Conservation/Parks/Gulf-FY27 Annual-Fuel Storage Tank Inspections
Closed State & local contract opportunity Posted
- Solicitation number
- SRC0000036688
- State
- Alabama
- Responses due
Opportunity facts
- Jurisdiction
Opportunity details come from alabamabuys.gov. Updated .
About this opportunity
The Alabama Department of Conservation and Natural Resources is soliciting bids for annual fuel storage tank inspections and repairs at its Gulf Shores facility, with proposals due September 30, 2026 and contract performance running October 1, 2026 through September 30, 2027. This is an all-or-none procurement — vendors must demonstrate full capability to perform all required inspections and repairs. Vendors must hold current ADEM (Alabama Department of Environmental Management) and APAC (Alabama Petroleum Association of Contractors) certifications as a mandatory eligibility requirement.
The scope covers testing, inspection, and repair services for two underground petroleum storage tanks — a 3,000-gallon midgrade fuel tank and a 1,000-gallon diesel tank — located at 3180 Maintenance Drive, Gulf Shores, Alabama (Facility ID 11433-003-002038). Required services include annual administrative fees for regulatory reporting and ADEM compliance logging, annual underground storage tank inspections, monthly walkthrough inspections, annual automatic tank gauge testing, annual combo line tightness and leak detector testing, annual liquid sensor testing, triennial overfill testing, and triennial spill bucket testing. Equipment is Wayne and OPW FMS petroleum pump equipment. The vendor must possess certification and capability to complete all necessary repairs on fuel tanks if required. All current tests and inspections are up to date.
Contract documents including detailed specifications are attached. Specific contract value, evaluation criteria, and site-visit or pre-bid meeting dates are not identified in the posted materials.
Opportunity text
All or None ** testing, inspection, and repairs of Wayne and OPW FMS petroleum pump equipment** Vendor must be ADEM and APAC certified to complete the inspections and to do any repairs necessary. Vendor must have the capability to do all repairs on the fuel tanks if needed. (2) Tanks Located at 3180 Maintenance Dr. Gulf Shores, AL 36542 Valid Period: 10/1/2026 -9/30/2027 **See attached specs** These are the only inspections and tests needed, all tests and inspections are current** Facility ID 11433-003-002038
Files
| File | Type | Posted |
|---|---|---|
| DOPQQBPV4.08.26.pdf | ||
| SRC36688. GSP fuel tank inspections.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Similar opportunities