Ultra-precise surgical navigation with continuous anatomy updates via robotically assisted endoscopic computer vision
Active Cooperative Agreement Awarded
- Award ID
- U01EB037538
- Recipient
-
The Johns Hopkins University UEI FTMTDMBR29C7
- Awarding agency
-
National Institute of Biomedical Imaging and Bioenginering
National Institutes of Health, Department of Health and Human Services
- Obligated
- $730,714
Award facts
- Assistance listing
- 93.286 Discovery and Applied Research for Technological Innovations to Improve Human Health
- Completion date 4% complete
- Place of performance
- Baltimore, MD 21205, USA
Award details come from USAspending.gov.
About this award
The Department of Health and Human Services, National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering awarded Cooperative Agreement U01EB037538 to The Johns Hopkins University on September 9, 2026, with $730,714 obligated, under Assistance Listing 93.286, Discovery and Applied Research for Technological Innovations to Improve Human Health. The recipient will develop a robotic platform for endoscopic image-guided surgery that maintains correspondence between preoperative images and the evolving surgical field. The stated accuracy goal is 0.5 mm. The recipient will demonstrate that the platform is feasible and appropriate for endoscopic nasal surgeries, including endoscopic sinus surgery and endoscopic skull base surgery. Work is performed in Baltimore, Maryland 21205. The ultimate completion date is May 31, 2031. The parent program supports hypothesis-, design-, technology-, or device-driven research on biomedical imaging and bioengineering technologies.
Description
- Abstract
- We aim to revolutionize surgical navigation (SN) by developing a robotic platform for endoscopic image-guided surgery. This platform will address two main limitations of SN: the lack of precise spatial resolution, which hinders surgeons from directly making decisions from SN, and the inability to maintain correspondence between preoperative images and the evolving surgical field, which degrades SN performance as surgeries progress. Addressing these limitations could enhance patient safety, patient outcomes, and surgeon efficiency. We will demonstrate that our platform is feasible and appropriate for commonly performed endoscopic nasal surgeries (ENS), which include endoscopic sinus surgery and endoscopic skull base surgery. These surgeries carry a 1.5 to 11.7% risk of eye injury, brain injury, or massive bleeding and rely on SN to mitigate these risks. The current surgical navigation systems are accurate to 2 MM, which is much larger than the submillimeter-thick bones composing the nose's safety envelope. As a result, surgeons cannot rely solely on the SN system for decision making. They must use their judgment to interpret the imprecise information from the SN and make the right surgical decisions. If they make mistakes, IT could harm the patient. If the SN system were accurate to 0.5 MM, which is the same scale as the preoperative CT scan and the safety envelope, then surgeons could confidently and efficiently rely on the information from the navigation system to direct operations. ENS procedures are inherently destructive, which means that the preoperative images and the surgical field quickly lose alignment once the surgery starts. Intraoperative CT scans are used to address this issue, but they come with the drawbacks of exposing patients to more radiation and disrupting the surgical workflow. In this research, we aim to develop a new approach to SN that will achieve sub-millimeter precision and enable real-time reconstruction of the surgical model without additional intraoperative CT scans. We propose to accomplish this by combining ultra-precise endoscope position and orientation encoding from an FDA-approved surgeon-driven, cooperatively controlled robotic endoscope positioning system with powerful machine vision algorithms. These algorithms will analyze endoscopic video for anatomic reconstruction, registration to preoperative CT, and updating the anatomy model during tissue ablation. We hypothesize that the exceptional precision of the robotic endoscope positioning device will help resolve computer vision uncertainties and lead to dense, high-precision anatomic reconstruction. In aim 1, we will establish the safety and accuracy of the robot for holding the endoscope when the surgeon uses IT to operate. In aim 2, we will develop a machine vision-based system for SN. In aim 3, we will develop machine vision algorithms that allow US to reconstruct anatomy using endoscope video precisely. In aim 4, we will test the precision of our SN system in cadaver specimens and patients within IRB-approved studies.
Quick answers
Who received award U01EB037538?
U01EB037538 was awarded to The Johns Hopkins University by National Institute of Biomedical Imaging and Bioenginering (National Institutes of Health) on September 9, 2026.
How much is award U01EB037538 worth?
$730,714 has been obligated on U01EB037538.
On GovTribe
See this award's full record
- Every transaction and subaward
- The recipient's other awards and teaming partners
- Similar grant awards
- Ask GovTribe AI about this award