Roof Replacement at Northern Building #402

Closed State & local contract opportunity Posted

Solicitation number
IFB-27013
State
Maryland
Responses due

Opportunity facts

Jurisdiction
Point of contact

Opportunity details come from constructionbidsource.com. Updated .

About this opportunity

Baltimore City Public Schools is soliciting bids for roof replacement at Northern Building #402, a 219,050 square-foot structure, with proposals due October 8, 2026.

The scope requires complete removal of the existing built-up roof (installed in 1965 and at end of service life) and installation of a new 0.80 TPO membrane with tapered insulation designed to achieve a 1/4" per foot slope and R-30 insulation rating using both flat and tapered boards. The work includes all flashing, metalwork, new roof drains with vandal-proof strainers, coping, gutters, downspouts, and replacement of roof-mounted equipment including gravity vents, electric exhaust fans, roof hatches, and boiler and heater stacks. Curb and flashing coordination is required. The roofing system must carry a minimum 20-year "Total System, No Dollar Limit" warranty covering all components and workmanship.

No set-aside, preference program, estimated contract value, contract term, incumbent contractor, evaluation criteria, pre-bid meeting, site-visit date, or question-submission deadline are specified in the posted materials.

Opportunity text

This project is to replace the 219,050 sf roof for this building. The scope of work will replace the entire built-up roof with a new 0.80 TPO roof, using tapered insulation for proposed 1/4" per foot slope as required. Insulation boards - flat and tapered - will be utilized to attain as much of the R-30 rating as possible. The roof replacement shall include all flashing and accessories, metalwork, new drains, and coping necessary. The roofing system will be covered by a minimum 20 year, "Total System, No Dollar Limit" warranty. Curb and flashing will be coordinated. Roof drains, associated piping, and vandal proof strainers will be replaced. All gutters and downspouts will be replaced. Unless new, equipment on the roof will be replaced, including by not limited to gravity vents, exhaust fans (including electric), roof hatches, boiler and heater stacks. The existing roof was last replaced in 1965, is approximately 60 years old and has achieved its life expectancy.