About this opportunity

Tarrant County, Texas is requesting bids on water and sanitary sewer replacement improvements under CPN 103498, with proposals due August 13, 2026. This is a public works project split into two units with extensive PVC pipe installation and pavement repair work.

Unit 1 encompasses water infrastructure improvements totaling approximately 48,736 linear feet of PVC water pipe in diameters ranging from 6 inches to 16 inches, including 1,288 linear feet of restrained-joint pipe and 277 linear feet of 36-inch casing installation. The unit also includes 2 connections to existing 16-inch water mains and 23 connections to existing 4- to 12-inch water mains. Pavement work comprises 60 linear feet of 4-foot-wide asphalt paving repair (residential), 1,321 linear feet of 4-foot-wide composite pavement repair (arterial/industrial), 3,100 linear feet of 5-foot-wide composite pavement repair (arterial/industrial), 41,079 square yards of 3-inch surface milling, and 41,079 square yards of 3-inch asphalt pavement placement (Type D).

Unit 2 addresses sanitary sewer improvements consisting of 87 linear feet of 8-inch PVC sewer pipe, 1,497 linear feet of 12-inch PVC sewer pipe, 19 sewer service connections with two-way cleanouts, 9 four-inch manholes, and 730 linear feet of 4-foot-wide composite pavement repair (arterial/industrial).

The project manual (100-page PDF, 22 MB) establishes detailed construction standards, material requirements, and workmanship specifications governing contractor performance and proposal preparation. No estimated contract value, set-asides, preferences, or evaluation criteria are identified in the source materials.

Opportunity text

Project Description: Unit 1: Water Improvements 67 LF 6 PVC Water Pipe 1248 LF 8 PVC Water Pipe 117 LF 12 PVC Water Pipe 3727 LF 16 PVC Water Pipe. 1288 LF - 16 PVC Water Pipe (Restrained Joints) 277 LF - 36" Casing By Other Than Open Cut. 2 EA Connection to Existing 16 Water Main. 23 EA Connection to Existing 4-12 Water Main. 60 LF 4 Wide Asphalt Paving Repair, Residential. 1321 LF 4 Wide Composite Pvmt Repair, Arterial/Industrial 3100 LF 5 Wide Composite Pvmt Repair, Arterial/Industrial 41079 SY - 3 Surface Milling. 41079 SY - 3 Asphalt Pvmt Type D. Unit 2: Sanitary Sewer Improvements: 87 LF 8" Sewer Pipe (PVC) 1497 LF 12" Sewer Pipe (PVC). 19 EA 4" Sewer Service w/2-way cleanout 9 EA 4 Manhole. 730 LF 4 Wide Composite Pvmt Repair, Arterial/Industrial.