Fann Home - Replace G Wing Mixing Valve, D Wing Water Lines

Closed State & local contract opportunity Posted

Solicitation number
SRC0000022471
State
Alabama
Responses due

Opportunity facts

Jurisdictions
NIGP code
UNSPSC codes

Opportunity details come from alabamabuys.gov. Updated .

About this opportunity

The state of Alabama, through the Floyd E. Tut Fann State Veterans Home in Huntsville, is seeking contractors to replace a Symmons mixing valve and install new water lines in the G Wing, as well as repair a damaged 2.5-inch domestic hot water line and a leaking copper tee above a bathroom in the D Wing. The scope of work includes providing labor and materials to disable utilities, isolate and shut off domestic hot and cold-water valves, drain the system, remove and replace components, and restore the domestic hot and cold-water system. A mandatory site visit is scheduled for June 14th, 2024, and proposals are due by June 17th, 2024.

The contract is open to all qualified contractors, with no specific set-aside designations or restrictions on the types of organizations that can respond. The contractor must have the necessary skills and experience to perform the required repairs and replacements, including scheduling work during non-business hours and coordinating with on-site maintenance staff. The contract value is not specified, but the project involves the replacement of various plumbing components and the repair of leaks in the domestic hot water system.

Opportunity text

**Mandatory Site Visit** Friday, June 14th 11:00 AM Location:

Floyd E. Tut Fann State Veterans Home 2701 Meridan Street Huntsville, AL 35811 Contact: Charlotte Robinson 256-851-2807 Scope of Work: Replace Symmons Mising Valve with New Leonard Mixing Valve G Wing and Install New Isolation Valves - Provide Labor and Materials to schedule repairs with management during After Normal business hours. - Provide Labor and Materials to disable the utilities to the domestic boilers, isolate/shutoff the domestic hot & cold-water valves (to the entire building) and drain the system. * Domestic Water to the building will be off for several hours to make proper repairs. - Provide Labor and Materials to remove (1) Symmons Mixing Valve, (2) 1 ½" gate-valves, (1) 2" gate-valve, (3) check valves (one has active leak), (1) 1" Taco recirculating pump, (1) damaged/leaking section of 2" copper pipe (tempered water), and (2) damaged/leaking supply stops for Symmons Mixing Valve. - Provide Labor and Materials to install (1) New Leonard Mixing Valve, reinstall (1) existing 1" Taco recirculating pump with new 1" pro-press isolation valves and spring check valve, Install (2) new 1 ½" pro-press ball-valves (incoming domestic hot & cold) with new spring check valves (one check valve was actively leaking), (1) 2" pro-press ball-valve on outgoing tempered waterline with new spring check valve, Repair leak on 2" tempered water line with new temperature gauge, and reconnect½" hot water line with new isolation valve and spring check valve. - Provide Labor and Materials to restore the utilities to the domestic boilers, turn on the domestic hot & cold-water valves, repressurize the domestic hot & cold-water system, test function, and check for leaks. *On-site maintenance support staff needed to restore the domestic hot & cold-water system and clear air from the system. Repair 2.5" Domestic Hot-Water Line and Domestic Hot-Water Line above D135 Bathroom • Provide Labor and Materials to schedule repairs with management AFTER normal business hours. • Provide Labor and Materials to isolate/shutoff the domestic hot water to the building and drain the system. • Provide Labor and Materials to remove (1) damaged and leaking 2.5" threaded ball-valve, located in the hallway corridor of C Wing. • Provide Labor and Materials to install (1) new 2.5" pro-press ball-valve, with 2.5" type L copper pipe, and 2.5" copper pro-press fittings. • Provide Labor and Materials to remove a damaged and leaking ¾"x ¾" x ½" copper tee, located above the drop ceiling and leading to the hot side of the vanity in Room D135 bathroom. • Provide Labor and Materials to install a new copper pro-press tee, with¾" & ½" type L copper pipe, and additional copper pro-press fittings, needed for a proper repair. • Provide Labor and Materials to restore the hot water to the building, test function, and check for leaks. *On-site support staff needed for restoring the domestic hot water and bleeding the air from the waterlines.