For supplies and related services for Cryo-EM (Kachar, 26-001128)

Past New Requirement Updated

Agency
Solicitation expected
Estimated value
$25,000 to $250,000
Set-aside
No set-aside

Forecast facts

Anticipated award
NAICS code
541380 Testing Laboratories and Services
Points of contact

Forecast details come from HHS's procurement forecast. Agencies' dates and values are estimates.

About this forecast

The National Institutes of Health forecasts a new requirement for supplies and related services supporting cryo-electron microscopy, with solicitation release and award both estimated for June 1, 2026. The work investigates model cell structures at UVA through in situ cryo-electron tomography using Correlative Light and Electron Microscopy, with cryogenic lamella preparation on the Molecular Electron Microscopy Core's Aquilos 2+ cryo-FIB-SEM and integrated fluorescence microscope, followed by high-throughput data collection on Glacios and Krios systems. Data collection uses ThermoFisher Scientific Tomography 5 software and SerialEM/SPACETomo, while AreTomo3 running on a dedicated 4-GPU workstation generates preprocessing and tomographic reconstructions on the fly.

The estimated award value range is $25,000 to $250,000 under NAICS 541380, Testing Laboratories and Services, and no set-aside is used. Work is described as performed at UVA. Points of contact are Brian Lind, Supervisory Program Specialist in NIH Legal-Contracts (brian.lind@nih.gov, +13015948939), and Shiqiong Hu (shiqiong.hu@nih.gov).

Forecast text

To investigate the model cell structures using cryo-electron microscopy at UVA. In situ cryo-ET using Correlative Light and Electron Microscopy (CLEM). The Molecular Electron Microscopy Core's Aquilos 2+ cryo-FIB-SEM, featuring an integrated fluorescence microscope (iFLM), will be utilized to prepare thin cryogenic sections (lamellae) of cellular samples for in situ cryo-ET. Regions of interest (ROIs) will be identified using the iFLM; lamellae will then be prepared at these sites, with post-milling fluorescence imaging used to target specific loci for data acquisition. High-throughput cryo-ET data collection will be performed on a Glacios (equipped with a Falcon 4

detector) and a Krios (equipped with a K3 detector and BioQuantum energy filter) using the latest ThermoFisher Scientific Tomography 5 software and SerialEM/SPACETomo. Initial preprocessing and tomographic reconstructions will be generated on-the-fly using AreTomo3 software running on a dedicated 4-GPU workstation.

On GovTribe

Work this forecast

  • Track it in your pipeline
  • Find teaming partners
  • Similar forecasts
  • Ask GovTribe AI about this forecast