About this opportunity
Miami-Dade County Fire Rescue is requesting sealed bids for Fire Station 53 repairs and renovations, including storefront windows, doors, garage doors, and comprehensive building improvements, with bids due August 27, 2026. All new storefront windows, doors, and garage doors in the Apparatus Bay must be Miami-Dade County-approved impact resistant with current Notices of Acceptance (NOAs) — a mandatory specification that filters vendor capability.
The scope spans two phased mobilizations (Exterior and Interior) and includes demolition, storefront and window installation, door and garage door replacement, concrete work, framing and drywall, masonry, stucco application, aluminum insulated panels with screen enclosure, kitchen cabinets and equipment, bunker gear equipment provision, tree removal, epoxy terrazzo flooring, apparatus bay flooring, fencing, and mechanical, electrical, plumbing, and gas systems. Contractors must remove and replace existing windows, doors, overhead garage doors, and ancillary accessories including security card access control systems, door sensors, electric door strikes, hardware, and lock systems. All associated repairs — drywall patching, stucco work, painting, caulking, and wall patching to match existing conditions — are included in the bid price. Roll-up doors must comply with Florida Building Code (FBC) standards and wind load calculations, with motorized lift, new photo eye sensors, and exhaust system contacts. Structural plans are by Ingelmo Associates PA, dated March 12, 2025.
Contractors must bid separate mobilization periods and costs for both phases. Bid prices shall remain firm for 90 days from opening. The detailed RPQ document (miami-dade RPQ_No_MDFRD-901-53-GC.pdf, 136 KB) is attached and governs specific technical requirements, door schedules, and compliance standards.
Opportunity text
Bidding Contractors are to provide sealed bids for all labor, material, transportation, equipment and perform all operations for the following project description to achieve the completion of the project requirements in accordance with the RPQ, Miami-Dade Fire Rescue requirements, and Structural plans by Ingelmo Associates PA, dated 3/12/2025. FIRE STATION REPAIRS AND RENOVATIONS The work in general consists of plans related to Fire Station and Kitchen Restoration to include, Demolition; Storefront; Windows; Doors; Garage Doors; Concrete; Framing & Drywall; Masonry; Stucco; Aluminum Insulated Panel with Screen Enclosure; Kitchen Cabinets & Equipment; Bunker Gear Equipment; Tree Removal; Epoxy Terrazzo Flooring; Apparatus Bay Flooring; Fencing; Mechanical; Electrical; Plumbing & Gas; and adjacent general restoration to the walls, floors, and ceilings that are impacted by the restoration. The project will be phased into two sections: Exterior and Interior. The contractor shall bid for two mobilizations periods and costs. Refer to information noted in PH.1 & PH.2. The new storefront, windows, doors and garage doors in the Apparatus Bay are to be MiamiDade County approved Impact Resistant with current NOAs. The scope is inclusive of removing the existing windows, doors, garage overhead doors with all the ancillary accessories, i.e., security card access control systems, door sensors, electric door strikes, door hardware & lock systems to be replaced with new (refer to plans and specs for details in the door schedule). All repairs such as drywall, stucco, painting, caulking, shutter removal, window shades removal and reinstallation associated with new windows and doors replacement are to be included in the bid price. Existing exterior roll-up doors are also to be removed and replaced with County approved FBC system and meeting the wind load calculations, to include motorized lift, new photo eye sensors, exhaust system contacts, wall patching and painting to match existing. New exterior swing doors are to be primed and painted with direct to metal (DTM) Sherwin Williams paint provided and applied by the contractor. After window replacement and hurricane shutter removal, the contractor shall patch, seal, and paint all walls to match existing. The impacted interior finishes listed on the plans, and mentioned above, shall be continuous throughout the restored areas and finished as new or to match existing surroundings and adjacent conditions. The existing mechanical duct work shall remain, except as noted on the Mechanical Drawings. (Note: There will be modifications to the supply & return duct, Mechanical Room, Bunker Gear Room, and Proposed Dining Room, as well as installation of electrical and plumbing & gas). Contractor to be familiar FFEs, and Dedicated Allowance for this project. The Apparatus Bay resinous flooring on existing concrete flooring and resurfacing noted on the plans & specification 09 67 00, approximately 2000 square feet. STOREFRONT, WINDOWS & DOORS REPLACEMENT PH. 1 Contractor responsible for field verifying all dimensions. The scope is inclusive of removing the existing storefront, windows & doors with sealants and all the ancillary accessories accompanies, i.e., security card access reader systems, existing hurricane shutters, door sensors, electric door strikes, existing door hardware & lock systems to be replaced with new (refer to plans and specs for details on door schedule remarks), window shades, stucco patching, caulking, painting, etc. The proposed new storefront, windows & doors are to be Miami-Dade County approved Impact Resistant with current NOAs, per the bid set drawings by Ingelmo Associates PA. Apply E-level windows and storefront door manufacturers as noted on the plans. The Storefront shall be 3-point locking mechanism with concealed vertical rods and must be connect to the security card access system. Approved Alternate Product: Contractor proposed alternate for Storefront, and Windows must be E-Level product and an authorized manufacturer accepted by Miami-Dade Fire Rescue (MDFR) and the Engineer of Record. The Contractor shall submit a Request for Information (RFI) during the bid process for an approved equal alternate to be accepted by MDFR and the Engineer of Record. The Contractor will be responsible for payment to the A/E related to revision of plans and calculations due to the alternate product change.