HPLC System
Awarded State & local contract opportunity Posted
- Solicitation number
- 55300-eRFQ-000000275-2022
- State
- Georgia
- Responses due
Opportunity facts
- Jurisdiction
- NIGP codes
- UNSPSC codes
- 41105106 Chromatography pumps
- 41115701 Chromatographic detectors
- 41115712 Solid phase extraction SPE columns
- 41115731 QuEChERS Dispersive SPE
- 41115700 Chromatographic measuring instruments and accessories
- 41115711 Liquid chromatography LC columns
- 41115715 Injectors
- 41115716 Liquid chromatography fittings
- 41115722 Fast protein liquid chromatography FPLC column
- 41115725 Thin layer chromatography plate
Show all 38
- 41115728 Ion chromatography IC column
- 41115729 Ion chromatography IC guard column
- 41122203 Metal crucibles
- 41113037 Microplate readers
- 41115709 High pressure liquid chromatography HPLC columns
- 41115719 Gas chromatography liners
- 41115720 Chromatography tubing
- 41115721 Fast protein liquid chromatography FPLC system
- 41115723 Supercritical fluid chromatograph
- 41115726 Thin layer chromatography fitting
- 41115727 Chromatography blotting paper
- 41115730 High pressure liquid chromatography HPLC guard column
- 41115733 Ion chromatography IC eluent generator
- 41122201 Glass crucibles
- 23151816 Chromatography columns
- 23151817 Chromatography media
- 41113036 Microplates
- 41113038 Alcoholometer
- 41115702 Chromatographic scanners
- 41115708 High pressure thin layer chromatograph TLC
- 41115710 Gas chromatography GC columns
- 41115713 Thin layer chromatography tanks
- 41115717 Gas chromatography fittings
- 41115718 Injector septa
- 41115724 Chromatography vial or insert or cap
- 41115732 Liquid chromatograph LC fraction collector
- 41122202 Ceramic crucibles
- 41121822 Laboratory consumables and chemicals
- Point of contact
-
- Alisha Matthews alisha.matthews@ung.edu (706) 864-1942
Opportunity details come from ssl.doas.state.ga.us. Updated .
About this opportunity
The University of North Georgia is requesting quotes for a High-Performance Liquid Chromatography (HPLC) system via eRFQ under the Georgia State Purchasing Act, with quotes due May 11, 2022. The procurement will establish a contract with one or more qualified suppliers.
The system must include a built-in autosampler and a pump capable of flow rates from 0.001 ml/minute to 5 ml/minute with 0.1% flow accuracy at the lowest rate. The pump must accommodate both traditional HPLC and UPLC applications, handle up to four solvents with on-the-fly mixing at ±0.5% accuracy for the lowest flow rate, and include two separate fluid flow paths plus a waste path. A column heater/cooler system is required to maintain consistent conditions and minimize run-to-run variation. The system must integrate a Photodiode Array UV-vis detector capable of monitoring multiple wavelengths simultaneously and recording the full UV-vis spectrum during chromatographic runs. A nitrogen generator is also required for ultra-pure nitrogen supply to support MS systems and other downstream instruments.
The procurement supports semi-preparative work and high-resolution, low sample consumption methods. No estimated contract value, contract term, incumbent vendor, evaluation criteria, or question deadline is stated in the source material.
Opportunity text
Purpose of Procurement Pursuant to the State Purchasing Act (Official Code of Georgia Annotated 50-5-50 et seq.), this electronic Request for Quotes (eRFQ) is being issued to establish a contract with one or more qualified suppliers who will provide HPLC System quotes to the University of North Georgia (hereinafter, the State Entity) as further described in this eRFQ. The HPLC instrument will need to have a built in autosampler system. This pump system is flow rate agile and can accommodate flow rates and pressures typically used in traditional HPLC application while being able to accommodate the lower flow rates and higher pressure needed for UPLC applications. The pump will handle flow rates from 0.001 ml/minute up to 5 ml/minute. At 0.001 ml/minute (1ul/minute) the flow accuracy for this pump is 0.1%. This pump system will allow the University to do both semi-preparative work and high resolution, low sample consumption methods. The pump can use and mix on the fly up to four different solvents and includes two separate fluid flow paths plus a waste path. The mixing accuracy for the lowest flow rate is a mere +/- 0.5%. The pump system must also include a column heater/cooler system. This will create consistent conditions for each method and minimizes run-to-run errors based on ambient conditions. Second, we are looking for the system to include a Photodiode Array UV-vis detector. The PDA not only allows the user to monitor multiple wavelengths at once but also records the entire UV-vis spectrum during the course of the chromatographic run. Additionally we wish all suppliers to include a nitrogen generator. Typically, MS systems require ultra-pure nitrogen to function. The nitrogen generator can also be used to supply gas to other instruments as needed. Overview of the eRFQ ProcessThe objective of the eRFQ is to select one or more qualified suppliers to provide the goods and/or services outlined in this eRFQ to the State Entity. This eRFQ process will be conducted to gather and evaluate responses from supplier for potential award. All quali