Moody Water Storage Tank Rehab
Closed State & local contract opportunity Posted
- Solicitation number
- PE-69200-NONST-2025-000000034
- State
- Georgia
- Responses due
Opportunity facts
- Jurisdiction
- NIGP codes
- 06592 Water Tank Bodies
- 21075 Septic Tanks, Grease Traps, And Water Troughs
- 83058 Steel Tanks, Portable Type (For Diesel Fuel, Gasoline, Kerosene, Liquid Fertilizers, Water, Etc.)
- 83061 Steel Tanks, Pressure Type (For Air, Gas, Water, Etc.)
- 83064 Steel Tanks, Surface Storage Type (For Asphalt, Emulsions, Road Oil, Water, Etc.)
- 83067 Steel Tanks, Transport Truck Type (For Asphalt, Gasoline, Oil, Water, Etc.)
- 83073 Steel Tanks, Water Works Type, Elevated And Tower
- UNSPSC codes
- Point of contact
-
- Amy Woods amy.woods@lowndescounty.com (229) 671-2527
Opportunity details come from ssl.doas.state.ga.us. Updated .
About this opportunity
The state and local contract opportunity is a bid for the Moody Water Storage Tank Rehabilitation project located in Liberty County, Georgia. The procurement involves surface preparation and coating of an 84' diameter, 12' deep concrete water storage tank that is partially buried. Key project objectives include comprehensive interior and exterior surface restoration, with a total contract duration set for 90 calendar days. A mandatory pre-bid meeting is scheduled for July 14th, 2025 at 11:00 a.m. in the Lowndes County Administration Building, and sealed proposals will be accepted until July 24th, 2025 at 11:00 a.m. at the same location. Bidders are required to submit a 5% bid bond with their proposal, and bid documents can be viewed at the Lowndes County Utilities office located at 327 N. Ashley Street in Valdosta, Georgia. The project advertisement will be published in the Valdosta Daily Times on June 26th and July 10th, providing potential contractors ample time to review specifications and prepare submissions.
While specific set-aside designations are not explicitly detailed in the provided documentation, potential bidders should be prepared to demonstrate technical capability and financial stability for water infrastructure rehabilitation projects. The bid does not specify incumbent vendors or current contractors, nor does it outline precise budget ranges. Interested contractors will need to review the complete bid documents to understand full qualification requirements, potential integration needs, and specific technical specifications for the water storage tank rehabilitation. The project appears to be open to qualified water infrastructure and rehabilitation contractors who can meet the technical and performance requirements outlined in the full bid documentation. Contractors should carefully review all specifications, prepare comprehensive proposals, and ensure compliance with the 5% bid bond requirement and submission guidelines.
Opportunity text
Invitation to bid is attached
Files
| File | Type | Posted |
|---|---|---|
| Moody Water Storage Tank Rehab Advertisement.docx | DOCX document |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Similar opportunities
- Ask GovTribe AI about this opportunity