RFQ Main Switchboard Panel Install
Closed State & local contract opportunity Posted
- Solicitation number
- W912HQ26S0034
- State
- Virginia
- Responses due
Opportunity facts
- Jurisdictions
Opportunity details come from constructionbidsource.com. Updated .
About this opportunity
The U.S. Army Corps of Engineers Headquarters is requesting quotes for installation of one 2000-amp main switchboard in building 2593 at the Humphreys Engineer Center in Alexandria, Virginia, under a Total Small Business Set-Aside (NAICS 238210) with quotes due July 15, 2026.
This is a restricted procurement — only firms meeting the SBA's small-business size standard for Electrical Contractors and Other Wiring Installation Contractors may bid.
The scope encompasses removal of the existing non-compliant switchboard, installation of a new UL-listed switchboard meeting NEC (NFPA 70), NFPA 70E, and UFC 3-501-01 standards, and full commissioning. Deliverables include pre-demolition site assessment and load analysis, phased cutover planning to maintain building operations, temporary power provisions, rigging and equipment delivery, insulation resistance testing and functional commissioning per NETA ATS Standards, and restoration of affected areas. All work must be performed by licensed electricians. The contractor must provide all labor, tools, equipment, materials, supervision, and quality control planning. A minimum one-year warranty on equipment and installation, with manufacturer warranty documentation, is required. On-site training for facility personnel upon project completion is mandatory.
The performance period is 180 days from the Notice to Proceed, with operations Monday through Friday, 6:00 AM to 5:00 PM, excluding federal holidays. Place of performance is building 2593, Humphreys Engineer Center, Alexandria, Virginia.
Security and compliance requirements include E-Verify screening, background investigations, NCIC-III and Terrorist Screening Database checks, Level I OPSEC and AT awareness training within 30 calendar days of work start, and an accident prevention plan within 10 working days of award. The contractor must comply with USACE Safety and Health Requirements Manual EM 385-1-1.
No contract value, incumbent information, or formal evaluation criteria are specified in the source materials.
Opportunity text
Total Small Business Set-Aside, 238210 - Electrical Contractors and Other Wiring Installation Contractors. The U.S. Army Corps of Engineers Headquarters has a requirement for the installation of one (1) 2000 Amp main switchboard in building 2593, ground level FACP room.