This is a project plans document for a culvert repair project on Oregon State Route 82 (Wallowa Lake Highway) from Wallowa to Joseph in Wallowa County, prepared by the Oregon Department of Transportation. The project, numbered 59V-049, encompasses a 35.52-mile stretch of highway from mile post (MP) 32.39 to MP 67.91 and involves the repair, rehabilitation, and replacement of multiple culverts along the corridor. The scope of work includes removing and installing corrugated metal pipe (CMP) and concrete culverts ranging from 12 to 36 inches in diameter, installing culvert markers (Type 1 and Type 2), constructing Type D ditch inlets with Class 50 and Class 100 riprap inlet protection, implementing temporary water management features including plastic sandbag barriers, performing trench resurfacing and backfill operations, and applying permanent seeding to areas of soil disturbance. The project addresses multiple drainage facilities across various sections, with detailed work specifications provided for each of the 18 culvert locations identified in the plans.
The plans document includes comprehensive technical specifications and standard drawings referencing Oregon Department of Transportation standard details for drainage, signing, and roadside development. Work specifications address pipe bedding, trench backfill using Class A through E materials, coupling band installations for corrugated metal pipes, pipe-to-structure connections with non-shrink grout and tracer wire, and concrete inlet frames and grates. Special considerations noted include coordination with irrigation use, removal of utility conduits and standpipes, temporary water management during construction, and temporary water management facility upgrades for unexpected storm events. The design was prepared by registered professional engineer Wade Holaday and reviewed by Chris Diehl, with plans finalized in February 2026. The document emphasizes worker safety throughout all project phases and requires contractors to verify existing culvert lengths and conditions prior to rehabilitation work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 00016170 Preliminary Results.xlsx | XLSX spreadsheet | |
| 00016170 Attachment A Form A2 Pricing Form.xlsx | XLSX spreadsheet | |
| 00016170 Exhibit 5 Specifications.docx | DOCX document | |
| 00016170 Invitation To Bid.docx | DOCX document | |
| 00016170 Sample Contract.docx | DOCX document | |
| 00016170 Addendum 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADMINISTRATION
FEDERAL HIGHWAY
DIVISION
OREGON
PROJECT NUMBER
NO.
SHEET
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
STATE
DRAINAGE, SIGNING, & ROADSIDE DEVELOPMENT
59V-049
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
WALLOWA LAKE HIGHWAY
MARCH 2026
WALLOWA COUNTY
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
OR82: WALLOWA TO JOSEPH
CULVERT REPAIR PROJECT
SHEET NO. DESCRIPTION
HYDRAULICS
Standard Drg. Nos.
M C
M
PLANS FOR PROPOSED PROJECT
ST. HELENS
ASTORIA
TILLAMOOK
MCMINNVILLE
ALBANYNEWPORT
CORVALLIS
HOOD
RIVER
DALLES
THE
MADRAS
PRINEVILLE
BEND
COQUILLE
GRANTS
PASS
Ashland
BURNS
KLAMATH
FALLS
CONDON
MORO
PENDLETON
LA GRANDE
ENTERPRISE
VALE Ontario
PORTLAND
SALEM
MEDFORD
EUGENE
ROSEBURG
Athena
N. Powder
Unity Dayville
Sisters
Juntura
Frenchglen
Burns Jct.
McDermitt
Paisley
La Pine
Crescent
Biggs
Lexington
Hermiston Boardman
Ukiah
Arlington
Malin
Brookings
Coos Bay
Drain
Canyonvil le
Reedsport
Oakridge
Goshen Florence
Lincoln City
Waldport
Home Sweet
Detroit Antelope
Maupin
Forest Grove
Hebo
Cannon Beach
Seaside Rainier
Milton-Freewater
W
26 35 197
39519
3953197
Bonanza
Junction City
BAKER CITY
HEPPNER
Copperfield
Lake Silver
Junction CaveBEACH
GOLD
Orford Port
LAKEVIEW
CANYON
CITY
Day John
CITY
OREGON
HILLSBORO
DALLAS
Redmond
Val ley Jordan
STATE OF OREGON
DEPARTMENT OF TRANSPORTATION
ATTENTION:
The Oregon Utility Center Is (503) 232-1987.)
The Center. (Note: The Telephone Number For
You May Obtain Copies Of The Rules By Calling
OAR 952-001-0010 Through OAR 952-001-0090.
Center. Those Rules Are Set Forth In
Adopted By The Oregon Utility Notification
Oregon Law Requires You To Follow Rules
LET'S ALL
WORK TOGETHER
TO MAKE THIS
JOB SAFE
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
F
IR
S T
S A F E T Y
INDEX OF SHEETS
SHEET NO. DESCRIPTION
Title SheetA01
F
O T
N E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
- Tables, Abrupt Edges, and PCMS DetailsTM800
- Temporary Sign SupportsTM821
- 2-Lane, 2-Way RoadwaysTM850
ENTERPRISE
T. 01 N., R. 43 E., W.M.
T. 01 S., R. 43 E., W.M.
T. 01 S., R. 44 E., W.M.
Culverts HB10 incl.
HB01 thru
M.P. 32.39
OF PROJECT
BEGINNING
M.P. 67.91
END OF PROJECT
Overall Length Of Project - 35.52 Miles- Trench Backfill, Bedding, Pipe Zone And Multiple InstallationsRD300
- Temporary Sign SupportsTM822
- Intersection Work Zone DetailsTM841
- 2-Lane, 2-Way RoadwaysTM854
- 2-Lane, 2-Way RoadwaysTM855
WALLOWA
LOSTINE
HB11 Culvert Marker Details
- Street CutRD302
- Coupling Bands for Corrugated Metal PipeRD325
- Pipe to Structure ConnectionsRD339
- Concrete Inlets Type G-1, G-2, G-2M, and G-2MARD364
- Frames and Grates for Concrete InletsRD365
- Ditch Inlet Type DRD370
- Coupling Bands for Corrugated Metal PipeRD326
- Coupling Bands for Corrugated Metal PipeRD327
T. 02 S., R. 45 E., W.M.
T. 01 N., R. 42 E., W.M.
T. 02 N., R. 41 E., W.M.
- Traffic Delineators Steel Post DetailsTM571
A01
R_M24104_ts_01.dgn :: A01 2/9/2026 2:29:57 PM hwye56x
59V-049
CULVERTS
OREGON
RE
GI
ST
ERE
D PROFESSIONALEN
GINEER
51 99
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB01 2/9/2026 2:30:02 PM hwye56x
MP 32.39
Apply Permanent Seeding in areas of soil disturbance or as directed.
inlet in-line with upgrade ditch line.
be filled with class 50 riprap matching adjacent slopes. Place Type D in-line with existing culvert. Significant erosion of embankment to
Culvert inlet has vertical standpipe. Remove prior to extending inlet
Elevations are representative only.
Notes:
O R
Sec. 31, T.02 N., R.41 E., W.M.
E B
W B
OR82
Extg. ground 24" culvert
10 20 305 15 25
Type "D" inlet
Scale: 1"=5'
MP 32.39 PROFILE
RD339, RD364, RD365, & RD370)
(see dwg. nos. RD300, RD325, RD326, RD327, Inst. Class 50 riprap inlet protection - 10 CY
Const. type "D" inlet with 12" sump
Connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 24" CMP culv. pipe - 5'
Remove 24" culvert Lt. - 2'
24" CMP - 80' (In pl.)
(For details, see sht. HB11)
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Class 50 riprap
CULVERT ID MARKER TABLE
Check where appropriate
2 32.39
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
D041986
Type 1 marker
Conc. barrier
HB01
H_M24104_clpl_01.dgn :: HB01 2/9/2026 2:30:02 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB02 2/9/2026 2:30:02 PM hwye56x
CULVERT ID MARKER TABLE
Check where appropriate
3 48.14
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
6 48.83
D042053
D042054
MP 48.14
Sec. 13, T.01 N., R.42 E., W.M.
MP 48.83
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Regrade in area of culvert inlet to blend with adjacent slopes or as directed.
Note:
Type 1 marker
EB
WB
OR82
Regrade slope
Remove 4' Rt.
18" CMP - 70' (In pl.)
Rehabilitate extg. 18" culvert - 66'
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Notes:
OR82
WB
EB
Type 1 marker
(see dwg. no. RD302)
Trench resurf. - 5 sq. yd.
Match extg. grade
Match extg. material
5' depth
Inst. 18" CMP culv. pipe - 12'
Remove 12' Lt.
18" CMP - 54' (In pl.)
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 54'
Sec. 19, T.01 N., R.43 E., W.M.
HB02
H_M24104_clpl_01.dgn :: HB02 2/9/2026 2:30:02 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB03 2/9/2026 2:30:03 PM hwye56x
CULVERT ID MARKER TABLE
Check where appropriate
3 50.41
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
D041996
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
temporary water management.
Coordinate rehabilitation with irrigation use or provide necessary
Middle barrell was rehabilitated in previous project.
Notes:
Apply Permanent Seeding in areas of soil disturbance or as directed.
temporary water management.
Coordinate rehabilitation with irrigation use or provide necessary
Prior to rehabilitation, contractor to verify culvert lengths.
Notes:
MP 50.41 & 50.42
Sec. 30, T.01 N., R.43 E., W.M.
MP 50.77
OR82
WB
EB
OR82
WB
EB
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 49'
Type 1 marker
5 50.42 D050508
8 50.77 D041996
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 24" culvert - 82'
Rehabilitate extg. 24" culvert - 82'
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 24" culvert - 58'
Rehabilitate extg. 18" culvert - 49'
Type 1 markerType 1 marker
TEMPORARY WATER MANAGEMENT NOTES
and restore site as per plans and specifications.
Remove all Temporary Water Management features sediment-laden water does not leave the site.
storm events and to insure that sediment and periods, this facility shall be upgraded for unexpected anticipated site conditions. During the construction on this plan is the minimum requirements for
The Temporary Water Management Facility shown is completed and approved.
responsibility of the contractor until all construction replacement and upgrading of this facility is the
Management Plan and the construction, maintenance, The implementation of this Temporary Water
Plastic
Sandbag barrier
SANDBAG BARRIER DETAIL
1 2
6 7
HB03
H_M24104_clpl_01.dgn :: HB03 2/9/2026 2:30:03 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB04 2/9/2026 2:30:04 PM hwye56x
Sec. 32, T.01 N., R.43 E., W.M.
MP 51.04 MP 51.17
CULVERT ID MARKER TABLE
Check where appropriate
4 51.04
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
7 51.17
D042062
D042063
Apply Permanent Seeding in areas of soil disturbance or as directed.
rehabilitation and replace upon completion.
There is a small utility conduit in left barrel. Remove prior to temporary water management.
Coordinate rehabilitation with irrigation use or provide necessary
Prior to rehabilitation, contractor to verify culvert lengths.
Notes:
Apply Permanent Seeding in areas of soil disturbance or as directed.
as directed.
left of the barrels with Class 100 riprap and blend to existing banks
Riprap Inlet Protection - Fill scoured area at culvert inlets and to the temporary water management.
Coordinate rehabilitation with irrigation use or provide necessary
Prior to rehabilitation, contractor to verify culvert lengths.
Notes:
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
(see note below)
Install Class 100 riprap inlet protection - 10 CY
Rehabilitate extg. 36" culvert - 68'
Rehabilitate extg. 24" culvert - 68'
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 58'
Rehabilitate extg. 18" culvert - 58'
OR82
WB
EB
OR82
WB
EBType 1 marker Type 1 marker
TEMPORARY WATER MANAGEMENT NOTES
and restore site as per plans and specifications.
Remove all Temporary Water Management features sediment-laden water does not leave the site.
storm events and to insure that sediment and periods, this facility shall be upgraded for unexpected anticipated site conditions. During the construction on this plan is the minimum requirements for
The Temporary Water Management Facility shown is completed and approved.
responsibility of the contractor until all construction replacement and upgrading of this facility is the
Management Plan and the construction, maintenance, The implementation of this Temporary Water
Plastic
Sandbag barrier
SANDBAG BARRIER DETAIL
1 2
5 6
HB04
H_M24104_clpl_01.dgn :: HB04 2/9/2026 2:30:04 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB05 2/9/2026 2:30:04 PM hwye56x
MP 53.50 MP 55.46
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Notes:
CULVERT ID MARKER TABLE
Check where appropriate
3 53.50
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
5 55.46
D042068
D042087
Type 1 marker
Type 1 marker
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 24" culvert - 54'
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 50'
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
temporary water management.
Coordinate rehabilitation with irrigation use or provide necessary completion.
Remove small utility in pipe prior to work, and replace upon
Middle of culvert is CMP with concrete on both ends.
Notes:
connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Install 24" conc. culv. pipe - 3'
Remove 3' Lt.
24" conc. culvert - 54' (In pl.)
Sec. 4, T.01 S., R.43 E., W.M. Sec. 10, T.01 S., R.43 E., W.M.
OR82 WB
EB
O R82
W B
EB
TEMPORARY WATER MANAGEMENT NOTES
and restore site as per plans and specifications.
Remove all Temporary Water Management features sediment-laden water does not leave the site.
storm events and to insure that sediment and periods, this facility shall be upgraded for unexpected anticipated site conditions. During the construction on this plan is the minimum requirements for
The Temporary Water Management Facility shown is completed and approved.
responsibility of the contractor until all construction replacement and upgrading of this facility is the
Management Plan and the construction, maintenance, The implementation of this Temporary Water
Plastic
Sandbag barrier
SANDBAG BARRIER DETAIL
HB05
H_M24104_clpl_01.dgn :: HB05 2/9/2026 2:30:04 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB06 2/9/2026 2:30:05 PM hwye56x
Sec. 15, T.01 S., R.43 E., W.M.
MP 55.67 MP 57.60
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Middle of culvert is CMP with concrete on inlet end.
Notes:
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Middle of culvert is CMP with concrete on both ends.
Notes:
CULVERT ID MARKER TABLE
Check where appropriate
3 55.67
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
5 57.60
D042080
D042084
Type 1 marker
Type 1 marker
Connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 18" CMP culv. pipe - 3'
Remove 3' Rt.
18" CMP - 60' (In pl.)
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 60'
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 58'
Sec. 24, T.01 S., R.43 E., W.M.
OR82 WB
EB
OR82 WB
EB
HB06
H_M24104_clpl_01.dgn :: HB06 2/9/2026 2:30:05 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB07 2/9/2026 2:30:05 PM hwye56x
Sec. 24, T.01 S., R.43 E., W.M.
MP 58.57 MP 58.65
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
prior to rehabilitation and replaced upon completion.
Inlet of culvert has vertical stand pipe that will need to be removed sections and replace with CMP.
Middle of culvert is CMP with concrete outlet end. Remove concrete
Notes:
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Middle of culvert is CMP with concrete on both ends.
Notes:
CULVERT ID MARKER TABLE
Check where appropriate
3 58.57
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
6 58.65
D042089
D042090 connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 36" conc. culv. pipe - 3'
Remove 3' Lt.
36" conc. culvert - 52' (In pl.)
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 36" culvert - 52'
Type 1 marker Type 1 marker
OR82
WB
EB
OR82
WB
EB
connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 18" CMP culv. pipe - 6'
Remove 6' Lt.
18" conc. culvert - 56' (In pl.)
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 56'
HB07
H_M24104_clpl_01.dgn :: HB07 2/9/2026 2:30:05 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB08 2/9/2026 2:30:06 PM hwye56x
MP 58.95
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Middle of culvert is CMP with concrete on both ends.
Notes:
Type 1 marker
OR82
Connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 18" CMP culv. pipe - 6'
Remove 18" culvert Rt. - 6'
18" conc. culvert - 58' (In pl.)
MP 59.44
OR82
WB
EB
Type 1 marker
Sec. 25, T.01 S., R.43 E., W.M.
EB
WB
Connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 18" CMP culv. pipe - 8 LF
Remove 18" culvert Lt. - 8 LF
18" conc. culvert - 58' (In pl.)
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 58'
Connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 36" CMP culv. pipe - 3'
Remove 36" culvert Lt. - 3'
36" conc. culvert - 48' (In pl.)
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 36" culvert - 48 LF
CULVERT ID MARKER TABLE
Check where appropriate
4 58.95
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
7 59.44
D042091
D042092
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
section at inlet and replace with CMP.
Middle of culvert is CMP with concrete on both ends. Remove concrete
Notes:
HB08
H_M24104_clpl_01.dgn :: HB08 2/9/2026 2:30:06 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB09 2/9/2026 2:30:06 PM hwye56x
MP 61.32
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
temporary water management.
Coordinate rehabilitation with irrigation use or provide necessary
Middle of culvert is CMP with concrete at inlet end.
Notes:
Type 1 marker
OR82
Connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 18" CMP culv. pipe - 3'
18" CMP - 50' (In pl.)
MP 61.42
Type 1 marker
Sec. 29, T.01 S., R.44 E., W.M.
EB
WB
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 53'
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 24" culvert - 60'
CULVERT ID MARKER TABLE
Check where appropriate
4 61.32
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
7 61.42
D042094
D042095
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
temporary water management.
siphon. Coordinate rehabilitation with irrigation use or provide necessary
Culvert has steep inlet and outlet sections and functions as an irrigation
Notes:
sandbag barrier dam
Install Temp. water management -
TEMPORARY WATER MANAGEMENT NOTES
and restore site as per plans and specifications.
Remove all Temporary Water Management features sediment-laden water does not leave the site.
storm events and to insure that sediment and periods, this facility shall be upgraded for unexpected anticipated site conditions. During the construction on this plan is the minimum requirements for
The Temporary Water Management Facility shown is completed and approved.
responsibility of the contractor until all construction replacement and upgrading of this facility is the
Management Plan and the construction, maintenance, The implementation of this Temporary Water
Plastic
Sandbag barrier
SANDBAG BARRIER DETAIL
sandbag barrier dam
Install Temp. water management -
HB09
H_M24104_clpl_01.dgn :: HB09 2/9/2026 2:30:06 PM hwye56x
ST
ERE
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
RENEWS: 6-30-2027
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
WALLOWA COUNTY
WALLOWA LAKE HIGHWAY
CULVERT REPAIR PROJECT
OR82: WALLOWA TO JOSEPH
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
H_M24104_clpl_01.dgn :: HB10 2/9/2026 2:30:07 PM hwye56x
MP 67.23
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Notes:
Type 1 marker
OR82
Connect to extg. pipe
Match extg. grade
Match extg. material
5' depth
Inst. 18" CMP culv. pipe - 6'
Remove 18" culvert Rt. - 6'
18" CMP - 64' (In pl.)
MP 67.87 & 67.91
OR82
WB
EB
Type 1 marker
Sec. 6, T.02 S., R.45 E., W.M.
EB
WB
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 64'
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 50'
CULVERT ID MARKER TABLE
Check where appropriate
3 67.23
MPNote
Culvert Location Type 1 Marker Type 2 Marker
InletInlet OutletOutletNumber
DFI
Number
Structure
5 67.87
D042104
D042105
Apply Permanent Seeding in areas of soil disturbance or as directed.
Prior to rehabilitation, contractor to verify culvert lengths.
Culverts are mostly full of sediment.
Notes:
Sec. 7, T.02 S., R.45 E., W.M.
67.917 D042106
Type 1 marker
Install Type 2 culvert marker - 1 EA
Install Type 1 culvert marker - 1 EA
Rehabilitate extg. 18" culvert - 50'1
HB10
H_M24104_clpl_01.dgn :: HB10 2/9/2026 2:30:07 PM hwye56x
57V-062
CULVERTS MARKER DETAILS
ST
ERE
RENEWS: 6-30-2027
JU
LD
E R
HOLA
W A
19202
D A
Y
Y
YDER
R D
.d g n
J U
L for rivet hole locations
See dwg. no. TM570
ODOT
D panelRoundCorners:0constructPanelMode:0constructPanels:36|24|18levels:GSCOLORFILL|GSBWFILL|GSOUTLINE
TYPE 2 MARKER
TYPE 2 MARKER INSTALLATION
3.5"
1"
.25"
.5"
.75" Non-reflective green tape band
.5"
1", (typ.)
.25" (typ.)
s e e n o te s a n d o r
B ri d g e s tr u c tu re I
D
D ra in a g e f a c il it y
I D
D
F I) black, (typ. all) non-reflectorized
Type C font paddle non-reflective
White
2" m in
Fo g lin e
Ed ge o f p av em en t
Ed ge o f p av em en t
Fo g lin e
In cr ea se m ile p oi nt
Culvert inlet
Culvert inlet
Culvert inlet
Culvert inlet
In cr ea se m ile p oi nt
Barrel B
Barrel A
Edge of pavem ent
Fog Line typ. rivet holes
Paddle with typ. holes
Paddle with
Headwall
Wingwall
ODOT
D
(See Note 8) rivets and washers aluminum blind
(4) 3/16" dia.
steel post with paddle to type 1U
Fasten Type 2 marker
(See Note 8)
MULTIPLE PIPES
SINGLE DRAINAGE FACILITY
SINGLE PIPE
SINGLE DRAINAGE FACILITY
2" m in .4"
6"-12"Varies
(See Note 8)
MULTIPLE DRAINAGE FACILITY
Varies
4"
6"-12"
INSTALLATION
CONCRETE HEADWALL
edge of pavement and letters facing
Type 2 marker, numbers edge of pavement lane, numbers facing post parallel to travel mounted on steel
Type 2 marker paddle pavement lane, numbers facing edge of on steel post parallel to travel
Type 2 marker paddle mounted facing edge of pavement post parallel to travel lane, numbers
Type 2 marker paddle mounted on steel line
Ground slope
Steep concrete anchors with 4 (3/16" X 2") concrete wall
Fasten to with inlet side of first culvert fused thermoplastic tape. Place in line
Type 1 marker, Type B Green preformed
GUARDRAIL INSTALLATION
(See notes 1, 3 and 9) rivets and washers, aluminum blind
(4) 3/16" dia.
steel post with paddle to type 1U
Fasten Type 2 marker
INSTALLATION
CONCRETE BARRIER
Inlet concrete barrier
Precast median
Type 2 marker concrete anchors wall with 2 (3/16" X 2")
Fasten to concrete side of culverts tape. Place in line with inlet preformed fused thermoplastic
Type 1 marker, Type B Green first culvert (see note 10) in line with inlet side of thermoplastic tape. Place
Green preformed fused
Type 1 marker, Type B
.2
NOTES:
10. Install only a Type 1 marker or a Type 2 marker on concrete barrier.
Type 2 marker on slope side of barrier.
9. Steep slopes where guardrail or concrete barrier are present, install
Engineering Technical Services Branch.
Maintenance Hydraulic Engineer in the Hydraulic Unit of the contact the Senior Culvert Hydraulic Engineer or the Senior Culvert
8. For more information on Single and Multiple Drainage Facilities, marker when a culvert has a span equal to or greater than 6 feet.
7. Bridge Structure ID: Place the assigned ID number on the Type 2 marker when the culvert span is less than 6 feet. (Example D10123).
6. Drainage Facility ID: Place the assigned DFI number on the Type 2
5. On divided highways placing markers on the outlet side is optional.
side of highway.
4. On non-divided highways place markers only at the culvert inlet inconspicuous to traffic.
3. Install Type 2 culvert markers parallel to travel lane and with the inlet.
2. Place Type 1 marker on inlet edge of the pavement directly in line details.
1. See Standard Drawing TM571 for 'Type 1U Steel Post Dimensions'
WADE HOLADAY
WADE HOLADAY
CHRIS DIEHL
CHRIS DIEHL
OF TRANSPORTATION
OREGON DEPARTMENT
Checker:Drafter:
Designer:
SHEET NO.
Reviewer:
AVAILABLE UPON REQUEST
FINAL ELECTRONIC DOCUMENT
UNION & WALLOWA COUNTIES
WALLOWA LAKE HIGHWAY
MINAM TO WALLOWA
OR82: CULVERT PROJECT
F O
T N
E
MTRAPED
N
O G
E R
O
N
OI
T
ATROPS
N A
R T
HB11
H_M24104_clpl_01.dgn :: HB12 2/9/2026 2:30:07 PM hwye56x
RD300
INSTALLATIONS
PIPE ZONE AND MULTIPLE
TRENCH BACKFILL, BEDDING,
R D
.d g n
14-JUL-2014N/A
J U
L
C
"A" note 4)
(See general
Tracer wire
MULTIPLE INSTALLATIONS
DIAMETER MIN. SPACE BETWEEN PIPES
(in)
"A"
(in)
"B"
(in)
"C"
(in)
"D"
TABLE A
Finish grade stabilization, as required
Trench foundation see Table A
"C" Pipe bedding, Top of subgrade as directed
Topsoil or existing material
Surfacing-match
Base material m a te r ia l
E x c a v a te d n a ti v e
C la s s A c r u s h e d r o c k
C la s s B o r m a x
1 ( c le a n s a n d
C la s s C
A s d ir e c te d m a te r ia l m a x
C la s s D p it o r b a r r u n
C L
S M
C la s s E
T re n c h b a c k fi ll a re a P ip e z o n eS e e T a b le
A
D
Nom."B" "B"
Pipe diameter
24" min.
m in
D ia
Up to 48"
48" to 72"
24"
) dia. of pipe2
One half (
4. See Std. Dwg. RD336 for tracer wire details (When required).
3. Pipes over 72" diameter are structures, and are not applicable to this drawing.
diameter.
used and the pipe is ≥ 36" diameter, increase dimension "B" to nominal pipe
2. For pipe installation in embankment areas where the trench method will not be
1. Surfacing of paved areas shall comply with street cut Std. Dwg. RD302.
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
see general note 3.
For pipes over 72" diameter, the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2025 - May 31, 2026
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
Standard Drawing, while
The selection and use of this
RD302
STREET CUT
R D
.d g n
20-JUL-2020N/A
J U
L
(Actual)
Trench width whichever is greater. Compact as specified.
4. Place AC mix minimum thkn. of 6" or the thkn. of the removed pavement, details.
3. For joining new concrete to existing concrete, see contract plans for sepecific or to the thickness of removed pavement, whichever is greater.
2. Concrete pavement shall be replaced with concrete to a minimum thickness of 8"
1. All existing AC or PCC pavement shall be sawcut prior to repaving.
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
(AC patch only) with tack material and sand
Seal surface over joint concrete as specified
CLSM or full depth asphalt
Compacted aggregate base, backfill as specified
Compacted trench
(Extg.)
Undisturbed base
Extg. pvmt.
see general notes
Pvmt. replacement, min.
6" min.
6"
Min. width=Roller width plus 2" m in
Tack coat cut edges (AC only) the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2025 - May 31, 2026
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
RD325
CORRUGATED METAL PIPE
COUPLING BANDS FOR
R D
.d g n
REVISED DETAILS AND NOTES01-2023
20-JAN-2023N/A
J A
N
⅝
½
⅜
⅝
⅝
½
Band 7"
W
(In) Pipe Dia.
(In) Pipe Dia.W (In)
Ann.Hel. Bolts "2
# Of W (in)
Ann.Hel.
24-84
18-84
12-15
6-10
2-3
36-120
36-84
Bolts "2
# Of
Dim. A
C o rr u g a ti o n s
60-84
24-54
12-21
84-120
60-84
36-54
Rods # Of
Rods # Of
"x
(in) W
(in) W
"x anchors, when required.
See Std. Dwgs. RD330 and RD332 for pipe slope8.
engineer.
or other insulating material as approved by the a full width neoprene gasket or coated with asphalt connected, the connecting band shall be used with To prevent galvanic action when unlike metals are7.
diameters over 42".
bands of two or more pieces are required for pipe pipe diameters up to and including 42". Coupling One or two piece coupling bands are optional for6.
Standard Specifications.
tested for water tightness in accordance with the Joints for sanitary sewers and siphons are to be5.
".16 3diameter, the gasket thickness may be centering on the joint. For pipes 12" or less in thick of a width equal to the band width and
" 8 3vulcanized) synthetic, closed-cell sponge rubber all coupling bands shall be (butt-cemented or installations when shown on the plans. Gaskets for irrigation pipes, storm sewers, and other Watertight joints with gaskets are required for4.
corrugation and pipe diameter shown may be used.
width coupling band indicated for the band type, used as an acceptable alternate, the minimum Under conditions where concrete pipe may be3.
that used for the pipe.
aluminum pipe shall be of the same thickness as nominal thickness. Coupling bands for corrugated 0.109" nominal thickness nor less than 0.052" than that used for the pipe but not more than pipes may be two numerical thicknesses lighter Coupling bands for corrugated iron and steel2.
shall be galvanized or aluminum coated.
All steel coupling bands and connection hardware1.
TYPE E
TYPE DTYPE BTYPE A
HELICAL COUPLINGANNULAR COUPLING
CONNECTION ANGLE DETAIL
TOP VIEW
END VIEW END VIEW
COUPLING BAND DIMPLE DETAIL
" Corrugations2 1"x3
22 3"x1" Corrugations
(In) Pipe Dia.
(In) Rod Dia.
Narrow Band Wide Band
Req'd. above 42" dia.
to 42" diameter.
Second angle conn. opt.
Band (See general note 4) where required Watertight joint gasket
"16 32"x2"x
" bolts2 and toe of angle of corrugation at heel fillet weld at crest Rivet, spotweld or bolts "2
Band
Pipe Band
Pipe with cut washers " carriage bolts8
32 -
W W joints req'd. for watertight
(Sigma) clips
Band
(See general note 4) where required Watertight joint gasket with cut washers " carriage bolts8
32 -pipe corrugated Helically
Helical pipe
Band
Pipe
(See general note 6) where required Watertight joint gasket
Cast lug
Band
4 - Rods and lugs
Cast lug
Pipe as reqd. to fit the helix angle.
Dimension A: 7" min. between dimples
" bolts2 13 -
Pipe
Band min 12"
"16 32"x2"x to fit the helix angle 8 spaces as reqd.
"2
(For 6"-10" dia. pipes)
(For 12"-30" dia. pipes)
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2025 - May 31, 2026
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
RD326
COUPLING BANDS FOR
R D
.d g n
REVISED DETAILS AND NOTES01-2023
20-JAN-2023N/A
J A
N
"2
TYPE F-2
"2
(See Std. Dwg. RD327) bolt bar
Tension strap and bolt (Typ.)
"x6" carriage2
21"
(12"-42" diameter)
Spot welded 8" band angle end for helical pipe
Reformed pipe bolt (Typ.)
"x6" carriage2
(48"-144" diameter) strap with bolt bar
Spot welded tension
SINGLE BAR & STRAP CONNECTOR
DOUBLE BAR & STRAP CONNECTOR
a a
(Typ.)
See INSERT "A"
"4
3"x1" corrugations width is 14
", with8 corrugations width is 13
"2
"x3
For annular pipe with 2 end helical pipe
Reformed rolled
(See general note 4) where required
Watertight joint gasket
(when required) to annular corrugations
Spiral pipe ends reformed sleeve gasket, when required
" neoprene strip or8
(Typ.)
Alternate O-ring gasket
"3
" or 21"2
"2
"3
2"
JOINT DETAIL (TYPE F1 & F2)
INSERT "B"
TYPE F
JOINT DETAIL (TYPE F)
INSERT "A"
"2
21"
SINGLE 12" BAND ANGLE CONNECTOR
DOUBLE BAND ANGLE CONNECTOR
bolt (Typ.)
"x6" carriage2 connector
12" Band angle for clarity (Typ.)
Band lap not shown
TYPE F-1
bolt (Typ.)
"x6" carriage2 connector
8" Band angle for clarity (Typ.)
Band lap not shown
(Typ.)
See INSERT "B"
(Typ.)
See INSERT "B"
(Typ.)
"x6" bolts2
2 -
"2 with bolt bar tension strap
Spot welded a
(See Detail "A" on Std. Dwg. RD327)
Tension strap and bolt bar
(12"-84" diameter) with bolt bar
Spot welded tension strap
(48"-84" diameter)
Spot welded 12" band angle
(48"-144" diameter)
Spot welded 20" band angle a anchors, when required.See Std. Dwgs. RD330 and RD332 for pipe slope8.
other insulating material as approved by the engineer.
band shall be used with a full width neoprene gasket or coated with asphalt or
To prevent galvanic action when unlike metals are connected, the connecting7.
pipe diameters over 42 inches.
including 42 inches. Coupling bands of two or more pieces are required for diameters up to andOne or two piece coupling bands are optional for pipe6.
accordance with the Standard Specifications.
for water tightness inJoints for sanitary sewers and siphons are to be tested5.
inch.16 pipes 12 inches or less in diameter, gasket thickness may be inch thick of a width equal to the band width and centering on the joint. For8 shall be (butt-cemented or vulcanized) synthetic, closed-cell sponge rubber and other installations when shown on the plans. Gaskets for all coupling bands
Watertight joints with gaskets are required for irrigation pipes, storm sewers,4.
inch bands).8 inch minimum diameter (14-8 inch bands) and 1-8 and 13-inch2 nch minimum diameter (10-i16 between bands. "O" ring gaskets shall be inch band) shall be placed in lap4 inch band) or 9 inch (14-8 band) or 8 inch (13-inch2 inch wide by 5 inch (10-2
1-inch by8
C443 and a mastic sealant strip
Gaskets for the Type F coupling band shall be "O" rings conforming to ASTM3.
to arch pipes of equal peripheral measurement.
Type F coupling bands shown for pipes 15 inch to 72 inch in diameter are typical2.
See Std. Dwg. RD325 for general notes, and details not shown.1.
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
SINGLE 8" BAND ANGLE CONNECTOR
the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2025 - May 31, 2026
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
RD327
COUPLING BANDS FOR
R D
.d g n
REVISED DETAILS AND NOTES01-2023
20-JAN-2023N/A
J A
N are required for pipe diameters over 42 inches.
up to and including 42 inches. Coupling bands of two or more pieces
4. One or two piece coupling bands are optional for pipe diameters
."16 in diameter, the gasket thickness may be the band width and centering on the joint. For pipes 12 inches or less thick of a width equal to"8 synthetic, closed-cell sponge rubber
Gaskets for all coupling bands shall be (butt-cemented or vulcanized) storm sewers, and other installations when shown on the plans.
3. Watertight joints with gaskets are required for irrigation pipes, approved by the engineer.
gasket or coated with asphalt or other insulating material as the connecting band shall be used with a full width neoprene
2. To prevent galvanic action when unlike metals are connected, not shown.
1. See Std. Dwgs. RD325 and RD326 for general notes, and details provide a tensile strength of 7500 lbs are permissible.
Design variations in fasteners (Straps, bars, & welds) which
NOTE:
provide a tensile strength of 7500 lbs are permissible.
Design variations in fasteners (Straps, bars, & welds) which
NOTE:
Coupling band sealant where required
Watertight joint gasket or
Forged steel bar
" dia.8
(Typ.)
" square hole16
(Typ.)
Spot welds Band sheet
"4
"x84
Tension strapBolt bar
(See general note 3)
"4
"8
" 2
BOLT BAR DETAIL
WATERTIGHT JOINT
TENSION STRAP
DETAIL A
TOP
FRONT
FLAT BAND OR DIMPLE BAND
TYPE K
(FOR PIPE EXTENSIONS ONLY)
or helical end with reformed end
New pipe extension with helical end
Extg. pipe
(See table A)
W connector
Band angle connector
Bar & Strap bolt (Typ.)
"x6" carriage2
BAND ANGLE CONNECTOR DETAIL
DOUBLE BAR & STRAP CONNECTOR DETAIL
Band Type
Steel
Aluminum
Corrugations (In)
Pipe Dia.
(In)
Min. W Gasket Type
Sleeve
Sleeve
54-144
54-84
12-48
54-96
54-84
12-48
"2 1"x3
* 3"x1" 5"x1"
"2 1"x3
* 3"x1" 5"x1"
TABLE A
* Arch pipe only
Insulating material connecting band
Standard
(See general note 2)
Type varies with pipe of unlike material
Extending existing pipe culvert
CONNECTION DETAILS
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
bolt (Typ.)
"x6" carriage2 the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2025 - May 31, 2026
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
RD339
CONNECTIONS
PIPE TO STRUCTURE
R D
.d g n
REVISED NOTES07-2021
20-JAN-2023N/A
J A
N
PLAN PLAN
grout
Non-shrink
(See general note 5)
Tracer wire
(See general note 1)
Sump shown
(typ.)
grout
Non-shrink
(See general note 5)
Tracer wire (Typ.)
(See general note 1)
Sump shown
(See general note 5)
Tracer wire (Typ.)
(See general note 7)
Pipe zone (Typ.)
(See general note 7)
Pipe zone (Typ.)
(See general note 6)
Resilient connector
(See general note 5)
Tracer wire
(See general note 1)
Sump shown
(See general note 1)
Sump shown
(See general note 6)
Resilient connector (Typ.)
(See general note 5)
Tracer wire (Typ.)
(See general note 7)
Pipe zone (Typ.)
(See general note 7)
Pipe zone (Typ.)
(See general note 5)
Tracer wire (Typ.)
(See general note 6)
Resilient connector (Typ.)
CONNECTION OF FLEXIBLE PIPE TO STRUCTURECONNECTION OF RIGID PIPE TO STRUCTURE
SECTION C-CSECTION D-DSECTION A-ASECTION B-B
B
B
A A C C
D
D
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
7. Pipe zone varies, see Std. Dwg. RD300.
6. When flexible pipe is used, install resilient connectors conforming to requirements of ASTM C923.
See Std. Dwg. RD336 for tracer wire details.
5. All connecting pipes shall have a tracer wire, or approved alternate.
4. Maximum pipe diameter varies with pipe material.
3. Location, elevation, diameter, slope, and number of pipe(s) varies, see project plans.
2. See appropriate standard drawings or special project details for other similar structures.
1. See Std. Dwgs. RD364, RD365, and RD366 for inlet details not shown.
04-2022 REVISED NOTES
01-2023 REVISED DETAILS AND NOTES
(typ.)
grout
Non-shrink
(typ.)
grout
Non-shrink the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2025 - May 31, 2026
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
RD365
FOR CONCRETE INLETS
FRAMES & GRATES
R D
.d g n
14-JUL-2014N/A
J U
L all bars
Both ends "16
"4
4 corners "4 32'-4 h e x b a r o f e q u iv a le n t a r e a r o u n d r e c t.
o r
C r o s s b a r s h e x b a r o f e q u iv a le n t a r e a r o u n d r e c t.
o r
C r o s s b a r s flat bar each end
"2
"x28
"x2" or8
(Typ.)
" on center8 at 1
" flat bars2
"x28
Bearing bars
T y p ic a l a ll b a rs see general note 3
For cross bars, third inner bar and every outer bars both ends, Typical "16
"2
2" b a r s o n c e n te r s
1'-9"
(Bicycle-safe) edge flat bars
" sq.2
"x22
"8
1'-9
2 each end
"x3" bolt8 angle (Typ.)
"8
"x2
3"x2
"4
1'-10
"4
4 anchors
"4
4 corners
T y p
" (Typ.)2
2 each end
"x3" bolt8 5 "
2 each end
"x3" bolt8
(Typ.)
" on center8 at 1
" flat bars2
"x28
Bearing bars flat bar each end
"2
"x28
"x2" or8 see general note 3
For cross bars, third inner bar and every outer bars both ends, Typical
"2
2T y p ic a l a ll b a rs
3 "16
2'-3"
"2
1'-1 "2
1'-1 b a r s o n c e n te r s
(2 grates required per inlet, as shown)
(Bicycle-safe)
2"
2 each end
"x3" bolt8
"8
2'-3 edge flat bars
" sq.2
"x22 angle (Typ.)
"8
"x2
3"x2
"4
4 anchors
" (Typ.)2
T y p
(Typ.)
sq. edge flat bar
"2
"x28
"2
(Typ.)
sq. edge flat bars
"4
"x2'-62
"x28
Bearing bars
"2
"2
2'-3"
Spacing 3" O.C.
(See general note 2)
5. Cast iron grate and frame are acceptable alternates. See ODOT's QPL.
4. Hot dip galvanize after fabrication.
resistance welded or electroforged to bearing bars.
" cross bars shall be flush with the top of grate surface and may be fillet welded,8
3.
2. Type 1 grate allowed only in locations not subject to bicycle or pedestrian use.
1. For inlet details, see appropriate inlet standard drawing(s).
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
(TYPE 1)
G-2, G-2M, G-2MA, CG-2 GRATE
(TYPE 2)
G-2, G-2M, G-2MA, CG-2 GRATE
(TYPE 2)
G-1, CG-1 GRATE
G-1, CG-1 FRAME G-2, G-2M, G-2MA, CG-2 FRAME
the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2025 - May 31, 2026
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
RD370
TYPE D
DITCH INLET
R D
.d g n
21-JUL-2015N/A
J U
L
Grate
Ditch flow
Frame
See Detail A
Frame
V a r ie s
2'-0"
3'-0"
6" 6"
6" "8
2'-3
"8
3'-3
6"
(See general note 10)
(Typ.)
Pipe connection varies(See general note 6)
Tracer wire
Grate
"4
2'-4
2'-3"
(See general note 2) (See general note 2)
See Detail A
(See general note 6)
Tracer wire
Grate
Frame
Ditch flow
6" 2'-0"
3'-0"
6"
(Anchor bolt modication, see general note 2)
"4
4 anchors
Grate
Frame
2 each end
"x3" bolt (Modified)8
SECTION A - A ELEVATION
PLAN
AA
G-2 FRAME G-2 GRATE (TYPE 1)
DETAIL A
11. Location, elevation, diameter, slope, and number of pipe(s) varies, see project plans.
10. See Std. Dwg. RD339 for pipe to structure connections.
All precast inlets shall conform to requirements of ASTM C913.
"-0 crushed aggregate shall be provided.4 leveling bed of sand or
9. Inlet base may be cast-in-place or precast. Where precast inlet base is used as an alternate, a 4" compacted
8. Do not use in locations where inlet can be struck by an errant vehicle, or provide shielding of inlet.
7. Max. pipe diameter varies with pipe material.
6. See Std. Dwg. RD336 for tracer wire details, or approved alternate.
to bearing bars.
" cross bars shall be flush with the grate surface and may be fillet welded, resistance welded or electroforged8
5.
4. Provide sump only when shown on plans, and allowed by jurisdiction. For sump details, see Std. Dwg. RD364.
3. Catch basin, frame, and grates shall meet H20 loading.
G-2 (Type 2) grates may be used if approved by the engineer.
Modify anchor bolt attachment to frame as shown in Detail A.
2. For frame & grate details not shown, see Std. Dwg. RD365.
1. All concrete shall be commercial grade concrete.
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2025 - May 31, 2026
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
| A - Title & Index |
| A01 |
| H - Hydraulic |
| HB01 |
| HB02 |
| HB03 |
| HB04 |
| HB05 |
| HB06 |
| HB07 |
| HB08 |
| HB09 |
| HB10 |
| HB11 |
| 2026-02-23T11:30:25-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:31:16-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:32:14-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:33:04-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:33:50-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:35:15-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:36:09-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:36:59-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:38:21-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:39:12-0800 | |
| HOLADAY Wade |
| 2026-02-23T11:40:01-0800 | |
| HOLADAY Wade |
File details come from the government source that posted it. Updated .