Developing a quantitative MRI application to monitor hypoxia during radiation therapy for improved outcomes

Active Grant Awarded

Award ID
R01CA312358
Recipient
Awarding agency
Obligated
$692,609

Award facts

Assistance listing
93.394 Cancer Detection and Diagnosis Research
Completion date 6% complete
Place of performance
Baltimore, MD 21205, USA

Award details come from USAspending.gov.

About this award

The Department of Health and Human Services' National Institutes of Health National Cancer Institute awarded The Johns Hopkins University $692,609 on August 3, 2026, under Grant R01CA312358 in the Cancer Detection and Diagnosis Research program (CFDA 93.394). The grant funds validation of two technologies for monitoring tumor oxygenation in vivo during radiation therapy: OxyTrackIMT, an elastomer/silicone-oil-based molecular sensor for longitudinal oxygen measurement by magnetic resonance imaging, and oxygen-enhanced MRI (OE-MRI). The project uses healthy immunocompetent swine to assess longitudinal OxyTrackIMT performance and immunodeficient swine with inducible sarcomas to evaluate tumor oxygenation and radiation therapy response.

The recipient has sub-awarded work to Childrens Hospital Medical Center under sub-award R01CA312358-2007498006, dated November 11, 2026. The sub-recipient will research the electromagnetic behavior of RF coil designs through electromagnetic simulations, assess how coil design, location, coupling, and added electronic circuitry affect sensitivity profiles, and visualize field patterns to identify a coil design that enables detection of needle orientation and rotation.

The award's period of performance runs from August 3, 2026 to July 31, 2031, with work performed in Baltimore, Maryland 21205. The Cancer Detection and Diagnosis Research program supports screening, early detection, and diagnostic methods, including diagnostic imaging, for predicting the course of cancer and monitoring response to therapy.

Description

Abstract
Radiation therapy (RT) is used in the treatment of over 50% of cancer patients, yet responses vary widely due to tumor biology, location, and genetic factors. A key contributor to this variability is tissue oxygenation (PO2), as hypoxic tumors often require two to three times higher radiation doses for effective treatment. However, traditional methods of measuring PO2 are invasive and can interfere with treatment workflows. To address this challenge, stratagen BIO INC., an MIT spin-off, has developed oxytrackimt, a novel elastomer/silicone-oil-based molecular sensor designed for longitudinal PO2 measurement using magnetic resonance imaging (MRI). This technology was previously tested in small animals and transiently during high dose- rate brachytherapy interventions for cervical cancer, enabling noninvasive oxygen monitoring during RT. Despite this progress, accurately measuring PO2 in vivo remains a major hurdle in oncology. Invasive techniques, such as fiber-optic probes, provide only single-point measures in heterogenous tumor environments and can disrupt therapy, while noninvasive approaches like oxygen-enhanced MRI (OE-MRI) and pet imaging are limited by sensitivity, spatial resolution, or accessibility. The lack of reliable oxygenation data during fractionated RT limits our ability to identify and adapt treatment for hypoxic, radioresistant tumor regions. This project aims to validate two technologies, oxytrackimt and OE-MRI, for monitoring tumor oxygenation in vivo. A large animal model is required to evaluate oxytrackimt under clinically relevant conditions that cannot be modeled in cell culture or validated initially in humans. Healthy immunocompetent swine will be used to assess longitudinal oxytrackimt performance, while immunodeficient swine with inducible sarcomas will be used to evaluate PO2 and RT response. Together, these studies will assess the accuracy and reproducibility of oxytrackimt and OE-MRI for longitudinal PO2 monitoring during RT. A key strength is to relate relative MRI based oxygenation signals to absolute tissue oxygenation measured by implanted oxytrackimt sensors, enabling quantitative PO2 mapping throughout the course of RT. Because the sensors are implanted before RT, they can serve both as an in-situ reference standard for validating imaging-based oxygenation maps and as CT/MRI-visible fiducial markers to support accurate fractionated RT planning. Additionally, ultrashort echo time MRI will be used to map early fibrosis deposition during RT, which our preliminary data suggest may precede the establishment of hypoxic tumor regions, and to correlate these changes with longitudinal oxygenation status. The overarching goal is to establish a robust, clinically translatable approach for noninvasively tracking tumor hypoxia and treatment response, and providing IT on a radiation treatment planning workstation at all stages of therapy. Successful validation will support FDA submission of an investigational device exemption (IDE) for an oxytrackimt based PO2 mapping application, paving the way for first-in-human observational studies.

Subawards

Subrecipient Amount Awarded
Massachusetts Institute Of Technology The MIT work will consist of two parts: 1) oxytrack device fabrication, 2) in vitro testing of silicone formulations. $136,573
Childrens Hospital Medical Center Research the electromagnetic behavior of different RF coil designs with the help of electromagnetic simulations. Research the effect on sensitivity profiles… $39,711

Quick answers

Who received award R01CA312358?

R01CA312358 was awarded to The Johns Hopkins University by National Cancer Institute (National Institutes of Health) on August 3, 2026.

How much is award R01CA312358 worth?

$692,609 has been obligated on R01CA312358.

On GovTribe

See this award's full record

  • Every transaction and subaward
  • The recipient's other awards and teaming partners
  • Similar grant awards
  • Ask GovTribe AI about this award