PSIN reserved for future use | |||
| 17046 | This PSIN reserved for future use | |||
| 17047 | This PSIN reserved for future use | |||
| 17048 | This PSIN reserved for future use | |||
| 17049 | This PSIN reserved for future use | |||
| 17050 | This PSIN reserved for future use | |||
| Note: WAPA Will Unload. Shipping is FOB Destination. | ||||
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
| 18000 | 170-kV Disconnect Switch, Grounding Air Switch, and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 18001 | Vertical Break Disconnecting Switch, Aluminum, 170-kV, 2000A, 750-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 18002 | Vertical Break Disconnecting Switch, Aluminum, 170-kV, 3000A, 750-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 18003 | Vertical Break Disconnecting Switch, Aluminum, 170-kV, 4000A, 750-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 18004 | Vertical Break Disconnecting Switch, Aluminum, 170-kV, 2000A, 750-kV BIL, 1-Phase, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 18005 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSINs 18001, 18002, 18003 | EA | ||
| 18006 | This PSIN reserved for future use | |||
| 18007 | Low Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 18008 | High Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 18009 | Low Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 18010 | High Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 18011 | This PSIN reserved for future use | |||
| 18012 | Cost adder to include Grounding Blades to PSINs 18001, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 750-kV BIL, Manual Worm-Gear Operator. | EA | ||
| 18013 | Cost adder to include Grounding Blades to PSINs 18002, 18003, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 750-kV BIL, Manual Worm-Gear Operator. | EA | ||
| 18014 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 170-kV, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 18015 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 170-kV, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, minimum 3,300 feet elevation, High Seismic-IEEE 693. | EA | ||
| 18016 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect switch) | SET | ||
| 18017 | This PSIN reserved for future use | |||
| 18018 | Cost adder to upgrade grounding switch to High Seismic-IEEE 693 for PSINs 18012, 18013 | EA | ||
| 18019 | This PSIN reserved for future use | |||
| 18020 | Cost adder to upgrade to Motor-Operator for PSINs 18001, 18002, 18003, 18012, 18013, 18014, 18015 | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 18021 | External Auxiliary Switch | EA | ||
| 18022 | This PSIN reserved for future use | |||
| 18023 | This PSIN reserved for future use | |||
| 18024 | Spare Insulator, 750-kV, for use with 18001, 18002, 18003 | EA | ||
| 18025 | Basic Spare Parts set for PSIN 18001 | SET | ||
| 18026 | Basic Spare Parts set for PSIN 18002 | SET | ||
| 18027 | Basic Spare Parts set for PSIN 18003 | SET | ||
| 18028 | Spare Worm Gear Operator for use with PSINs 18001, 18002, 18003, 18012, 18013, 18014, 18015 | EA | ||
| 18029 | Motor Operator Spare Parts for PSIN 18020 | SET | ||
| 18030 | Cost Adder to upgrade all nine (9) insulators for Medium Contamination creepage requirements. | EA | ||
| 18031 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| 18032 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 18033 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 18034 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 18035 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 18036 | This PSIN reserved for future use | |||
| 18037 | This PSIN reserved for future use | |||
| 18038 | This PSIN reserved for future use | |||
| 18039 | This PSIN reserved for future use | |||
| 18040 | Interrupter, Vacuum, Three-Phase, 2,000A, for use with PSIN 18001 | SET | ||
| 18041 | Interrupter, Vacuum, Three-Phase, 3,000A, for use with PSIN 18002 | SET | ||
| 18043 | This PSIN reserved for future use | |||
| 18043 | Interrupter, SF6, Three-Phase, 2,000A, for use with PSIN 18001 | SET | ||
| 18044 | Interrupter, SF6, Three-Phase, 3,000A, for use with PSIN 18002 | SET | ||
| 18045 | This PSIN reserved for future use | EA | ||
| 18046 | This PSIN reserved for future use | |||
| 18047 | This PSIN reserved for future use | |||
| 18048 | This PSIN reserved for future use | |||
| 18049 | This PSIN reserved for future use | |||
| 18050 | This PSIN reserved for future use | |||
| Note: WAPA Will Unload. Shipping is FOB Destination. | ||||
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
| 19000 | 245-kV Disconnect Switch, Grounding Air Switch, and Disconnect/Grounding Switch Combinations | |||
| Contract Line Item Number | ||||
| (CLIN) | Supplies/Material Description | Qty | Unit | |
| 19001 | Vertical Break Disconnecting Switch, Aluminum, 245-kV, 2000A, 900-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 19002 | Vertical Break Disconnecting Switch, Aluminum, 245-kV, 3000A, 900-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 19003 | Vertical Break Disconnecting Switch, Aluminum, 245-kV, 4000A, 900-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 19004 | Vertical Break Disconnecting Switch, Aluminum, 245-kV, 2000A, 1050-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 8,000 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 19005 | Vertical Break Disconnecting Switch, Aluminum, 245-kV, 3000A, 1050-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 8,000 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 19006 | Vertical Break Disconnecting Switch, Aluminum, 245-kV, 4000A, 1050-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, minimum 8,000 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 19007 | This PSIN reserved for future use | |||
| 19008 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSINs 19001, 19002, 19003, 19004, 19005, 19006 | EA | ||
| 19009 | This PSIN reserved for future use | |||
| 19010 | Low Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 19011 | High Bus Support Structure, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 19012 | Low Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 19013 | High Bus Support Structure, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 19014 | This PSIN reserved for future use | |||
| 19015 | Cost adder to include Grounding Blades to PSINs 19001, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 900-kV BIL, Manual Worm-Gear Operator, Moderate Seismic-IEEE 693. | EA | ||
| 19016 | Cost adder to include Grounding Blades to PSINs 19002, 19003, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 900-kV BIL, Manual Worm-Gear Operator, Moderate Seismic-IEEE 693. | EA | ||
| 19017 | Cost adder to include Grounding Blades to PSINs 19004, 3-Phase, Group Operated, 164-kA Peak Withstand Current, 1050-kV BIL, Manual Worm-Gear Operator, Moderate Seismic-IEEE 693. | EA | ||
| 19018 | Cost adder to include Grounding Blades to PSINs 19005, 19006, 3-Phase, Group Operated, 195-kA Peak Withstand Current, 1050-kV BIL, Manual Worm-Gear Operator, Moderate Seismic-IEEE 693. | EA | ||
| 19019 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 245-kV, 900-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, Moderate Seismic-IEEE 693. | EA | ||
| 19020 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 245-kV, 900-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, High Seismic-IEEE 693. | EA | ||
| 19021 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 245-kV, 1050-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, Moderate Seismic-IEEE 693. | EA | ||
| 19022 | Vertical Break Free Standing Grounding Air Switch, Aluminum, 245-kV, 1050-kV BIL, 3-Phase, Group Operated, Manual Worm-Gear Operator, with support structure, High Seismic-IEEE 693. | EA | ||
| 19023 | Key Interlock Set (set equals 2 total. 1 for ground blade, 1 for adjacent disconnect switch) | SET | ||
| 19024 | This PSIN reserved for future use | |||
| 19025 | Cost adder to upgrade grounding switch to High Seismic-IEEE 693 for PSINs 19015, 19016 | EA | ||
| 19026 | Cost adder to upgrade grounding switch to High Seismic-IEEE 693 for PSINs 19017, 19018 | EA | ||
| 19027 | This PSIN reserved for future use | |||
| 19028 | Cost adder to upgrade to Motor-Operator for PSINs 19001, 19002, 19003, 19004, 19005, 19006, 19015, 19016, 19017, 19018, 19019, 19020, 19021, 19022 | |||
| Minimum Output 20,000 inch-pounds | EA | |||
| 19029 | External Auxiliary Switch | EA | ||
| 19030 | This PSIN reserved for future use | |||
| 19031 | This PSIN reserved for future use | |||
| 19032 | Spare Insulator, 900-kV, for use with 19001, 19002, 19003 | EA | ||
| 19033 | Spare Insulator, 1050-kV, for use with 19004, 19005, 19006 | EA | ||
| 19034 | Basic Spare Parts set for PSIN 19001 | SET | ||
| 19035 | Basic Spare Parts set for PSIN 19002 | SET | ||
| 19036 | Basic Spare Parts set for PSIN 19003 | SET | ||
| 19037 | Spare Worm Gear Operator for use with PSINs 19001, 19002, 19003, 19004, 19005, 19006, 19015, 19016, 19017, 19018, 19019, 19020, 19021, 19022 | EA | ||
| 19038 | Motor Operator Spare Parts for PSIN 19028 | SET | ||
| 19039 | This PSIN reserved for future use | |||
| 19040 | Cost Adder to upgrade all nine (9) insulators for Medium Contamination creepage requirements. | EA | ||
| 19041 | Cost Adder to upgrade all nine (9) insulators for High Contamination creepage requirements. | EA | ||
| 19042 | Vertical Break Disconnecting Switch, Aluminum, 245-kV, 2000A, 900-kV BIL, 1-Phase, Manual Worm-Gear Operator, minimum 3,300 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 19043 | Vertical Break Disconnecting Switch, Aluminum, 245-kV, 2000A, 1050-kV BIL, 1-Phase, Manual Worm-Gear Operator, minimum 8,000 feet elevation, Moderate Seismic-IEEE 693. | EA | ||
| 19044 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSIN 19042 | EA | ||
| 19045 | Cost adder to upgrade disconnect switch to High Seismic-IEEE 693 for PSIN 19043 | EA | ||
| 19046 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 19047 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, Moderate Seismic-IEEE 693 | EA | ||
| 19048 | Low Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 19049 | High Bus Support Structure For Single Phase Switch, Horizontal Mounting, High Seismic-IEEE 693 | EA | ||
| 19050 | Interrupter, Vacuum, Three-Phase, 2,000A, for use with PSIN 19001, 19004 | SET | ||
| 19051 | Interrupter, Vacuum, Three-Phase, 3,000A, for use with PSIN 19002, 19005 | SET | ||
| 19052 | Interrupter, Vacuum, Single-Phase, 2,000A, for use with PSIN 19042, 19043 | EA | ||
| 19053 | Interrupter, SF6, Three-Phase, 2,000A, for use with PSIN 19001, 19004 | SET | ||
| 19054 | Interrupter, SF6, Three-Phase, *3,000A, for use with PSIN 19002, 19005 | SET | ||
| 19055 | Interrupter, SF6, Single-Phase, 2,000A, for use with PSIN 19042, 19043 | EA | ||
| 19056 | This PSIN reserved for future use | |||
| 19057 | This PSIN reserved for future use | |||
| 19058 | This PSIN reserved for future use | |||
| 19059 | This PSIN reserved for future use | |||
| 19060 | This PSIN reserved for future use | |||
| 19061 | This PSIN reserved for future use | |||
| Note: WAPA Will Unload. Shipping is FOB Destination. | ||||
| Note to Buyer: |
Unit Prices Do not Include Shipping, Delivery, or Unloading.
Those prices are to be negotiated on a per order basis.
Note: *PSIN 19054 is rated 2,000A Load Breaking, 200A Line Dropping, 3,000A Loop Splitting as long as the transient recovery voltage (TRV) does not exceed 95 kV.
&"Arial,Bold"INDEPENDENT GOVERNMENT/ENGINEER'S COST ESTIMATE&"Arial,Regular"&10DE-RP65-07WN30380
&"Arial,Bold"INDEPENDENT GOVERNMENT/ENGINEER'S COST ESTIMATE&"Arial,Regular"&10DE-RP65-07WN30380
&10ATTACHMENT A - DELIVERY ORDER SPECIFICS
DSW DISCONNECT SWITCH IDIQ CONTRACT &KFF000089503120DWA000001
&K000000ROYAL SWITCHGEAR &KFF000007/01/2020 -07/31/2025
&K00B050MOD P00011-01/25/2024