USCGC ALEX HALEY Switchboard Replacement
Forecast New Requirement Updated
- Agency
-
Coast Guard
Department of Homeland Security
- Solicitation expected
- Estimated value
- $2,000,000 to $5,000,000
- Set-aside
- No set-aside
Forecast facts
- Anticipated award
- Through
- NAICS code
- 335313 Switchgear and Switchboard Apparatus Manufacturing
- Place of performance
- Kodiak, AK
- Forecast number
- F2026075455
Forecast details come from DHS's Acquisition Planning Forecast System. Agencies' dates and values are estimates.
About this forecast
The Department of Homeland Security US Coast Guard is procuring replacement 450 VAC, three-phase ship service switchboards for the 282-foot USCGC ALEX HALEY (WMEC-39) through a three-phase effort covering design, fabrication, and installation support. The new switchboard must comply with UL 891 and IEEE 45 standards, measure no more than 192 inches length by 25.25 inches depth by 81 inches height, consist of four separable sections for rigging and installation, and withstand marine environmental stresses of up to 45 rolls and 10 pitch. The solicitation is estimated for release May 20, 2027, with award anticipated December 6, 2027.
The estimated award value ranges from $2 million to $5 million under a Firm Fixed Price purchase order contract awarded through FAR Subpart 13.5, with performance running from December 6, 2027 through December 5, 2028. The vendor must perform critical electrical system analyses including fault current studies, protective device coordination, arc flash assessment, and failure mode analysis. Work is performed at Kodiak, Alaska. Benjamin Clark (benjamin.e.clark@uscg.mil, 571-614-2865) is the contracting point of contact, and Corry Thomas, Chief Warrant Officer 2 (corry.d.thomas@uscg.mil, 206-815-2046), is the requirements contact.
Forecast text
The 282-FT USCGC ALEX HALEY (WMEC-39) Ship Service Switchboards are no longer supportable and require replacement. This project entails the replacement of the ship's service switchboards through a comprehensive three-phase process covering design, fabrication, and installation support. The new 450 VAC, three-phase switchboard must adhere to strict dimensional constraints, with a maximum size of 192 inches in length, 25.25 inches in depth, and 81 inches in height, and must be built to UL 891 and IEEE 45 standards. Designed for a marine environment, it will consist of four separable sections to facilitate rigging and installation and must withstand up to 45° rolls and 10° pitch. Additionally, the vendor will be required to perform critical electrical system analyses, including studies on fault currents, protective device coordination, arc flash, and failure modes.