Image-guided surgical robotic system for femur fracture reduction - 1 long-bone fractures such as those in the femur afflict more than 430,000 americans per year and are 2 rising due to the aging…

Active Project Grant Awarded Last action

Award ID
R01EB036365
Recipient
Awarding agency
Obligated
$2,373,852

Award facts

Completion date 66% complete
Place of performance
Glassboro, NJ 08028, USA

Award details come from USAspending.gov.

Description

Image-guided surgical robotic system for femur fracture reduction - 1 long-bone fractures such as those in the femur afflict more than 430,000 americans per year and are 2 rising due to the aging population. Such fractures are serious injuries that require surgery. Aligning the long bone 3 fragments requires high precision in the presence of a huge traction force and is performed manually by 4 orthopedic surgeons before fixation. Surgeons have limited visual feedback even with repeated X-RAY images, 5 and rotational malalignment of 10° or more after fracture fixation occurs in 28% of patients. Complications include 6 malalignment or nonunion of bone fragments, leg shortening, soft tissue damage, and high exposure to X-RAY 7 radiation. 8 this work proposes a surgical robotic system that facilitates long-bone alignment currently performed 9 manually. The long-term objectives are to build and demonstrate a surgical robot that provides a large workspace 10 for the surgeon, can provide traction forces sufficiently large to align the bone fragments without damaging the 11 bones, and provides sub-millimeter precision for alignment. Patient outcomes will be improved by decreasing 12 procedure times and eliminating complications that require repeated operations, such as leg length 13 discrepancies and abnormal gait. The first specific aim focus is to develop an image-guided navigation system 14 to automatically align based on surgeon selected positioning on 3D model of the bone fragments. The second 15 specific aim focus is to demonstrate use of a force-feedback (HAPTIC) controller for the surgeon to sense the 16 magnitude and direction of the muscle forces and manipulate the robot to align the femur segments. The third 17 specific aim is (I) to develop a clinical-grade robotic system that align bone fragments, eliminate the need for 18 manually applied force during alignment, and provide an open surgical field for the surgeon, (II) to integrate robot 19 with the navigation system and HAPTIC controller, and (III) evaluate its performance via cadaver testing and user 20 feedback. 21 this design-directed translational research will result in a robotic system that transforms surgical 22 practices for femur fractures and reduces complications. The use of the robot is anticipated to improve alignment 23 by 90% compared to unassisted surgery. The research lays the groundwork for future work to automate bone 24 segment alignment with a new innovative image-guided path-planning algorithm.

Transactions

Action Obligated Date
Amendment $443,700
Amendment $48,738
Amendment $438,651
Amendment $438,651
Amendment $502,056
Original award $502,056

Subawards

Subrecipient Amount Awarded
Virtua Health, Inc. Collaboration on the design and development of the robotic system, focusing on the bone-gripping mechanism and surgeon's console. Evaluate methods for attaching… $63,256
The Johns Hopkins University Johns Hopkins University will perform design, development and validation of the new robot and the master console, during the first two years of the grant, and… $88,719

Quick answers

Who received award R01EB036365?

R01EB036365 was awarded to Rowan University by National Institute of Biomedical Imaging and Bioenginering (National Institutes of Health) on May 1, 2024.

How much is award R01EB036365 worth?

$2,373,852 has been obligated on R01EB036365.

On GovTribe

See this award's full record

  • Every transaction and subaward
  • The recipient's other awards and teaming partners
  • Similar grant awards
  • Ask GovTribe AI about this award