Eastside/westside wwtps improvements (pumps and blowers)
Active Definitive Contract Awarded
- Contract number
- 1232SA26C0027
- Awardee
-
Comp Environmental Inc. UEI F5G8WTLEFXT3
- Awarding agency
-
Central Program Planning Coordination and Support
Agricultural Research Service, Department of Agriculture
- Obligated
- $349,070
Award facts
- Opportunity
-
- WWTP Improvements Solicitation · 1232SA26Q1041 · Posted Jul 16, 2026
- Contract value 100% obligated
- $349,070.00 Current and potential, with all options
- Completion date 14% complete
- Current and potential, with all options
- Contracting staff
- Funding agency
- Northeast Area Field Research Implementation and Information Delivery, Department of Agriculture
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Set-aside
- Economically Disadvantaged Woman-Owned Small Business
- Competition
- Competed under SAP · 2 offers Simplified Acquisition
- Pricing
- Firm Fixed Price
- Place of performance
- Calverton, MD 20705, USA
- Legislative mandates
-
- Davis-Bacon Act FAR subpart 22.4
- Service Contract Inventory FAR subpart 4.17
Award details come from SAM.gov/FPDS.
About this award
The Department of Agriculture Agricultural Research Service awarded a $349,070 definitive contract to Comp Environmental Inc. for Eastside/Westside wastewater treatment plant improvements on September 14, 2026, under an Economically Disadvantaged Woman-Owned Small Business set-aside.
Comp Environmental Inc. is an 8(a) certified minority and woman-owned small business. Place of performance is Calverton, MD 20705.
The originating solicitation (RFQ 1232SA26Q1041), posted July 16, 2026, sought furnishing and installation of wastewater pumping and blower equipment at the Beltsville Agricultural Research Center, including two submersible pumps at the Westside WWTP Influent Lift Station (530 gpm and 70 gpm units), new NEMA 12K control panels for both stations, and repair, rebuild, or replacement of four blowers at the Eastside WWTP Sludge Holding Tanks. All submersible pumps required non-clog type with explosion-proof motors rated for Class I Groups C & D hazardous locations, ISO-9001 certification, and manufacturer ten-year industry experience with three Mid-Atlantic references. Project management required minimum seven years' experience in wastewater pumping and construction on at least three similar projects plus one blower project. Control panels required 480-volt, 3-phase, 60 Hz configuration with programmable relay logic and HMI monitoring screens; manufacturer field service engineers were required to conduct one day minimum on-site testing and staff instruction at no cost. Performance period is 270 calendar days from notice to proceed, with ultimate completion by June 30, 2027. Award methodology was Lowest Priced Technically Acceptable. Pricing type is firm fixed price. NAICS code 238220 applies; Davis-Bacon prevailing wage rates were required.
Quick answers
Who was awarded contract 1232SA26C0027?
1232SA26C0027 was awarded to Comp Environmental Inc. by Central Program Planning Coordination and Support (Agricultural Research Service) on September 14, 2026.
How much is contract 1232SA26C0027 worth?
The government has obligated $349,070 on 1232SA26C0027.
Which agency awarded contract 1232SA26C0027?
Central Program Planning Coordination and Support (Agricultural Research Service) awarded 1232SA26C0027, with funding from Northeast Area (Field Research Implementation and Information Delivery).
Was contract 1232SA26C0027 competed?