Radon Detectors for New York State Residents

Open State & local contract opportunity Posted

Solicitation number
2140608
State
New York
Responses due

Opportunity facts

Jurisdiction
Point of contact

Updated .

About this opportunity

New York State Department of Health is soliciting proposals under RFP C044006 for radon detector distribution and laboratory analysis, with written questions due November 24, 2026 and proposals due January 5, 2027. Bidders must be certified by the Department's Environmental Laboratory Approval Program (ELAP) for activated charcoal detector evaluation. The Department has established a 30% Minority and Women-Owned Business Enterprise (M/WBE) participation goal.

The scope covers approximately 6,000 short-term (48-hour to 7-day) activated charcoal adsorption radon detectors annually, analyzed by laboratory gamma scintillation counting. Half ship in bulk to non-profit entities, county health departments, and the Department, and half ship by mail to individual New York State residents. Shipment quantities are tiered at 2-5, 6-49, 50-200, and 201+ units. Bidders may not subcontract laboratory analysis, the actual testing work. Subcontracting is permitted only for ancillary or administrative services, such as sample transport, results shipping, or reporting, and the bidder remains fully responsible for all work. Required submissions include detector hardware samples with bilingual English/Spanish instructions, sample analysis reports, staffing qualifications, and quality assurance documentation. Pricing must be all-inclusive, covering hardware, individual and bulk shipping, return postage, analysis, and reporting.

Proposals will be evaluated on a Best Value basis, with technical qualifications weighted at 70% and cost at 30%. The RFP is funded through the U.S. Environmental Protection Agency's State Indoor Radon Grant, whose terms require low-cost distribution of detectors to the public. The Department anticipates one award with a five-year term starting October 1, 2027, subject to funding availability, successful performance, and approvals from the New York State Attorney General and Office of the State Comptroller. The incumbent contractor is Radon Testing Corporation of America.

Opportunity text

The Department receives the State Indoor Radon Grant from the U.S. Environmental Protection Agency, the terms of which require that radon detectors be distributed to the general public at low cost. The contract resulting from this RFP will provide for the distribution of these devices directly to individuals within New York State and bulk shipments to various non-profit entities, the Department and/or county health departments, as specified by the Department. It is the intent of the Department to obtain accurate and economical short-term (48 hour to 7 day) radon testing kits and laboratory analysis for New York State residents. The method for such measurements will be Activated Charcoal Adsorption Devices (AC) in conjunction with laboratory gamma scintillation counting. The Department has chosen this method based on a combination of cost efficiency and validation experience. Bidders may not propose the use of a subcontractor for the performance of laboratory analysis (i.e., the actual testing/analytical work). Subcontracting is permitted for ancillary or administrative services only (for example, sample transport, shipping of results, or reporting), provided the Bidder remains fully responsible for all work performed under the Contract. Business enterprises awarded an identical or substantially similar procurement contract within the past five years: Radon Testing Corporation of America Minority / Women Business Enterprise contracting goals (MWBE) Total MWBE Goals: 30.00%

Files

File Type Posted
rfp.pdf PDF

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for State & Local Contractors