Building 10 Fire Alarm Upgrade - Dept. of Veterans Affairs

Closed State & local contract opportunity Posted

Solicitation number
2026-177 G (1-1)
State
Washington
Responses due

Opportunity facts

Jurisdiction
Points of contact

Opportunity details come from constructionbidsource.com. Updated .

About this opportunity

The Washington State Department of Veterans Affairs is requesting proposals for a Building 10 Fire Alarm Upgrade project in Kitsap County, with proposals due August 25, 2026.

The scope spans multiple building divisions: replacement of interior and exterior doors (Division 8); removal and installation of signage (Division 10); installation of additional fire sprinkler heads for exterior areas (Division 21); installation of new egress lighting (Division 26); installation of fiber optic cabling between Building 10 and Building K fire alarm panels (Division 27); and a complete fire alarm system upgrade (Division 28). The fire alarm system must be a new, fully operational, intelligent analog and addressable digital, low-voltage 24-volt DC microprocessor-based system capable of transmitting signals to a monitoring entity. The system shall include a Fire Alarm System Control Panel, Remote Annunciators, Power Supplies, Graphic Maps, Initiation Devices (smoke detectors, heat detectors, duct detectors, and manual pull stations at all exits), and Notification Appliances (strobes, speakers, and combination speaker/strobes throughout common public areas). The system must interface with smoke and fire/smoke dampers, HVAC systems, magnetic door holders and releases, fire-rated coiling doors and shutters, and fire protection sprinkler systems. All Initiation circuits shall be Class A; all Notification Circuits shall be Class A or Class B. All Signaling Line Circuits must comply with applicable fire alarm standards. Detailed specifications are available in the attached 2026177GSpecs-Final.pdf document posted July 28, 2026.

Opportunity text

In general, the scope includes: Division 8: Openings. a. Replacement of existing interior doors and exterior doors. Refer to drawings for additional information. Division 10: Signage. a. Removal and installation of signage throughout facility. Refer to drawings for additional information. Division 21: Fire Suppression. a. Installation of additional fire sprinkler head for exterior area. Refer to drawings and specifications for additional information. Division 26: Electrical. a. Installation of new egress lighting in building. Refer to drawings and specifications for additional information. Division 27: Communications. a. Install new fiber optic cabling between Building 10 and Building K Fire Alarm panels. Division 28: Fire Alarm/Emergency Communications. a. SUMMARY 2 of 3 The Fire Alarm System shall be a new complete, fully operational, intelligent (analog) and addressable (digital), low voltage 24 Volts D.C. microprocessor-based Fire Alarm System that will transmit a signal to the monitoring entity. b. c. d. e. f. g. h. i. j. k. l. The Fire Alarm System shall consist of the Fire Alarm System Control Panel, Remote Annunciators, Power Supplies, Graphic Maps, Initiation Devices, and Notification Appliances. Initiation Devices shall consist of Smoke Detectors, Heat Detectors, Duct Detectors, Manual Pull Stations at all exits, Monitor Modules, Relay Modules, Control Modules, etc. Smoke & Heat detection for the protection of equipment and openings. Notification appliances shall consist of Strobes, Speakers, Combination Speaker/Strobes throughout common public areas. The Fire Alarm System shall also interface with other systems such as Smoke and Fire/Smoke Dampers, Duct Smoke Detectors, H.V.A.C. Systems, Magnetic Door Holders, Magnetic Door Releases, Fire Rated Coiling Doors, Fire Rated Shutters, Fire Protection Sprinkler Systems, etc. All Initiation circuits shall be "Class A". All Notification Circuits shall be Class A or Class B. All Signaling Line Circuits (SLC), Initiation Circuits, and Notification Circuits, shall be provided with 25 percent spare capacity. All conduits shall be filled to a maximum fill capacity of 40 percent. All cabling is to be plenum rated and installed in conduit when installed in concealed spaces. Open conductors are acceptable in accessible spaces for fire alarm cabling. The Fire Alarm System shall be provided with back-up batteries to power the entire Fire Alarm System for a minimum of 24 hours of standby operation immediately followed by 5 minutes of alarm operation. "Shop Drawing" submittals shall also include equipment submittals, back-up battery calculations and voltage drop calculations. The Fire Alarm System Contractor shall be currently listed and approved by UL for "Proprietary Protective Signal System Listing Program" with a UUJS certificate of compliance and be a NICET certified Level III technician. The Fire Alarm System Contractor shall be capable of designing, installing, and testing a Fire Alarm System in accordance with the latest edition of N.F.P.A. #72. Voluntary numerical Diverse Business goals of 10% MBE, 6% WBE, 5% SBE or PWSBE, and 5% Veterans have been established for this project. Achievement of the goals is encouraged.

Files

File Type Posted
2026177GSpecs-Final.pdf PDF

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for State & Local Contractors